SU(1,1) Interferometry
   HOME

TheInfoList



OR:

SU(1,1) interferometry is a technique that uses parametric amplification for splitting and mixing of electromagnetic waves for precise estimation of phase change and achieves the
Heisenberg limit The uncertainty principle, also known as Heisenberg's indeterminacy principle, is a fundamental concept in quantum mechanics. It states that there is a limit to the precision with which certain pairs of physical properties, such as position a ...
of sensitivity with fewer optical elements than conventional interferometric techniques.


Introduction

Interferometry Interferometry is a technique which uses the ''interference (wave propagation), interference'' of Superposition principle, superimposed waves to extract information. Interferometry typically uses electromagnetic waves and is an important inves ...
is an important technique in the field of optics that have been utilised for fundamental proof of principles experiments and in the development of new technologies. This technique, primarily based on the interference of
electromagnetic waves In physics, electromagnetic radiation (EMR) is a self-propagating wave of the electromagnetic field that carries momentum and radiant energy through space. It encompasses a broad spectrum, classified by frequency or its inverse, wavelength, ran ...
, has been widely explored in the field of
quantum metrology Quantum metrology is the study of making high-resolution and highly sensitive measurements of physical parameters using quantum theory to describe the physical systems, particularly exploiting quantum entanglement and quantum Squeezed coherent s ...
and precision measurements for achieving sensitivity in measurements beyond what is possible with classical methods and resources. Interferometry is a desired platform for precise estimation of physical quantities because of its ability to sense small phase changes. One of the most prominent examples of the application of this property is the detection of gravitational waves (
LIGO The Laser Interferometer Gravitational-Wave Observatory (LIGO) is a large-scale physics experiment and observatory designed to detect cosmic gravitational waves and to develop gravitational-wave observations as an astronomical tool. Prior to LIG ...
). Conventional interferometers are based on the wave nature of the light and hence the classical interference of electromagnetic waves. Although the design and layout for these types of interferometers can vary depending upon the type of application and corresponding suitable scheme, they all can be mapped to an arrangement similar to that of a Mach-Zehnder interferometer. In this type of interferometry, the input field is split into two by a beam splitter which then propagates along different paths and acquires a relative phase difference (corresponding to a path length difference). Considering one of the beams undergoing a phase change as the ''probe'' and the other beam as the '' reference'', the relative phase is estimated after the two beams interfere at another beam splitter. The estimation of the phase difference is done through the detection of the intensity change at the output after the interference at the second beam splitter. These standard interferometric techniques, based on beam-splitters for the splitting of the beams and linear optical transformations, can be classified as SU(2) interferometers as these interferometric techniques can be naturally characterized by
SU(2) In mathematics, the special unitary group of degree , denoted , is the Lie group of unitary matrices with determinant 1. The matrices of the more general unitary group may have complex determinants with absolute value 1, rather than real 1 ...
(Special Unitary(2)) group. Theoretically, the sensitivity of conventional SU(2) interferometric schemes are limited by the vacuum fluctuation noise, also called the shot-noise limit which scales as 1/\sqrt N, where N is the mean number of particles (photons for electromagnetic waves) entering the input port of the interferometer. The shot noise limit can be overcome by using light that utilizes quantum properties such as
quantum entanglement Quantum entanglement is the phenomenon where the quantum state of each Subatomic particle, particle in a group cannot be described independently of the state of the others, even when the particles are separated by a large distance. The topic o ...
(e.g. squeezed states, NOON states), at the unused input port. In principle, this can achieve the
Heisenberg limit The uncertainty principle, also known as Heisenberg's indeterminacy principle, is a fundamental concept in quantum mechanics. It states that there is a limit to the precision with which certain pairs of physical properties, such as position a ...
of sensitivity which scales as 1/N with the change in the mean number of photons entering the input port.
SU(1,1) In mathematics, the special unitary group of degree , denoted , is the Lie group of unitary matrices with determinant 1. The matrices of the more general unitary group may have complex determinants with absolute value 1, rather than real 1 i ...
interferometers were first proposed by Yurke ''et al.'' in which the beam splitters in conventional interferometers were replaced by optical parametric amplifiers. The advantage that comes with the parametric amplifiers is that the input fields can be coherently split and interfere that would be fundamentally quantum in nature. This is attributed to the
nonlinear In mathematics and science, a nonlinear system (or a non-linear system) is a system in which the change of the output is not proportional to the change of the input. Nonlinear problems are of interest to engineers, biologists, physicists, mathe ...
processes in parametric amplifiers such as
four-wave mixing Four-wave mixing (FWM) is an intermodulation phenomenon in nonlinear optics, whereby interactions between two or three wavelengths produce two or one new wavelengths. It is similar to the third-order intercept point in electrical systems. Four-wave ...
. Theoretically, SU(1,1) interferometers can achieve the Heisenberg limit of sensitivity with fewer optical elements than conventional interferometers.


Theory

To briefly understand the benefit of using a parametric amplifier, a balanced SU(1,1) interferometer can be considered. Treating the input fields as
quantum fields In theoretical physics, quantum field theory (QFT) is a theoretical framework that combines field theory and the principle of relativity with ideas behind quantum mechanics. QFT is used in particle physics to construct physical models of subatom ...
described by
operators Operator may refer to: Mathematics * A symbol indicating a mathematical operation * Logical operator or logical connective in mathematical logic * Operator (mathematics), mapping that acts on elements of a space to produce elements of another ...
a_1 ^ , a_2 ^, the output quantum fields from a parametric amplifier can be written as: a_1 ^ = G a_1 ^ + g a_2 ^ a_2 ^ = g a_1 ^ + G a_2 ^ where G is the amplitude gain and \left\vert G \right\vert^2 - \left\vert g \right\vert^2 = 1. For a
coherent state In physics, specifically in quantum mechanics, a coherent state is the specific quantum state of the quantum harmonic oscillator, often described as a state that has dynamics most closely resembling the oscillatory behavior of a classical harmo ...
input , \alpha\rangle at the first parametric amplifier with initial input intensity I_0 = \left\vert \alpha \right\vert^2, the output intensities will be: I_1 ^o = 2G^2 g^2 I_0 (1+\cos\phi) (for \left\vert \alpha \right\vert^2 >>1) I_2 ^o = (2G^2 g^2 + 1)(\left\vert \alpha \right\vert^2)(1+\nu\cos\phi) (for \left\vert \alpha \right\vert^2 >>1) where \nu = \frac is the
visibility In meteorology, visibility is the measure of the distance at which an object or light can be clearly discerned. It depends on the Transparency and translucency, transparency of the surrounding air and as such, it is unchanging no matter the amb ...
. This shows two main distinguishing features of an SU(1,1) interferometer from SU(2) interferometers: 1. The two output intensities of an SU(1,1) interferometer are in phase whereas in a SU(2) interferometer the two outputs are out of phase. 2. The outputs are amplified as compared to that of a SU(2) interferometer when the gain G is large. The first feature indicates a high correlation of the output photon numbers (intensities) and the second feature shows that there is an enhancement of the signal strength for a small phase change as compared to SU(2) interferometers. From these properties, the signal to noise ratio R_ for an SU(1,1) interferometer compared to the signal to noise ratio R_ of a SU(2) interferometer is calculated to be (see Ref. for detailed calculation): R_/R_ \approx 2G^2 (for \left\vert \alpha \right\vert^2 >>1) This means that the sensitivity in phase measurements is improved by a factor of 2G^2 in an SU(1,1) interferometer and hence can achieve the ''sub-shot noise limit'' of sensitivity in conditions where a SU(2) interferometer approaches the shot-noise limit. It is also shown in Ref. that with no coherent state injection, the SU(1,1) interferometer approaches the Heisenberg limit of sensitivity.


Noise performance

The improvement of phase measurement sensitivity in an SU(1,1) interferometer is not by a 2G^2 amplification at the second parametric amplifier. Similar amplification could also be implemented in a SU(2) interferometer where both the signal and the noise (vacuum quantum fluctuations) gets amplified. However, the difference comes in the noise performance of an SU(1,1) interferometer. A quantum amplifier (in this case a parametric amplifier) can utilize
quantum entanglement Quantum entanglement is the phenomenon where the quantum state of each Subatomic particle, particle in a group cannot be described independently of the state of the others, even when the particles are separated by a large distance. The topic o ...
for effective noise cancellation. For an input state with a strong correlation with the internal modes of an amplifier, the quantum noise can be cancelled at the output through destructive
quantum interference In physics, interference is a phenomenon in which two coherent waves are combined by adding their intensities or displacements with due consideration for their phase difference. The resultant wave may have greater amplitude (constructive int ...
. This is the principle behind noise reduction in an SU(1,1) interferometer. The first parametric amplifier produces two quantum entangled fields that are used for phase sensing and are the input to the second parametric amplifier where the amplification takes place. In a scenario of no internal losses inside the interferometer, the output noise for a destructive quantum interference is still similar to the case of a SU(2) interferometer. Overall, there is an amplification in the signal with no change in the noise (as compared to SU(2) interferometer). This leads to the improvement in phase sensitivity over SU(2) interferometry.


Effect of losses

The reduced sensitivity of an interferometer can be mainly due to two types of losses. One of the sources of losses is the inefficient detection protocol. Another type of loss affecting the sensitivity is the internal loss of an interferometer. Theoretical studies by Marino ''et al.'' inferred that an SU(1,1) interferometer is robust against losses due to inefficient detectors because of the disentanglement of states at the second parametric amplifier before the measurements. However, the internal losses in an SU(1,1) interferometer limit its sensitivity below the Heisenberg limit during its physical implementation. The original scheme for an SU(1,1) interferometer proposed by Yurke ''et al.'' did not take into account the internal losses and for a moderate gain of the parametric amplifier produced a low number of photons which made it difficult for its experimental realization. Marino ''et al.'' showed that in the presence of any internal losses, an SU(1,1) interferometer could not achieve the Heisenberg limit for configurations with no input fields at both the ports or a coherent state input in one of the ports (this configuration was considered for the Theory section above). For a case with coherent state input at both the input ports, it was shown that the interferometer is robust against internal losses and is one of the ideal schemes for achieving the Heisenberg limit.


Experiments

The originally proposed configuration of an SU(1,1) interferometer by Yurke ''et al.'' was challenging to realize experimentally due to very low photon numbers expected at the output (for ideal sensitivity) and also the theory did not take into account the internal losses that could affect the phase change sensitivity of the interferometer. Subsequently, modifications to the scheme were studied taking into account the losses and other experimental imperfections. Some of the initial experiments proving the predicted scaling of the SU(1,1) interferometer and other experiments modifying the scheme are discussed below.


Coherent state boosted SU(1,1) interferometer

The boost in the photon numbers from a coherent state injection was proposed and studied by Plick ''et al.''. Such a scheme was experimentally implemented by Jing ''et al.'' with Rb-85 vapor cells for parametric amplification. The experiment verified the increase in the fringe size due to the amplification of the signal. Later, experiments performed by Hudelist ''et al.'' showed that there is an enhancement in the signal by a factor of 2G^2 with SU(1,1) interferometry over the conventional SU(2) interferometry.


Modified SU(1,1) interferometers

Modifications to SU(1,1) interferometers have been proposed and studied with the goal of finding an experimentally ideal scheme with the desired characteristics of SU(1,1) interferometry. Some of the schemes explored include: 1. SU(1,1) interferometry with one parametric amplifier and a beam splitter replacing the second amplifier: The signal to noise ratio improvement in this configuration was found to be essentially the same as that of the original SU(1,1) interferometry sensitivity improvement over conventional interferometers. This study showed that the improvement is mainly due to the entangled fields generated at the first parametric amplifier. 2. “Truncated” SU(1,1) interferometer with no second parametric amplifier and rather using a photocurrent mixer to realize the superposition of the fields. Such a configuration opens the possibility to implement SU(1,1) interferometry in experiments where fewer optical elements help minimize the error due to experimental imperfections.


References

{{Reflist Interferometry