image:Contact angle.svg, 400px, Fig 1: An illustration of the sessile drop technique with a liquid droplet partially wetting a solid substrate. is the contact angle, and represent the solid–gas, gas–liquid, and liquid–solid interfaces, respectively. In materials science, the sessile drop technique is a method used for the characterization of solid surface energy, surface energies, and in some cases, aspects of liquid surface energies. The main premise of the method is that by placing a
droplet A drop or droplet is a small column of liquid, bounded completely or almost completely by free surfaces. A drop may form when liquid accumulates at the lower end of a tube or other surface boundary, producing a hanging drop called a pendant ...
of liquid with a known surface energy and
contact angle The contact angle is the angle, conventionally measured through the liquid, where a liquid–vapor interface meets a solid surface. It quantifies the wettability of a solid surface by a liquid via the Young equation. A given system of solid, liq ...
, the surface energy of the solid substrate can be calculated. The liquid used for such experiments is referred to as the probe liquid, and the use of several different probe liquids is required.


Probe liquid

The surface energy is measured in units of
Joules The joule ( , ; symbol: J) is the unit of energy in the International System of Units (SI). It is equal to the amount of work done when a force of 1 newton displaces a mass through a distance of 1 metre in the direction of the force applied. ...
per area, which is equivalent in the case of liquids to surface tension, measured in Newtons per
meter The metre (British spelling) or meter (American spelling; see spelling differences) (from the French unit , from the Greek noun , "measure"), symbol m, is the primary unit of length in the International System of Units (SI), though its pref ...
. The overall surface tension/energy of a liquid can be acquired through various methods using a
tensiometer Tensiometer may refer to one of a number of devices. The two most common are: * Tensiometer (surface tension) an instrument used to measure the surface tension of liquids *Tensiometer (soil science) A tensiometer in soil science is a measur ...
or using the pendant drop method and
maximum bubble pressure method In physics, the maximum bubble pressure method, or in short bubble pressure method, is a technique to measure the surface tension of a liquid, with surfactants. __TOC__ Background When the liquid forms an interface with a gas phase, a molec ...
. The interface tension at the interface of the probe liquid and the solid surface can additionally be viewed as being the result of different types of
intermolecular forces An intermolecular force (IMF) (or secondary force) is the force that mediates interaction between molecules, including the electromagnetic forces of attraction or repulsion which act between atoms and other types of neighbouring particles, e.g. a ...
. As such, surface energies can be subdivided according to the various interactions that cause them, such as the surface energy due to dispersive (e.g. van der Waals forces) and other interactions (e.g.
hydrogen bonding In chemistry, a hydrogen bond (or H-bond) is a primarily electrostatic force of attraction between a hydrogen (H) atom which is covalently bound to a more electronegative "donor" atom or group (Dn), and another electronegative atom bearing a l ...
, polar interactions, acid/base interactions, etc.). It is often useful for the sessile drop technique to use liquids that are known to be incapable of some of those interactions (see
table 1 Table may refer to: * Table (furniture), a piece of furniture with a flat surface and one or more legs * Table (landform), a flat area of land * Table (information), a data arrangement with rows and columns * Table (database), how the table data ...
). For example, the surface tension of all straight alkanes is said to be entirely dispersive, and all of the other components are zero. This is algebraically useful, as it eliminates a variable in certain cases, and makes these liquids essential testing materials. The overall surface energy, both for a solid and a liquid, is assumed traditionally to simply be the sum of the components considered. For example, the equation describing the subdivision of surface energy into the contributions of dispersive interactions and polar interactions would be: :\sigma_=\sigma_^+\sigma_^ :\sigma_=\sigma_^+\sigma_^ Where σS is the total surface energy of the solid, σSD and σSP are respectively the dispersive and polar components of the solid surface energy, σL is the total surface tension/surface energy of the liquid, and σLD and σLP are respectively the dispersive and polar components of the surface tension. In addition to the tensiometer and pendant drop techniques, the sessile drop technique can be used in some cases to separate the known total surface energy of a liquid into its components. This is done by reversing the above idea with the introduction of a reference solid surface that is assumed to be incapable of polar interactions, such as polytetrafluoroethylene (PTFE).


Contact angle

The contact angle is defined as the angle made by the intersection of the liquid/solid interface and the liquid/air interface. It can be alternately described as the angle between solid sample's surface and the tangent of the droplet's ovate shape at the edge of the droplet. A high contact angle indicates a low solid surface energy or chemical affinity. This is also referred to as a low degree of wetting. A low contact angle indicates a high solid surface energy or chemical affinity, and a high or sometimes complete degree of wetting. For example, a contact angle of zero degrees will occur when the droplet has turned into a flat puddle; this is called complete
wetting Wetting is the ability of a liquid to maintain contact with a solid surface, resulting from intermolecular interactions when the two are brought together. This happens in presence of a gaseous phase or another liquid phase not miscible with ...
.


Measuring contact angle


Goniometer method

The simplest way of measuring the contact angle of a sessile drop is with a contact angle goniometer, which allows the user to measure the contact angle visually. A droplet is deposited by a syringe which is positioned above the sample surface, and a high resolution camera captures the image from the profile or side view. The image can then be analyzed either by eye (with a protractor) or more often is measured using image analysis software. This type of measurement is referred to as a static contact angle measurement. The contact angle is affected not only by the surface chemistry but also by the surface roughness. The Young equation, which is the basis for the contact angle, assumes a homogeneous surface with no surface roughness. In case surface roughness is present, the droplet can be in Wenzel state (homogeneous wetting), Cassie-Baxter state (heterogeneous wetting) or in an intermediary state. The surface roughness amplifies the wetting behavior caused by the surface chemistry. In order to measure the contact angle hysteresis, the sessile droplet can be increased gradually in volume. The maximum possible contact angle is referred to as the advancing contact angle. The receding contact angle can be measured by removing volume from the drop until dewetting occurs. The minimum possible contact angle is referred to as the receding contact angle. The contact angle hysteresis is the difference between the advancing and receding contact angle.


=Advantages and disadvantages

= The advantage of this method, aside from its relatively straightforward nature, is the fact that with a large enough solid surface, multiple droplets can be deposited in various locations on the sample to determine heterogeneity. The reproducibility of particular values of the contact angle will reflect the heterogeneity of the surface's energy properties. Conversely, the disadvantage is that if the sample is only large enough for one droplet, then it will be difficult to determine heterogeneity, or consequently to assume homogeneity. This is particularly true because conventional, commercially available goniometers do not swivel the camera/backlight set up relative to the stage, and thus can only show the contact angle at two points: the right and the left edge of the droplet. In addition to this, this measurement is hampered by its inherent subjectivity, as the placement of the lines is determined either by the user looking at the pictures or by the image analysis software's definition of the lines.


Wilhelmy method

An alternative method for measuring the contact angle is the Wilhelmy method, which employs a sensitive force meter of some sort to measure a force that can be translated into a value of the contact angle. In this method, a small plate-shaped sample of the solid in question, attached to the arm of a force meter, is vertically dipped into a pool of the probe liquid (in actuality, the design of a stationary force meter would have the liquid being brought up, rather than the sample being brought down), and the force exerted on the sample by the liquid is measured by the force meter. This force is related to the contact angle by the following equation: :\cos\theta = \frac Where ''F'' is the total force measured by the force meter, ''F''b is the force of buoyancy due to the solid sample displacing the liquid, ''I'' is the wetted length, and σ is the known surface tension of the liquid.


=Advantages and disadvantages

= The advantage of this method is that it is fairly objective and the measurement yields data which is inherently averaged over the wetted length. Although this does not help determine heterogeneity, it does automatically give a more accurate average value. Its disadvantages, aside from being more complicated than the goniometer method, include the fact that sample of an appropriate size must be produced with a uniform cross section in the submersion direction, and the wetted length must be measured with some precision. In addition, this method is only appropriate if both sides of the sample are identical, otherwise the measured data will be a result of two completely different interactions. Strictly speaking, this is not a sessile drop technique, as we are using a small submerging pool, rather than a droplet. However, the calculations described in the following sections, which were derived for the relation of the sessile drop contact angle to the surface energy, apply just as well.


Determining surface energy

While surface energy is conventionally defined as the work required to build a unit of area of a given surface, when it comes to its measurement by the sessile drop technique, the surface energy is not quite as well defined. The values obtained through the sessile drop technique depend not only on the solid sample in question, but equally on the properties of the probe liquid being used, as well as the particular theory relating the parameters mathematically to one another. There are numerous such theories developed by various researchers. These methods differ in several regards, such as derivation and convention, but most importantly they differ in the number of components or parameters which they are equipped to analyze. The simpler methods containing fewer components simplify the system by lumping surface energy into one number, while more rigorous methods with more components are derived to distinguish between various components of the surface energy. Again, the total surface energy of solids and liquids depends on different types of molecular interactions, such as dispersive (van der Waals), polar, and acid/base interactions, and is considered to be the sum of these independent components. Some theories account for more of these phenomena than do other theories. These distinctions are to be considered when deciding which method is appropriate for the experiment at hand. The following are a few commonly used such theories.


One component theories


The Zisman Theory

The Zisman theory is the simplest commonly used theory, as it is a one component theory, and is best used for non-polar surfaces. This means that polymer surfaces that have been subjected to
heat treatment Heat treating (or heat treatment) is a group of industrial process, industrial, thermal and metalworking, metalworking processes used to alter the physical property, physical, and sometimes chemical property, chemical, properties of a material. ...
,
corona treatment Corona treatment (sometimes referred to as air plasma) is a surface modification technique that uses a low temperature corona discharge plasma to impart changes in the properties of a surface. The corona plasma is generated by the application of ...
,
plasma cleaning Plasma cleaning is the removal of impurities and contaminants from surfaces through the use of an energetic plasma or dielectric barrier discharge (DBD) plasma created from gaseous species. Gases such as argon and oxygen, as well as mixtures such ...
, or
polymers A polymer (; Greek '' poly-'', "many" + ''-mer'', "part") is a substance or material consisting of very large molecules called macromolecules, composed of many repeating subunits. Due to their broad spectrum of properties, both synthetic an ...
that contain heteroatoms do not lend themselves to this particular theory, as they tend to be at least somewhat polar. The Zisman theory also tends to be more useful in practice for surfaces with lower energies. The Zisman theory simply defines the surface energy as being equal to the surface energy of the highest surface energy liquid that wets the solid completely. That is to say, the droplet will disperse as much as possible, i.e. completely wetting the surface, for this liquid and any liquids with lower surface energies, but not for liquids with higher surface energies. Since this probe liquid could hypothetically be any liquid, including an imaginary liquid, the best way to determine the surface energy by the Zisman method is to acquire data points of contact angles for several probe liquids on the solid surface in question, and then plot the cosine of that angle against the known surface energy of the probe liquid. By constructing the Zisman plot, one can extrapolate the highest liquid surface energy, real or hypothetical, that would result in complete wetting of the sample with a contact angle of zero degrees.


=Accuracy/precision

= The line coefficient (Fig 5) suggests that this is a fairly accurate result, however this is only the case for the pairing of that particular solid with those particular liquids. In other cases, the fit may not be so great (such is the case if we replace polyethylene with poly(methyl methacrylate), wherein the line coefficient of the plot results using the same list of liquids would be significantly lower). This shortcoming is a result of the fact that the Zisman theory treats the surface energy as one single parameter, rather than accounting for the fact that, for example, polar interactions are much stronger than dispersive ones, and thus the degree to which one is happening versus the other greatly affects the necessary calculations. As such, it is a simple but not particularly robust theory. Since the premise of this procedure is to determine the hypothetical properties of a liquid, the precision of the result depends on the precision to which the surface energy values of the probe liquids are known.


Two component theories


The Owens/Wendt theory

The Owens/Wendt theory (after D. K. Owens and R. C. Wendt) divides the surface energy into two components: surface energy due to dispersive interactions and surface energy due to polar interactions. This theory is derived from the combination of Young's relation, which relates the contact angle to the surface energies of the solid and liquid and to the interface tension, and Good's equation (after R. J. Good), which relates the interface tension to the polar and dispersive components of the surface energy. The resulting principle equation is: :\frac=\frac+\sqrt Note that this equation has the form of ''y'' = ''mx'' + ''b'', with: :\begin y &= \frac \\ pt m &= \sqrt \\ pt x &= \frac \\ pt b &= \sqrt \end As such, the polar and dispersive components of the solid's surface energy are determined by the slope and intercept of the resulting graph. Of course, the problem at this point is that in order to make that graph, knowing the surface energy of the probe liquid is not enough, as it is necessary to know specifically how it breaks down into its polar and dispersive components as well. To do this, one can simply reverse the procedure by testing the probe liquid against a standard reference solid that is not capable of polar interactions, such as PTFE. If the contact angle of a sessile drop of the probe liquid is measured on a PTFE surface with: :\begin \sigma_^ &= 0 \\ \sigma_^ &= 18.0~\mathrm \end the principle equation reduces to: :\sigma_^ = \frac Since the total surface tension of the liquid is already known, this equation determines the dispersive component, and the difference between the total and dispersive components gives the polar component.


=Accuracy/precision

= The accuracy and precision of this method is supported largely by the confidence level of the results for appropriate liquid/solid combinations (as seen, for example, in fig 6). The Owens/Wendt theory is typically applicable to surfaces with low charge and moderate polarity. Some good examples are polymers that contain heteroatoms, such as PVC,
polyurethanes Polyurethane (; often abbreviated PUR and PU) refers to a class of polymers composed of organic units joined by carbamate (urethane) links. In contrast to other common polymers such as polyethylene and polystyrene, polyurethane is produced from ...
,
polyamides A polyamide is a polymer with repeating units linked by amide bonds. Polyamides occur both naturally and artificially. Examples of naturally occurring polyamides are proteins, such as wool and silk. Artificially made polyamides can be made throug ...
,
polyesters Polyester is a category of polymers that contain the ester functional group in every repeat unit of their main chain. As a specific material, it most commonly refers to a type called polyethylene terephthalate (PET). Polyesters include natural ...
,
polyacrylate An acrylate polymer (also known as acrylic or polyacrylate) is any of a group of polymers prepared from acrylate monomers. These plastics are noted for their transparency, resistance to breakage, and elasticity. Acrylate polymer is commonly used ...
s, and
polycarbonates Polycarbonates (PC) are a group of thermoplastic polymers containing carbonate groups in their chemical structures. Polycarbonates used in engineering are strong, tough materials, and some grades are optically transparent. They are easily worke ...


The Fowkes theory

The Fowkes theory (after F. M. Fowkes) is derived in a slightly different way from the Owens/Wendt theory, although the Fowkes theory's principle equation is mathematically equivalent to that of Owens and Wendt: :\frac \sigma_\ (\cos\theta + 1) = \sqrt\sqrt + \sqrt\sqrt Note that by dividing both sides of the equation by \sqrt, the Owens/Wendt principle equation is recovered. As such, one of the options for the proper determination of the surface energy components is the same. In addition to that method, it is also possible to simply do tests using liquids with no polar component to their surface energies, and then liquids that do have both polar and dispersive components, and then linearize the equations (see
table 1 Table may refer to: * Table (furniture), a piece of furniture with a flat surface and one or more legs * Table (landform), a flat area of land * Table (information), a data arrangement with rows and columns * Table (database), how the table data ...
). First, one performs the standard sessile drop contact angle measurement for the solid in question and a liquid with a polar components of zero (\sigma_^ = 0; \sigma_ = \sigma_^) The second step is to use a second probe liquid that has both a dispersive and a polar component to its surface energy, and then solve for the unknowns algebraically. The Fowkes theory generally requires the use of only two probe liquids, as described above, and the recommended ones are
diiodomethane Diiodomethane or methylene iodide, commonly abbreviated "MI", is an organoiodine compound. Diiodomethane is a colorless liquid; however, it decomposes upon exposure to light liberating iodine, which colours samples brownish. It is slightly solub ...
, which should have no polar component due to its molecular symmetry, and
water Water (chemical formula ) is an Inorganic compound, inorganic, transparent, tasteless, odorless, and Color of water, nearly colorless chemical substance, which is the main constituent of Earth's hydrosphere and the fluids of all known living ...
, which is commonly known to be a very polar liquid.


=Accuracy/precision

= Though the principle equation is essentially identical to that of Owens and Wendt, the Fowkes theory in a larger sense has slightly different applications. Because it is derived from different principles than Owens/Wendt, the rest of the information that Fowkes theory is concerned with is related to
adhesion Adhesion is the tendency of dissimilar particles or surfaces to cling to one another ( cohesion refers to the tendency of similar or identical particles/surfaces to cling to one another). The forces that cause adhesion and cohesion can b ...
. As such, it is more applicable to situations where adhesion occurs, and in general works better than does the Owens/Wendt theory when dealing with higher surface energies. In addition, there is an extended Fowkes theory, rooted in the same principles, but dividing the total surface energy into a sum of three rather than two components: surface energy due to dispersive interactions, polar interactions, and hydrogen bonding.


The Wu Theory

The Wu theory (after Souheng Wu) is also essentially similar to the Owens/Wendt and Fowkes theories, in that it divides surface energy into a polar and a dispersive component. The primary difference is that Wu uses the harmonic means rather than the geometric means of the known surface tensions, and subsequently the use of more rigorous mathematics is employed.


=Accuracy/precision

= The Wu theory provides more accurate results than do the other two component theories, particularly for high surface energies. It does, however, suffer from one complication: because of the mathematics involved, the Wu theory yields two results for each component, one being the true result, and one being simply a consequence of the mathematics. The challenge at this point lies in interpreting which is the true result. Sometimes this is as simple as eliminating the result that makes no physical sense (a negative surface energy) or the result that is clearly incorrect by virtue of being many orders of magnitude larger or smaller than it should be. Sometimes interpretation is more tricky.


The Schultz Theory

The Schultz theory (after D. L. Schultz) is applicable only for very high energy solids. Again, it is similar to the theories of Owens, Wendt, Fowkes, and Wu, but is designed for a situation where conventional measurement required for those theories is impossible. In the class of solids with sufficiently high surface energy, most liquids wet the surface completely with a contact angle of zero degrees, and thus no useful data can be gathered. The Schultz theory and procedure calls to deposit a sessile drop of probe liquid on the solid surface in question, but this is all done while the system is submerged in yet another liquid, rather than being done in the open air. As a result, the higher “atmospheric” pressure due to the surrounding liquid causes the probe liquid droplet to compress so that there is a measurable contact angle.


=Accuracy/precision

= This method is designed to be robust where the other methods don't even provide any results in particular. As such, it is indispensable, since it is the only way to use the sessile drop technique on very high surface energy solids. Its major drawback is the fact that it is far more complex, both in its mathematics and experimentally. The Schultz theory requires one to account for many more factors, as there is now the unusual interaction of the probe liquid phase with the surrounding liquid .


Three component theories


The van Oss theory

The van Oss theory separates the surface energy of solids and liquids into three components. It includes the dispersive surface energy, as before, and subdivides the polar component as being the sum of two more specific components: the surface energy due to
acidic In computer science, ACID ( atomicity, consistency, isolation, durability) is a set of properties of database transactions intended to guarantee data validity despite errors, power failures, and other mishaps. In the context of databases, a ...
interactions (\sigma^+) and due to basic interactions (\sigma^-). The acid component theoretically describes a surface's propensity to have polar interactions with a second surface that has the ability to act basic by donating electrons. Conversely, the base component of the surface energy describes the propensity of a surface to have polar interactions with another surface that acts acidic by accepting electrons. The principle equation for this theory is: :\sigma_(\cos\theta + 1) = 2\left sqrt + \sqrt + \sqrt\right/math> Again, the best way to deal with this theory, much like the two component theories, is to use at least three liquids (more can be used to get more results for statistical purposes) – one with only a dispersive component to its surface energy (\sigma_ = \sigma_^), one with only a dispersive and an acidic or basic component (\sigma_ = \sigma_L^ + \sigma_^\pm ), and finally either a liquid with a dispersive and a basic or acidic component (whichever the second probe liquid did ''not'' have (\sigma_ = \sigma_^ + \sigma_^\mp )), or a liquid with all three components (\sigma_ = \sigma_^ + \sigma_^+ + \sigma_^- ) – and linearizing the results. s naturally more robust than other theories, particularly in cases where there is a great imbalance between the acid and base components of the polar surface energy. The van Oss theory is most suitable for testing the surface energies of inorganics, organometallics, and surface containing ions. The most significant difficulty of applying the van Oss theory is the fact that there is not much of an agreement in regards to a set of reference solids that can be used to characterize the acid and base components of potential probe liquids. There are however some liquids that are generally agreed to have known dispersive/acid/base components to their surface energies. Two of them are listed in
table 1 Table may refer to: * Table (furniture), a piece of furniture with a flat surface and one or more legs * Table (landform), a flat area of land * Table (information), a data arrangement with rows and columns * Table (database), how the table data ...
.


List of common probe liquids

{, class="wikitable" border="1" , - ! Liquid ! Total surface tension
(mJ/m2) ! Dispersive component
(mJ/m2) ! Polar component
(mJ/m2) ! Acid component
(mJ/m2) ! Base component
(mJ/m2) , - ,
Formamide Formamide is an amide derived from formic acid. It is a colorless liquid which is miscible with water and has an ammonia-like odor. It is chemical feedstock for the manufacture of sulfa drugs and other pharmaceuticals, herbicides and pesticides, a ...
, 58.0 , 39.0 , 19.0 , 2.28 , 16.72 , - ,
Diiodomethane Diiodomethane or methylene iodide, commonly abbreviated "MI", is an organoiodine compound. Diiodomethane is a colorless liquid; however, it decomposes upon exposure to light liberating iodine, which colours samples brownish. It is slightly solub ...
, 50.8 , 50.8 , 0 , 0 , 0 , - ,
Water Water (chemical formula ) is an Inorganic compound, inorganic, transparent, tasteless, odorless, and Color of water, nearly colorless chemical substance, which is the main constituent of Earth's hydrosphere and the fluids of all known living ...
, 72.8 , 26.4 , 46.4 , 23.2 , 23.2


Potential problems

The presence of surface active elements such as oxygen and sulfur will have a large impact on the measurements obtained with this technique. Surface active elements will exist in larger concentrations at the surface than in the bulk of the liquid, meaning that the total levels of these elements must be carefully controlled to a very low level. For example, the presence of only 50 ppm sulphur in liquid iron will reduce the surface tension by approximately 20%.Seshadri Seetharaman: Fundamentals of metallurgy, Woodhead Publishing in Materials, Cambridge, 2005.


Practical applications

The sessile drop technique has various applications for both materials engineering and straight characterization. In general, it is useful in determining the surface tension of liquids through the use of reference solids, with a similar technique being the Captive Bubble Method. There are various other specific applications which can be subdivided according to which of the above theories is most likely to be applicable to the circumstances: The Zisman theory is mostly used for low energy surfaces and characterizes only the total surface energy. As such, it is probably most useful in cases that recall the conventional definition of surfaces, for example if a chemical engineer wants to know what the energy associated with fabricating a surface is. It may also be useful in cases where the surface energy has some effect on a
spectroscopic Spectroscopy is the field of study that measures and interprets the electromagnetic spectra that result from the interaction between electromagnetic radiation and matter as a function of the wavelength or frequency of the radiation. Matter wa ...
technique being used on the solid in question. The two component theories would most likely be applicable to materials engineering questions about the practical interactions of liquids and solids. The Fowkes theory, since it is more suited for higher energy solid surfaces, and since much of it is rooted in theories about
adhesion Adhesion is the tendency of dissimilar particles or surfaces to cling to one another ( cohesion refers to the tendency of similar or identical particles/surfaces to cling to one another). The forces that cause adhesion and cohesion can b ...
, would likely be suited for the characterization of interactions where the solids and liquids have a high affinity for one another, such as, logically enough,
adhesives Adhesive, also known as glue, cement, mucilage, or paste, is any non-metallic substance applied to one or both surfaces of two separate items that binds them together and resists their separation. The use of adhesives offers certain advant ...
and adhesive
coatings A coating is a covering that is applied to the surface of an object, usually referred to as the substrate. The purpose of applying the coating may be decorative, functional, or both. Coatings may be applied as liquids, gases or solids e.g. Powd ...
. The Owens/Wendt theory, which deals in low energy solid surfaces, would be helpful in characterizing the interactions where the solids and liquids do ''not'' have a strong affinity for one another – for example, the effectiveness of
waterproofing Waterproofing is the process of making an object or structure waterproof or water-resistant so that it remains relatively unaffected by water or resisting the ingress of water under specified conditions. Such items may be used in wet environme ...
. Polyurethanes and PVC are good examples of waterproof plastics. The Schultz theory is best used for the characterization of very high energy surfaces for which the other theories are ineffective, the most significant example being bare
metals A metal (from Greek μέταλλον ''métallon'', "mine, quarry, metal") is a material that, when freshly prepared, polished, or fractured, shows a lustrous appearance, and conducts electricity and heat relatively well. Metals are typical ...
. The van Oss theory is most suitable for cases in which acid/base interaction is an important consideration. Examples include
pigments A pigment is a colored material that is completely or nearly insoluble in water. In contrast, dyes are typically soluble, at least at some stage in their use. Generally dyes are often organic compounds whereas pigments are often inorganic compoun ...
, pharmaceuticals, and
paper Paper is a thin sheet material produced by mechanically or chemically processing cellulose fibres derived from wood, rags, grasses or other vegetable sources in water, draining the water through fine mesh leaving the fibre evenly distrib ...
. Specifically, notable examples include both paper used for the regular purpose of printing, and the more specialized case of
litmus paper Litmus is a water-soluble mixture of different dyes extracted from lichens. It is often absorbed onto filter paper to produce one of the oldest forms of pH indicator, used to test materials for acidity. It is a purple dye that is extracte ...
, which in itself is used to characterize acidity and basicity.


See also

*
Contact angle The contact angle is the angle, conventionally measured through the liquid, where a liquid–vapor interface meets a solid surface. It quantifies the wettability of a solid surface by a liquid via the Young equation. A given system of solid, liq ...
* Du Noüy ring method * Goniometer * Surface energy *
Wilhelmy plate A Wilhelmy plate is a thin plate that is used to measure equilibrium surface or interfacial tension at an air–liquid or liquid–liquid interface. In this method, the plate is oriented perpendicular to the interface, and the force exerted on ...
* Rise in core


References


External links


Contact angle
Materials testing Surface science