Indoor air quality (IAQ) is the
air quality
Air pollution is the contamination of air due to the presence of substances in the atmosphere that are harmful to the health of humans and other living beings, or cause damage to the climate or to materials. There are many different types ...
within and around
building
A building, or edifice, is an enclosed structure with a roof and walls standing more or less permanently in one place, such as a house or factory (although there's also portable buildings). Buildings come in a variety of sizes, shapes, and fun ...
s and
structure
A structure is an arrangement and organization of interrelated elements in a material object or system, or the object or system so organized. Material structures include man-made objects such as buildings and machines and natural objects such as ...
s. IAQ is known to affect the health, comfort, and well-being of building occupants. Poor indoor air quality has been linked to
sick building syndrome
Sick building syndrome (SBS) is an unsubstantiated diagnosis where health problems are attributed to buildings. The cause of the health problems are unknown.
Symptoms attributed to SBS may or may not be a direct result of inadequate cleaning or ...
, reduced productivity, and impaired learning in schools. Common pollutants of indoor air include:
Secondhand tobacco smoke,
air pollutants from indoor combustion,
radon
Radon is a chemical element with the symbol Rn and atomic number 86. It is a radioactive, colourless, odourless, tasteless noble gas. It occurs naturally in minute quantities as an intermediate step in the normal radioactive decay chains through ...
,
molds and other
allergens,
carbon monoxide
Carbon monoxide (chemical formula CO) is a colorless, poisonous, odorless, tasteless, flammable gas that is slightly less dense than air. Carbon monoxide consists of one carbon atom and one oxygen atom connected by a triple bond. It is the simple ...
,
volatile organic compounds
Volatile organic compounds (VOCs) are organic compounds that have a high vapour pressure at room temperature
Colloquially, "room temperature" is a range of air temperatures that most people prefer for indoor settings. It feels comfortable to a ...
,
legionella
''Legionella'' is a genus of pathogenic gram-negative bacteria that includes the species '' L. pneumophila'', causing legionellosis (all illnesses caused by ''Legionella'') including a pneumonia-type illness called Legionnaires' disease and a mil ...
and other bacteria,
asbestos fibers
Asbestos () is a naturally occurring fibrous silicate mineral. There are six types, all of which are composed of long and thin fibrous crystals, each fibre being composed of many microscopic "fibrils" that can be released into the atmosphere b ...
,
carbon dioxide
Carbon dioxide (chemical formula ) is a chemical compound made up of molecules that each have one carbon atom covalently double bonded to two oxygen atoms. It is found in the gas state at room temperature. In the air, carbon dioxide is transpar ...
,
ozone
Ozone (), or trioxygen, is an inorganic molecule with the chemical formula . It is a pale blue gas with a distinctively pungent smell. It is an allotrope of oxygen that is much less stable than the diatomic allotrope , breaking down in the lo ...
and
particulates
Particulates – also known as atmospheric aerosol particles, atmospheric particulate matter, particulate matter (PM) or suspended particulate matter (SPM) – are microscopic particles of solid or liquid matter suspended in the air. The ter ...
. Source control, filtration, and the use of
ventilation
Ventilation may refer to:
* Ventilation (physiology), the movement of air between the environment and the lungs via inhalation and exhalation
** Mechanical ventilation, in medicine, using artificial methods to assist breathing
*** Ventilator, a m ...
to dilute contaminants are the primary methods for improving indoor air quality in most buildings.
Determination of IAQ involves the collection of air samples, monitoring human exposure to pollutants, collection of samples on building surfaces, and computer modelling of air flow inside buildings. IAQ is part of
indoor environmental quality (IEQ), which includes IAQ as well as other physical and psychological aspects of life indoors (e.g., lighting, visual quality, acoustics, and thermal comfort).
Indoor workplaces are found in many working environments such as offices, sales areas, hospitals, libraries, schools and preschool childcare facilities. At such workplaces, no tasks involving hazardous substances are performed, and they do not include high-noise areas. Nevertheless, employees may feature symptoms belonging to the sick building syndrome such as burning of the eyes, scratchy throat, blocked nose, and headaches. These afflictions often cannot be attributed to a single cause, and require a comprehensive analysis besides the testing of the air quality. Factors such as the workplace design, lighting, noise, thermal environment, ionising radiation and psychological and mental aspects have as well to be allowed for. A report assisted by the
can support in the systematic investigation of individual health problems arising at indoor workplaces, and in the identification of practical solutions.
Indoor air pollution is a major health hazard in
developing countries
A developing country is a sovereign state with a lesser developed industrial base and a lower Human Development Index (HDI) relative to other countries. However, this definition is not universally agreed upon. There is also no clear agreem ...
and is commonly referred to as "
household air pollution
Household air pollution (HAP) is a significant form of indoor air pollution mostly relating to cooking and heating methods used in developing countries. Since much of the cooking is carried out with biomass fuel, in the form of wood, charcoal, ...
" in that context. It is mostly relating to cooking and heating methods by burning
biomass fuel, in the form of
wood
Wood is a porous and fibrous structural tissue found in the stems and roots of trees and other woody plants. It is an organic materiala natural composite of cellulose fibers that are strong in tension and embedded in a matrix of lignin th ...
,
charcoal
Charcoal is a lightweight black carbon residue produced by strongly heating wood (or other animal and plant materials) in minimal oxygen to remove all water and volatile constituents. In the traditional version of this pyrolysis process, cal ...
,
dung, and
crop residue
Crop residues are materials left in an agricultural field after the crop has been harvested. These residues include stalks and stubble (stems), leaves and seed pods. Good management of field residues can increase efficiency of irrigation and c ...
, in indoor environments that lack proper ventilation. Millions of people, primarily women and children face serious health risks. In total, about three billion people in developing countries are affected by this problem. The
World Health Organization
The World Health Organization (WHO) is a specialized agency of the United Nations responsible for international public health. The WHO Constitution states its main objective as "the attainment by all peoples of the highest possible level of h ...
(WHO) estimates that cooking-related indoor air pollution causes 3.8 million annual deaths. The
Global Burden of Disease study estimated the number of deaths in 2017 at 1.6 million.
Common pollutants
Secondhand tobacco smoke
Secondhand smoke
Passive smoking is the inhalation of tobacco smoke, called secondhand smoke (SHS), or environmental tobacco smoke (ETS), by persons other than the intended "active" smoker. It occurs when tobacco smoke enters an environment, causing its inhalat ...
is tobacco smoke which affects people other than the 'active' smoker. Second-hand tobacco smoke includes both a
gas
Gas is one of the four fundamental states of matter (the others being solid, liquid, and plasma).
A pure gas may be made up of individual atoms (e.g. a noble gas like neon), elemental molecules made from one type of atom (e.g. oxygen), or ...
eous and a
particulate
Particulates – also known as atmospheric aerosol particles, atmospheric particulate matter, particulate matter (PM) or suspended particulate matter (SPM) – are microscopic particles of solid or liquid matter suspended in the air. The te ...
phase, with particular hazards arising from levels of
carbon monoxide
Carbon monoxide (chemical formula CO) is a colorless, poisonous, odorless, tasteless, flammable gas that is slightly less dense than air. Carbon monoxide consists of one carbon atom and one oxygen atom connected by a triple bond. It is the simple ...
(as indicated below) and very small particulates (fine particular matter at especially PM2.5 size, and PM10) which get into the
bronchiole
The bronchioles or bronchioli (pronounced ''bron-kee-oh-lee'') are the smaller branches of the bronchial airways in the lower respiratory tract. They include the terminal bronchioles, and finally the respiratory bronchioles that mark the start ...
s and
alveoles in the lung. The only certain method to improve indoor air quality as regards secondhand smoke is to eliminate smoking indoors. Indoor e-cigarette use also increases home
particulate matter concentrations.
Air pollutants from indoor combustion
Indoor combustion, such as for cooking or heating, is a major cause of indoor air pollution and causes significant health harms and premature deaths. Hydrocarbon fires cause air pollution. Pollution is caused by both biomass and fossil fuels of various types, but some forms of fuels are more harmful than others. Indoor fire can produce black carbon particles, nitrogen oxides, sulfur oxides, and mercury compounds, among other emissions. Around 3 billion people cook over open fires or on rudimentary cook stoves. Cooking fuels are coal, wood, animal dung, and crop residues.
Radon
Radon
Radon is a chemical element with the symbol Rn and atomic number 86. It is a radioactive, colourless, odourless, tasteless noble gas. It occurs naturally in minute quantities as an intermediate step in the normal radioactive decay chains through ...
is an invisible, radioactive atomic gas that results from the radioactive decay of
radium
Radium is a chemical element with the symbol Ra and atomic number 88. It is the sixth element in group 2 of the periodic table, also known as the alkaline earth metals. Pure radium is silvery-white, but it readily reacts with nitrogen (rather t ...
, which may be found in rock formations beneath buildings or in certain building materials themselves. Radon is probably the most pervasive serious hazard for indoor air in the United States and Europe, and is probably responsible for tens of thousands of deaths from lung cancer each year. There are relatively simple test kits for do-it-yourself radon gas testing, but if a home is for sale the testing must be done by a licensed person in some U.S. states. Radon gas enters buildings as a
soil gas Soil gases (soil atmosphere) are the gases found in the air space between soil components. The spaces between the solid soil particles, if they do not contain water, are filled with air. The primary soil gases are nitrogen, carbon dioxide and oxygen ...
and is a heavy gas and thus will tend to accumulate at the lowest level. Radon may also be introduced into a building through drinking water particularly from bathroom showers. Building materials can be a rare source of radon, but little testing is carried out for stone, rock or tile products brought into building sites; radon accumulation is greatest for well insulated homes. The half life for radon is 3.8 days, indicating that once the source is removed, the hazard will be greatly reduced within a few weeks.
Radon mitigation
Radon mitigation is any process used to reduce radon gas concentrations in the breathing zones of occupied buildings, or radon from water supplies. Radon is a significant contributor to environmental radioactivity and can cause serious health pr ...
methods include sealing concrete slab floors, basement foundations, water drainage systems, or by increasing
ventilation
Ventilation may refer to:
* Ventilation (physiology), the movement of air between the environment and the lungs via inhalation and exhalation
** Mechanical ventilation, in medicine, using artificial methods to assist breathing
*** Ventilator, a m ...
. They are usually cost effective and can greatly reduce or even eliminate the contamination and the associated health risks.
Radon is measured in picocuries per liter of air (pCi/L), a measurement of radioactivity. In the United States, the average indoor radon level is about 1.3 pCi/L. The average outdoor level is about 0.4 pCi/L. The U.S. Surgeon General and EPA recommend fixing homes with radon levels at or above 4 pCi/L. EPA also recommends that people think about fixing their homes for radon levels between 2 pCi/L and 4 pCi/L.
Molds and other allergens
These biological chemicals can arise from a host of means, but there are two common classes: (a) moisture induced growth of mold colonies and (b) natural substances released into the air such as animal dander and plant pollen. Mold is always associated with moisture, and its growth can be inhibited by keeping humidity levels below 50%. Moisture buildup inside buildings may arise from water penetrating compromised areas of the building envelope or skin, from plumbing leaks, from
condensation
Condensation is the change of the state of matter from the gas phase into the liquid phase, and is the reverse of vaporization. The word most often refers to the water cycle. It can also be defined as the change in the state of water vapor to ...
due to improper ventilation, or from ground moisture penetrating a building part. Even something as simple as drying clothes indoors on
radiators
Radiators are heat exchangers used to transfer thermal energy from one medium to another for the purpose of cooling and heating. The majority of radiators are constructed to function in cars, buildings, and electronics.
A radiator is always a ...
can increase the risk of exposure to (amongst other things)
Aspergillus
' () is a genus consisting of several hundred mold species found in various climates worldwide.
''Aspergillus'' was first catalogued in 1729 by the Italian priest and biologist Pier Antonio Micheli. Viewing the fungi under a microscope, Miche ...
– a highly dangerous mould that can be fatal for asthma sufferers and the elderly. In areas where cellulosic materials (paper and wood, including drywall) become moist and fail to dry within 48 hours, mold mildew can propagate and release allergenic spores into the air.
In many cases, if materials have failed to dry out several days after the suspected water event, mold growth is suspected within wall cavities even if it is not immediately visible. Through a mold investigation, which may include destructive inspection, one should be able to determine the presence or absence of mold. In a situation where there is visible mold and the indoor air quality may have been compromised, mold remediation may be needed. Mold testing and inspections should be carried out by an independent investigator to avoid any conflict of interest and to insure accurate results.
There are some varieties of mold that contain toxic compounds (mycotoxins). However, exposure to hazardous levels of mycotoxin via inhalation is not possible in most cases, as toxins are produced by the fungal body and are not at significant levels in the released spores. The primary hazard of mold growth, as it relates to indoor air quality, comes from the allergenic properties of the spore cell wall. More serious than most allergenic properties is the ability of mold to trigger episodes in persons that already have
asthma
Asthma is a long-term inflammatory disease of the airways of the lungs. It is characterized by variable and recurring symptoms, reversible airflow obstruction, and easily triggered bronchospasms. Symptoms include episodes of wheezing, cou ...
, a serious respiratory disease.
Carbon monoxide
One of the most acutely toxic indoor air contaminants is
carbon monoxide
Carbon monoxide (chemical formula CO) is a colorless, poisonous, odorless, tasteless, flammable gas that is slightly less dense than air. Carbon monoxide consists of one carbon atom and one oxygen atom connected by a triple bond. It is the simple ...
(CO), a colourless and odourless gas that is a by-product of incomplete
combustion
Combustion, or burning, is a high-temperature exothermic redox chemical reaction between a fuel (the reductant) and an oxidant, usually atmospheric oxygen, that produces oxidized, often gaseous products, in a mixture termed as smoke. Combusti ...
. Common sources of carbon monoxide are tobacco smoke, space heaters using
fossil fuels
A fossil fuel is a hydrocarbon-containing material formed naturally in the Earth's crust from the remains of dead plants and animals that is extracted and burned as a fuel. The main fossil fuels are coal, oil, and natural gas. Fossil fuels ...
, defective central heating furnaces and automobile exhaust. By depriving the brain of oxygen, high levels of carbon monoxide can lead to nausea, unconsciousness and death. According to the
American Conference of Governmental Industrial Hygienists
The American Conference of Governmental Industrial Hygienists (ACGIH) is a professional association of industrial hygienists and practitioners of related professions, with headquarters in Cincinnati, Ohio. One of its goals is to advance worker pr ...
(ACGIH), the time-weighted average (TWA) limit for carbon monoxide (630–08–0) is 25
ppm.
Volatile organic compounds
Volatile organic compound
Volatile organic compounds (VOCs) are organic compounds that have a high vapour pressure at room temperature. High vapor pressure correlates with a low boiling point, which relates to the number of the sample's molecules in the surrounding air, a ...
s (VOCs) are emitted as gases from certain solids or liquids. VOCs include a variety of chemicals, some of which may have short- and long-term adverse health effects. Concentrations of many VOCs are consistently higher indoors (up to ten times higher) than outdoors. VOCs are emitted by a wide array of products numbering in the thousands. Examples include: paints and lacquers, paint strippers, cleaning supplies, pesticides, building materials and furnishings, office equipment such as copiers and printers,
correction fluid
A correction fluid is an opaque, usually white fluid applied to paper to mask errors in text. Once dried, it can be handwritten or typed upon. It is typically packaged in small bottles, lids attached to brushes (or triangular pieces of foam) th ...
s and
carbonless copy paper
Carbonless copy paper (CCP), non-carbon copy paper, or NCR paper (No Carbon Required, taken from the initials of its creator, National Cash Register) is a type of coated paper designed to transfer information written on the front onto sheets beneat ...
, graphics and craft materials including glues and adhesives, permanent markers, and photographic solutions.
Chlorinated drinking water releases chloroform when hot water is used in the home. Benzene is emitted from fuel stored in attached garages. Overheated cooking oils emit acrolein and formaldehyde. A meta-analysis of 77 surveys of VOCs in homes in the US found the top ten riskiest indoor air VOCs were acrolein, formaldehyde, benzene, hexachlorobutadiene, acetaldehyde, 1,3-butadiene, benzyl chloride, 1,4-dichlorobenzene, carbon tetrachloride, acrylonitrile, and vinyl chloride. These compounds exceeded health standards in most homes.
Organic chemicals are widely used as ingredients in household products. Paints, varnishes, and wax all contain organic solvents, as do many cleaning, disinfecting, cosmetic, degreasing, and hobby products. Fuels are made up of organic chemicals. All of these products can release organic compounds during usage, and, to some degree, when they are stored. Testing emissions from building materials used indoors has become increasingly common for floor coverings, paints, and many other important indoor building materials and finishes.
Indoor materials such as gypsum boards or carpet act as VOC 'sinks', by trapping VOC vapors for extended periods of time, and releasing them by
outgassing
Outgassing (sometimes called offgassing, particularly when in reference to indoor air quality) is the release of a gas that was dissolved, trapped, frozen, or absorbed in some material. Outgassing can include sublimation and evaporation (which a ...
. This can result in chronic and low-level exposures to VOCs.
Several initiatives envisage to reduce indoor air contamination by limiting VOC emissions from products. There are regulations in France and in Germany, and numerous voluntary ecolabels and rating systems containing low VOC emissions criteria such as
EMICODE, M1,
Blue Angel and
Indoor Air Comfort
Indoor(s) may refer to:
*the interior of a building
*Indoor environment, in building science, traditionally includes the study of indoor thermal environment, indoor acoustic environment, indoor light environment, and indoor air quality
*Built envi ...
in Europe, as well as California Standard CDPH Section 01350 and several others in the US. These initiatives changed the marketplace where an increasing number of low-emitting products has become available during the last decades.
At least 18 Microbial VOCs (MVOCs) have been characterised
including
1-octen-3-ol,
3-methylfuran,
2-pentanol
2-Pentanol (IUPAC name: pentan-2-ol; also called ''sec''-amyl alcohol) is an organic chemical compound. It is used as a solvent and an intermediate in the manufacturing of other chemicals. 2-Pentanol is a component of many mixtures of amyl alcoho ...
,
2-hexanone,
2-heptanone,
3-octanone,
3-octanol,
2-octen-1-ol,
1-octene,
2-pentanone,
2-nonanone,
borneol
Borneol is a bicyclic organic compound and a terpene derivative. The hydroxyl group in this compound is placed in an '' endo'' position. The exo diastereomer is called isoborneol. Being chiral, borneol exists as enantiomers, both of which are foun ...
,
geosmin
Geosmin ( ) is an irregular sesquiterpenoid, produced from the universal sesquiterpene precursor farnesyl pyrophosphate (also known as farnesyl diphosphate), in a two-step -dependent reaction. Geosmin, along with the irregular monoterpene 2-met ...
,
1-butanol,
3-methyl-1-butanol
Isoamyl alcohol is a colorless liquid with the formula , specifically (H3C–)2CH–CH2–CH2–OH. It is one of several isomers of amyl alcohol (pentanol). It is also known as isopentyl alcohol, isopentanol, or (in the IUPAC recommended nomencla ...
,
3-methyl-2-butanol
3-Methyl-2-butanol (IUPAC name, commonly called ''sec''-isoamyl alcohol) is an organic chemical compound. It is used as a solvent and an intermediate in the manufacture of other chemicals. The compound is one of the eight isomers of pentyl alcoho ...
, and
thujopsene
Thujopsene is a natural chemical compound, classified as a sesquiterpene, with the molecular formula C15H24.
Thujopsene is found in the essential oil of a variety of conifers, in particular '' Juniperus cedrus'' and '' Thujopsis dolabrata'' i ...
. The first of these compounds is called mushroom alcohol. The last four are products of ''
Stachybotrys chartarum'', which has been linked with
sick building syndrome
Sick building syndrome (SBS) is an unsubstantiated diagnosis where health problems are attributed to buildings. The cause of the health problems are unknown.
Symptoms attributed to SBS may or may not be a direct result of inadequate cleaning or ...
.
Legionella
Legionnaires' disease
Legionnaires' disease is a form of atypical pneumonia caused by any species of ''Legionella'' bacteria, quite often '' Legionella pneumophila''. Signs and symptoms include cough, shortness of breath, high fever, muscle pains, and headaches. Naus ...
is caused by a waterborne bacterium ''
Legionella
''Legionella'' is a genus of pathogenic gram-negative bacteria that includes the species '' L. pneumophila'', causing legionellosis (all illnesses caused by ''Legionella'') including a pneumonia-type illness called Legionnaires' disease and a mil ...
'' that grows best in slow-moving or still, warm water. The primary route of exposure is through the creation of an aerosol effect, most commonly from evaporative cooling towers or showerheads. A common source of Legionella in commercial buildings is from poorly placed or maintained evaporative cooling towers, which often release water in an aerosol which may enter nearby ventilation intakes. Outbreaks in medical facilities and nursing homes, where patients are immuno-suppressed and immuno-weak, are the most commonly reported cases of Legionellosis. More than one case has involved outdoor fountains in public attractions. The presence of Legionella in commercial building water supplies is highly under-reported, as healthy people require heavy exposure to acquire infection.
Legionella testing typically involves collecting water samples and surface swabs from evaporative cooling basins, shower heads, faucets/taps, and other locations where warm water collects. The samples are then cultured and colony forming units (cfu) of Legionella are quantified as cfu/Liter.
Legionella is a parasite of protozoans such as
amoeba
An amoeba (; less commonly spelled ameba or amœba; plural ''am(o)ebas'' or ''am(o)ebae'' ), often called an amoeboid, is a type of Cell (biology), cell or unicellular organism with the ability to alter its shape, primarily by extending and ret ...
, and thus requires conditions suitable for both organisms. The bacterium forms a
biofilm
A biofilm comprises any syntrophic consortium of microorganisms in which cells stick to each other and often also to a surface. These adherent cells become embedded within a slimy extracellular matrix that is composed of extracellular ...
which is resistant to chemical and antimicrobial treatments, including chlorine. Remediation for Legionella outbreaks in commercial buildings vary, but often include very hot water flushes (160 °F; 70 °C), sterilisation of standing water in evaporative cooling basins, replacement of shower heads, and in some cases flushes of heavy metal salts. Preventive measures include adjusting normal hot water levels to allow for 120 °F (50 °C) at the tap, evaluating facility design layout, removing faucet aerators, and periodic testing in suspect areas.
Other bacteria
There are many
bacteria
Bacteria (; singular: bacterium) are ubiquitous, mostly free-living organisms often consisting of one biological cell. They constitute a large domain of prokaryotic microorganisms. Typically a few micrometres in length, bacteria were among ...
of health significance found in indoor air and on indoor surfaces. The role of microbes in the indoor environment is increasingly studied using modern gene-based analysis of environmental samples. Currently efforts are under way to link microbial ecologists and indoor air scientists to forge new methods for analysis and to better interpret the results.
"There are approximately ten times as many bacterial cells in the human flora as there are human cells in the body, with large numbers of bacteria on the skin and as gut flora." A large fraction of the bacteria found in indoor air and dust are shed from humans. Among the most important bacteria known to occur in indoor air are
Mycobacterium tuberculosis
''Mycobacterium tuberculosis'' (M. tb) is a species of pathogenic bacteria in the family Mycobacteriaceae and the causative agent of tuberculosis. First discovered in 1882 by Robert Koch, ''M. tuberculosis'' has an unusual, waxy coating on its c ...
,
Staphylococcus aureus
''Staphylococcus aureus'' is a Gram-positive spherically shaped bacterium, a member of the Bacillota, and is a usual member of the microbiota of the body, frequently found in the upper respiratory tract and on the skin. It is often positive ...
,
Streptococcus pneumoniae
''Streptococcus pneumoniae'', or pneumococcus, is a Gram-positive, spherical bacteria, alpha-hemolytic (under aerobic conditions) or beta-hemolytic (under anaerobic conditions), aerotolerant anaerobic member of the genus Streptococcus. They are ...
.
Asbestos fibers
Many common building materials used before 1975 contain
asbestos
Asbestos () is a naturally occurring fibrous silicate mineral. There are six types, all of which are composed of long and thin fibrous crystals, each fibre being composed of many microscopic "fibrils" that can be released into the atmosphere b ...
, such as some floor tiles, ceiling tiles, shingles, fireproofing, heating systems, pipe wrap, taping muds, mastics, and other insulation materials. Normally, significant releases of asbestos fiber do not occur unless the building materials are disturbed, such as by cutting, sanding, drilling, or building remodelling. Removal of asbestos-containing materials is not always optimal because the fibers can be spread into the air during the removal process. A management program for intact asbestos-containing materials is often recommended instead.
When asbestos-containing material is damaged or disintegrates, microscopic fibers are dispersed into the air. Inhalation of asbestos fibers over long exposure times is associated with increased incidence of
lung cancer
Lung cancer, also known as lung carcinoma (since about 98–99% of all lung cancers are carcinomas), is a malignant lung tumor characterized by uncontrolled cell growth in tissue (biology), tissues of the lung. Lung carcinomas derive from tran ...
, in particular the specific form
mesothelioma
Mesothelioma is a type of cancer that develops from the thin layer of tissue that covers many of the internal organs (known as the mesothelium). The most common area affected is the lining of the lungs and chest wall. Less commonly the lining ...
. The risk of lung cancer from inhaling asbestos fibers is significantly greater to smokers, however there is no confirmed connection to damage caused by asbestosis . The symptoms of the disease do not usually appear until about 20 to 30 years after the first exposure to asbestos.
Asbestos
Asbestos () is a naturally occurring fibrous silicate mineral. There are six types, all of which are composed of long and thin fibrous crystals, each fibre being composed of many microscopic "fibrils" that can be released into the atmosphere b ...
is found in older homes and buildings, but occurs most commonly in schools, hospitals and industrial settings. Although all asbestos is hazardous, products that are friable, e.g. sprayed coatings and insulation, pose a significantly higher hazard as they are more likely to release fibers to the air. The US Federal Government and some states have set standards for acceptable levels of asbestos fibers in indoor air. There are particularly stringent regulations applicable to schools.
Carbon dioxide
According to
ASHRAE
The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE ) is an American professional association seeking to advance heating, ventilation, air conditioning and refrigeration (HVAC&R) systems design and constructio ...
, "Existing evidence for direct impacts of
Carbon dioxide
Carbon dioxide (chemical formula ) is a chemical compound made up of molecules that each have one carbon atom covalently double bonded to two oxygen atoms. It is found in the gas state at room temperature. In the air, carbon dioxide is transpar ...
(CO
2) on health, well-being, learning outcomes, and work performance at commonly observed indoor concentrations is inconsistent, and therefore does not currently justify changes to ventilation and IAQ standards, regulations, or guidelines."
NASA
The National Aeronautics and Space Administration (NASA ) is an independent agency of the US federal government responsible for the civil space program, aeronautics research, and space research.
NASA was established in 1958, succeeding t ...
noted research on the CO
2 levels found on submarines or spacecraft (of 3000ppm-7000ppm) had found it didn't affect the performance of astronaughts or submarine officers. However, they decided to limit it to 5000ppm to avoid headaches. Whereas in non-specialised populations, pure CO
2 at a concentration common in indoor environments was found to affect high-level decision-making.
Moreover, it is a relatively easy to measure surrogate for indoor pollutants emitted by humans, and correlates with human metabolic activity. Humans are the main indoor source of carbon dioxide in most buildings. Indoor CO
2 levels are an indicator of the adequacy of outdoor air ventilation relative to indoor occupant density and metabolic activity.
To eliminate most complaints, the total indoor CO
2 level should be reduced to a difference of no greater than 700 ppm above outdoor levels. The USA
National Institute for Occupational Safety and Health (NIOSH) considers that indoor air concentrations of carbon dioxide that exceed 1,000
ppm are a marker suggesting inadequate ventilation. The UK standards for schools say that carbon dioxide in all teaching and learning spaces, when measured at seated head height and averaged over the whole day should not exceed 1,500 ppm. The whole day refers to normal school hours (i.e. 9:00am to 3:30pm) and includes unoccupied periods such as lunch breaks. In Hong Kong, the EPD established indoor air quality objectives for office buildings and public places in which a carbon dioxide level below 1,000 ppm is considered to be good.
European standards limit carbon dioxide to 3,500 ppm.
OSHA
OSHA or Osha may refer to:
Work
* Occupational Safety and Health Administration, a federal agency of the United States that regulates workplace safety and health
* Occupational Safety and Health Act (United States) of 1970, a federal law in the Un ...
limits carbon dioxide concentration in the workplace to 5,000 ppm for prolonged periods, and 35,000 ppm for 15 minutes.
Carbon dioxide concentrations increase as a result of human occupancy, but lag in time behind cumulative occupancy and intake of fresh air. The lower the air exchange rate, the slower the buildup of carbon dioxide to quasi "steady state" concentrations on which the NIOSH and UK guidance are based. Therefore, measurements of carbon dioxide for purposes of assessing the adequacy of ventilation need to be made after an extended period of steady occupancy and ventilation – in schools at least 2 hours, and in offices at least 3 hours – for concentrations to be a reasonable indicator of ventilation adequacy. Portable instruments used to measure carbon dioxide should be calibrated frequently, and outdoor measurements used for calculations should be made close in time to indoor measurements. Corrections for temperature effects on measurements made outdoors may also be necessary.
Carbon dioxide concentrations in closed or confined rooms can increase to 1,000 ppm within 45 minutes of enclosure. For example, in a sized office, atmospheric carbon dioxide increased from 500 ppm to over 1,000 ppm within 45 minutes of ventilation cessation and closure of windows and doors.
Ozone
Ozone
Ozone (), or trioxygen, is an inorganic molecule with the chemical formula . It is a pale blue gas with a distinctively pungent smell. It is an allotrope of oxygen that is much less stable than the diatomic allotrope , breaking down in the lo ...
is produced by
ultraviolet light
Ultraviolet (UV) is a form of electromagnetic radiation with wavelength from 10 nm (with a corresponding frequency around 30 PHz) to 400 nm (750 THz), shorter than that of visible light, but longer than X-rays. UV radiation i ...
from the Sun hitting the Earth's atmosphere (especially in the
ozone layer
The ozone layer or ozone shield is a region of Earth's stratosphere that absorbs most of the Sun's ultraviolet radiation. It contains a high concentration of ozone (O3) in relation to other parts of the atmosphere, although still small in rela ...
),
lightning
Lightning is a naturally occurring electrostatic discharge during which two electric charge, electrically charged regions, both in the atmosphere or with one on the land, ground, temporarily neutralize themselves, causing the instantaneous ...
, certain
high-voltage
High voltage electricity refers to electrical potential large enough to cause injury or damage. In certain industries, ''high voltage'' refers to voltage above a certain threshold. Equipment and Electrical conductor, conductors that carry high ...
electric devices (such as
air ionizer
An air ioniser (or negative ion generator or Chizhevsky's chandelier) is a device that uses high voltage to ionise (electrically charge) air molecules. Negative ions, or anions, are particles with one or more extra electrons, conferring a net ...
s), and as a by-product of other types of pollution.
Ozone exists in greater concentrations at altitudes commonly flown by passenger jets. Reactions between ozone and onboard substances, including skin oils and cosmetics, can produce toxic chemicals as by-products. Ozone itself is also irritating to lung tissue and harmful to human health.
Outdoor air used for ventilation may have sufficient ozone to react with common indoor pollutants as well as skin oils and other common indoor air chemicals or surfaces. Particular concern is warranted when using "green" cleaning products based on citrus or terpene extracts, because these chemicals react very quickly with ozone to form toxic and irritating chemicals as well as
fine
Fine may refer to:
Characters
* Sylvia Fine (''The Nanny''), Fran's mother on ''The Nanny''
* Officer Fine, a character in ''Tales from the Crypt'', played by Vincent Spano
Legal terms
* Fine (penalty), money to be paid as punishment for an offe ...
and
ultrafine particles
Ultrafine particles (UFPs) are particulate matter of nanoscale size (less than 0.1 μm or 100 nm in diameter).
Regulations do not exist for this size class of ambient air pollution particles, which are far smaller than the regulated PM10 and PM ...
. Ventilation with outdoor air containing elevated ozone concentrations may complicate remediation attempts.
The
Clean Air Act of 1990 required the
United States Environmental Protection Agency
The Environmental Protection Agency (EPA) is an independent executive agency of the United States federal government tasked with environmental protection matters. President Richard Nixon proposed the establishment of EPA on July 9, 1970; it be ...
to set
National Ambient Air Quality Standards
The U.S. National Ambient Air Quality Standards (NAAQS, pronounced ) are limits on atmospheric concentration of six pollutants that cause smog, acid rain, and other health hazards. Established by the United States Environmental Protection Agency ...
(NAAQS) for six criteria air pollutants harmful to human health. Ozone is one of the criteria air pollutants. Other organizations have put forth air standards such as the
Occupational Safety and Health Administration
The Occupational Safety and Health Administration'' (OSHA ) is a large regulatory agency of the United States Department of Labor that originally had federal visitorial powers to inspect and examine workplaces. Congress established the agenc ...
(OSHA), the
National Institute for Occupational Safety and Health
The National Institute for Occupational Safety and Health (NIOSH, ) is the United States federal agency responsible for conducting research and making recommendations for the prevention of work-related injury and illness. NIOSH is part of the C ...
(NIOSH), and the
World Health Organization
The World Health Organization (WHO) is a specialized agency of the United Nations responsible for international public health. The WHO Constitution states its main objective as "the attainment by all peoples of the highest possible level of h ...
(WHO). The OSHA standard for Ozone concentration within the workplace is 0.1 ppm averaged over an 8-hour period. The EPA standard for ozone concentration is 0.07 ppm average over an 8-hour period.
Particulates
Atmospheric particulate matter, also known as
particulates
Particulates – also known as atmospheric aerosol particles, atmospheric particulate matter, particulate matter (PM) or suspended particulate matter (SPM) – are microscopic particles of solid or liquid matter suspended in the air. The ter ...
, can be found indoors and can
affect the health of occupants. Authorities have established standards for the maximum concentration of particulates to ensure indoor air quality.
Prompt cognitive deficits
In 2015, experimental studies reported the detection of significant episodic (situational) cognitive impairment from impurities in the air breathed by test subjects who were not informed about changes in the air quality. Researchers at the Harvard University and SUNY Upstate Medical University and Syracuse University measured the cognitive performance of 24 participants in three different controlled laboratory atmospheres that simulated those found in "conventional" and "green" buildings, as well as green buildings with enhanced ventilation. Performance was evaluated objectively using the widely used Strategic Management Simulation software simulation tool, which is a well-validated assessment test for executive decision-making in an unconstrained situation allowing initiative and improvisation. Significant deficits were observed in the performance scores achieved in increasing concentrations of either VOCs or
carbon dioxide
Carbon dioxide (chemical formula ) is a chemical compound made up of molecules that each have one carbon atom covalently double bonded to two oxygen atoms. It is found in the gas state at room temperature. In the air, carbon dioxide is transpar ...
, while keeping other factors constant. The highest impurity levels reached are not uncommon in some classroom or office environments.
Effect of indoor plants
Houseplant
A houseplant, sometimes known as a pot plant, potted plant, or an indoor plant, is an ornamental plant that is grown indoors. As such, they are found in places like residences and offices, mainly for decorative purposes. Common houseplants are us ...
s together with the medium in which they are grown can reduce components of indoor air pollution, particularly
volatile organic compound
Volatile organic compounds (VOCs) are organic compounds that have a high vapour pressure at room temperature. High vapor pressure correlates with a low boiling point, which relates to the number of the sample's molecules in the surrounding air, a ...
s (VOC) such as
benzene
Benzene is an organic chemical compound with the molecular formula C6H6. The benzene molecule is composed of six carbon atoms joined in a planar ring with one hydrogen atom attached to each. Because it contains only carbon and hydrogen atoms, ...
,
toluene
Toluene (), also known as toluol (), is a substituted aromatic hydrocarbon. It is a colorless, water-insoluble liquid with the smell associated with paint thinners. It is a mono-substituted benzene derivative, consisting of a methyl group (CH3) at ...
, and
xylene
In organic chemistry, xylene or xylol (; IUPAC name: dimethylbenzene) are any of three organic compounds with the formula . They are derived from the substitution of two hydrogen atoms with methyl groups in a benzene ring; which hydrogens are sub ...
. Plants remove CO
2 and release oxygen and water, although the quantitative impact for house plants is small. The interest in using potted plants for removing VOCs was sparked by a
1989 NASA study conducted in sealed chambers designed to replicate the environment on
space station
A space station is a spacecraft capable of supporting a human crew in orbit for an extended period of time, and is therefore a type of space habitat. It lacks major propulsion or landing systems. An orbital station or an orbital space station i ...
s. However, these results suffered from poor replication and are not applicable to typical buildings, where outdoor-to-indoor air exchange already removes VOCs at a rate that could only be matched by the placement of 10–1000 plants/m
2 of a building’s floor space.
Plants also appear to reduce airborne microbes and
mold
A mold () or mould () is one of the structures certain fungus, fungi can form. The dust-like, colored appearance of molds is due to the formation of Spore#Fungi, spores containing Secondary metabolite#Fungal secondary metabolites, fungal seco ...
s, and to increase
humidity
Humidity is the concentration of water vapor present in the air. Water vapor, the gaseous state of water, is generally invisible to the human eye. Humidity indicates the likelihood for precipitation, dew, or fog to be present.
Humidity depe ...
. However, the increased humidity can itself lead to increased levels of mold and even VOCs.
When carbon dioxide concentrations are elevated indoors relative to outdoor concentrations, it is only an indicator that ventilation is inadequate to remove metabolic products associated with human occupancy. Plants require carbon dioxide to grow and release oxygen when they consume carbon dioxide. A study published in the journal ''Environmental Science & Technology'' considered uptake rates of
ketones
In organic chemistry, a ketone is a functional group with the structure R–C(=O)–R', where R and R' can be a variety of carbon-containing substituents. Ketones contain a carbonyl group –C(=O)– (which contains a carbon-oxygen double bon ...
and
aldehydes
In organic chemistry, an aldehyde () is an organic compound containing a functional group with the structure . The functional group itself (without the "R" side chain) can be referred to as an aldehyde but can also be classified as a formyl grou ...
by the
peace lily
''Spathiphyllum'' is a genus of about 47 species of monocotyledonous flowering plants in the family Araceae, native to tropical regions of the Americas and southeastern Asia. Certain species of ''Spathiphyllum'' are commonly known as spath or pea ...
(''Spathiphyllum clevelandii'') and
golden pothos
''Epipremnum aureum'' is a species in the arum family (biology), family Araceae, native plant, native to Mo'orea in the Society Islands of French Polynesia. The species is a popular houseplant in temperateness, temperate regions but has also becom ...
(''Epipremnum aureum'') Akira Tani and C. Nicholas Hewitt found "Longer-term fumigation results revealed that the total uptake amounts were 30–100 times as much as the amounts dissolved in the leaf, suggesting that volatile organic carbons are metabolized in the leaf and/or translocated through the
petiole." It is worth noting the researchers sealed the plants in Teflon bags. "No VOC loss was detected from the bag when the plants were absent. However, when the plants were in the bag, the levels of aldehydes and ketones both decreased slowly but continuously, indicating removal by the plants." Studies done in sealed bags do not faithfully reproduce the conditions in the indoor environments of interest. Dynamic conditions with outdoor air ventilation and the processes related to the surfaces of the building itself and its contents as well as the occupants need to be studied.
Since extremely high humidity is associated with increased mold growth, allergic responses, and respiratory responses, the presence of additional moisture from houseplants may not be desirable in all indoor settings if watering is done inappropriately.
HVAC design
Environmentally
sustainable design
Environmentally sustainable design (also called environmentally conscious design, eco-design, etc.) is the philosophy of designing physical objects, the built environment, and services to comply with the principles of ecological sustainability ...
concepts also include aspects related to the commercial and residential heating, ventilation and air-conditioning (HVAC) industry. Among several considerations, one of the topics attended to is the issue of indoor air quality throughout the design and construction stages of a building's life.
One technique to reduce energy consumption while maintaining adequate air quality, is
demand-controlled ventilation. Instead of setting throughput at a fixed air replacement rate, carbon dioxide sensors are used to control the rate dynamically, based on the emissions of actual building occupants.
For the past several years, there have been many debates among indoor air quality specialists about the proper definition of indoor air quality and specifically what constitutes "acceptable" indoor air quality.
One way of quantitatively ensuring the health of indoor air is by the frequency of effective turnover of interior air by replacement with outside air. In the UK, for example, classrooms are required to have 2.5 outdoor
air changes per hour
Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air c ...
. In halls, gym, dining, and physiotherapy spaces, the
ventilation
Ventilation may refer to:
* Ventilation (physiology), the movement of air between the environment and the lungs via inhalation and exhalation
** Mechanical ventilation, in medicine, using artificial methods to assist breathing
*** Ventilator, a m ...
should be sufficient to limit
carbon dioxide
Carbon dioxide (chemical formula ) is a chemical compound made up of molecules that each have one carbon atom covalently double bonded to two oxygen atoms. It is found in the gas state at room temperature. In the air, carbon dioxide is transpar ...
to 1,500 ppm. In the US, and according to ASHRAE Standards, ventilation in classrooms is based on the amount of outdoor air per occupant plus the amount of outdoor air per unit of floor area, not air changes per hour. Since carbon dioxide indoors comes from occupants and outdoor air, the adequacy of ventilation per occupant is indicated by the concentration indoors minus the concentration outdoors. The value of 615 ppm above the outdoor concentration indicates approximately 15 cubic feet per minute of outdoor air per adult occupant doing sedentary office work where outdoor air contains 385 ppm, the current global average atmospheric CO
2 concentration. In classrooms, the requirements in the ASHRAE standard 62.1, Ventilation for Acceptable Indoor Air Quality, would typically result in about 3 air changes per hour, depending on the occupant density. Of course the occupants are not the only source of pollutants, so outdoor air ventilation may need to be higher when unusual or strong sources of pollution exist indoors. When outdoor air is polluted, then bringing in more outdoor air can actually worsen the overall quality of the indoor air and exacerbate some occupant symptoms related to outdoor air pollution. Generally, outdoor country air is better than indoor city air. Exhaust gas leakages can occur from furnace metal exhaust pipes that lead to the chimney when there are leaks in the pipe and the pipe gas flow area diameter has been reduced.
The use of
air filter
A particulate air filter is a device composed of fibrous, or porous materials which removes solid particulates such as dust, pollen, mold, and bacteria from the air. Filters containing an adsorbent or catalyst such as charcoal (carbon) may als ...
s can trap some of the air pollutants. The Department of Energy's Energy Efficiency and Renewable Energy section suggests that "
irFiltration should have a
Minimum Efficiency Reporting Value
Minimum Efficiency Reporting Value, commonly known as MERV, is a measurement scale designed in 1987 by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) to report the effectiveness of air filters in more detail ...
(MERV) of 13 as determined by ASHRAE 52.2-1999." Air filters are used to reduce the amount of dust that reaches the wet coils. Dust can serve as food to grow molds on the wet coils and ducts and can reduce the efficiency of the coils.
Moisture management and humidity control requires operating HVAC systems as designed. Moisture management and humidity control may conflict with efforts to try to optimize the operation to conserve energy. For example, moisture management and humidity control requires systems to be set to supply make-up air at lower temperatures (design levels), instead of the higher temperatures sometimes used to conserve energy in cooling-dominated climate conditions. However, for most of the US and many parts of Europe and Japan, during the majority of hours of the year, outdoor air temperatures are cool enough that the air does not need further cooling to provide thermal comfort indoors. However, high humidity outdoors creates the need for careful attention to humidity levels indoors. High humidities give rise to mold growth and moisture indoors is associated with a higher prevalence of occupant respiratory problems.
The "dew point temperature" is an absolute measure of the moisture in air. Some facilities are being designed with the design dew points in the lower 50s °F, and some in the upper and lower 40s °F. Some facilities are being designed using desiccant wheels with gas-fired heaters to dry out the wheel enough to get the required dew points. On those systems, after the moisture is removed from the make-up air, a cooling coil is used to lower the temperature to the desired level.
Commercial buildings, and sometimes residential, are often kept under slightly positive air pressure relative to the outdoors to reduce
infiltration
Infiltration may refer to:
Science, medicine, and engineering
*Infiltration (hydrology), downward movement of water into soil
*Infiltration (HVAC), a heating, ventilation, and air conditioning term for air leakage into buildings
*Infiltration (me ...
. Limiting infiltration helps with moisture management and humidity control.
Dilution of indoor pollutants with outdoor air is effective to the extent that outdoor air is free of harmful pollutants. Ozone in outdoor air occurs indoors at reduced concentrations because ozone is highly reactive with many chemicals found indoors. The products of the reactions between ozone and many common indoor pollutants include organic compounds that may be more odorous, irritating, or toxic than those from which they are formed. These products of ozone chemistry include formaldehyde, higher molecular weight aldehydes, acidic aerosols, and fine and ultrafine particles, among others. The higher the outdoor ventilation rate, the higher the indoor ozone concentration and the more likely the reactions will occur, but even at low levels, the reactions will take place. This suggests that ozone should be removed from ventilation air, especially in areas where outdoor ozone levels are frequently high. Recent research has shown that mortality and morbidity increase in the general population during periods of higher outdoor ozone and that the threshold for this effect is around 20 parts per billion (ppb).
Building ecology
It is common to assume that buildings are simply inanimate physical entities, relatively stable over time. This implies that there is little interaction between the triad of the building, what is in it (occupants and contents), and what is around it (the larger environment). We commonly see the overwhelming majority of the mass of material in a building as relatively unchanged physical material over time. In fact, the true nature of buildings can be viewed as the result of a complex set of dynamic interactions among their physical, chemical, and biological dimensions. Buildings can be described and understood as complex systems. Research applying the approaches ecologists use to the understanding of ecosystems can help increase our understanding. “
Building ecology“ is proposed as the application of those approaches to the built environment considering the dynamic system of buildings, their occupants, and the larger environment.
Buildings constantly evolve as a result of the changes in the environment around them as well as the occupants, materials, and activities within them. The various surfaces and the air inside a building are constantly interacting, and this interaction results in changes in each. For example, we may see a window as changing slightly over time as it becomes dirty, then is
cleaned, accumulates
dirt
Dirt is an unclean matter, especially when in contact with a person's clothes, skin, or possessions. In such cases, they are said to become dirty.
Common types of dirt include:
* Debris: scattered pieces of waste or remains
* Dust: a genera ...
again, is cleaned again, and so on through its life. In fact, the “dirt” we see may be evolving as a result of the interactions among the moisture, chemicals, and biological materials found there.
Buildings are designed or intended to respond actively to some of these changes in and around them with
heating, cooling, ventilating, air cleaning or illuminating systems. We clean, sanitize, and maintain surfaces to enhance their appearance, performance, or longevity. In other cases, such changes alter buildings in ways that may be important to their own integrity or their impact on building occupants through the evolution of the physical, chemical, and biological processes that define them at any time. We may find it useful to combine the tools of the physical sciences with those of the biological sciences and, especially, some of the approaches used for
ecosystem
An ecosystem (or ecological system) consists of all the organisms and the physical environment with which they interact. These biotic and abiotic components are linked together through nutrient cycles and energy flows. Energy enters the syste ...
s, in order to gain an enhanced understanding of the environments in which we spend the majority of our time, our buildings.
Institutional programs
The topic of IAQ has become popular due to the greater awareness of health problems caused by mold and triggers to
asthma
Asthma is a long-term inflammatory disease of the airways of the lungs. It is characterized by variable and recurring symptoms, reversible airflow obstruction, and easily triggered bronchospasms. Symptoms include episodes of wheezing, cou ...
and
allergies
Allergies, also known as allergic diseases, refer a number of conditions caused by the hypersensitivity of the immune system to typically harmless substances in the environment. These diseases include hay fever, food allergies, atopic derma ...
. In the US, awareness has also been increased by the involvement of the
United States Environmental Protection Agency
The Environmental Protection Agency (EPA) is an independent executive agency of the United States federal government tasked with environmental protection matters. President Richard Nixon proposed the establishment of EPA on July 9, 1970; it be ...
(EPA), which has developed an "IAQ Tools for Schools" program to help improve the indoor environmental conditions in educational institutions. The
National Institute for Occupational Safety and Health
The National Institute for Occupational Safety and Health (NIOSH, ) is the United States federal agency responsible for conducting research and making recommendations for the prevention of work-related injury and illness. NIOSH is part of the C ...
conducts Health Hazard Evaluations (HHEs) in workplaces at the request of employees, authorized representative of employees, or employers, to determine whether any substance normally found in the place of employment has potentially toxic effects, including indoor air quality.
A variety of scientists work in the field of indoor air quality, including chemists, physicists, mechanical engineers, biologists, bacteriologists, and computer scientists. Some of these professionals are certified by organisations such as the American Industrial Hygiene Association, the American Indoor Air Quality Council and the Indoor Environmental Air Quality Council.
On the international level, the
International Society of Indoor Air Quality and Climate
The International Society of Indoor Air Quality and Climate (ISIAQ) is a non-profit scientific organization seeking to advance and support the creation of healthy and comfortable indoor building environments. In 1992, the institution of ISIAQ was ...
(ISIAQ), formed in 1991, organises two major conferences, the Indoor Air and the Healthy Buildings series.
See also
*
Environmental management
*
Household air pollution
Household air pollution (HAP) is a significant form of indoor air pollution mostly relating to cooking and heating methods used in developing countries. Since much of the cooking is carried out with biomass fuel, in the form of wood, charcoal, ...
*
Indoor bioaerosol Indoor bioaerosol is bioaerosol in an indoor environment. Bioaerosols are natural or artificial particles of biological ( microbial, plant, or animal) origin suspended in the air. These particles are also referred to as organic dust. Bioaerosols ma ...
*
Microbiomes of the built environment
Microbiomes of the built environment is a field of inquiry into the communities of microorganisms that live in human constructed environments like houses, cars and water pipes. It is also sometimes referred to as ''microbiology of the built envi ...
*
Olfactory fatigue
Olfactory fatigue, also known as odor fatigue, olfactory adaptation, and noseblindness, is the temporary, normal inability to distinguish a particular odor after a prolonged exposure to that airborne compound. For example, when entering a restaur ...
*
Phase I environmental site assessment
References
Sources
; Monographs
*
*
*
*
*
*
*
; Articles, radio segments, web pages
* Apte, MG, et al.
Outdoor ozone and building related symptoms in the BASE study ''Indoor Air,'' 2008 Apr;18(2):156–70, cited by:
National Center for Biotechnology Information
The National Center for Biotechnology Information (NCBI) is part of the United States National Library of Medicine (NLM), a branch of the National Institutes of Health (NIH). It is approved and funded by the government of the United States. The ...
, nih.gov.
Bad In-Flight Air Exacerbated by Passengers Talk of the Nation,
National Public Radio
National Public Radio (NPR, stylized in all lowercase) is an American privately and state funded nonprofit media organization headquartered in Washington, D.C., with its NPR West headquarters in Culver City, California. It differs from other n ...
, September 21, 2007.
Indoor Air Pollution index page United States Environmental Protection Agency
The Environmental Protection Agency (EPA) is an independent executive agency of the United States federal government tasked with environmental protection matters. President Richard Nixon proposed the establishment of EPA on July 9, 1970; it be ...
.
*
External links
US Environmental Protection Agency info on IAQ
{{DEFAULTSORT:Indoor Air Quality
Air pollution
Building biology
Industrial hygiene
Heating, ventilation, and air conditioning
Occupational safety and health
Pollution