HOME
*





Smoke Exhaust Ductwork
Smoke exhaust ductwork, in Europe, is typically protected via passive fire protection means, subject to fire testing (typically tNBN EN 1366-8 and listing and approval use and compliance. It is used to remove smoke from buildings, ships or offshore structures to enable emergency evacuation as well as improved firefighting. In North America, fireproofed ductwork may be used for the purpose of smoke exhaust, but it is more common to use unfireproofed return air ductwork, whereby no fire testing or listings are employed to qualify the ductwork for this use. Means of construction Smoke exhaust can be built using: *ordinary sheet metal with external fireproofing treatment; or *a proprietary duct that is inherently fire-resistant; or *Fire resistant materials, such as calcium silicate. Gallery Image:GEOFLAM_1.jpg Image:GEOFLAM_2.jpg Image:GEOFLAM4.jpg Image:GEOFLAM5.JPG See also *Passive fire protection *Pressurisation ductwork *Heat and smoke vent * Grease duct * Calcium sil ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Mississippi Mills Nrc Irc National Fire Laboratory Smoke Exhaust Duct
Mississippi () is a state in the Southeastern region of the United States, bordered to the north by Tennessee; to the east by Alabama; to the south by the Gulf of Mexico; to the southwest by Louisiana; and to the northwest by Arkansas. Mississippi's western boundary is largely defined by the Mississippi River. Mississippi is the 32nd largest and 35th-most populous of the 50 U.S. states and has the lowest per-capita income in the United States. Jackson is both the state's capital and largest city. Greater Jackson is the state's most populous metropolitan area, with a population of 591,978 in 2020. On December 10, 1817, Mississippi became the 20th state admitted to the Union. By 1860, Mississippi was the nation's top cotton-producing state and slaves accounted for 55% of the state population. Mississippi declared its secession from the Union on January 9, 1861, and was one of the seven original Confederate States, which constituted the largest slaveholding states in the nati ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Passive Fire Protection
Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. Examples of passive systems include floor-ceilings and roofs, fire doors, windows, and wall assemblies, fire-resistant coatings, and other fire and smoke control assemblies. Passive fire protection systems can include active components such as fire dampers. Main characteristics Passive fire protection systems are intended to: * Contain a fire to the compartment of fire origin * Slow a fire from spreading from the compartment of fire origin * Slow the heating of structural members * Prevent the spread of fire through intentional openings (e.g., doors, HVAC ducts) in fire rated assemblies by the use of a fire rated closure (e.g., fire door, fire damper) * Prevent the spread of fire through penetrations (e.g., holes in fire walls through which building systems such as plumb ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Fire
Fire is the rapid oxidation of a material (the fuel) in the exothermic chemical process of combustion, releasing heat, light, and various reaction products. At a certain point in the combustion reaction, called the ignition point, flames are produced. The '' flame'' is the visible portion of the fire. Flames consist primarily of carbon dioxide, water vapor, oxygen and nitrogen. If hot enough, the gases may become ionized to produce plasma. Depending on the substances alight, and any impurities outside, the color of the flame and the fire's intensity will be different. Fire in its most common form can result in conflagration, which has the potential to cause physical damage through burning. Fire is an important process that affects ecological systems around the globe. The positive effects of fire include stimulating growth and maintaining various ecological systems. Its negative effects include hazard to life and property, atmospheric pollution, and water contamination. ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Smoke
Smoke is a suspension of airborne particulates and gases emitted when a material undergoes combustion or pyrolysis, together with the quantity of air that is entrained or otherwise mixed into the mass. It is commonly an unwanted by-product of fires (including stoves, candles, internal combustion engines, oil lamps, and fireplaces), but may also be used for pest control ( fumigation), communication (smoke signals), defensive and offensive capabilities in the military ( smoke screen), cooking, or smoking (tobacco, cannabis, etc.). It is used in rituals where incense, sage, or resin is burned to produce a smell for spiritual or magical purposes. It can also be a flavoring agent and preservative. Smoke inhalation is the primary cause of death in victims of indoor fires. The smoke kills by a combination of thermal damage, poisoning and pulmonary irritation caused by carbon monoxide, hydrogen cyanide and other combustion products. Smoke is an aerosol (or mist) of solid ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Listing And Approval Use And Compliance
Listing and approval use and compliance is the practice of installing and operating safety-related products and materials in accordance with to minimum performance conformance testing requirements. The conformance could be for a certification listing or for an approval that has been issued by an organization that is accredited both for testing and product certification. Such organizations include Underwriters Laboratories, FM Global, or the Deutsches Institut für Bautechnik (DIBt). Required listings or tests is often cited by a regulation such as a building code or a fire code and is enforced through adopted codes or regulations. In the absence of a standard test method, local building officials can review and approve results from qualified testing agencies on an ad-hoc basis if the evidence shows compliance for a material, product or construction method that provides equivalent strength, quality, fire resistance, durability and safety as compared to the building code objectives. ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

HVAC
Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. " Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR (as in the designation of HACR-rated circuit breakers). HVAC is an important part of residential structures such as single family homes, apartment buildings, hotels, and senior living facilities; medium to large industrial and office buildings such as skyscrapers and hospitals; vehicles such as cars, trains, airplanes, ships and submarines; and in marine environments, where safe and healthy building conditions are regulated with respect to temperature and humidity, using fres ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Firestop
A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke. Description Firestops prevent unprotected horizontal and vertical penetrations in a fire-resistance-rated wall or floor assembly from creating a route by which fire and smoke can spread that would otherwise have been fire resisting construction, e.g. where a pipe passes through a firewall. Fire stopping is also to seal around gaps between fire resisting constructions, e.g. the linear gap between a wall and the floor above, in order for construction to form a complete barrier to fire and smoke spread. Opening types Firestops are used in: * Electrical, mechanical, and structural penetrations * Unpenetrated openings (such as openings for future use) * Re-entries of exi ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Fireproofing
Fireproofing is rendering something (structures, materials, etc.) resistant to fire, or incombustible; or material for use in making anything fire-proof. It is a passive fire protection measure. "Fireproof" or "fireproofing" can be used as a noun, verb or adjective; it may be hyphenated ("fire-proof"). Applying a certification listed fireproofing system to certain structures allows them to have a fire-resistance rating. The term "fireproofing" may be used in conjunction with standards, as reflected in common North American construction specifications. An item classed as fireproof is resistant in specified circumstances, and may burn or be rendered inoperable by fire exceeding the intensity or duration that it is designed to withstand. Markets * Commercial construction * Residential construction * Industrial construction * Marine (ships) * Offshore construction * Aerodynamics * Tunnel concrete walls and ceilings or linings * Under- and above-ground mining operations Applica ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Calcium Silicate
Calcium silicate is the chemical compound Ca2SiO4, also known as calcium orthosilicate and is sometimes formulated as 2CaO·SiO2. It is also referred to by the shortened trade name Cal-Sil or Calsil. It occurs naturally as the mineral larnite. Properties Calcium silicate is a white free-flowing powder. It can be derived from naturally occurring limestone and diatomaceous earth, a siliceous sedimentary rock. It is one of a group of compounds that can be produced by reacting calcium oxide and silica in various ratios e.g. 3CaO·SiO2, alite (Ca3SiO5); 2CaO·SiO2, (Ca2SiO4); 3CaO·2SiO2, (Ca3SiO7); and CaO·SiO2, wollastonite (CaSiO3). It has a low bulk density and high physical water absorption. Use Calcium silicate is used as an anticaking agent in food preparation, including table salt
and as an

Grease Duct
A grease duct is a duct that vents grease-laden flammable vapors from commercial cooking equipment such as stoves, deep fryers, and woks to the outside of a building or mobile food preparation trailer. Grease ducts are part of the building's passive fire protection system. The cleaning schedule is typically dictated by fire code or related safety regulations. Fire hazard Vapors are created when grease is heated to and beyond its vaporization point. As the vapors cool, the grease condenses and settles on colder surfaces. Grease is a flammable hydrocarbon. A fire-resistance rating is required for the construction around the duct. Design In North America, grease ducts must be in compliance with NFPA 96 as well as the local building codes and fire codes. A proprietary duct system that has its own inherent fire-resistance rating can be used, such as a metallic duct, either field fabricated or UL certified factory-built designs. Factory-built fire rated designs are tested to UL 1 ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  




Heat And Smoke Vent
Heat and smoke vents are installed in buildings as an active fire protection measure. They are openings in the roof which are intended to vent the heat and smoke developed by a fire inside the building by the action of buoyancy, such that they are known as "gravity vents". Regulatory requirements Heat and smoke vents are typically installed in buildings for the following reasons: * Storage occupancies - The heat release rate from high piled storage commodities is expected to be very high. In such cases, it is considered by some fire protection professionals desirable to vent the heat from the building if the temperatures in the building reaches sufficiently high levels to endanger the structural stability of the roof system. Smoke venting is also considered to provide a minor benefit to increase the visibility in the interior space to facilitate manual fire fighting efforts for a limited period of time. The use of vents in sprinklered buildings has been controversial over the last ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Pressurisation Ductwork
Pressurisation duct work is a passive fire protection system. It is used to supply fresh air to any area of refuge, designated emergency evacuation or egress route. Purpose The purpose of pressurisation ductwork is to maintain positive pressure in building spaces to prevent smoke from entering from other spaces in which a fire is occurring. It is typically used in exit stairways, corridors, and lobbies. Requirements Pressurisation ductwork is certified on the basis of fire testing such as ISO 6944. Systems There are two means of providing fire-resistance rated ductwork: *Inherently fire-resistant, or proprietary factory assembled ducts which are made of sheet metal shells filled with mixtures of rockwool, fiber and silicon dioxide *Sheet metal duct with exterior fireproofing materials such as blanket rockwool, ceramic fiber, or in-tumescent paint. See also * Heat and smoke vent * Fire protection * Smoke exhaust ductwork * Emergency evacuation Emergency evacuation is ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]