Ultimo Power Station
   HOME

TheInfoList



OR:

The Ultimo Power Station, or Ultimo Powerhouse, was an electricity generating plant located in the inner-city
Sydney Sydney is the capital city of the States and territories of Australia, state of New South Wales and the List of cities in Australia by population, most populous city in Australia. Located on Australia's east coast, the metropolis surrounds Syd ...
suburb of
Ultimo, New South Wales Ultimo is an inner-city suburb of Sydney, New South Wales, Australia. It is adjacent to the Sydney central business district in the Local government in Australia, local government area of the City of Sydney west of the Darling Harbour area, and ...
. Commissioned in 1899, it was the first major power station in Sydney and was originally built to supply power for the electric tram network. Prior to this, a small installation had existed at Regent Street, which was brought into use on 15 June 1882. Additionally, experimental electric tram operations powered by small generators had been in intermittent use in Sydney since 1890.


Generating plant

Ultimo Power Station boasted a mixture of equipment, initially consisting of American-made
steam engines A steam engine is a heat engine that performs Work (physics), mechanical work using steam as its working fluid. The steam engine uses the force produced by steam pressure to push a piston back and forth inside a Cylinder (locomotive), cyl ...
coupled to dynamoelectric machines (
direct current Direct current (DC) is one-directional electric current, flow of electric charge. An electrochemical cell is a prime example of DC power. Direct current may flow through a conductor (material), conductor such as a wire, but can also flow throug ...
generators). Later generating units were British-made turbo-alternators. Most of the
alternating current Alternating current (AC) is an electric current that periodically reverses direction and changes its magnitude continuously with time, in contrast to direct current (DC), which flows only in one direction. Alternating current is the form in w ...
(AC) equipment operated at 6,600
volts The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). Definition One volt is defined as the electric potential between two point ...
, 25
cycles per second The cycle per second is a once-common English name for the unit of frequency now known as the ''hertz'' (Hz). Cycles per second may be denoted by c.p.s., c/s, or, ambiguously, just "cycles" (Cyc., Cy., C, or c). The term comes from repetitive ph ...
.


Direct current plant – 600 V

The original generating plant at Ultimo consisted of four cross-compound, reciprocating steam engines supplied by E. P. Allis & Co. of
Milwaukee Milwaukee is the List of cities in Wisconsin, most populous city in the U.S. state of Wisconsin. Located on the western shore of Lake Michigan, it is the List of United States cities by population, 31st-most populous city in the United States ...
,
Wisconsin Wisconsin ( ) is a U.S. state, state in the Great Lakes region, Great Lakes region of the Upper Midwest of the United States. It borders Minnesota to the west, Iowa to the southwest, Illinois to the south, Lake Michigan to the east, Michig ...
, each rated at 1250
horsepower Horsepower (hp) is a unit of measurement of power, or the rate at which work is done, usually in reference to the output of engines or motors. There are many different standards and types of horsepower. Two common definitions used today are t ...
(hp) and running at 100
rpm Revolutions per minute (abbreviated rpm, RPM, rev/min, r/min, or r⋅min−1) is a unit of rotational speed (or rotational frequency) for rotating machines. One revolution per minute is equivalent to hertz. Standards ISO 80000-3:2019 def ...
. HP cylinder diameter was and LP cylinder diameter was . Steam pressure was . Each steam engine was coupled to a multi-pole, compound-wound
dynamo "Dynamo Electric Machine" (end view, partly section, ) A dynamo is an electrical generator that creates direct current using a commutator. Dynamos employed electromagnets for self-starting by using residual magnetic field left in the iron cores ...
supplied by the
General Electric General Electric Company (GE) was an American Multinational corporation, multinational Conglomerate (company), conglomerate founded in 1892, incorporated in the New York (state), state of New York and headquartered in Boston. Over the year ...
Company (GE) of
Schenectady Schenectady ( ) is a City (New York), city in Schenectady County, New York, United States, of which it is the county seat. As of the United States Census 2020, 2020 census, the city's population of 67,047 made it the state's ninth-most populo ...
,
New York New York most commonly refers to: * New York (state), a state in the northeastern United States * New York City, the most populous city in the United States, located in the state of New York New York may also refer to: Places United Kingdom * ...
. Each dynamo ( generator) was rated at at 550
volt The volt (symbol: V) is the unit of electric potential, Voltage#Galvani potential vs. electrochemical potential, electric potential difference (voltage), and electromotive force in the International System of Units, International System of Uni ...
s
direct current Direct current (DC) is one-directional electric current, flow of electric charge. An electrochemical cell is a prime example of DC power. Direct current may flow through a conductor (material), conductor such as a wire, but can also flow throug ...
(1545
ampere The ampere ( , ; symbol: A), often shortened to amp,SI supports only the use of symbols and deprecates the use of abbreviations for units. is the unit of electric current in the International System of Units (SI). One ampere is equal to 1 c ...
s) and could be overloaded by up to 50 percent to satisfy peak demand. To cater to the growing demand of the electrified tram network, the engines were frequently run at . Each
tram A tram (also known as a streetcar or trolley in Canada and the United States) is an urban rail transit in which Rolling stock, vehicles, whether individual railcars or multiple-unit trains, run on tramway tracks on urban public streets; some ...
had less than worth of motors, but the original installation did not allow for growth. It followed that expansion of the power station beyond the initial four units was planned from the beginning. Steam was initially supplied by 14 horizontal multi-tubular under-fired (Colonial) fire tube boilers by G. & C. Hoskins, Sydney. Each was rated at and operated at a pressure of . The boilers were hand fired and had natural draught to a single chimney at the end of the building. Only twelve boilers were needed to provide sufficient steam for full-capacity power generation, leaving two in reserve. The original generating units were removed in 1915 and 1916, but some of the boilers were retained (see below).The Story of Electrical Energy by Brian Maher


First alternators – 6600 V, 25 Hz

The George St tram line experienced serious voltage drop problems, especially at the Circular Quay end. To fix this situation, alternators were brought into use from 1902, starting with three 1500 kW/6.6 kV units supplied by GE. Each alternator was powered by an Allis Reynolds vertical cross compound condensing reciprocating steam engine rated at 2500 hp at 75 rpm. HP cylinder diameter was and the LP cylinder diameter was with a stroke. The 40-pole alternators generated three phase current at 25 Hz. Alterations to the boiler house at this stage saw six of the original boilers removed. Then eight Babcock & Wilcox long-drum, chain-grate boilers were added. Steam pressure was and superheaters gave a final temperature of . As more generators were installed an additional 24 new boilers from Babcock & Wilcox (UK), each rated at 450 hp at 160 lb/sq in were added. By 1904 a total of thirty two B&W boilers were then on site. Provision (foundations) was made for the addition of three more reciprocating steam engine-alternator sets, but this was abandoned in favour of turbo-alternators. Vertical engine nos 5, 7 and 9 were removed between 1912 and 1914 to allow the addition of turbo-alternators.


Turbo-alternators – 6600 V, 25 Hz

The first turbo-alternator was brought into use at Ultimo Power Station on 9 January 1905(No6)Supplied by C.A. Parsons & Company of
Newcastle-upon-Tyne Newcastle upon Tyne, or simply Newcastle ( , Received Pronunciation, RP: ), is a City status in the United Kingdom, cathedral city and metropolitan borough in Tyne and Wear, England. It is England's northernmost metropolitan borough, located o ...
, England. The
steam turbine A steam turbine or steam turbine engine is a machine or heat engine that extracts thermal energy from pressurized steam and uses it to do mechanical work utilising a rotating output shaft. Its modern manifestation was invented by Sir Charles Par ...
was rated at 3000 hp, ran at 1500 rpm and drove an 1875 kW alternator at 50 Hz. The steam was raised in 16 new Babcock & Wilcox (UK) boilers, installed in 1905, bringing the total number of boilers on site to 48. These boilers were placed on top of the 32 original boilers. Two additional turbo-alternators were brought into use in 1909. Supplied by C.A. Parsons & Company, each was rated at 5000 kW with an overload capacity of 7500 kW and generated three phase alternating current at 25 Hz. They were numbered 10 and 12. Twelve new Babcock & Wilcox (UK) superheated boilers were added in 1910, and another 8 were added in 1913. They were also placed on top of the original boilers. The remaining eight fire-tube boilers were removed in 1912/13 to make room for coal bunkers. In 1911 a 5 MW 25 Hz Willans Dick-Kerr turbo-alternator was installed with a similar 5 MW machine added in 1913. These machines replaced the vertical generators and were numbered 5 and 8. In 1912, a Dick, Kerr turbo-alternator rated at 7.5 MW 25 Hz, with an overload capacity of 10.5 MW was brought into use at Ultimo as unit No.7. This machine had originally been intended for installation at White Bay Power Station, and it was later transferred there in 1918. In 1914 another Dick Kerr 8.7 MW 25 Hz set was installed as No9. Two 2.3 MW Dick Kerr alternators(ex Pyrmont) were added in 1919 and numbered 1+2. When the DC section was finally closed down in 1920, the remaining horizontal engines were replaced with two more 2.4 MW Dick-Kerr 50 Hz turbo alternators and numbered 3 & 4. Also, five rotary converters were installed to supply the required DC power. In 1921 it was decided that Ultimo would only generate 25 Hz power. The four small 50 Hz turbo generators were removed, with the last set removed in 1928. The first turbo generator (No. 6) was removed in 1922.


High-pressure turbo-alternators

In 1929, work began to replace the 58 small boilers with six larger boilers operating at and rated at 90,000 pounds of steam per hour. Steam outlet temperature was . The new boilers were the first to burn pulverised coal in any power station in New South Wales. Flue gasses were directed up the two brick chimneys built in 1902. Accompanying the new boilers were two 20 MW AGE-BTH turbo-alternators. They were numbered 1 and 2. This work was completed in 1931. In 1941, two more Babcock + Wilcox High Head boilers rated at 90,000 pounds of steam per hour, operating at a pressure of and , were brought into use. They had a balanced draught system and were fitted with chain grate stokers, and their flue gasses were taken away by two new short steel stacks. This was followed in 1942 by the commissioning of a third BTH 20 MW turbo-alternator(No4). In 1948, the two 5000 kW Parsons turbo-alternators Nos 10 and 12 were removed. In 1949, their space was taken by a single 18.75 MW unit manufactured by
English Electric The English Electric Company Limited (EE) was a British industrial manufacturer formed after World War I by amalgamating five businesses which, during the war, made munitions, armaments and aeroplanes. It initially specialised in industrial el ...
(Australia), which had been alternator No.4 at White Bay Power Station since 1924. This 18.75 MW set became No.3 at Ultimo and went into production about 1951. This brought the total installed capacity of Ultimo to its maximum of 79.5 MW. In 1948/49 the boilers were modified to allow the burning of furnace oil owing to coal supply shortages. Control of Ultimo Power Station was transferred from the Department of Railways, New South Wales to the newly formed Electricity Commission of New South Wales on 1 January 1953.


The Sydney Railway and Tramway Power Grid

The Sydney railway and tramway power grid consisted of Ultimo and White Bay Power Stations, which were linked by a 6600 V transmission network and fed railway and tramway sub-feeder stations. Following the initial 600 V direct current (DC) installation, Ultimo Power Station supplied three phase alternating current (AC) at 6600 V, 25 cycles per second. Originally, this current was not stepped up for transmission.
Rotary converters A rotary converter is a type of electrical machine which acts as a mechanical rectifier, Power inverter, inverter or frequency converter. Rotary converters were used to convert alternating current (AC) to direct current (DC), or DC to AC power, ...
were used to convert the three phase AC to 600 V DC for the tram supply. The 1500 V DC heavy rail electrification commenced operation in 1926 and also initially used high capacity rotary converters. A 25–50 Hz frequency changer was installed at White Bay in 1939, allowing power generated at the two railway power stations to be fed into Sydney County Council's 50 Hz grid as required. The gradual elimination of electric trams from Sydney reduced the demand on the 25 Hz grid. In 1959, it was decided to abandon 25 Hz generation altogether.


Decommissioning

Following the closure of the Sydney tram network in 1961, Ultimo Power Station was decommissioned in 1963. The site was later repurposed as a wing of the
Powerhouse Museum The Powerhouse Museum, formerly known as the Museum of Applied Arts & Sciences (MAAS), is a collection of 4 museums in Sydney, owned by the Government of New South Wales. Powerhouse is a contemporary museum of applied arts and sciences, explori ...
.


Engineering heritage award

The power station received a Historic Engineering Marker from
Engineers Australia Engineers Australia (EA), known formally as the Institution of Engineers, Australia, is an Australian professional body and Non-profit organization, not-for-profit organisation whose purpose is to advance the science and practice of engineerin ...
as part of its Engineering Heritage Recognition Program.


References

{{coord missing, New South Wales Decommissioned power stations in New South Wales Buildings and structures in Sydney 1899 establishments in Australia Energy infrastructure completed in 1899 Tourist attractions in Sydney Coal-fired power stations in New South Wales Ultimo, New South Wales Recipients of Engineers Australia engineering heritage markers