Introduction
Scanning tunneling spectroscopy is an experimental technique which uses a scanning tunneling microscope (STM) to probe the local density of electronic states (LDOS) and the band gap of surfaces and materials on surfaces at theTunneling current
Since STS relies on tunneling phenomena and measurement of the tunneling current or itsExperimental methods
Acquiring standard STM topographs at many different tip-sample biases and comparing to experimental topographic information is perhaps the most straightforward spectroscopic method. The tip-sample bias can also be changed on a line-by-line basis during a single scan. This method creates two interleaved images at different biases. Since only the states between the Fermi levels of the sample and the tip contribute to , this method is a quick way to determine whether there are any interesting bias-dependent features on the surface. However, only limited information about the electronic structure can be extracted by this method, since the constant topographs depend on the tip and sample DOS's and the tunneling transmission probability, which depends on the tip-sample spacing, as described in equation (5).R. Wiesendanger, ''Scanning Probe Microscopy and Spectroscopy: Methods and Applications'', Cambridge, UK: Cambridge University Press, 1994. By using modulation techniques, a constant current topograph and the spatially resolved can be acquired simultaneously. A small, high frequency sinusoidal modulation voltage is superimposed on the D.C. tip-sample bias. The A.C. component of the tunneling current is recorded using a lock-in amplifier, and the component in-phase with the tip-sample bias modulation gives directly. The amplitude of the modulation Vm has to be kept smaller than the spacing of the characteristic spectral features. The broadening caused by the modulation amplitude is 2 eVm and it has to be added to the thermal broadening of 3.2 kBT. In practice, the modulation frequency is chosen slightly higher than the bandwidth of the STM feedback system. This choice prevents the feedback control from compensating for the modulation by changing the tip-sample spacing and minimizes the displacement current 90° out-of-phase with the applied bias modulation. Such effects arise from the capacitance between the tip and the sample, which grows as the modulation frequency increases. In order to obtain I-V curves simultaneously with a topograph, a sample-and-hold circuit is used in the feedback loop for the z piezo signal. The sample-and-hold circuit freezes the voltage applied to the z piezo, which freezes the tip-sample distance, at the desired location allowing I-V measurements without the feedback system responding.R. C. Barrett and S. Park, “Design Considerations for an STM System,” from ''Scanning Tunneling Microscopy'', Ed. by W. J. Kaiser and J. A. Stroscio, San Diego: Academic Press, Inc., 1993. The tip-sample bias is swept between the specified values, and the tunneling current is recorded. After the spectra acquisition, the tip-sample bias is returned to the scanning value, and the scan resumes. Using this method, the local electronic structure of semiconductors in the band gap can be probed. There are two ways to record I-V curves in the manner described above. In constant-spacing scanning tunneling spectroscopy (CS-STS), the tip stops scanning at the desired location to obtain an I-V curve. The tip-sample spacing is adjusted to reach the desired initial current, which may be different from the initial current setpoint, at a specified tip-sample bias. A sample-and-hold amplifier freezes the z piezo feedback signal, which holds the tip-sample spacing constant by preventing the feedback system from changing the bias applied to the z piezo. The tip-sample bias is swept through the specified values, and the tunneling current is recorded. Either numerical differentiation of I(V) or lock-in detection as described above for modulation techniques can be used to find . If lock-in detection is used, then an A.C. modulation voltage is applied to the D.C. tip-sample bias during the bias sweep and the A.C. component of the current in-phase with the modulation voltage is recorded. In variable-spacing scanning tunneling spectroscopy (VS-STS), the same steps occur as in CS-STS through turning off the feedback. As the tip-sample bias is swept through the specified values, the tip-sample spacing is decreased continuously as the magnitude of the bias is reduced. Generally, a minimum tip-sample spacing is specified to prevent the tip from crashing into the sample surface at the 0 V tip-sample bias. Lock-in detection and modulation techniques are used to find the conductivity, because the tunneling current is a function also of the varying tip-sample spacing. Numerical differentiation of I(V) with respect to V would include the contributions from the varying tip-sample spacing.R. M. Feenstra and J. A. Stroscio, “Methods of Tunneling Spectroscopy,” from ''Scanning Tunneling Microscopy'', Ed. by W. J. Kaiser and J. A. Stroscio, San Diego: Academic Press, Inc., 1993. Introduced by Mårtensson and Feenstra to allow conductivity measurements over several orders of magnitude, VS-STS is useful for conductivity measurements on systems with large band gaps. Such measurements are necessary to properly define the band edges and examine the gap for states. Current-imaging-tunneling spectroscopy (CITS) is an STS technique where an I-V curve is recorded at each pixel in the STM topograph. Either variable-spacing or constant-spacing spectroscopy may be used to record the I-V curves. The conductance, , can be obtained by numerical differentiation of I with respect to V or acquired using lock-in detection as described above. Because the topographic image and the tunneling spectroscopy data are obtained nearly simultaneously, there is nearly perfect registry of topographic and spectroscopic data. As a practical concern, the number of pixels in the scan or the scan area may be reduced to prevent piezo creep or thermal drift from moving the feature of study or the scan area during the duration of the scan. While most CITS data obtained on the times scale of several minutes, some experiments may require stability over longer periods of time. One approach to improving the experimental design is by applying feature-oriented scanning (FOS) methodology.Data interpretation
From the obtained I-V curves, the band gap of the sample at the location of the I-V measurement can be determined. By plotting the magnitude of I on a log scale versus the tip-sample bias, the band gap can clearly be determined. Although determination of the band gap is possible from a linear plot of the I-V curve, the log scale increases the sensitivity. Alternatively, a plot of the conductance, , versus the tip-sample bias, V, allows one to locate the band edges that determine the band gap. The structure in the , as a function of the tip-sample bias, is associated with the density of states of the surface when the tip-sample bias is less than the work functions of the tip and the sample. Usually, the WKB approximation for the tunneling current is used to interpret these measurements at low tip-sample bias relative to the tip and sample work functions. The derivative of equation (5), I in the WKB approximation, is where is the sample density of states, is the tip density of states, and T is the tunneling transmission probability. Although the tunneling transmission probability T is generally unknown, at a fixed location T increases smoothly and monotonically with the tip-sample bias in the WKB approximation. Hence, structure in the is usually assigned to features in the density of states in the first term of equation (7). Interpretation of as a function of position is more complicated. Spatial variations in T show up in measurements of as an inverted topographic background. When obtained in constant current mode, images of the spatial variation of contain a convolution of topographic and electronic structure. An additional complication arises since in the low-bias limit. Thus, diverges as V approaches 0, preventing investigation of the local electronic structure near the Fermi level. Since both the tunneling current, equation (5), and the conductance, equation (7), depend on the tip DOS and the tunneling transition probability, T, quantitative information about the sample DOS is very difficult to obtain. Additionally, the voltage dependence of T, which is usually unknown, can vary with position due to local fluctuations in the electronic structure of the surface. For some cases, normalizing by dividing by can minimize the effect of the voltage dependence of T and the influence of the tip-sample spacing. Using the WKB approximation, equations (5) and (7), we obtain:R. J. Hamers, “STM on Semiconductors,” from ''Scanning Tunneling Microscopy I'', Springer Series in Surface Sciences 20, Ed. by H. -J. Güntherodt and R. Wiesendanger, Berlin: Springer-Verlag, 1992. Feenstra et al. argued that the dependencies of and on tip-sample spacing and tip-sample bias tend to cancel, since they appear as ratios. This cancellation reduces the normalized conductance to the following form: where normalizes T to the DOS and describes the influence of the electric field in the tunneling gap on the decay length. Under the assumption that and vary slowly with tip-sample bias, the features in reflect the sample DOS,Limitations
While STS can provide spectroscopic information with amazing spatial resolution, there are some limitations. The STM and STS lack chemical sensitivity. Since the tip-sample bias range in tunneling experiments is limited to , where is the apparent barrier height, STM and STS only sample valence electron states. Element-specific information is generally impossible to extract from STM and STS experiments, since the chemical bond formation greatly perturbs the valence states. At finite temperatures, the thermal broadening of the electron energy distribution due to the Fermi-distribution limits spectroscopic resolution. At , , and the sample and tip energy distribution spread are both . Hence, the total energy deviation is . Assuming the dispersion relation for simple metals, it follows from the uncertainty relation that where is the Fermi energy, is the bottom of the valence band, is the Fermi wave vector, and is the lateral resolution. Since spatial resolution depends on the tip-sample spacing, smaller tip-sample spacings and higher topographic resolution blur the features in tunneling spectra. Despite these limitations, STS and STM provide the possibility for probing the local electronic structure of metals, semiconductors, and thin insulators on a scale unobtainable with other spectroscopic methods. Additionally, topographic and spectroscopic data can be recorded simultaneously.References
Further reading
* * * * * * {{Branches of Spectroscopy Scanning probe microscopy Spectroscopy