A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke. Description Firestops prevent unprotected horizontal and vertical penetrations in a fire-resistance-rated wall or floor assembly from creating a route by which fire and smoke can spread that would otherwise have been fire resisting construction, e.g. where a pipe passes through a firewall. Fire stopping is also to seal around gaps between fire resisting constructions, e.g. the linear gap between a wall and the floor above, in order for construction to form a complete barrier to fire and smoke spread. Opening types Firestops are used in: * Electrical, mechanical, and structural penetrations * Unpenetrated openings (such as openings for future use) * Re-entries of exi ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Passive Fire Protection
Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. Examples of passive systems include floor-ceilings and roofs, fire doors, windows, and wall assemblies, fire-resistant coatings, and other fire and smoke control assemblies. Passive fire protection systems can include active components such as fire dampers. Main characteristics Passive fire protection systems are intended to: * Contain a fire to the compartment of fire origin * Slow a fire from spreading from the compartment of fire origin * Slow the heating of structural members * Prevent the spread of fire through intentional openings (e.g., doors, HVAC ducts) in fire rated assemblies by the use of a fire rated closure (e.g., fire door, fire damper) * Prevent the spread of fire through penetrations (e.g., holes in fire walls through which building systems such as plu ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Penetration (firestop)
A penetration, in firestopping, is an ''opening'', such as one created by the use of a cast-in-place sleeve, in a wall or floor assembly required to have a fire-resistance rating, for the purpose of accommodating the passage of a mechanical, electrical or structural penetrant. The penetration may or may not contain a firestop system. A ''penetration'' is not a ''penetrant''. A penetration may or may not include a penetrant. Images Image:Cans_form_penetrations.jpg, Sheet metal cans are nailed to form boards where concrete is about to be cast. The cans are located by the plumber. Once the penetrants are in place, one can firestop. Image:Sprinkler branch penetration.jpg, A penetration, in this case without a firestop. Image:Mortar tag.jpg, A firestopped penetration See also * Sleeve (construction) * Passive fire protection * Annulus (firestop) * Joint (building) * Penetrant (mechanical, electrical, or structural) * Mortar (firestop) * Firestop pillow * Fire test {{div ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Firestop Pillow
Firestop pillows are passive fire protection items used for firestopping holes to achieve fireproofing. The various kinds of firestop pillows are intended to slow the spread of fire. They are often used to meet fire-resistance ratings in conduits that need frequent access. Description and use Firestop pillows are used for firestopping holes in wall or floor assemblies, particularly in openings that require frequent access (e.g., cable changes), requiring the removal of the firestopping and resealing after the changes are completed. The products are required to have fire-resistance ratings and to be used in accordance with a certification listing A certification listing is a document used to guide installations of certified products, against which a field installation is compared to make sure that it complies with a regulation (e.g., a building code). Typically, products or items are req .... Pillow types There are three types of firestop pillows: * rockwool batts w ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Joint (building)
A building joint is a junction where building elements meet without applying a static load from one element to another. When one or more of these vertical or horizontal elements that meet are required by the local building code to have a fire-resistance rating, the resulting opening that makes up the joint must be firestopped in order to restore the required compartmentalisation. Qualification requirements Such joints are often subject to movement. Firestops must be able to demonstrate the ability to withstand operational movement prior to fire testing. Firestops for such building joints can be qualified tUL 2079 -- Tests for Fire Resistance of Building Joint Systems The joint design must consider the anticipated operational movement of each joint. Timing is also important, as freshly poured concrete shrinks particularly during the first few months of a new building, potentially causing joint size changes. Head-of-Wall (HOW) Where vertical fire-resistance rated wall asse ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Silicone
A silicone or polysiloxane is a polymer made up of siloxane (−R2Si−O−SiR2−, where R = organic group). They are typically colorless oils or rubber-like substances. Silicones are used in sealants, adhesives, lubricants, medicine, cooking utensils, thermal insulation, and electrical insulation. Some common forms include silicone oil, silicone grease, silicone rubber, silicone resin, and silicone caulk. Chemistry More precisely called polymerized siloxanes or polysiloxanes, silicones consist of an inorganic silicon–oxygen backbone chain (⋯−Si−O−Si−O−Si−O−⋯) with two organic groups attached to each silicon center. Commonly, the organic groups are methyl. The materials can be cyclic or polymeric. By varying the −Si−O− chain lengths, side groups, and crosslinking, silicones can be synthesized with a wide variety of properties and compositions. They can vary in consistency from liquid to gel to rubber to hard plastic. The most common si ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Fire-resistance Rating
A fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may entail other criteria, involving evidence of functionality or fitness for purpose. Common rating systems The following depict the most commonly used international time/temperature curves: File:Din iso astm ul curves.JPG, Time/Temperature Curves used for testing the fire-resistance rating of passive fire protection system A system is a group of interacting or interrelated elements that act according to a set of rules to form a unified whole. A system, surrounded and influenced by its environment, is described by its boundaries, structure and purpose and express ...s such as firestops, fire doors, wall and floor assemblies, etc., which are used in Compartmentalization (fire protection), compartmentalisation in buildings and the petrochemical industry in Europe and North Am ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Fire-resistance Rating
A fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may entail other criteria, involving evidence of functionality or fitness for purpose. Common rating systems The following depict the most commonly used international time/temperature curves: File:Din iso astm ul curves.JPG, Time/Temperature Curves used for testing the fire-resistance rating of passive fire protection system A system is a group of interacting or interrelated elements that act according to a set of rules to form a unified whole. A system, surrounded and influenced by its environment, is described by its boundaries, structure and purpose and express ...s such as firestops, fire doors, wall and floor assemblies, etc., which are used in Compartmentalization (fire protection), compartmentalisation in buildings and the petrochemical industry in Europe and North Am ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Cable Tray
In the electrical wiring of buildings, a cable tray system is used to support insulated electrical cables used for power distribution, control, and communication. Cable trays are used as an alternative to open wiring or electrical conduit systems, and are commonly used for cable management in commercial and industrial construction. They are especially useful in situations where changes to a wiring system are anticipated, since new cables can be installed by laying them in the tray, instead of pulling them through a pipe. According to the National Electrical Code standard of the United States, a cable tray is a unit or assembly of units or sections and associated fittings forming a rigid structural system used to securely fasten or support cables and raceways. Types Several types of tray are used in different applications. A solid-bottom tray provides the maximum protection to cables, but requires cutting the tray or using fittings to enter or exit cables. A deep, solid enclos ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  




Intumescent
An intumescent is a substance that swells as a result of heat exposure, leading to an increase in volume and decrease in density. Intumescent materials are typically used in passive fire protection and require listing, approval, and compliance in their installed configurations in order to comply with the national building codes and laws. The details for individual building parts are specified in technical standards which are compiled and published by national or international standardization bodies like the British Standards Institute (BSI), the German Institute for Standardization (DIN), the American Society for Testing and Materials (ASTM) or the International Standardization Organization (ISO). Intumescent coatings for steel constructions must be approved in standardized fire tests. Types Soft char These intumescent materials produce a light char which is a poor conductor of heat, thus retarding heat transfer. Typically the light char consist of microporous carbonaceous fo ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Fire Test
A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation. Successful tests in laboratories holding national accreditation for testing and certification result in the issuance of a certification listing. Components and systems subject to certification fire testing include fire rated walls and floors, closures within them such as windows, fire doors, fire dampers, structural steel, and fire stops. Fire tests are conducted both on active fire protection and on passive fire protection items. There are full-scale, small-scale and bench-scale tests. Fire testing considers all applicable provisions of the product certification. Examples of fire testing for products and systems * ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials, also known as the Steiner tunnel test * ASTM E1354 Standard Test Method for Heat and Visible Smoke Release ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Penetrant (mechanical, Electrical, Or Structural)
Penetrants, or penetrating items, are the mechanical, electrical or structural items that pass through an opening in a wall or floor, such as pipes, electrical conduits, ducting, electrical cables and cable trays, or structural steel beams and columns. When these items pierce a wall or floor assembly, they create a space between the penetrant and the surrounding structure which can become an avenue for the spread of fire between rooms or floors. Building codes require a firestop to seal the openings around penetrants. Image:Mcc room perimeter canned cable penseal metacaulk.jpg, Electrical cable through-penetration, firestopped by an intumescent sealant, to restore the two-hour fire-resistance rating of the concrete floor. image:Steel_beam_penetration.jpg, Steel Steel is an alloy made up of iron with added carbon to improve its strength and fracture resistance compared to other forms of iron. Many other elements may be present or added. Stainless steels that are co ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Mineral Wool
Mineral wool is any fibrous material formed by spinning or drawing molten mineral or rock materials such as slag and ceramics. Applications of mineral wool include thermal insulation (as both structural insulation and pipe insulation), filtration, soundproofing, and hydroponic growth medium. Naming Mineral wool is also known as ''mineral fiber'', ''mineral cotton'', ''mineral fibre'', ''man-made mineral fibre'' (MMMF), and ''man-made vitreous fiber'' (MMVF). Specific mineral wool products are ''stone wool'' and ''slag wool''. Europe also includes glass wool which, together with ceramic fiber, are entirely artificial fibers that can be made into different shapes and are spiky to touch. History Slag wool was first made in 1840 in Wales by Edward Parry, "but no effort appears to have been made to confine the wool after production; consequently it floated about the works with the slightest breeze, and became so injurious to the men that the process had to be abandoned". ...
[...More Info...]      