Voltage sensitive dye
   HOME

TheInfoList



OR:

Voltage-sensitive dyes, also known as potentiometric dyes, are dyes which change their
spectral ''Spectral'' is a 2016 3D military science fiction, supernatural horror fantasy and action-adventure thriller war film directed by Nic Mathieu. Written by himself, Ian Fried, and George Nolfi from a story by Fried and Mathieu. The film stars ...
properties in response to
voltage Voltage, also known as electric pressure, electric tension, or (electric) potential difference, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to ...
changes. They are able to provide linear measurements of firing activity of single neurons, large neuronal populations or activity of
myocytes A muscle cell is also known as a myocyte when referring to either a cardiac muscle cell (cardiomyocyte), or a smooth muscle cell as these are both small cells. A skeletal muscle cell is long and threadlike with many nuclei and is called a muscl ...
. Many physiological processes are accompanied by changes in cell membrane potential which can be detected with voltage sensitive dyes. Measurements may indicate the site of
action potential An action potential occurs when the membrane potential of a specific cell location rapidly rises and falls. This depolarization then causes adjacent locations to similarly depolarize. Action potentials occur in several types of animal cells, ...
origin, and measurements of action potential velocity and direction may be obtained. Potentiometric dyes are used to monitor the electrical activity inside cell organelles where it is not possible to insert an
electrode An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials d ...
, such as the mitochondria and
dendritic spine A dendritic spine (or spine) is a small membranous protrusion from a neuron's dendrite that typically receives input from a single axon at the synapse. Dendritic spines serve as a storage site for synaptic strength and help transmit electrical s ...
. This technology is especially powerful for the study of patterns of activity in complex multicellular preparations. It also makes possible the measurement of spatial and temporal variations in membrane potential along the surface of single cells.


Types of dyes

Fast-response probes: These are amphiphilic membrane staining dyes which usually have a pair of hydrocarbon chains acting as membrane anchors and a hydrophilic group which aligns the chromophore perpendicular to the membrane/aqueous interface. The chromophore is believed to undergo a large electronic charge shift as a result of excitation from the ground to the excited state and this underlies the putative electrochromic mechanism for the sensitivity of these dyes to membrane potential. This molecule (dye) intercalates among the
lipophilic Lipophilicity (from Greek λίπος "fat" and φίλος "friendly"), refers to the ability of a chemical compound to dissolve in fats, oils, lipids, and non-polar solvents such as hexane or toluene. Such non-polar solvents are themselves lipo ...
part of biological membranes. This orientation assures that the excitation induced charge redistribution will occur parallel to the electric field within the membrane. A change in the voltage across the membrane will therefore cause a spectral shift resulting from a direct interaction between the field and the ground and excited state dipole moments. New voltage dyes can sense voltage with high speed and sensitivity using photoinduced electron transfer (PeT) through a conjugated molecular wire. Slow-response probes: These exhibit potential-dependent changes in their transmembrane distribution which are accompanied by a fluorescence change. Typical slow-response probes include cationic carbocyanines and rhodamines, and ionic oxonols.


Examples

Commonly used voltage sensitive dyes are substituted aminonaphthylethenylpyridinium (ANEP) dyes, such as di-4-ANEPPS, di-8-ANEPPS, and RH237. Depending on their chemical modifications which change their physical properties they are used for different experimental procedures. They were first described in 1985 by the research group of Leslie Loew. ANNINE-6plus is a voltage sensitive dye with fast response (ns
response time Response time may refer to: *The time lag between an electronic input and the output signal which depends upon the value of passive components used. * Responsiveness, how quickly an interactive system responds to user input * Response time (biolog ...
) and high sensitivity. It has been applied to measure the action potentials of a single
t-tubule T-tubules (transverse tubules) are extensions of the cell membrane that penetrate into the center of skeletal and cardiac muscle cells. With membranes that contain large concentrations of ion channels, transporters, and pumps, T-tubules permi ...
of cardiomyocytes by Guixue Bu et al. More recently, a series of fluorinated ANEP dyes was introduced that offer enhanced sensitivity and photostability; they are also available over a wide choice of excitation and emission wavelengths. A recent computational study confirmed that the ANEP dyes are affected only by the electrostatic environment and not by specific molecular interactions. Other structural scaffolds, such as xanthenes, are also successfully used.


Materials

The core material for imaging brain activity with voltage-sensitive dyes are the dyes themselves. These voltage-sensitive dyes are
lipophilic Lipophilicity (from Greek λίπος "fat" and φίλος "friendly"), refers to the ability of a chemical compound to dissolve in fats, oils, lipids, and non-polar solvents such as hexane or toluene. Such non-polar solvents are themselves lipo ...
and preferably localized in membranes with their hydrophobic tails. They are used in applications involving fluorescence or absorption; they are fast acting and are able to provide linear measurements of changes in membrane potential. Voltage sensitive dyes are supplied by many companies who offer fluorescent probes for biological applications
Potentiometric Probes, LLC
specializes only in voltage sensitive dyes; they have an exclusive license to distribute the large set of fluorinated VSDs, marketed under the ElectroFluorTM brand. A variety of specialized equipment may be used in conjunction with the dyes, and choices in equipment will vary according to the particularities of a preparation. Essentially, equipment will include specialized microscopes and imaging devices, and may include technical lamps or lasers.


Strengths and weaknesses

Strengths of imaging brain activity with voltage-sensitive dyes include the following abilities: * Measurement of population signals from many areas may be taken simultaneously, and hundreds of neurons may be recorded from. Such multisite recordings may provide precise information on action potential initiation and propagation (including direction and velocity), and on the entire branching structure of a neuron. * Measurements of spike activity in a ganglion that is producing behaviour can be taken and may provide information about how the behaviour is producing. * In certain preparations the pharmacological effects of the dyes may be completely reversed by removing the staining pipette and allowing the neuron 1–2 hours for recovery. * Dyes may be used to analyze signal integration in terminal dendritic branches. Voltage-sensitive dyes offer the only alternative to genetically encoded voltage sensitive proteins (such as Ci-VSP derived proteins) for doing this. * More soluble dyes such as
ElectroFluor-530s
o
di-2-ANEPEQ
may perfused internally into single cell through a patch pipet. This technique has permitted the study of electrical signals in individual dendrites and dendritic spines within brain slices. Weaknesses of imaging brain activity with voltage-sensitive dyes include the following problems: * Voltage-sensitive dyes may respond very differently from one preparation to another; typically tens of dyes must be tested in order to obtain an optimal signal., imaging parameters, such as excitation wavelength, emission wavelength, exposure time, should also be optimized. * Voltage-sensitive dyes often fail to penetrate through connective tissue or move through intracellular spaces to the region of membrane desired for study. Staining is a serious issue in applications of these dyes. Water-soluble dyes, such as ANNINE-6plus
ElectroFluor-530s
o
di-2-ANEPEQ
do not suffer this problem. * On the other hand, if the dyes are too water-soluble, staining may not persist. This can be addressed by utilizing dyes containing longer alkyl chains to increase lipophilicity. * Noise is a problem in all preparations with voltage-sensitive dyes and in certain preparations the signal may be significantly obscured. Signal to noise ratios can be improved with
spatial filter A spatial filter is an optical device which uses the principles of Fourier optics to alter the structure of a beam of light or other electromagnetic radiation, typically coherent laser light. Spatial filtering is commonly used to "clean up" the o ...
ing or temporal filtering algorithms. Many such algorithms exist; one signal processing algorithm can be found in recent work with the ANNINE-6plus dye. * Cells may be permanently affected by treatments. Lasting pharmacological effects are possible, and the photodynamics of the dyes can be damaging. Recently developed fuorinated voltages sensitive dyes have been shown to mitigate these effects.


Uses

Voltage-sensitive dyes have been used to measure neural activity in several areas of the nervous system in a variety of organisms, including the
squid giant axon The squid giant axon is the very large (up to 1.5 mm in diameter; typically around 0.5 mm) axon that controls part of the water jet propulsion system in squid. It was first described by L. W. Williams in 1909, but this discovery was fo ...
, whisker barrels of the rat somatosensory cortex,
olfactory bulb The olfactory bulb (Latin: ''bulbus olfactorius'') is a neural structure of the vertebrate forebrain involved in olfaction, the sense of smell. It sends olfactory information to be further processed in the amygdala, the orbitofrontal cortex ( ...
of the salamander,
visual cortex The visual cortex of the brain is the area of the cerebral cortex that processes visual information. It is located in the occipital lobe. Sensory input originating from the eyes travels through the lateral geniculate nucleus in the thalamus and ...
of the cat,
optic tectum In neuroanatomy, the superior colliculus () is a structure lying on the roof of the mammalian midbrain. In non-mammalian vertebrates, the homologous structure is known as the optic tectum, or optic lobe. The adjective form '' tectal'' is commonl ...
of the frog, and the visual cortex of the rhesus monkey. Many applications in cardiac electrophysiology have been published, including ''ex vivo'' mapping of electrical activity in whole hearts from various animal species, subcellular imaging from single cardiomyocytes, and even mapping both sinus rhythms and arrhytmias in open heart ''in vivo'' pig, where motion artifacts could be eliminated by dual wavelength ratio imaging of the voltage sensitive dye fluorescence.


References


Further reading

* {{refend Biochemistry detection methods Cell culture reagents Neuroscience Electrophysiology Cell biology