Tomosynthesis
   HOME

TheInfoList



OR:

Tomosynthesis, also digital tomosynthesis (DTS), is a method for performing high-resolution limited-angle
tomography Tomography is imaging by sections or sectioning that uses any kind of penetrating wave. The method is used in radiology, archaeology, biology, atmospheric science, geophysics, oceanography, plasma physics, materials science, astrophysics, ...
at
radiation dose Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can travel ...
levels comparable with
projectional radiography Projectional radiography, also known as conventional radiography, is a form of radiography and medical imaging that produces two-dimensional images by x-ray radiation. The image acquisition is generally performed by radiographers, and the images a ...
. It has been studied for a variety of clinical applications, including vascular imaging, dental imaging, orthopedic imaging, mammographic imaging, musculoskeletal imaging, and chest imaging.


History

The concept of tomosynthesis was derived from the work of Ziedses des Plantes, who developed methods of reconstructing an arbitrary number of planes from a set of projections. Though this idea was displaced by the advent of computed tomography, tomosynthesis later gained interest as a low-dose tomographic alternative to CT.


Reconstruction

Tomosynthesis reconstruction algorithms are similar to CT reconstructions, in that they are based on performing an inverse
Radon transform In mathematics, the Radon transform is the integral transform which takes a function ''f'' defined on the plane to a function ''Rf'' defined on the (two-dimensional) space of lines in the plane, whose value at a particular line is equal to the ...
. Due to partial data sampling with very few projections, approximation algorithms have to be used. Filtered back projection and iterative, expectation-maximization algorithms have both been used to reconstruct the data. Reconstruction algorithms for tomosynthesis are different from those of conventional CT because the conventional
filtered back projection In mathematics, the Radon transform is the integral transform which takes a function ''f'' defined on the plane to a function ''Rf'' defined on the (two-dimensional) space of lines in the plane, whose value at a particular line is equal to the ...
algorithm requires a complete set of data. Iterative algorithms based upon expectation maximization are most commonly used, but are computationally intensive. Some manufacturers have produced practical systems using off-the-shelf GPUs to perform the reconstruction in a few seconds.


Differences from other imaging modalities

Digital tomosynthesis combines digital image capture and processing with simple tube/detector motion as used in conventional computed tomography (CT). However, though there are some similarities to CT, it is a separate technique. In modern (helical) CT, the source/detector makes at least a complete 180-degree rotation about the subject obtaining a complete set of data from which images may be reconstructed. Digital tomosynthesis, on the other hand, only uses a limited rotation angle (e.g., 15-60 degrees) with a lower number of discrete exposures (e.g., 7-51) than CT. This incomplete set of projections is digitally processed to yield images similar to conventional tomography with a limited
depth of field The depth of field (DOF) is the distance between the nearest and the furthest objects that are in acceptably sharp focus in an image captured with a camera. Factors affecting depth of field For cameras that can only focus on one object dis ...
. Because the image processing is digital, a series of slices at different depths and with different thicknesses can be reconstructed from the same acquisition. However, since fewer projections are needed than CT to perform the reconstruction, radiation exposure and cost are both reduced.


Applications


Breast

Digital breast tomosynthesis (DBT) is
Food and Drug Administration The United States Food and Drug Administration (FDA or US FDA) is a federal agency of the Department of Health and Human Services. The FDA is responsible for protecting and promoting public health through the control and supervision of food ...
(FDA) approved for use in
breast cancer screening Breast cancer screening is the medical screening of asymptomatic, apparently healthy women for breast cancer in an attempt to achieve an earlier diagnosis. The assumption is that early detection will improve outcomes. A number of screening tests ...
. The benefit for screening has been debated, but consensus is being reached that the technology is improving sensitivity compared to two-view digital
mammography Mammography (also called mastography) is the process of using low-energy X-rays (usually around 30 kVp) to examine the human breast for diagnosis and screening. The goal of mammography is the early detection of breast cancer, typically through ...
at the cost of a slightly reduced specificity (increased recall rates). Because the data acquired are 85 - 160 micron typical resolution, much higher than CT, DBT is unable to offer the narrow slice widths that CT offers (typically 1-1.5 mm). However, the higher resolution detectors permit very high in-plane resolution, even if the Z-axis resolution is less. Another interesting property of breast tomosynthesis is that image quality may vary substantially through the imaging volume. Photon-counting breast tomosynthesis has been investigated, and spectral imaging applications, such as
breast density Breast cancer screening is the medical screening of asymptomatic, apparently healthy women for breast cancer in an attempt to achieve an earlier diagnosis. The assumption is that early detection will improve outcomes. A number of screening tests ...
measurement and lesion characterization, have been investigated on that platform.


Chest


Musculoskeletal imaging

Tomosynthesis has a much more limited depth of field than does CT. For this reason, it likely will not be able to replace CT for the evaluation of the deeper organs of the body. However, since bones are often near the skin, multiple musculoskeletal applications of tomosynthesis have been studied, most of which have mostly been used in research with limited use in everyday practice.


Evaluation of fractures

Tomosynthesis has been compared to both radiography and CT for the evaluation of healing fractures, especially in the presence of hardware. In a study of patients with wrist fractures, digital tomosynthesis was shown to enable detection of more fractures than radiography while simultaneously providing lower metal artifact than radiography.


Evaluation of erosions in rheumatoid arthritis

Tomosynthesis has been compared to digital radiography, with CT as the standard, for the detection of erosions associated with
rheumatoid arthritis Rheumatoid arthritis (RA) is a long-term autoimmune disorder that primarily affects joints. It typically results in warm, swollen, and painful joints. Pain and stiffness often worsen following rest. Most commonly, the wrist and hands are inv ...
. The radiation dose of digital tomosynthesis was very close to that of digital radiography. However, tomosynthesis showed sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 80%, 75%, 78%, 76%, and 80%, compared to digital radiography were 66%, 81%, 74%, 77%, and 71%. The slight benefit digital tomosynthesis in this application may or may not justify the slightly increased cost of the modality compared to digital radiography.


Electronics

Tomosynthesis is also used for x-ray inspection of electronics, particularly printed circuit board assemblies and electronic components. Tomosynthesis is usually used where a CT slice is required at high magnification, where conventional CT would not allow the sample to be located close enough to the x-ray source.


References


External links


Digital Tomosynthesis: Advanced Breast Cancer Imaging Technique, by Max Wiedmann, UCSB
{{Breast procedures X-ray computed tomography Breast cancer