The train communication network (TCN) is a hierarchical combination of two
fieldbus Fieldbus is the name of a family of industrial computer networks used for real-time distributed control. Fieldbus profiles are standardized by the International Electrotechnical Commission (IEC) as IEC 61784/61158. A complex automated industrial ...
for data transmission within trains. It consists of the Multifunction Vehicle Bus (MVB) inside each vehicle and of the Wire Train Bus (WTB) to connect the different vehicles. The TCN components have been standardized in IEC 61375.


Multifunction vehicle bus (MVB)

The multifunction vehicle bus connects individual nodes within a vehicle or in a closed train set. Unlike the WTB there is no requirement on a single international connector standard for the
vehicle bus A vehicle bus is a specialized internal communications network that interconnects components inside a vehicle (e.g., automobile, bus, train, industrial or agricultural vehicle, ship, or aircraft). In electronics, a bus is simply a device that con ...
inside a coach, locomotive or train set – instead there are three predefined media and connector classes: # OGF ( optical glass fibres) uses 240 μm fibers for a line distance of 2000 m, # EMD (electrical medium distance) uses shielded twisted pair with RS 485 transmitters and transformers for galvanical isolation), for a length reaching 200 m and # ESD (electrical short distance) uses a simple backplane wiring without galvanic isolation, for which case the cable may be up to 20 m in length. The plugs and sockets are the same as used by Profibus (with two 9-pin Sub-D sockets per electrical device). For OGF, the media sources are connected by repeaters (signal generators) being joined on a central star coupler  A repeater is also used for the transition from one medium to another. There is no inauguration, the addresses are statically allocated. The number of addressable devices depends on the configuration of the vehicle bus – there may be up to 4095 simple
sensors A sensor is a device that produces an output signal for the purpose of sensing a physical phenomenon. In the broadest definition, a sensor is a device, module, machine, or subsystem that detects events or changes in its environment and sends ...
/
actuators An actuator is a component of a machine that is responsible for moving and controlling a mechanism or system, for example by opening a valve. In simple terms, it is a "mover". An actuator requires a control device (controlled by control signal) an ...
(Class I) and up to 255 programmable stations (Class 2, with configuration slots). The physical level is using transmissions at a 1.5 Mbit/s data rate using Manchester II encoding. The maximum distance is determined on the restriction of a maximum allowed reply delay of 42.7 µs (where for longer distances a second mode is used that allows up to 83.4 μs with reduced throughput, in case MVB is used for switchgear on the track side) while most system parts communicate with a response time of a typical 10µs.


History

MVB was derived from the P215 bus developed by Brown Boveri Cie, Switzerland (now
ABB ABB Ltd. is a Swedish- Swiss multinational corporation headquartered in Zürich, Switzerland. The company was formed in 1988 when Sweden's Allmänna Svenska Elektriska Aktiebolaget (ASEA) and Switzerland's Brown, Boveri & Cie merged to crea ...
), incorporating the publisher/subscriber principle from early field busses ( DATRAS). Back in 1984,
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including E ...
defined the requirement specifications for busses to be used in electrical substation in collaboration with
IEC SC65C The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
. MVB presents many similarities with the FIP field bus (originally from French "''Flux d'Information vers le Processus''", relabeled as Factory Instrumentation Protocol or some references also use the hybrid "Flux Information Protocol") that was developed in the French NFC 46602 standard series. Since both stemmed from the same
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including E ...
specifications. This explains why MVB and FIP have similar operation (cyclic and event-driven), only the arbitration method in case of multiple access differs, as MVB used a binary bisection mode relying of collision detection while FIP piggy-backed a "look-at-me" bit over periodic data. Efforts to merge FIP and MVB failed at the stubbornness of the two parties. MVB, Profibus and
WorldFIP The Factory Instrumentation Protocol or FIP is a standardized field bus protocol. Its most current definition can be found in the European Standard EN50170. History The FIP standard is based on a French initiative in 1982 to create a requirements ...
were proposed as a substation bus in
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including E ...
, but to avoid parallel solutions,
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including E ...
decided that none will be used and favored
Ethernet Ethernet () is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 1 ...
as a common denominator. The MVB frames are not compatible with IEC 61158-2 fieldbus frames as it omits most of the preamble synchronization (which is not required if zero-crossing detection is possible). The paradox situation is that the IEC 61158 field bus and MVB physical layer were developed by the same persons in
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including E ...
. The difference came from the
fieldbus Fieldbus is the name of a family of industrial computer networks used for real-time distributed control. Fieldbus profiles are standardized by the International Electrotechnical Commission (IEC) as IEC 61784/61158. A complex automated industrial ...
physical layer which assumes a phase-locked loop to decode the Manchester data, requiring a preamble to synthonize the decoder, while MVB operated principally with optical fibres where this method is useless, MVB's decoding relies on zero-crossing detectors and Manchester pattern recognition. However most of the modern development and test equipment can equally communicate WTB/MVB frames as well as Profibus frames on the line as the telegram structure similar to Profibus. The
WorldFIP The Factory Instrumentation Protocol or FIP is a standardized field bus protocol. Its most current definition can be found in the European Standard EN50170. History The FIP standard is based on a French initiative in 1982 to create a requirements ...
connectors found usage in train equipment in
France France (), officially the French Republic ( ), is a country primarily located in Western Europe. It also comprises of overseas regions and territories in the Americas and the Atlantic, Pacific and Indian Oceans. Its metropolitan area ...
and North America (by Bombardier) until a joined effort on a common UIC train bus was started (with Siemens and other industry partners) that led to the WTB/MVB standard in late 1999.


Alternate vehicle buses

The MVB standard was introduced to replace the multitude of field buses in the train equipment. Despite the advantages of the MVB field bus, many vehicle buses are still built from
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
,
WorldFIP The Factory Instrumentation Protocol or FIP is a standardized field bus protocol. Its most current definition can be found in the European Standard EN50170. History The FIP standard is based on a French initiative in 1982 to create a requirements ...
(in
France France (), officially the French Republic ( ), is a country primarily located in Western Europe. It also comprises of overseas regions and territories in the Americas and the Atlantic, Pacific and Indian Oceans. Its metropolitan area ...
),
LonWorks LonWorks or Local Operating Network is an open standard (ISO/IEC 14908) for networking platforms specifically created to address the needs of control applications. The platform is built on a protocol created by Echelon Corporation for networking ...
(in the
USA The United States of America (U.S.A. or USA), commonly known as the United States (U.S. or US) or America, is a country primarily located in North America. It consists of 50 states, a federal district, five major unincorporated territori ...
) and Profibus components. While the
WorldFIP The Factory Instrumentation Protocol or FIP is a standardized field bus protocol. Its most current definition can be found in the European Standard EN50170. History The FIP standard is based on a French initiative in 1982 to create a requirements ...
,
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
,
Lonworks LonWorks or Local Operating Network is an open standard (ISO/IEC 14908) for networking platforms specifically created to address the needs of control applications. The platform is built on a protocol created by Echelon Corporation for networking ...
and Profinet are controlled by international manufacturer associations targeting a wide range of application, MVB was tailored to the rolling stock application, with the goal of plug-compatibility, and therefore allows no options. This was intentional as the fight between the field busses raged in the 1990s and the decision of the
IEC The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
that any of the eight field busses was a standard did not help plug-compatibility. MVB modules are more expensive than for instance
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
or
LonWorks LonWorks or Local Operating Network is an open standard (ISO/IEC 14908) for networking platforms specifically created to address the needs of control applications. The platform is built on a protocol created by Echelon Corporation for networking ...
components. This is not due to the communication technology: most devices implement the MVB protocol machine in a small area of an FPGA which is today anyhow present, and the costliest component remains the connector. But railways certification is costly and not always needed for uncritical applications such as comfort and passenger information. When total cost of ownership is considered, the cost of the hardware elements can easily be outweighed by additional engineering costs in the railways market with its small series. In the
USA The United States of America (U.S.A. or USA), commonly known as the United States (U.S. or US) or America, is a country primarily located in North America. It consists of 50 states, a federal district, five major unincorporated territori ...
, the IEEE RTVISC evaluated both MVB and LON as vehicle and train bus. The
IEEE The Institute of Electrical and Electronics Engineers (IEEE) is a 501(c)(3) professional association for electronic engineering and electrical engineering (and associated disciplines) with its corporate office in New York City and its operat ...
finally decided to standardize both in IEEE 1374, with a clear separation of tasks: * MVB for critical operation such as traction control and signalling in the driver's cab, * LON for uncritical and slow data transfer, but low-cost connections such as passenger displays and diagnostics. This separation is not always observed. Additionally more and more components are added to rail vehicles that need far more bandwidth than any field bus can provide (e.g. for
video surveillance Closed-circuit television (CCTV), also known as video surveillance, is the use of video cameras to transmit a signal to a specific place, on a limited set of monitors. It differs from broadcast television in that the signal is not openly tr ...
), so
switched Ethernet A network switch (also called switching hub, bridging hub, and, by the IEEE, MAC bridge) is networking hardware that connects devices on a computer network by using packet switching to receive and forward data to the destination device. A netw ...
IEEE 802.3 with 100 Mbit/s is being introduced into train sets (according to the EN 50155 profile). Still all the alternate vehicle buses are connected to the Wire Train Bus. MVB is similar to FlexRay, both have the "process data", which is called "static segment" in FlexRay, and "message data", which is the "dynamic segment" and are driven by a fixed TDMA scheme. Running FlexRay with 2.5 Mbit, an
RS-485 RS-485, also known as TIA-485(-A) or EIA-485, is a standard defining the electrical characteristics of drivers and receivers for use in serial communications systems. Electrical signaling is balanced, and multipoint systems are supported. The s ...
physical layer and only one "coldstarter" would lead to a very similar behavior in respect to the application. Despite the similarities, no rail-manufacturer has considered FlexRay, since they valuated a common solution higher than a multitude of better busses. Conversely, in 1999, the automotive industry evaluated MVB (in an extended 24 Mbit/s version), but dropped it because of the costs, which should be unreasonably low for the mass-market of millions of vehicles.


Wire train bus (WTB)

The wire train bus has been designed for international passenger trains with variable composition, consisting of up to 22 vehicles. The medium consists of a duplicated
shielded twisted pair Twisted pair cabling is a type of wiring used for communications in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted ba ...
cable, which runs in the UIC cables between the vehicles. The connector between the vehicles is the 18-pole UIC connector. Since connectors are exposed and can oxidize, a current pulse is applied at connection establishment to evaporate the oxide layer, called fritting. The standard connector for the WTB nodes is a DIN 9 pin connector. The physical level uses
RS-485 RS-485, also known as TIA-485(-A) or EIA-485, is a standard defining the electrical characteristics of drivers and receivers for use in serial communications systems. Electrical signaling is balanced, and multipoint systems are supported. The s ...
levels at 1 Mbit/s data rate. The encoding uses a Manchester II code and a
HDLC High-Level Data Link Control (HDLC) is a bit-oriented code-transparent synchronous data link layer protocol developed by the International Organization for Standardization (ISO). The standard for HDLC is ISO/IEC 13239:2002. HDLC provides both ...
frame protocol with proper voltage balancing to avoid DC components in the
galvanic isolation Galvanic isolation is a principle of isolating functional sections of electrical systems to prevent current flow; no direct conduction path is permitted.John Huntington ''Show Networks and Control Systems: Formerly Control Systems for Live ...
transformers. The Manchester decoder uses a phase/quadrature demodulation (not
RS-485 RS-485, also known as TIA-485(-A) or EIA-485, is a standard defining the electrical characteristics of drivers and receivers for use in serial communications systems. Electrical signaling is balanced, and multipoint systems are supported. The s ...
, that operates with zero-crossings) which allows to span 750 m under worst-case conditions, especially when only the two extremity vehicles are equipped, as is the case with multiple traction for freight trains. No repeaters are foreseen since vehicles in between can have discharged batteries. A unique property of the WTB is the train inauguration (In German: ''Zugtaufe'') in which the newly connected vehicles receive an address in sequence and can identify the vehicle side (called ''port'' and ''starboard'' like in the marine) so that doors open on the correct side. Up to 32 addresses can be dynamically allocated. When two train compositions join, the addresses are reallocated to form a new composition of vehicles with a sequential address. Vehicles without WTB node ("c''onduction vehicles''") are not counted. The frames have a maximum payload of 1024 bits. The WTB operates cyclically to provide deterministic operation, with a period of 25 ms, used mainly for the traction control. The WTB also supports sporadic data transmission for diagnostics. The content of the periodic and sporadic frames is governed by the UIC 556 standard. Since frame size is limited, a version of TCP with reduced overhead was used for message segmenting and reassembly, that at the same time allows to cope with changes in composition, called RTP ( Real-Time Protocol).


Alternate train buses


History

The WTB was derived from the German DIN bus developed by
ABB Henschel Henschel & Son (german: Henschel und Sohn) was a German company, located in Kassel, best known during the 20th century as a maker of transportation equipment, including locomotives, trucks, buses and trolleybuses, and armoured fighting vehicle ...
(now Bombardier). It benefited from the phase/quadrature decoding provided by
Italy Italy ( it, Italia ), officially the Italian Republic, ) or the Republic of Italy, is a country in Southern Europe. It is located in the middle of the Mediterranean Sea, and its territory largely coincides with the homonymous geographical ...
and from an improved train inauguration provided by Switzerland, based on the experience with the FSK multiple traction bus of ABB Secheron, Geneva used in the SBB freight trains. The physical layer of WTB shows similarities with the
WorldFIP The Factory Instrumentation Protocol or FIP is a standardized field bus protocol. Its most current definition can be found in the European Standard EN50170. History The FIP standard is based on a French initiative in 1982 to create a requirements ...
field bus ( EN 50170 part 4) - its "voltage mode" did use 1 Mbit/s and a maximum of 32 stations on the bus with a maximum length of 750 meters, the use of FIP
transceivers In radio communication, a transceiver is an electronic device which is a combination of a radio ''trans''mitter and a re''ceiver'', hence the name. It can both transmit and receive radio waves using an antenna, for communication purposes. Thes ...
was studied early in the TCN evaluation, but the Phase/Quadrature decoding was used instead.


Usage

The TCN is used in most of the modern train control systems usually connecting the vehicles with an 18-pin UIC 558, including: * Deutsche Bahn:
ICE T DBAG Class 411 and Class 415 are German tilting electric multiple-unit high-speed trains in service with DB Fernverkehr, commonly known as ICE T. Development Following the successful inauguration of the Intercity-Express system in 1991 ...
, ICE-TD,
ICE 3 ICE 3, or Intercity-Express 3, is a family of high-speed electric multiple unit trains operated by Deutsche Bahn. It includes classes 403, 406, 407 and 408, which are known as ICE 3, ICE 3M, New ICE 3 and ICE 3neo respectively. Three multisystem ...
and TRAXX AC2 P160 * Swiss Federal Railways:
IC2000 The IC 2000 is a double-deck train in Switzerland and is run by Swiss Federal Railways (SBB-CFF-FFS) as part of its InterCity service. Top speed is 200 km/h. The train set can be composed of up to 10 coaches and provides close to 1,000 se ...
and EW IV ( de) *
Austrian Federal Railways Austrian may refer to: * Austrians, someone from Austria or of Austrian descent ** Someone who is considered an Austrian citizen, see Austrian nationality law * Austrian German dialect * Something associated with the country Austria, for example: ...
: All
Railjet Railjet is a high-speed rail service in Europe operated by Austrian Federal Railways (ÖBB) and Czech Railways (ČD). Branded as ''Railjet Express (RJX)'' for the fastest services and as ''Railjet (RJ)'' for services with additional stops, it w ...
and Talent trains


Further reading

* Ethernet Train Backbone * Ethernet Consist Network *
WorldFIP The Factory Instrumentation Protocol or FIP is a standardized field bus protocol. Its most current definition can be found in the European Standard EN50170. History The FIP standard is based on a French initiative in 1982 to create a requirements ...
*
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
*
Lonworks LonWorks or Local Operating Network is an open standard (ISO/IEC 14908) for networking platforms specifically created to address the needs of control applications. The platform is built on a protocol created by Echelon Corporation for networking ...
* Profinet * FlexRay


Notes and references


External links

* * {{Computer-bus Rail technologies Serial buses Automated track-bound traffic