A radio-frequency quadrupole (RFQ) beam cooler is a device for
particle beam cooling Particle beam cooling is the process of improving the quality of particle beams produced by particle accelerators, by reducing the emittance. Techniques for particle beam cooling include: * Stochastic cooling * Electron coolingI. Meshkov, Electro ...
, especially suited for
ion beam An ion beam is a type of charged particle beam consisting of ions. Ion beams have many uses in electronics manufacturing (principally ion implantation) and other industries. A variety of ion beam sources exists, some derived from the mercury ...
s. It lowers the temperature of a
particle beam A particle beam is a stream of charged or neutral particles. In particle accelerators, these particles can move with a velocity close to the speed of light. There is a difference between the creation and control of charged particle beams and neu ...
by reducing its energy dispersion and emittance, effectively increasing its brightness ( brilliance). The prevalent mechanism for cooling in this case is buffer-gas cooling, whereby the beam loses energy from collisions with a light, neutral and inert gas (typically
helium Helium (from el, ἥλιος, helios, lit=sun) is a chemical element with the symbol He and atomic number 2. It is a colorless, odorless, tasteless, non-toxic, inert, monatomic gas and the first in the noble gas group in the periodic table. ...
). The cooling must take place within a confining field in order to counteract the thermal diffusion that results from the ion-atom collisions. The
quadrupole mass analyzer The quadrupole mass analyzer, originally conceived by Nobel Laureate Wolfgang Paul and his student Helmut Steinwedel, also known as quadrupole mass filter, is one type of mass analyzer used in mass spectrometry. As the name implies, it consists of ...
(a
radio frequency quadrupole A radio-frequency quadrupole (RFQ) is a linear accelerator component generally used at low beam energies, roughly 2keV to 3MeV. It is similar in layout to a quadrupole mass analyser but its purpose is to accelerate a single-species beam (a beam o ...
used as a mass filter) was invented by Wolfgang Paul in the late 1950s to early 60s at the
University of Bonn The Rhenish Friedrich Wilhelm University of Bonn (german: Rheinische Friedrich-Wilhelms-Universität Bonn) is a public research university located in Bonn, North Rhine-Westphalia, Germany. It was founded in its present form as the ( en, Rhine U ...
, Germany. Paul shared the 1989
Nobel Prize in Physics ) , image = Nobel Prize.png , alt = A golden medallion with an embossed image of a bearded man facing left in profile. To the left of the man is the text "ALFR•" then "NOBEL", and on the right, the text (smaller) "NAT•" then " ...
for his work. Samples for mass analysis are ionized, for example by laser (
matrix-assisted laser desorption/ionization In mass spectrometry, matrix-assisted laser desorption/ionization (MALDI) is an ionization technique that uses a laser energy absorbing matrix to create ions from large molecules with minimal fragmentation. It has been applied to the analysis of ...
) or discharge (
electrospray The name electrospray is used for an apparatus that employs electricity to disperse a liquid or for the fine aerosol resulting from this process. High voltage is applied to a liquid supplied through an emitter (usually a glass or metallic capilla ...
or
inductively coupled plasma An inductively coupled plasma (ICP) or transformer coupled plasma (TCP) is a type of plasma source in which the energy is supplied by electric currents which are produced by electromagnetic induction, that is, by time-varying magnetic fields. ...
) and the resulting beam is sent through the RFQ and "filtered" by scanning the operating parameters (chiefly the RF amplitude). This gives a mass spectrum, or fingerprint, of the sample. Residual gas analyzers use this principle as well.


Applications of ion cooling to nuclear physics

Despite its long history, high-sensitivity high-accuracy
mass measurement A scale or balance is a device used to measure weight or mass. These are also known as mass scales, weight scales, mass balances, and weight balances. The traditional scale consists of two plates or bowls suspended at equal distances from a ...
s of
atomic nuclei The atomic nucleus is the small, dense region consisting of protons and neutrons at the center of an atom, discovered in 1911 by Ernest Rutherford based on the 1909 Geiger–Marsden gold foil experiment. After the discovery of the neutron ...
continue to be very important areas of research for many branches of
physics Physics is the natural science that studies matter, its fundamental constituents, its motion and behavior through space and time, and the related entities of energy and force. "Physical science is that department of knowledge which r ...
. Not only do these measurements provide a better understanding of nuclear structures and nuclear forces but they also offer insight into how matter behaves in some of Nature's harshest environments. At facilities such as ISOLDE at
CERN The European Organization for Nuclear Research, known as CERN (; ; ), is an intergovernmental organization that operates the largest particle physics laboratory in the world. Established in 1954, it is based in a northwestern suburb of Gene ...
and
TRIUMF TRIUMF is Canada's national particle accelerator centre. It is considered Canada's premier physics laboratory, and consistently regarded as one of the world's leading subatomic physics research centers. Owned and operated by a consortium of uni ...
in Vancouver, for instance, measurement techniques are now being extended to short-lived radionuclei that only occur naturally in the interior of exploding stars. Their short half-lives and very low production rates at even the most powerful facilities require the very highest in sensitivity of such measurements.
Penning trap A Penning trap is a device for the storage of charged particles using a homogeneous axial magnetic field and an inhomogeneous quadrupole electric field. This kind of trap is particularly well suited to precision measurements of properties of io ...
s, the central element in modern high-accuracy high-sensitivity mass measurement installations, enable measurements of accuracies approaching 1 part in 10^11 on single ions. However, to achieve this Penning traps must have the ion to be measured delivered to it very precisely and with certainty that it is indeed the desired ion. This imposes severe requirements on the apparatus that must take the atomic nucleus out of the target in which it has been created, sort it from the myriad of other ions that are emitted from the target and then direct it so that it can be captured in the measurement trap. Cooling these ion beams, particularly radioactive ion beams, has been shown to drastically improve the accuracy and sensitivity of mass measurements by reducing the
phase space In dynamical system theory, a phase space is a space in which all possible states of a system are represented, with each possible state corresponding to one unique point in the phase space. For mechanical systems, the phase space usually ...
of the ion collections in question. Using a light neutral background gas, typically helium, charged particles originating from on-line mass separators undergo a number of soft collisions with the background gas molecules resulting in fractional losses of the ions' kinetic energy and a reduction of the ion ensemble's overall energy. In order for this to be effective however, the ions need to be contained using transverse radiofrequency quadrupole (RFQ) electric fields during the collisional cooling process (also known as
buffer gas A buffer gas is an inert or nonflammable gas. In the Earth's atmosphere, nitrogen acts as a buffer gas. A buffer gas adds pressure to a system and controls the speed of combustion with any oxygen present. Any inert gas such as helium, neon, or ar ...
cooling). These RFQ coolers operate on the same principles as
quadrupole ion trap A quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented the device and shared the N ...
s and have been shown to be particularly well suited for buffer gas cooling given their capacity for total confinement of ions having a large dispersion of velocities, corresponding to kinetic energies up to tens of electron volts. A number of the RFQ coolers have already been installed at research facilities around the world and a list of their characteristics can be found below.


List of facilities containing RFQ Coolers


See also

*
Quadrupole mass analyzer The quadrupole mass analyzer, originally conceived by Nobel Laureate Wolfgang Paul and his student Helmut Steinwedel, also known as quadrupole mass filter, is one type of mass analyzer used in mass spectrometry. As the name implies, it consists of ...


References


Bibliography

* * * * * * * * * * {{refend


External links


LEBIT Project NSCL/MSUTITAN: TRIUMF's Ion Trap for Atomic and Nuclear science
* ttps://web.archive.org/web/20060820082349/http://www.gsi.de/forschung/ap/projects/shiptrap/index_e.html The SHIPTRAP Experimentbr>The ISCOOL project