Nuclear Plant Doel
   HOME

TheInfoList



OR:

The Doel Nuclear Power Station is one of two
nuclear power plant A nuclear power plant (NPP) is a thermal power station in which the heat source is a nuclear reactor. As is typical of thermal power stations, heat is used to generate steam that drives a steam turbine connected to a electric generator, generato ...
s in Belgium. The plant includes 4 reactors. The site is located on the bank of the Scheldt river, near the village of Doel in the Flemish province of East Flanders, on the outskirts of the city of
Antwerp Antwerp (; nl, Antwerpen ; french: Anvers ; es, Amberes) is the largest city in Belgium by area at and the capital of Antwerp Province in the Flemish Region. With a population of 520,504,
. The station is operated and majority-owned by
vertically-integrated In microeconomics, management and international political economy, vertical integration is a term that describes the arrangement in which the supply chain of a company is integrated and owned by that company. Usually each member of the supply c ...
French energy corporation Engie SA through its 100%-owned Belgian subsidiary Electrabel. EDF Luminus has a 10.2% stake in the two newest units. The Doel plant employs 963 workers and covers an area of . The plant represents about 15% of Belgium's total electricity production capacity and 30% of the total electricity generation. Nuclear energy typically provides half of Belgium's domestically-generated electricity and is the country's lowest-cost source of power. The station is located in the most densely populated area for any nuclear power station in Europe as of 2011, with 9 million inhabitants within a radius of .


History

The powerstation was built by public utility EBES (Sociétés Réunies d'Energie du Bassin de l'Escaut), which in 1990 merged with Intercom and Unerg to become Electrabel. The plant was designed by the Belgian engineering firm Tractebel. Doel 1 and 2 are twin units that entered commercial operation in 1975. Doel 3 entered commercial operation in 1982 and Doel 4 in 1985. Doel 1, 2 and 4 were constructed by the ACECOWEN ( ACEC- Cockerill- Westinghouse)
consortium A consortium (plural: consortia) is an association of two or more individuals, companies, organizations or governments (or any combination of these entities) with the objective of participating in a common activity or pooling their resources for ...
. While Doel 3 was constructed by FRAMACEC ( Framatome- ACEC- Cockerill). Earthworks for Doel 5, a 1400 MW reactor also known as N8 (8th nuclear reactor in Belgium), were stopped in 1988. Participation in the French twin plant in
Chooz Chooz () can denote several things: * Chooz, Ardennes is a French commune ** The Chooz Nuclear Power Plant ** Chooz (experiment) was a physics experiment using the reactor as a neutrino source ** Double Chooz Double Chooz was a short-baseline ne ...
however continued. French industry was compensated for already ordered components.


Reactors

The plant consists of four second-generation pressurized water reactors with a total net capacity of 2,925 MWe, smaller than Belgium's other nuclear power plant at Tihange. Its four units are rated as follows:


Design

The design of the plant is reviewed completely every ten years through a TJH (tienjaarlijkse herziening), a legal obligation imposed by the Belgian state and the operation licence of the plant. The purpose of the review is to update the plant to the most recent international safety standards.


Meteorological conditions

Various weather conditions have been analysed including rain,
seiches A seiche ( ) is a standing wave in an enclosed or partially enclosed body of water. Seiches and seiche-related phenomena have been observed on lakes, reservoirs, swimming pools, bays, harbors, caves and seas. The key requirement for formation ...
, tsunamis,
floods A flood is an overflow of water ( or rarely other fluids) that submerges land that is usually dry. In the sense of "flowing water", the word may also be applied to the inflow of the tide. Floods are an area of study of the discipline hydrolog ...
,
earthquakes An earthquake (also known as a quake, tremor or temblor) is the shaking of the surface of the Earth resulting from a sudden release of energy in the Earth's lithosphere that creates seismic waves. Earthquakes can range in intensity, from ...
, wind, tornados, lightning, snow,
hail Hail is a form of solid precipitation. It is distinct from ice pellets (American English "sleet"), though the two are often confused. It consists of balls or irregular lumps of ice, each of which is called a hailstone. Ice pellets generally fal ...
, extreme temperatures,
cyclones In meteorology, a cyclone () is a large air mass that rotates around a strong center of low atmospheric pressure, counterclockwise in the Northern Hemisphere and clockwise in the Southern Hemisphere as viewed from above (opposite to an anti ...
, sandstorms and waterspouts.


Earthquakes

Since the design of Doel 3 and 4 and the first TJH of Doel 1 and 2 the reactors were designed to be subject to earthquakes such as the Richter scale 5.6 Zulzeke-Nukerke quake in 1938. At a distance of 75 km to the epicentre, this is the most significant historical earthquake for Doel. The earthquake resulted in horizontal ground accelerations of up to 0.058 '' g'' and formed the design base for Doel 1 and 2. Doel 3 and 4 were designed for peak ground accelerations of 0.1 ''g''. After the
Fukushima Daiichi nuclear disaster The was a nuclear accident in 2011 at the Fukushima Daiichi Nuclear Power Plant in Ōkuma, Fukushima, Japan. The proximate cause of the disaster was the 2011 Tōhoku earthquake and tsunami, which occurred on the afternoon of 11 March 2011 and ...
probabilistic safety studies performed by the Royal Observatory of Belgium predicted an earthquake with peak ground acceleration of up to 0.081 ''g'' every 10,000 years. The design was subsequently analysed for earthquakes up to 0.17 ''g'', which is equivalent to a 1 in 100,000 year earthquake.


Floods

The Doel plant was originally designed for a 10,000 year flood of 9.13 m TAW (Tweede Algemene Waterpassing). The highest measured level was 8.10 m TAW during the
North Sea flood of 1953 The 1953 North Sea flood was a major flood caused by a heavy storm surge that struck the Netherlands, north-west Belgium, England and Scotland. Most sea defences facing the surge were overwhelmed, causing extensive flooding. The storm and flo ...
. The site was filled to 8.86 m TAW during construction and fitted with a seadyke of 12.08 m TAW. The other dykes around the site have a height of 11 m TAW. Probabilistic studies performed after Fukushima showed the height of a 10,000 year flood had slightly increased to 9.35 m TAW, 22 cm higher than the studies performed in the 1960s. The highest possible tsunami is lower than 0.5 m. During post-Fukushima stress tests a dyke failure with a water level of 10.2 m was simulated. Due to the presence of bulkheads and pedestals in the buildings no safety functions were endangered.


Safety systems

Besides regular primary level safety systems, in common with most nuclear power plants in the world, Doel has secondary level safety systems that can autonomously keep the power plant safe during large external accidents such as the crash of an aircraft, external explosions or loss of the primary level. The primary level systems have a redundancy of three or four times. The secondary level systems are 2x100% or 3x50%. and have their own heatsink separate from the primary heatsink, the Scheldt river. Doel 1 and 2 have aircoolers while Doel 3 and 4 have three separate artificial cooling ponds.


Double containment

Nuclear plants are designed with multiple physical barriers to prevent fission products escaping into the environment. In the case of a pressurized water reactor there are three barriers: the fuel cladding which surround the fuel pallets, the primary circuit which houses the fuel rods and finally the containment building in which the primary circuit is built. In Belgium it was decided to add an extra double containment barrier. The primary containment, a steel sphere in Doel 1 and 2 and a pre-stressed concrete cylinder with steel liner in Doel 3 and 4, is surrounded by a secondary containment made of 1.2 to 1.3 m thick reinforced concrete. The space between both containments is kept at sub-atmospheric pressure and filters are used to filter potential leaks of the primary containment.


Filtered containment venting system

In answer to a question of
die Grünen Die Grünen (German for "the Greens") may refer to: *The Greens – The Green Alternative The Greens – The Green Alternative (german: Die Grünen – Die Grüne Alternative, ) is a green political party in Austria. The party was founded in 19 ...
in the Bundestag, the German parliament, the German government replied that the Belgian nuclear power plants do not have filtered containment venting systems installed. In German nuclear reactors these were already built in after the
Chernobyl disaster The Chernobyl disaster was a nuclear accident that occurred on 26 April 1986 at the No. 4 reactor in the Chernobyl Nuclear Power Plant, near the city of Pripyat in the north of the Ukrainian SSR in the Soviet Union. It is one of only two nuc ...
in 1986. Other countries followed this example, latest after the Fukushima nuclear disaster. This kind of system allows for the containment pressure to be relieved in the event of a severe accident. The non-condensible gases that cause pressure within containment to rise are released through a stack (or chimney) via a filtration system that removes large quantities of fission products from the effluent. As part of the stress tests following the Fukushima incident, this issue had already been identified to be included in the stress-test action plan (BEST). Construction of containment filter venting systems at Doel 3 and 4 was completed in 2017, with Doel 1 and 2 scheduled to be operational in 2020.


Turbo feed pump

Every reactor has at least one steam driven
feedwater pump A boiler feedwater pump is a specific type of pump used to pump feedwater into a steam boiler. The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are ...
which can supply the steam generators with water to cool down the reactor. These turbine driven pumps can cool down the plant even when no electrical power is available to power the motor driven feedwater pumps during a station blackout like the
Fukushima Daiichi nuclear disaster The was a nuclear accident in 2011 at the Fukushima Daiichi Nuclear Power Plant in Ōkuma, Fukushima, Japan. The proximate cause of the disaster was the 2011 Tōhoku earthquake and tsunami, which occurred on the afternoon of 11 March 2011 and ...
. In a boiling water reactor, like those in Fukushima, the heat removal capacity of the pumps is limited as the steam that drives the turbines is radioactive and thus has to be stored. This is not the case with a PWR due to the use of steam generators. Steam can simply be removed via a
chimney A chimney is an architectural ventilation structure made of masonry, clay or metal that isolates hot toxic exhaust gases or smoke produced by a boiler, stove, furnace, incinerator, or fireplace from human living areas. Chimneys are typic ...
. Water supplies on site are sufficient to keep the plant safe for dozens of days.


Nuclear waste

Light and intermediate level waste, which represents 99% of the volume of waste, is treated on site in the WAB (Water and Waste Treatment Building). Category A waste with half lives of less than 30 years is transported to Belgoprocess in Dessel for surface disposal. High level waste was originally recycled to MOX fuel, and re-used in the Doel 3 reactor. In 1993, the Belgian federal government placed a moratorium on the reprocessing activities in order to research other options. Pending further decisions regarding the moratorium, spent fuel was stored on site in dry cask storage. Final disposal of the waste is being researched at the HADES underground laboratory 225m deep in the Boom Clay.
Nuclear transmutation Nuclear transmutation is the conversion of one chemical element or an isotope into another chemical element. Nuclear transmutation occurs in any process where the number of protons or neutrons in the nucleus of an atom is changed. A transmutatio ...
of the waste is also being researched with the MYRRHA project. In October 2013, NIRAS suspended Electrabel's licence to treat two types of waste, concentrate and resins, after foam was discovered on previously treated waste due to an alkali–silica reaction. Electrabel has started a licensing procedure to use the process used in Tihange to process future waste. This process can take up to two years and in the meantime the waste in question is stored on site.


Incidents


2011 Doel 4 INES-2 incident

There has been one INES-2 incident on the International Nuclear Event Scale. After the replacement of an auxiliary feedwater turbopump, during the 2009-outage, one of the three feedwater pumps of the first level was adjusted to a lower level of rotational speed, delivering insufficient flow rates during certain circumstances. The two other first level feedwater pumps and three second level feedwater pumps were still available. The incident was rated 2 on the scale rather than 1 because the "Federal Agency for Nuclear Control felt that Electrabel waited a little too long to report the incident".


2012 Doel 3 pressure vessel cracks

In June 2012 Doel 3 was shut down for its third scheduled 10-year in-service inspection. Ultrasound inspections revealed a number of cracks in the lowest forged ring of the reactor pressure vessel. The cracks were determined to be an original manufacturing defect, not related to tension, and theoretically of no risk. The reactor remained offline for further inspections and assessment for a year. Eventually the nuclear regulator judged short-term safety concerns initially raised had been solved in a satisfactory manner and that the reactor could operate safely, and it was restarted in June 2013.


2014 Doel 4 turbine incident

In August 2014, there was a major incident in the non-nuclear part of the plant. The main turbine overheated while operating without oil. A valve had been deliberately opened, which rapidly evacuated 65,000 litres of oil to an underground storage tank. The procedure was normally used in case of fire. The valve was normally secured by a padlock. Authorities and the plant operator suspected an act of deliberate sabotage. The unit was eventually back on grid by 19 December 2014. Combined with the outage of Doel 3 and Tihange 2, blackouts were not ruled out for the winter period of 2014–2015. In December 2016, Electrabel requested that the justice department in Brussels prolong the search for the perpetrator of the turbine sabotage. Repairs cost more than 100 million euros.


Other


Transmission

The power plant has two
electrical substation A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and ...
s. Two transmission lines run to
Zandvliet Zandvliet () is a former Belgian town forming part of the Antwerp district of Berendrecht-Zandvliet-Lillo. The place dates back to 1135 when it was known as ''Santflit'', meaning "a navigable passage through sand". In 1622 the Spaniard Ambrogio ...
and Kallo from the 150 kV station. The 380 kV station has three lines to
Avelgem Avelgem (; vls, Oavelgem) is a municipality located in the Belgian province of West Flanders. The municipality comprises the towns of Avelgem proper, Bossuit, Kerkhove, Outrijve and Waarmaarde. On January 1, 2006, Avelgem had a total populati ...
, Mercator in Kruibeke and Zandvliet. Elia is the transmission system operator. The line to Zandvliet crosses the Scheldt River using one of the highest transmission towers in Europe. The tower is high and built on a caisson in the middle of the river. The line is part of the interconnection between the Dutch and Belgian grids.


Cooling towers

With a height of 169 metres(554 feet), the two cooling towers are the most visible structures in the Port of Antwerp. Due to their proximity to the Dutch-Belgian border, the towers and the accompanying wet steam can be seen over large areas of the
Dutch provinces There are twelve provinces of the Netherlands (), representing the administrative layer between the national government and the local municipalities, with responsibility for matters of subnational or regional importance. The most populous prov ...
of Zeeland and western North Brabant. Since the spring of 1996, one of the cooling towers has hosted a nest of
peregrine falcon The peregrine falcon (''Falco peregrinus''), also known as the peregrine, and historically as the duck hawk in North America, is a Cosmopolitan distribution, cosmopolitan bird of prey (Bird of prey, raptor) in the family (biology), family Falco ...
s.


Security

On 15 March 2016, the federal government of Belgium decided 140 soldiers would guard the nuclear sites and that Electrabel should cover the costs. In late 2015 it had already been decided that a specially trained department of the federal police would guard the nuclear sites. After the
2016 Brussels bombings On 22 March 2016, two coordinated terrorist attacks in Brussels, Belgium were carried out by the Islamic State. Three coordinated suicide bombings occurred: two at Brussels Airport in Zaventem, and one at Maalbeek metro station on the Brussels m ...
, on 22 March the nuclear powerplants of Doel and Tihange were preventively evacuated, the standard procedure when the threat level in Belgium reaches Level 4. The powerplants continued running with minimal staff.


See also

* List of nuclear power stations * Tihange Nuclear Power Station


References


External links


Signature of the convention between ENGIE and the Belgian government (1 December 2015)

Reports of radiological surveillance in Belgium
{{Authority control Doel Nuclear power stations using pressurized water reactors Nuclear technology in Belgium Buildings and structures in East Flanders Electrabel nuclear power stations Beveren 1975 establishments in Belgium