In the context of IBM
mainframe computer A mainframe computer, informally called a mainframe or big iron, is a computer used primarily by large organizations for critical applications like bulk data processing for tasks such as censuses, industry and consumer statistics, enterpris ...
s in the
S/360 The IBM System/360 (S/360) is a family of mainframe computer A mainframe computer, informally called a mainframe or big iron, is a computer used primarily by large organizations for critical applications like bulk data processing for t ...
line, a data set (IBM preferred) or dataset is a computer file having a record organization. Use of this term began with, e.g.,
DOS/360 Disk Operating System/360, also DOS/360, or simply DOS, is the discontinued first member of a sequence of operating systems for IBM System/360, System/370 and later mainframes. It was announced by IBM on the last day of 1964, and it was first d ...
, OS/360, and is still used by their successors, including the current z/OS. Documentation for these systems historically preferred this term rather than '' file''. A data set is typically stored on a direct access storage device (DASD) or
magnetic tape Magnetic tape is a medium for magnetic storage made of a thin, magnetizable coating on a long, narrow strip of plastic film. It was developed in Germany in 1928, based on the earlier magnetic wire recording from Denmark. Devices that use magne ...
, however unit record devices, such as punch card readers, card punches, line printers and page printers can provide input/output (I/O) for a data set (file). Data sets are not unstructured streams of bytes, but rather are organized in various logical record and block structures determined by the DSORG (data set organization), RECFM (record format), and other parameters. These parameters are specified at the time of the data set allocation (creation), for example with Job Control Language DD statements. Within a running program they are stored in the Data Control Block (DCB) or Access Control Block (ACB), which are data structures used to access data sets using
access method An access method is a function of a mainframe operating system that enables access to data on disk, tape or other external devices. Access methods were present in several mainframe operating systems since the late 1950s, under a variety of nam ...
s. Records in a data set may be fixed, variable, or “undefined” length.


Data set organization

For OS/360, the DCB's DSORG parameter specifies how the data set is organized. It may be ;CQ : Queued Telecommunications Access Method (QTAM) in Message Control Program (MCP) ;CX :Communications line group ;DA : Basic Direct Access Method (BDAM) ;GS :Graphics device for Graphics Access Method(GAM) ;IS : Indexed Sequential Access Method (ISAM) ;MQ :QTAM message queue in application ;PO :Partitioned ;PS :Physical Sequential among others. Data sets on tape may only be DSORG=PS. The choice of organization depends on how the data is to be accessed, and in particular, how it is to be updated. Programmers utilize various
access method An access method is a function of a mainframe operating system that enables access to data on disk, tape or other external devices. Access methods were present in several mainframe operating systems since the late 1950s, under a variety of nam ...
s (such as QSAM or VSAM) in programs for reading and writing data sets. Access method depends on the given data set organization.


Record format (RECFM)

Regardless of organization, the physical structure of each record is essentially the same, and is uniform throughout the data set. This is specified in the DCB RECFM parameter. RECFM=F means that the records are of fixed length, specified via the LRECL parameter. RECFM=V specifies a variable-length record. V records when stored on media are prefixed by a Record Descriptor Word (RDW) containing the integer length of the record in bytes and flag bits. With RECFM=FB and RECFM=VB, multiple logical records are grouped together into a single physical block on tape or DASD. FB and VB are fixed-blocked, and variable-blocked, respectively. RECFM=U (undefined) is also variable length, but the length of the record is determined by the length of the block rather than by a control field. The BLKSIZE parameter specifies the maximum length of the block. RECFM=FBS could be also specified, meaning fixed-blocked standard, meaning all the blocks except the last one were required to be in full BLKSIZE length. RECFM=VBS, or variable-blocked spanned, means a logical record could be spanned across two or more blocks, with flags in the RDW indicating whether a record segment is continued into the next block and/or was continued from the previous one. This mechanism eliminates the need for using any "delimiter" byte value to separate records. Thus data can be of any type, including binary integers, floating-point, or characters, without introducing a false end-of-record condition. The data set is an abstraction of a collection of records, in contrast to files as unstructured streams of bytes.


Partitioned data set

A partitioned data set (PDS) is a data set containing multiple ''members'', each of which holds a separate sub-data set, similar to a directory in other types of
file system In computing, file system or filesystem (often abbreviated to fs) is a method and data structure that the operating system uses to control how data is stored and retrieved. Without a file system, data placed in a storage medium would be one larg ...
s. This type of data set is often used to hold ''load modules'' (old format bound executable programs), source program libraries (especially Assembler macro definitions), ISPF screen definitions, and Job Control Language. A PDS may be compared to a
Zip Zip, Zips or ZIP may refer to: Common uses * ZIP Code, USPS postal code * Zipper or zip, clothing fastener Science and technology Computing * ZIP (file format), a compressed archive file format ** zip, a command-line program from Info-ZIP * Zi ...
file or COM Structured Storage. A Partitioned Data Set can only be allocated on a single volume and have a maximum size of 65,535 tracks. Besides members, a PDS contains also a directory. Each member can be accessed indirectly via the directory structure. Once a member is located, the data stored in that member are handled in the same manner as a PS (sequential) data set. Whenever a member is deleted, the space it occupied is unusable for storing other data. Likewise, if a member is re-written, it is stored in a new spot at the back of the PDS and leaves wasted “dead” space in the middle. The only way to recover “dead” space is to perform file compression. Compression, which is done using the IEBCOPY utility, moves all members to the front of the data space and leaves free usable space at the back. (Note that in modern parlance, this kind of operation might be called defragmentation or garbage collection; data compression nowadays refers to a different, more complicated concept.) PDS files can only reside on DASD, not on
magnetic tape Magnetic tape is a medium for magnetic storage made of a thin, magnetizable coating on a long, narrow strip of plastic film. It was developed in Germany in 1928, based on the earlier magnetic wire recording from Denmark. Devices that use magne ...
, in order to use the directory structure to access individual members. Partitioned data sets are most often used for storing multiple job control language files, utility control statements, and executable modules. An improvement of this scheme is a Partitioned Data Set Extended (PDSE or PDS/E, sometimes just ''libraries'') introduced with DFSMSdfp for MVS/XA and MVS/ESA systems. A PDS/E library can store program objects or other types of members, but not both. BPAM cannot process a PDS/E containing program objects. PDS/E structure is similar to PDS and is used to store the same types of data. However, PDS/E files have a better directory structure which does not require pre-allocation of directory blocks when the PDS/E is defined (and therefore does not run out of directory blocks if not enough were specified). Also, PDS/E automatically stores members in such a way that compression operation is not needed to reclaim "dead" space. PDS/E files can only reside on DASD in order to use the directory structure to access individual members.


Generation Data Group

A Generation Data Group (''GDG'') is a group of non-VSAM data sets that are successive generations of historically-related data stored on an IBM mainframe (running OS or
DOS/VSE VSEn (''Virtual Storage Extended'') is an operating system for IBM mainframe computers, the latest one in the DOS/360 lineage, which originated in 1965. DOS/VSE was introduced in 1979 as a successor to DOS/VS; in turn, DOS/VSE was succeeded by ...
). A GDG is usually cataloged. An individual member of the GDG collection is called a "''Generation Data Set''." The latter may be identified by an absolute number, , or a relative number: (-1) for the previous generation, (0) for the current one, and (+1) the next generation.


GDG JCL & features

Generation Data Groups are defined using either the BLDG statement of the IEHPROGM utility or the DEFINE GENERATIONGROUP statement of the newer