Coulometric
   HOME

TheInfoList



OR:

Coulometry determines the amount of matter transformed during an
electrolysis In chemistry and manufacturing, electrolysis is a technique that uses direct electric current (DC) to drive an otherwise non-spontaneous chemical reaction. Electrolysis is commercially important as a stage in the separation of elements from n ...
reaction by measuring the amount of
electricity Electricity is the set of physical phenomena associated with the presence and motion of matter that has a property of electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described ...
(in
coulomb The coulomb (symbol: C) is the unit of electric charge in the International System of Units (SI). In the present version of the SI it is equal to the electric charge delivered by a 1 ampere constant current in 1 second and to elementary char ...
s) consumed or produced. It can be used for precision measurements of charge, and the
ampere The ampere (, ; symbol: A), often shortened to amp,SI supports only the use of symbols and deprecates the use of abbreviations for units. is the unit of electric current in the International System of Units (SI). One ampere is equal to elect ...
s even used to have a coulometric definition. However, today coulometry is mainly used for analytical applications. Coulometry is a group of techniques in analytical chemistry. It is named after Charles-Augustin de Coulomb. There are two basic categories of coulometric techniques. ''Potentiostatic coulometry'' involves holding the
electric potential The electric potential (also called the ''electric field potential'', potential drop, the electrostatic potential) is defined as the amount of work energy needed to move a unit of electric charge from a reference point to the specific point in ...
constant during the reaction using a potentiostat. The other, called ''coulometric titration'' or ''amperostatic coulometry'', keeps the current (measured in amperes) constant using an
amperostat A galvanostat (also known as amperostat) is a control and measuring device capable of keeping the current through an electrolytic cell in coulometric titrations constant, disregarding changes in the load itself. Its main feature is its ''nearly' ...
.


Potentiostatic coulometry

Potentiostatic coulometry is a technique most commonly referred to as "
bulk electrolysis Bulk electrolysis is also known as ''potentiostatic coulometry'' or ''controlled potential coulometry''. The experiment is a form of coulometry which generally employs a three electrode system controlled by a potentiostat. In the experiment the ...
". The working electrode is kept at a constant potential and the current that flows through the circuit is measured. This constant potential is applied long enough to fully reduce or oxidize all of the electroactive species in a given solution. As the electroactive molecules are consumed, the current also decreases, approaching zero when the conversion is complete. The sample mass, molecular mass, number of electrons in the electrode reaction, and number of electrons passed during the experiment are all related by Faraday's laws. It follows that, if three of the values are known, then the fourth can be calculated. Bulk electrolysis is often used to unambiguously assign the number of electrons consumed in a reaction observed through voltammetry. It also has the added benefit of producing a solution of a species (oxidation state) which may not be accessible through chemical routes. This species can then be isolated or further characterized while in solution. The rate of such reactions is not determined by the concentration of the solution, but rather the mass transfer of the electroactive species in the solution to the electrode surface. Rates will increase when the volume of the solution is decreased, the solution is stirred more rapidly, or the area of the working electrode is increased. Since mass transfer is so important the solution is stirred during a bulk electrolysis. However, this technique is generally not considered a
hydrodynamic technique Hydrodynamic voltammetry is a form of voltammetry in which the analyte solution flows relative to a working electrode. In many voltammetry techniques, the solution is intentionally left still to allow diffusion controlled mass transfer. When a solu ...
, since a laminar flow of solution against the electrode is neither the objective nor outcome of the stirring. The extent to which a reaction goes to completion is also related to how much greater the applied potential is than the reduction potential of interest. In the case where multiple reduction potentials are of interest, it is often difficult to set an electrolysis potential a "safe" distance (such as 200 mV) past a redox event. The result is incomplete conversion of the substrate, or else conversion of some of the substrate to the more reduced form. This factor must be considered when analyzing the current passed and when attempting to do further analysis/isolation/experiments with the substrate solution. An advantage to this kind of analysis over electrogravimetry is that it does not require that the product of the reaction be weighed. This is useful for reactions where the product does not deposit as a solid, such as the determination of the amount of
arsenic Arsenic is a chemical element with the symbol As and atomic number 33. Arsenic occurs in many minerals, usually in combination with sulfur and metals, but also as a pure elemental crystal. Arsenic is a metalloid. It has various allotropes, but ...
in a sample from the electrolysis of
arsenous acid Arsenous acid (or arsenious acid) is the inorganic compound with the formula H3AsO3. It is known to occur in aqueous solutions, but it has not been isolated as a pure material, although this fact does not detract from the significance of As(OH)3. ...
( H3AsO3) to
arsenic acid Arsenic acid or trihydrogen arsenate is the chemical compound with the formula . More descriptively written as , this colorless acid is the arsenic analogue of phosphoric acid. Arsenate and phosphate salts behave very similarly. Arsenic acid as ...
( H3AsO4).


Coulometric titration

Coulometric titrations use a constant current system to accurately quantify the concentration of a species. In this experiment, the applied current is equivalent to a
titrant Titration (also known as titrimetry and volumetric analysis) is a common laboratory method of Quantitative research, quantitative Analytical chemistry, chemical analysis to determine the concentration of an identified analyte (a substance to be ...
. Current is applied to the unknown solution until all of the unknown species is either oxidized or reduced to a new state, at which point the potential of the working electrode shifts dramatically. This potential shift indicates the endpoint. The magnitude of the current (in
ampere The ampere (, ; symbol: A), often shortened to amp,SI supports only the use of symbols and deprecates the use of abbreviations for units. is the unit of electric current in the International System of Units (SI). One ampere is equal to elect ...
s) and the duration of the current (
second The second (symbol: s) is the unit of time in the International System of Units (SI), historically defined as of a day – this factor derived from the division of the day first into 24 hours, then to 60 minutes and finally to 60 seconds ...
s) can be used to determine the
mole Mole (or Molé) may refer to: Animals * Mole (animal) or "true mole", mammals in the family Talpidae, found in Eurasia and North America * Golden moles, southern African mammals in the family Chrysochloridae, similar to but unrelated to Talpida ...
s of the unknown species in solution. When the volume of the solution is known, then the molarity of the unknown species can be determined. Advantages of Coulometric Titration Coulometric titration has the advantage that constant current sources for the generation of titrants are relatively easy to make. * The electrochemical generation of a titrant is much more sensitive and can be much more accurately controlled than the mechanical addition of titrant using a burette drive. For example, a constant current flow of 10 µA for 100ms is easily generated and corresponds to about 10 micrograms of titrant. * The preparation of standard solutions and titer determination is of course no longer necessary. * Chemical substances that are unstable or difficult to handle because of their high volatility or reactivity in solution can also very easily be used as titrants. Examples are bromine, chlorine, Ti3+, Sn2+, Cr2+, and Karl Fischer reagents (iodine). * Coulometric titration can also be performed under inert atmosphere or be remotely controlled e.g. with radioactive substances.


Applications


Karl Fischer reaction

The Karl Fischer reaction uses a coulometric titration to determine the amount of water in a sample. It can determine concentrations of water on the order of milligrams per liter. It is used to find the amount of water in substances such as
butter Butter is a dairy product made from the fat and protein components of churned cream. It is a semi-solid emulsion at room temperature, consisting of approximately 80% butterfat. It is used at room temperature as a spread, melted as a condiment ...
,
sugar Sugar is the generic name for sweet-tasting, soluble carbohydrates, many of which are used in food. Simple sugars, also called monosaccharides, include glucose, fructose, and galactose. Compound sugars, also called disaccharides or double ...
,
cheese Cheese is a dairy product produced in wide ranges of flavors, textures, and forms by coagulation of the milk protein casein. It comprises proteins and fat from milk, usually the milk of cows, buffalo, goats, or sheep. During production, ...
,
paper Paper is a thin sheet material produced by mechanically or chemically processing cellulose fibres derived from wood, rags, grasses or other vegetable sources in water, draining the water through fine mesh leaving the fibre evenly distributed ...
, and
petroleum Petroleum, also known as crude oil, or simply oil, is a naturally occurring yellowish-black liquid mixture of mainly hydrocarbons, and is found in geological formations. The name ''petroleum'' covers both naturally occurring unprocessed crud ...
. The reaction involves converting solid iodine into hydrogen iodide in the presence of sulfur dioxide and water.
Methanol Methanol (also called methyl alcohol and wood spirit, amongst other names) is an organic chemical and the simplest aliphatic alcohol, with the formula C H3 O H (a methyl group linked to a hydroxyl group, often abbreviated as MeOH). It is a ...
is most often used as the solvent, but
ethylene glycol Ethylene glycol (IUPAC name: ethane-1,2-diol) is an organic compound (a vicinal diol) with the formula . It is mainly used for two purposes, as a raw material in the manufacture of polyester fibers and for antifreeze formulations. It is an odo ...
and diethylene glycol also work.
Pyridine Pyridine is a basic heterocyclic organic compound with the chemical formula . It is structurally related to benzene, with one methine group replaced by a nitrogen atom. It is a highly flammable, weakly alkaline, water-miscible liquid with a d ...
is often used to prevent the buildup of
sulfuric acid Sulfuric acid (American spelling and the preferred IUPAC name) or sulphuric acid ( Commonwealth spelling), known in antiquity as oil of vitriol, is a mineral acid composed of the elements sulfur, oxygen and hydrogen, with the molecular formu ...
, although the use of
imidazole Imidazole (ImH) is an organic compound with the formula C3N2H4. It is a white or colourless solid that is soluble in water, producing a mildly alkaline solution. In chemistry, it is an aromatic heterocycle, classified as a diazole Diazole refers ...
and
diethanolamine Diethanolamine, often abbreviated as DEA or DEOA, is an organic compound with the formula HN(CH2CH2OH)2. Pure diethanolamine is a white solid at room temperature, but its tendencies to absorb water and to supercool meaning that it is often encou ...
for this role are becoming more common. All reagents must be
anhydrous A substance is anhydrous if it contains no water. Many processes in chemistry can be impeded by the presence of water; therefore, it is important that water-free reagents and techniques are used. In practice, however, it is very difficult to achie ...
for the analysis to be quantitative. The balanced chemical equation, using methanol and pyridine, is: : \mathrm \longrightarrow \mathrm In this reaction, a single molecule of water reacts with a molecule of iodine. Since this technique is used to determine the water content of samples, atmospheric humidity could alter the results. Therefore, the system is usually isolated with drying tubes or placed in an
inert gas An inert gas is a gas that does not readily undergo chemical reactions with other chemical substances and therefore does not readily form chemical compounds. The noble gases often do not react with many substances and were historically referred to ...
container. In addition, the solvent will undoubtedly have some water in it so the solvent’s water content must be measured to compensate for this inaccuracy. To determine the amount of water in the sample, analysis must first be performed using either back or direct titration. In the direct method, just enough of the reagents will be added to completely use up all of the water. At this point in the titration, the current approaches zero. It is then possible to relate the amount of reagents used to the amount of water in the system via
stoichiometry Stoichiometry refers to the relationship between the quantities of reactants and products before, during, and following chemical reactions. Stoichiometry is founded on the law of conservation of mass where the total mass of the reactants equal ...
. The back-titration method is similar, but involves the addition of an excess of the reagent. This excess is then consumed by adding a known amount of a standard solution with known water content. The result reflects the water content of the sample and the standard solution. Since the amount of water in the standard solution is known, the difference reflects the water content of the sample.


Determination of film thickness

Coulometry can be used in the determination of the thickness of metallic coatings. This is performed by measuring the
quantity of electricity The word ''electricity'' derives from New Latin and ultimately Greek. It first appears in English in Francis Bacon's writings. Depending on context, the word may refer to "electric charge", "electric power" or "electric energy". Historical drift ...
needed to dissolve a well-defined area of the coating. The film thickness \Delta is proportional to the constant current i, the
molecular weight A molecule is a group of two or more atoms held together by attractive forces known as chemical bonds; depending on context, the term may or may not include ions which satisfy this criterion. In quantum physics, organic chemistry, and bioch ...
M of the metal, the
density Density (volumetric mass density or specific mass) is the substance's mass per unit of volume. The symbol most often used for density is ''ρ'' (the lower case Greek letter rho), although the Latin letter ''D'' can also be used. Mathematical ...
\rho of the metal, and the surface area A: \triangle \propto \frac The electrodes for this reaction are often platinum electrode and an electrode that relates to the reaction. For tin coating on a copper wire, a tin electrode is used, while a sodium chloride-zinc sulfate electrode would be used to determine the zinc film on a piece of steel. Special cells have been created to adhere to the surface of the metal to measure its thickness. These are basically columns with the internal electrodes with magnets or weights to attach to the surface. The results obtained by this coulometric method are similar to those achieved by other chemical and metallurgic techniques.


Coulometers


Electronic coulometer

The electronic coulometer is based on the application of the operational amplifier in the "integrator"-type circuit. The current passed through the resistor R1 makes a potential drop which is integrated by operational amplifier on the
capacitor A capacitor is a device that stores electrical energy in an electric field by virtue of accumulating electric charges on two close surfaces insulated from each other. It is a passive electronic component with two terminals. The effect of ...
plates; the higher current, the larger the potential drop. The current need not be constant. In such scheme ''V''out is proportional of the passed charge. Sensitivity of the coulometer can be changed by choosing of the appropriate value of ''R''1.


Electrochemical coulometers

There are three common types of coulometers based on electrochemical processes: * Copper coulometer * Mercury coulometer *
Hofmann voltameter A Hofmann voltameter is an apparatus for electrolysing water, invented by August Wilhelm von Hofmann (1818–1892) in 1866. It consists of three joined upright cylinders, usually glass. The inner cylinder is open at the top to allow addition of ...
"Voltameter" is a synonym for "coulometer".


References


Bibliography

*


External links


IUPAC Gold Book: coulometric detection methodCoulometry at the University of Akron
{{Electroanalytical Electroanalytical methods