Building automation (BAS), also known as building management system (BMS) or building energy management system (BEMS), is the automatic centralized control of a building's HVAC (heating, ventilation and air conditioning), electrical,
lighting Lighting or illumination is the deliberate use of light to achieve practical or aesthetic effects. Lighting includes the use of both artificial light sources like lamps and light fixtures, as well as natural illumination by capturing daylig ...
, shading,
Access Control In the fields of physical security and information security, access control (AC) is the selective restriction of access to a place or other resource, while access management describes the process. The act of ''accessing'' may mean consuming ...
, Security Systems, and other interrelated systems. Some objectives of building automation are improved occupant comfort, efficient operation of building systems, reduction in energy consumption, reduced operating and maintaining costs and increased security. BAS functionality may keep a buildings climate within a specified range, provide light to rooms based on an occupancy, monitor performance and device failures, and provide malfunction alarms to building maintenance staff. A BAS works to reduce building energy and maintenance costs compared to a non-controlled building. Most commercial, institutional, and industrial buildings built after 2000 include a BAS, whilst older buildings may be retrofitted with a new BAS. A building controlled by a BAS is often referred to as an intelligent building, "smart building," or (if a residence) a " smart home." Commercial and industrial buildings have historically relied on robust proven protocols (like
BACnet BACnet is a communication protocol for building automation and control (BAC) networks that use the ASHRAE, ANSI, and ISO 16484-5 standards protocol. BACnet was designed to allow communication of building automation and control systems for applic ...
) while proprietary protocols (like X-10) were used in homes. Almost all multi-story green buildings are designed to accommodate a BAS for the energy, air and water conservation characteristics. Electrical device
demand response Demand response is a change in the power consumption of an electric utility customer to better match the demand for power with the supply. Until the 21st century decrease in the cost of pumped storage and batteries electric energy could not be ...
is a typical function of a BAS, as is the more sophisticated ventilation and humidity monitoring required of "tight" insulated buildings. Most green buildings also use as many low-power DC devices as possible. Even a
passivhaus "Passive house" (german: Passivhaus) is a voluntary standard for energy efficiency in a building, which reduces the building's ecological footprint. It results in ultra-low energy buildings that require little energy for space heating or coo ...
design intended to consume no net energy whatsoever will typically require a BAS to manage
heat capture In thermodynamics, heat is defined as the form of energy crossing the boundary of a thermodynamic system by virtue of a temperature difference across the boundary. A thermodynamic system does not ''contain'' heat. Nevertheless, the term is al ...
, shading and venting, and scheduling device use.


Characteristics

Building management systems are most commonly implemented in large projects with extensive mechanical, HVAC, and electrical systems. Systems linked to a BMS typically represent 40% of a building's energy usage; if lighting is included, this number approaches to 70%. BMS systems are a critical component to managing energy demand. Improperly configured BMS systems are believed to account for 20% of building energy usage, or approximately 8% of total energy usage in the United States. In addition to controlling the building's internal environment, BMS systems are sometimes linked to access control (turnstiles and access doors controlling who is allowed access and egress to the building) or other security systems such as
closed-circuit television Closed-circuit television (CCTV), also known as video surveillance, is the use of video cameras to transmit a signal to a specific place, on a limited set of monitors. It differs from broadcast television in that the signal is not openly t ...
(CCTV) and motion detectors. Fire alarm systems and elevators are also sometimes linked to a BMS for monitoring. In case a fire is detected then only the fire alarm panel could close dampers in the ventilation system to stop smoke spreading, shut down air handlers, start smoke evacuation fans, and send all the elevators to the ground floor and park them to prevent people from using them. Building management systems have also included disaster-response mechanisms (such as
base isolation Seismic base isolation, also known as base isolation, or base isolation system, is one of the most popular means of protecting a structure against earthquake forces. It is a collection of structural elements which should substantially decoup ...
) to save structures from earthquakes. In more recent times, companies and governments have been working to find similar solutions for flood zones and coastal areas at-risk to
rising sea levels Rising may refer to: * Rising, a stage in baking - see Proofing (baking technique) *Elevation * Short for Uprising, a rebellion Film and TV * "Rising" (''Stargate Atlantis''), the series premiere of the science fiction television program ''Starga ...
. Self-adjusting floating environment draws from existing technologies used to float concrete bridges and runways such as Washington's SR 520 and Japan's Mega-Float.


Types of inputs and outputs


Sensors

Analog inputs are used to read a variable measurement. Examples are
temperature Temperature is a physical quantity that expresses quantitatively the perceptions of hotness and coldness. Temperature is measured with a thermometer. Thermometers are calibrated in various temperature scales that historically have relied o ...
,
humidity Humidity is the concentration of water vapor present in the air. Water vapor, the gaseous state of water, is generally invisible to the human eye. Humidity indicates the likelihood for precipitation, dew, or fog to be present. Humidity depe ...
and
pressure sensors A pressure sensor is a device for pressure measurement of gases or liquids. Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area. A pressure sensor usually act ...
which could be
thermistor A thermistor is a type of resistor whose resistance is strongly dependent on temperature, more so than in standard resistors. The word thermistor is a portmanteau of ''thermal'' and ''resistor''. Thermistors are divided based on their conduction ...
, 4–20 mA, 0–10
volt The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). It is named after the Italian physicist Alessandro Volta (1745–1827). Defi ...
or platinum resistance thermometer (resistance temperature detector), or wireless
sensor A sensor is a device that produces an output signal for the purpose of sensing a physical phenomenon. In the broadest definition, a sensor is a device, module, machine, or subsystem that detects events or changes in its environment and sends ...
s. A digital input indicates a device is on or off. Some examples of digital inputs would be a door contact switch, a current switch, an air flow switch, or a voltage-free
relay A relay Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off A relay is an electrically operated switch ...
contact (dry contact). Digital inputs could also be pulse inputs counting the pulses over a period of time. An example is a turbine flow meter transmitting flow data as a frequency of pulses to an input.
Nonintrusive load monitoring Nonintrusive load monitoring (NILM), or nonintrusive appliance load monitoring (NIALM), is a process for analyzing changes in the voltage and current going into a house and deducing what appliances are used in the house as well as their individual e ...
is software relying on digital sensors and algorithms to discover appliance or other loads from electrical or magnetic characteristics of the circuit. It is however detecting the event by an analog means. These are extremely cost-effective in operation and useful not only for identification but to detect
start-up transient A startup or start-up is a company or project undertaken by an entrepreneur to seek, develop, and validate a scalable business model. While entrepreneurship refers to all new businesses, including self-employment and businesses that never intend t ...
s, line or equipment faults, etc.


Controls

Analog outputs control the speed or position of a device, such as a variable frequency drive, an I-P ( current to
pneumatics Pneumatics (from Greek ‘wind, breath’) is a branch of engineering that makes use of gas or pressurized air. Pneumatic systems used in industry are commonly powered by compressed air or compressed inert gases. A centrally located and elec ...
)
transducer A transducer is a device that converts energy from one form to another. Usually a transducer converts a signal in one form of energy to a signal in another. Transducers are often employed at the boundaries of automation, measurement, and contr ...
, or a valve or damper
actuator An actuator is a component of a machine that is responsible for moving and controlling a mechanism or system, for example by opening a valve. In simple terms, it is a "mover". An actuator requires a control device (controlled by control signal) a ...
. An example is a hot water valve opening up 25% to maintain a setpoint. Another example is a variable frequency drive ramping up a motor slowly to avoid a hard start. Digital outputs are used to open and close relays and switches as well as drive a load upon command. An example would be to turn on the parking lot lights when a photocell indicates it is dark outside. Another example would be to open a valve by allowing 24VDC/AC to pass through the output powering the valve. Analog outputs could also be pulse type outputs emitting a frequency of pulses over a given period of time. An example is an energy meter calculating kWh and emitting a frequency of pulses accordingly.


Infrastructure


Controller

Controllers are essentially small, purpose-built computers with input and output capabilities. These controllers come in a range of sizes and capabilities to control devices commonly found in buildings, and to control sub-networks of controllers. Inputs allow a controller to read temperature, humidity, pressure, current flow, air flow, and other essential factors. The outputs allow the controller to send command and control signals to slave devices, and to other parts of the system. Inputs and outputs can be either digital or analog. Digital outputs are also sometimes called discrete depending on manufacturer. Controllers used for building automation can be grouped in three categories: programmable logic controllers (PLCs), system/network controllers, and terminal unit controllers. However an additional device can also exist in order to integrate third-party systems (e.g. a stand-alone AC system) into a central building automation system. Terminal unit controllers usually are suited for control of lighting and/or simpler devices such as a package rooftop unit, heat pump, VAV box, fan coil, etc. The installer typically selects one of the available pre-programmed personalities best suited to the device to be controlled, and does not have to create new control logic.


Occupancy

Occupancy is one of two or more operating modes for a building automation system; Unoccupied, Morning Warmup, and Night-time Setback are other common modes. Occupancy is usually based on time of day schedules. In Occupancy mode, the BAS aims to provides a comfortable climate and adequate lighting, often with zone-based control so that users on one side of a building have a different thermostat (or a different system, or sub system) than users on the opposite side. A temperature sensor in the zone provides feedback to the controller, so it can deliver heating or cooling as needed. If enabled, morning warmup (MWU) mode occurs prior to occupancy. During Morning Warmup the BAS tries to bring the building to setpoint just in time for Occupancy. The BAS often factors in outdoor conditions and historical experience to optimize MWU. This is also referred to as ''optimized start''. Some buildings rely on
occupancy sensor An occupancy sensor is an indoor motion detecting device used to detect the presence of a person to automatically control lights or temperature or ventilation systems. The sensors use infrared, ultrasonic, microwave, or other technology. The ter ...
s to activate lighting or climate conditioning. Given the potential for long lead times before a space becomes sufficiently cool or warm, climate conditioning is not often initiated directly by an occupancy sensor.


Lighting

Lighting Lighting or illumination is the deliberate use of light to achieve practical or aesthetic effects. Lighting includes the use of both artificial light sources like lamps and light fixtures, as well as natural illumination by capturing daylig ...
can be turned on, off, or dimmed with a building automation or
lighting control system A lighting control system is an intelligent network based lighting control solution that incorporates communication between various system inputs and outputs related to lighting control with the use of one or more central computing devices. Light ...
based on time of day, or on occupancy sensor, photosensors and timers. One typical example is to turn the lights in a space on for a half-hour since the last motion was sensed. A photocell placed outside a building can sense darkness, and the time of day, and modulate lights in outer offices and the parking lot. Lighting is also a good candidate for
demand response Demand response is a change in the power consumption of an electric utility customer to better match the demand for power with the supply. Until the 21st century decrease in the cost of pumped storage and batteries electric energy could not be ...
, with many control systems providing the ability to dim (or turn off) lights to take advantage of DR incentives and savings. In newer buildings, the lighting control can be based on the
field bus Fieldbus is the name of a family of industrial computer networks used for real-time distributed control. Fieldbus profiles are standardized by the International Electrotechnical Commission (IEC) as IEC 61784/61158. A complex automated industrial ...
Digital Addressable Lighting Interface Digital Addressable Lighting Interface (DALI) is a trademark for network-based products that control lighting. The underlying technology was established by a consortium of lighting equipment manufacturers as a successor for 1-10 V/ lighting ...
(DALI). Lamps with DALI ballasts are fully dimmable. DALI can also detect lamp and ballast failures on DALI luminaires and signals failures.


Shading and glazing

Shading and glazing are essential components in the building system, they affect occupants’ visual, acoustical, and thermal comfort and provide the occupant with a view outdoor. Automated shading and glazing systems are solutions for controlling solar heat gains and glare. It refers to the use of technology to control external or internal shading devices (such as blinds, and shades) or glazing itself. The system has an active and rapid response to various changing outdoor data (such as solar, wind) and to changing interior environment (such as temperature, illuminance, and occupant demands). Building shading and glazing systems can contribute to thermal and lighting improvement from both energy conservation and comfort point of view.


Dynamic shading

Dynamic shading devices allow the control of daylight and solar energy to enter into built environment in relation to outdoor conditions, daylighting demands and solar positions. The common products include venetian blinds, roller shades,
louver A louver (American English) or louvre (British English British English (BrE, en-GB, or BE) is, according to Lexico, Oxford Dictionaries, "English language, English as used in Great Britain, as distinct from that used elsewhere". Mor ...
s, and shutters. They are mostly installed on the interior side of the glazing system because of the low maintenance cost, but also can be used on the exterior or a combination of both.


Air Handlers

Most
air handler An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blowe ...
s mix return and outside air so less temperature/humidity conditioning is needed. This can save money by using less chilled or heated water (not all AHUs use chilled or hot water circuits). Some external air is needed to keep the building's air healthy. To optimize energy efficiency while maintaining healthy indoor air quality (IAQ), demand control (or controlled) ventilation (DCV) adjusts the amount of outside air based on measured levels of occupancy. Analog or digital temperature sensors may be placed in the space or room, the return and supply
air duct Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The needed airflows include, for example, ''supply air'', ''return air'', and ''exhaust air''. Ducts commonly also deliver '' ...
s, and sometimes the external air. Actuators are placed on the hot and chilled water valves, the outside air and return air dampers. The supply fan (and return if applicable) is started and stopped based on either time of day, temperatures, building pressures or a combination.


Alarms and Security

All modern building automation systems have alarm capabilities. It does little good to detect a potentially hazardous or costly situation if no one who can solve the problem is notified. Notification can be through a computer (email or text message), pager, cellular phone voice call, audible alarm, or all of these. For insurance and liability purposes all systems keep logs of who was notified, when and how. Alarms may immediately notify someone or only notify when alarms build to some threshold of seriousness or urgency. At sites with several buildings, momentary power failures can cause hundreds or thousands of alarms from equipment that has shut down – these should be suppressed and recognized as symptoms of a larger failure. Some sites are programmed so that critical alarms are automatically re-sent at varying intervals. For example, a repeating critical alarm (of an
uninterruptible power supply An uninterruptible power supply or uninterruptible power source (UPS) is an electrical apparatus that provides emergency power to a load when the input power source or mains power fails. A UPS differs from an auxiliary or emergency power system ...
in 'bypass') might resound at 10 minutes, 30 minutes, and every 2 to 4 hours thereafter until the alarms are resolved. Security systems can be interlocked to a building automation system. If occupancy sensors are present, they can also be used as burglar alarms. Because security systems are often deliberately sabotaged, at least some detectors or cameras should have battery backup and wireless connectivity and the ability to trigger alarms when disconnected. Modern systems typically use power-over-Ethernet (which can operate a pan-tilt-zoom camera and other devices up to 30–90 watts) which is capable of charging such batteries and keeps wireless networks free for genuinely wireless applications, such as backup communication in outage.
Fire alarm panel A fire alarm control panel (FACP), fire alarm control unit (FACU), fire indicator panel (FIP), or simply fire alarm panel is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and rep ...
s and their related smoke alarm systems are usually hard-wired to override building automation. For example: if the smoke alarm is activated, all the outside air dampers close to prevent air coming into the building, and an exhaust system can isolate the blaze. Similarly,
electrical fault detection Electricity is the set of physical phenomena associated with the presence and motion of matter that has a property of electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described by ...
systems can turn entire circuits off, regardless of the number of alarms this triggers or persons this distresses.
Fossil fuel A fossil fuel is a hydrocarbon-containing material formed naturally in the Earth's crust from the remains of dead plants and animals that is extracted and burned as a fuel. The main fossil fuels are coal, oil, and natural gas. Fossil fuels m ...
combustion devices also tend to have their own over-rides, such as
natural gas Natural gas (also called fossil gas or simply gas) is a naturally occurring mixture of gaseous hydrocarbons consisting primarily of methane in addition to various smaller amounts of other higher alkanes. Low levels of trace gases like carbo ...
feed lines that turn off when slow pressure drops are detected (indicating a leak), or when excess
methane Methane ( , ) is a chemical compound with the chemical formula (one carbon atom bonded to four hydrogen atoms). It is a group-14 hydride, the simplest alkane, and the main constituent of natural gas. The relative abundance of methane on Eart ...
is detected in the building's air supply.


Buses and protocols

Most building automation networks consist of a ''primary'' and ''secondary'' bus which connect high-level controllers (generally specialized for building automation, but may be generic
programmable logic controller A programmable logic controller (PLC) or programmable controller is an industrial computer that has been ruggedized and adapted for the control of manufacturing processes, such as assembly lines, machines, robotic devices, or any activity tha ...
s) with lower-level controllers,
input/output In computing, input/output (I/O, or informally io or IO) is the communication between an information processing system, such as a computer, and the outside world, possibly a human or another information processing system. Inputs are the signals ...
devices and a
user interface In the industrial design field of human–computer interaction, a user interface (UI) is the space where interactions between humans and machines occur. The goal of this interaction is to allow effective operation and control of the machine f ...
(also known as a human interface device).
ASHRAE The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE ) is an American professional association seeking to advance heating, ventilation, air conditioning and refrigeration (HVAC&R) systems design and constructio ...
's open protocol
BACnet BACnet is a communication protocol for building automation and control (BAC) networks that use the ASHRAE, ANSI, and ISO 16484-5 standards protocol. BACnet was designed to allow communication of building automation and control systems for applic ...
or the open protocol
LonTalk LonTalk is a protocol optimized for control. Originally developed by Echelon Corporation for networking devices over media such as twisted pair, powerlines, fiber optics, and RF. It is popular for the automation of various functions in industri ...
specify how most such devices interoperate. Modern systems use
SNMP Simple Network Management Protocol (SNMP) is an Internet Standard protocol for collecting and organizing information about managed devices on IP networks and for modifying that information to change device behaviour. Devices that typically ...
to track events, building on decades of history with SNMP-based protocols in the computer networking world. Physical connectivity between devices was historically provided by dedicated
optical fiber An optical fiber, or optical fibre in Commonwealth English, is a flexible, transparent fiber made by drawing glass (silica) or plastic to a diameter slightly thicker than that of a human hair. Optical fibers are used most often as a means to ...
,
ethernet Ethernet () is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 198 ...
, ARCNET,
RS-232 In telecommunications, RS-232 or Recommended Standard 232 is a standard originally introduced in 1960 for serial communication transmission of data. It formally defines signals connecting between a ''DTE'' (''data terminal equipment'') such a ...
, RS-485 or a low-bandwidth special purpose
wireless network A wireless network is a computer network that uses wireless data connections between network nodes. Wireless networking is a method by which homes, telecommunications networks and business installations avoid the costly process of introducing c ...
. Modern systems rely on standards-based multi-protocol heterogeneous networking such as that specified in the
IEEE 1905.1 IEEE 1905.1 is an IEEE standard which defines a network enabler for home networking supporting both wireless and wireline technologies: IEEE 802.11 (marketed under the Wi-Fi trademark), IEEE 1901 (HomePlug, HD-PLC) powerline networking, IEEE 802 ...
standard and verified by the nVoy auditing mark. These accommodate typically only IP-based networking but can make use of any existing wiring, and also integrate
powerline networking Power-line communication (also known as power-line carrier or PLC) carries data on a conductor that is also used simultaneously for AC electric power transmission or electric power distribution to consumers. A wide range of power-line communicati ...
over AC circuits,
power over Ethernet Power over Ethernet, or PoE, describes any of several standards or ad hoc systems that pass electric power along with data on twisted-pair Ethernet cabling. This allows a single cable to provide both data connection and electrical power to d ...
low-power DC circuits, high-bandwidth wireless networks such as
LTE LTE may refer to: Science and technology * LTE (telecommunication) (Long-Term Evolution), a telephone and mobile broadband standard ** LTE Advanced, an enhancement *** LTE Advanced Pro * Compaq LTE, a line of laptop computers produced by Compaq * ...
and
IEEE 802.11n IEEE 802.11n-2009 or 802.11n is a wireless-networking standard that uses multiple antennas to increase data rates. The Wi-Fi Alliance has also retroactively labelled the technology for the standard as Wi-Fi 4. It standardized support for multiple ...
and IEEE 802.11ac and often integrate these using the building-specific wireless mesh open standard
ZigBee Zigbee is an IEEE 802.15.4-based specification for a suite of high-level communication protocols used to create personal area networks with small, low-power digital radios, such as for home automation, medical device data collection, and othe ...
. Proprietary hardware dominates the controller market. Each company has controllers for specific applications. Some are designed with limited controls and no interoperability, such as simple packaged roof top units for HVAC. Software will typically not integrate well with packages from other vendors. Cooperation is at the Zigbee/BACnet/LonTalk level only. Current systems provide interoperability at the application level, allowing users to mix-and-match devices from different manufacturers, and to provide integration with other compatible building
control system A control system manages, commands, directs, or regulates the behavior of other devices or systems using control loops. It can range from a single home heating controller using a thermostat controlling a domestic boiler to large industrial c ...
s. These typically rely on
SNMP Simple Network Management Protocol (SNMP) is an Internet Standard protocol for collecting and organizing information about managed devices on IP networks and for modifying that information to change device behaviour. Devices that typically ...
, long used for this same purpose to integrate diverse computer networking devices into one coherent network.


Protocols and industry standards

*
1-Wire 1-Wire is a device communications bus system designed by Dallas Semiconductor Corp. that provides low-speed (16.3 kbit/s) data, signaling, and power over a single conductor. 1-Wire is similar in concept to I²C, but with lower data rates and ...
*
BACnet BACnet is a communication protocol for building automation and control (BAC) networks that use the ASHRAE, ANSI, and ISO 16484-5 standards protocol. BACnet was designed to allow communication of building automation and control systems for applic ...
*
Bluetooth Bluetooth is a short-range wireless technology standard that is used for exchanging data between fixed and mobile devices over short distances and building personal area networks (PANs). In the most widely used mode, transmission power is limi ...
*
DALI Dali or Dalí may refer to: Chinese history * Kingdom of Dali (937–1253 AD), centered in modern Yunnan * Kingdom of Nanzhao or Dali, Kingdom of Dali's predecessor state * Dali, Emperor Daizong of Tang's third and last regnal period (766–779) ...
* Dynet *
EnOcean The EnOcean technology is an energy harvesting wireless technology used primarily in building automation systems, but also in other application fields such as industry, transportation, logistics or smart homes solutions. The energy harvesting wire ...
*
KNX KNX is an open standard (see EN 50090, ISO/IEC 14543) for commercial and domestic building automation. KNX devices can manage lighting, blinds and shutters, HVAC, security systems, energy management, audio video, white goods, displays, remote ...
*
LonTalk LonTalk is a protocol optimized for control. Originally developed by Echelon Corporation for networking devices over media such as twisted pair, powerlines, fiber optics, and RF. It is popular for the automation of various functions in industri ...
* MIDAC * OPC *
OpenTherm OpenTherm (OT) is a standard communications protocol used in central heating systems for the communication between a central heating boiler and a thermostatic controller. As a standard, OpenTherm is independent of any single manufacturer. A cont ...
*
OpenWebNet OpenWebNet is a communications protocol developed by Bticino since 2000. The OpenWebNet protocol allows a "high-level" interaction between a remote unit and Bus SCS of MyHome domotic system. The latest protocol evolution has been improved to all ...
*
VSCP The Very Simple Control Protocol (VSCP) is a free automation protocol suitable for all sorts of automation task where Building automation, building- or Home automation, home-automation is in the main focus. Its main advantage is that each VSCP- ...
*
Zigbee Zigbee is an IEEE 802.15.4-based specification for a suite of high-level communication protocols used to create personal area networks with small, low-power digital radios, such as for home automation, medical device data collection, and othe ...
* Z-Wave


Security Concerns

With the growing spectrum of capabilities and connections to the
Internet of Things The Internet of things (IoT) describes physical objects (or groups of such objects) with sensors, processing ability, software and other technologies that connect and exchange data with other devices and systems over the Internet or other comm ...
, building automation systems were repeatedly reported to be vulnerable, allowing hackers and cybercriminals to attack their components. Buildings can be exploited by hackers to measure or change their environment: sensors allow surveillance (e.g. monitoring movements of employees or habits of inhabitants) while actuators allow to perform actions in buildings (e.g. opening doors or windows for intruders). Several vendors and committees started to improve the security features in their products and standards, including KNX, ZigBee and BACnet (see recent standards or standard drafts). However, researchers report several open problems in building automation security. On November 11, 2019, a 132-page security research paper was released titled "I Own Your Building (Management System)" by Gjoko Krstic and Sipke Mellema that addressed more than 100 vulnerabilities affecting various BMS and access control solutions by various vendors.


Room automation

Room automation is a subset of building automation and with a similar purpose; it is the consolidation of one or more systems under centralized control, though in this case in one room. The most common example of room automation is corporate boardroom, presentation suites, and lecture halls, where the operation of the large number of devices that define the room function (such as
videoconferencing Videotelephony, also known as videoconferencing and video teleconferencing, is the two-way or multipoint reception and transmission of audio signal, audio and video signals by people in different locations for Real-time, real time communication. ...
equipment, video projectors,
lighting control system A lighting control system is an intelligent network based lighting control solution that incorporates communication between various system inputs and outputs related to lighting control with the use of one or more central computing devices. Light ...
s,
public address A public address system (or PA system) is an electronic system comprising microphones, amplifiers, loudspeakers, and related equipment. It increases the apparent volume (loudness) of a human voice, musical instrument, or other acoustic sound sou ...
systems etc.) would make manual operation of the room very complex. It is common for room automation systems to employ a
touchscreen A touchscreen or touch screen is the assembly of both an input ('touch panel') and output ('display') device. The touch panel is normally layered on the top of an electronic visual display of an information processing system. The display is often ...
as the primary way of controlling each operation.


See also

* Control engineering * Digital home *
Index of home automation articles This is a list of home automation topics on Wikipedia. Home automation is the residential extension of building automation. It is automation of the home, housework or household activity. Home automation may include centralized control of lighti ...
*
Smart environment Smart environments link computers and other smart devices to everyday settings and tasks. Smart environments include smart homes, smart cities and smart manufacturing. Introduction Smart environments are an extension of pervasive computing. Accordi ...
*
Testing, adjusting, balancing In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial buildin ...


References


External links

* * v:Building Automation Provides learning resources for professionals in this area {{DEFAULTSORT:Building Automation Sustainable urban planning