BORAX-III
   HOME

TheInfoList



OR:

The BORAX Experiments were a series of safety experiments on boiling water nuclear reactors conducted by
Argonne National Laboratory Argonne National Laboratory is a science and engineering research United States Department of Energy National Labs, national laboratory operated by University of Chicago, UChicago Argonne LLC for the United States Department of Energy. The facil ...
in the 1950s and 1960s at the National Reactor Testing Station in eastern Idaho.Light Water Reactor Technology Development
Argonne National Laboratory
They were performed using the five BORAX reactors that were designed and built by Argonne. BORAX-III was the first nuclear reactor to supply electrical power to the grid in the United States in 1955.


Evolution of BORAX

This series of tests began in 1952 with the construction of the BORAX-I nuclear reactor. BORAX-I experiment proved that a reactor using direct boiling of water would be practical, rather than unstable, because of the bubble formation in the core. Subsequently, the reactor was used for
power excursion A criticality accident is an accidental uncontrolled nuclear fission chain reaction. It is sometimes referred to as a critical excursion, critical power excursion, or divergent chain reaction. Any such event involves the unintended accumulation ...
tests which showed that rapid conversion of water to steam would safely control the reaction. The final, deliberately destructive test in 1954 produced an unexpectedly large power excursion that "instead of the melting of a few fuel plates, the test melted a major fraction of the entire core." However, this core meltdown and release of
nuclear fuel Nuclear fuel is material used in nuclear power stations to produce heat to power turbines. Heat is created when nuclear fuel undergoes nuclear fission. Most nuclear fuels contain heavy fissile actinide elements that are capable of undergoing ...
and nuclear fission products provided additional useful data to improve mathematical models. The tests proved key safety principles of the design of modern nuclear power reactors. Design power of BORAX-I was 1.4 megawatts thermal. The BORAX-I design was a precursor to the SL-1 plant, which was sited nearby and began operations in 1958. The principles discovered in the BORAX-I experiments helped scientists understand the issues that contributed to the fatal incident at SL-1 in 1961. The BORAX-II reactor was built in 1954, with a design output of 6 MW(t). In March 1955 BORAX-II was intentionally destroyed by taking the reactor "prompt critical". The design of BORAX-II was modified into BORAX-III with the addition of a turbine, proving that turbine contamination would not be a problem. It was linked to the local power grid for about an hour on July 17, 1955. AEC Press release for BORAX-III lighting Arco, Idaho. BORAX-III provided 2,000 kW to power nearby Arco, Idaho (500 kW), the BORAX test facility (500 kW), and partially powered the National Reactor Testing Station (after 2004, the
Idaho National Laboratory Idaho National Laboratory (INL) is one of the national laboratories of the United States Department of Energy and is managed by the Battelle Energy Alliance. While the laboratory does other research, historically it has been involved with nu ...
) (1,000 kW). Thus, Arco became the first community solely powered by nuclear energy. The reactor continued to be used for tests until 1956. BORAX-IV, built in 1956, explored the thorium fuel cycle and uranium-233 fuel with a power of 20 MW thermal. This experiment utilized fuel plates that were purposely full of defects in order to explore long-term plant operation with damaged fuel plates. Radioactive gases were released into the atmosphere. BORAX-V continued the work on boiling water reactor designs, including the use of a
superheater A superheater is a device used to convert saturated steam or wet steam into superheated steam or dry steam. Superheated steam is used in steam turbines for electricity generation, steam engines, and in processes such as steam reforming. There ar ...
. It operated from 1962 to 1964.


BORAX-I destructive test and cleanup

Test synopsis: The destruction of BORAX-I caused the "aerial distribution of contaminants resulting from the final experiment of the BORAX-I reactor" and the likely contamination of the topmost 1 foot of soil over about 2 acres in the vicinity. The site needed to be cleaned up prior to being used for subsequent experiments. The 84,000-square foot (7,800 m2) area was covered with 6 inches of gravel in 1954, but grass, sagebrush, and other plants reseeded the area since then. The BORAX-I burial ground is located about northwest of the Experimental Breeder Reactor-1, a publicly accessible national monument. Since 1987, the United States Environmental Protection Agency has classified the burial ground as
Superfund Superfund is a United States federal environmental remediation program established by the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The program is administered by the United States Environmental Pro ...
site Operable Unit 6-01, one of two such sites (along with SL-1) at the
Idaho National Laboratory Idaho National Laboratory (INL) is one of the national laboratories of the United States Department of Energy and is managed by the Battelle Energy Alliance. While the laboratory does other research, historically it has been involved with nu ...
. In 1995, the EPA ordered the primary remedy of the burial ground should be: "Containment by capping with an engineered barrier constructed primarily of native materials." The site is expected to produce no more than a 2 in 10,000 increase in cancer risk for long term residential use after 320 years, with no significant increase after that time. This risk calculation ignores the shielding provided by the soil cover, which at the time of the EPA decision had reduced exposure to little more than background level, and makes very pessimistic modeling assumptions that greatly increase the projected risk, to deliberately focus on the high rather than low effect side.


See also

* SL-1, the only demonstration of the BORAX-I principles during a real nuclear accident * Experimental Breeder Reactor I first production of electric power


References

;Notes ;Bibliography *


External links

*
BORAX-I reactor
description at
Argonne National Laboratory Argonne National Laboratory is a science and engineering research United States Department of Energy National Labs, national laboratory operated by University of Chicago, UChicago Argonne LLC for the United States Department of Energy. The facil ...
site.
BORAX-II reactor
description at Argonne National Laboratory web site.
BORAX-III reactor
description at Argonne National Laboratory web site.
BORAX-IV reactor
description at Argonne National Laboratory web site.
BORAX-V reactor
description at Argonne National Laboratory web site.
Summaries of BORAX experiments
in Appendix B of Idaho National Laboratory's histor
''Proving the Principle''
* {{authority control Nuclear technology in the United States Nuclear research reactors Nuclear safety and security