Specified Loads
   HOME
*





Specified Loads
In civil engineering, specified loads are the best estimate of the actual loads a structure is expected to carry. These loads come in many different forms, such as people, equipment, vehicles, wind, rain, snow, earthquakes, the building materials themselves, etc. Specified Loads also known as Characteristic loads in many cases. Buildings will be subject to loads from various sources. The principal ones can be classified as live loads (loads which are not always present in the structure), dead loads (loads which are permanent and immovable excepting redesign or renovation) and wind load, as described below. In some cases structures may be subject to other loads, such as those due to earthquakes or pressures from retained material. The expected maximum magnitude of each is referred to as the characteristic load. Dead loads are those representing the self weight of the building; their magnitude can be estimated on the basis of material densities and component sizes. Dead loads are ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Civil Engineering
Civil engineering is a professional engineering discipline that deals with the design, construction, and maintenance of the physical and naturally built environment, including public works such as roads, bridges, canals, dams, airports, sewage systems, pipelines, structural components of buildings, and railways. Civil engineering is traditionally broken into a number of sub-disciplines. It is considered the second-oldest engineering discipline after military engineering, and it is defined to distinguish non-military engineering from military engineering. Civil engineering can take place in the public sector from municipal public works departments through to federal government agencies, and in the private sector from locally based firms to global Fortune 500 companies. History Civil engineering as a discipline Civil engineering is the application of physical and scientific principles for solving the problems of society, and its history is intricately linked to advances in t ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Live Load
A structural load or structural action is a force, deformation, or acceleration applied to structural elements. A load causes stress, deformation, and displacement in a structure. Structural analysis, a discipline in engineering, analyzes the effects of loads on structures and structural elements. Excess load may cause structural failure, so this should be considered and controlled during the design of a structure. Particular mechanical structures—such as aircraft, satellites, rockets, space stations, ships, and submarines—are subject to their own particular structural loads and actions. Engineers often evaluate structural loads based upon published regulations, contracts, or specifications. Accepted technical standards are used for acceptance testing and inspection. Types Dead loads are static forces that are relatively constant for an extended time. They can be in tension or compression. The term can refer to a laboratory test method or to the normal usage of a material or ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Dead Load
A structural load or structural action is a force, deformation, or acceleration applied to structural elements. A load causes stress, deformation, and displacement in a structure. Structural analysis, a discipline in engineering, analyzes the effects of loads on structures and structural elements. Excess load may cause structural failure, so this should be considered and controlled during the design of a structure. Particular mechanical structures—such as aircraft, satellites, rockets, space stations, ships, and submarines—are subject to their own particular structural loads and actions. Engineers often evaluate structural loads based upon published regulations, contracts, or specifications. Accepted technical standards are used for acceptance testing and inspection. Types Dead loads are static forces that are relatively constant for an extended time. They can be in tension or compression. The term can refer to a laboratory test method or to the normal usage of a mate ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Floor To Ceiling Sandwich
A floor is the bottom surface of a room or vehicle. Floors vary from simple dirt in a cave to many layered surfaces made with modern technology. Floors may be stone, wood, bamboo, metal or any other material that can support the expected load. The levels of a building are often referred to as floors, although a more proper term is storey. Floors typically consist of a subfloor for support and a floor covering used to give a good walking surface. In modern buildings the subfloor often has electrical wiring, plumbing, and other services built in. As floors must meet many needs, some essential to safety, floors are built to strict building codes in some regions. Special floor structures Where a special floor structure like a floating floor is laid upon another floor, both may be called subfloors. Special floor structures are used for a number of purposes: * Balcony, a platform projecting from a wall * Floating floor, normally for noise or vibration reduction * Glass floor ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Terrazzo
Terrazzo is a composite material, poured in place or precast, which is used for floor and wall treatments. It consists of chips of marble, quartz, granite, glass, or other suitable material, poured with a cementitious binder (for chemical binding), polymeric (for physical binding), or a combination of both. Metal strips often divide sections, or changes in color or material in a pattern. Additional chips may be sprinkled atop the mix before it sets. After it is cured it is ground and polished smooth or otherwise finished to produce a uniformly textured surface. "Terrazzo" is also often used to describe any pattern similar to the original terrazzo floors. History Terrazzo proper Although the history of terrazzo can be traced back to the ancient mosaics of Egypt, its more recent predecessors come from Italy. The form of terrazzo used today derives partly from the 18th century ''pavimento alla Veneziana'' ( Venetian pavement) and the cheaper ''seminato.'' ''Pavimento alla Venezi ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Design Load
In a general sense, the design load is the maximum amount of something a system is designed to handle or the maximum amount of something that the system can produce, which are very different meanings. For example, a crane with a design load of 20 tons is designed to be able to lift loads that weigh 20 tons or less. However, when a failure could be catastrophic, such as a crane dropping its load or collapsing entirely, a factor of safety is necessary. As a result, the crane should lift about 2 to 5 tons at the most. In structural design, a design load is greater than the load which the system is expected to support. This is because engineers incorporate a safety factor in their design, in order to ensure that the system will be able to support at least the expected loads (called specified loads, despite any problems with construction, materials, etc. that go unnoticed during construction. A heater would have a general design load, meaning the maximum amount of heat it can produce ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Load Factor (real Estate)
A common area is, in real estate or real property law, the "area which is available for use by more than one person..." The common areas are those that are available for common use by all tenants, (or) groups of tenants and their invitees.kwcondo
In Texas and other parts of the United States, it is "An area inside a housing development owned by all residents or by an overall management structure which charges each tenant for maintenance and upkeep."Common Area
laws.com retrieved from real-estate.laws.com Accessed 28 November 2012.
Common areas often exist in apartments, gated communities, condominiums, cooperatives and shopping malls. In any situation where there is a tenancy in common, all the tenants in c ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Safety Factor
In engineering, a factor of safety (FoS), also known as (and used interchangeably with) safety factor (SF), expresses how much stronger a system is than it needs to be for an intended load. Safety factors are often calculated using detailed analysis because comprehensive testing is impractical on many projects, such as bridges and buildings, but the structure's ability to carry a load must be determined to a reasonable accuracy. Many systems are intentionally built much stronger than needed for normal usage to allow for emergency situations, unexpected loads, misuse, or degradation (reliability). Definition There are two definitions for the factor of safety (FoS): * The ratio of a structure's absolute strength (structural capability) to actual applied load; this is a measure of the reliability of a particular design. This is a calculated value, and is sometimes referred to, for the sake of clarity, as a ''realized factor of safety''. * A constant required value, imposed by law, ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  




Design Load
In a general sense, the design load is the maximum amount of something a system is designed to handle or the maximum amount of something that the system can produce, which are very different meanings. For example, a crane with a design load of 20 tons is designed to be able to lift loads that weigh 20 tons or less. However, when a failure could be catastrophic, such as a crane dropping its load or collapsing entirely, a factor of safety is necessary. As a result, the crane should lift about 2 to 5 tons at the most. In structural design, a design load is greater than the load which the system is expected to support. This is because engineers incorporate a safety factor in their design, in order to ensure that the system will be able to support at least the expected loads (called specified loads, despite any problems with construction, materials, etc. that go unnoticed during construction. A heater would have a general design load, meaning the maximum amount of heat it can produce ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Limit States Design
Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria.EN 1990:2002 E, Eurocode - Basis of Structural Design, CEN, November 29, 2001 The condition may refer to a degree of loading or other actions on the structure, while the criteria refer to structural integrity, fitness for use, durability or other design requirements. A structure designed by LSD is proportioned to sustain all actions likely to occur during its design life, and to remain fit for use, with an appropriate level of reliability for each limit state. Building codes based on LSD implicitly define the appropriate levels of reliability by their prescriptions. The method of limit state design, developed in the USSR and based on research led by Professor N.S. Streletski, was introduced in USSR building regulations in 1955. Criteria ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Allowable Stress Design
Permissible stress design is a design philosophy used by mechanical engineers and civil engineers. The civil designer ensures that the stresses developed in a structure due to service loads do not exceed the elastic limit. This limit is usually determined by ensuring that stresses remain within the limits through the use of factors of safety. In structural engineering, the permissible stress design approach has generally been replaced internationally by limit state design (also known as ultimate stress design, or in USA, Load and Resistance Factor Design, LRFD) as far as structural engineering is considered, except for some isolated cases. In USA structural engineering construction, allowable stress design (ASD) has not yet been completely superseded by limit state design except in the case of Suspension bridges, which changed from allowable stress design to limit state design in the 1960s. Wood, steel, and other materials are still frequently designed using allowable stress d ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]