HOME





Server Immersion Cooling
Immersion cooling technology encompasses systems in which electronic components are directly exposed to and interact with dielectric fluids for cooling purposes. This includes systems using single-phase or two-phase dielectric liquids, leveraging their thermal capabilities to manage and dissipate heat generated by electronic components. Heat is removed from the system by putting the coolant in direct contact with hot components, and circulating the heated liquid through heat exchangers. This practice is highly effective as liquid coolants can absorb more heat from the system than air. Immersion cooling has many benefits, including but not limited to: sustainability, performance, reliability, and cost. The fluids used in immersion cooling are dielectric liquids to ensure that they can safely come into contact with energized electronic components. Commonly used dielectric liquids in immersion cooling are synthetic hydrocarbons, esters (natural and synthetic) and fluorochemicals. ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Liquid Dielectric
A liquid dielectric is a dielectric material in liquid state. Its main purpose is to prevent or rapidly quench electric discharges. Dielectric liquids are used as electrical insulators in high voltage applications, e.g. transformers, capacitors, high voltage cables, and switchgear (namely high voltage switchgear). Its function is to provide electrical insulation, suppress corona and arcing, and to serve as a coolant. A good liquid dielectric should have high dielectric strength, high thermal stability and inertness against the construction materials used, non-flammability and low toxicity, good heat transfer properties, and low cost. Liquid dielectrics are self-healing; when an electric breakdown occurs, the discharge channel does not leave a permanent conductive trace in the fluid. The electrical properties tend to be strongly influenced by dissolved gases (e.g. oxygen or carbon dioxide), dust, fibers, and especially ionic impurities and moisture. Electrical discharge may cause ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Kinetic Energy Recovery System
A kinetic energy recovery system (KERS) is an automotive system for recovering a moving vehicle's kinetic energy under braking. The recovered energy is stored in a reservoir (for example a flywheel or high voltage batteries) for later use under acceleration. Examples include complex high end systems such as the Zytek, Flybrid, Torotrak and Xtrac used in Formula One racing and simple, easily manufactured and integrated differential based systems such as the Cambridge Passenger/Commercial Vehicle Kinetic Energy Recovery System (CPC-KERS). Xtrac and Flybrid are both licensees of Torotrak's technologies, which employ a small and sophisticated ancillary gearbox incorporating a continuously variable transmission (CVT). The CPC-KERS is similar as it also forms part of the driveline assembly. However, the whole mechanism including the flywheel sits entirely in the vehicle's hub (looking like a drum brake). In the CPC-KERS, a differential replaces the CVT and transfers torque between ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Hydrofluoroether
Hydrofluoroethers (HFEs) are a class of organic solvents. As non-ozone-depleting chemicals, they were developed originally as a replacement for Chlorofluorocarbon, CFCs, Hydrofluorocarbon, HFCs, hydrochlorofluorocarbon, HCFCs, and Perfluorocarbon, PFCs. They are typically colorless, odorless, tasteless, low toxicity, low viscosity, and liquid at room temperature. The boiling point of HFEs vary from to nearly . Although 3M first developed HFEs, other manufacturers have begun producing them. Applications Industrial uses are many and varied, including: * Vapor de-greasing solvent * Refrigerant and heat-transfer fluid * Anhydrous fluid cleaner They are sometimes applied as blends such as HFE 7100, which is a mixture of methyl nonafluorobutyl ether (methoxyperfluorobutane) and methyl nonafluoroisobutyl ether. 3M produces hydrofluoroether compounds under the names Novec 7000, 7100, 7200, 7300, 7500, and 7700 as liquid coolants for many applications, including full immersion cooling of ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Liquid Dielectric
A liquid dielectric is a dielectric material in liquid state. Its main purpose is to prevent or rapidly quench electric discharges. Dielectric liquids are used as electrical insulators in high voltage applications, e.g. transformers, capacitors, high voltage cables, and switchgear (namely high voltage switchgear). Its function is to provide electrical insulation, suppress corona and arcing, and to serve as a coolant. A good liquid dielectric should have high dielectric strength, high thermal stability and inertness against the construction materials used, non-flammability and low toxicity, good heat transfer properties, and low cost. Liquid dielectrics are self-healing; when an electric breakdown occurs, the discharge channel does not leave a permanent conductive trace in the fluid. The electrical properties tend to be strongly influenced by dissolved gases (e.g. oxygen or carbon dioxide), dust, fibers, and especially ionic impurities and moisture. Electrical discharge may cause ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Open Compute Project
The Open Compute Project (OCP) is an organization that facilitates the sharing of data center product designs and industry best practices among companies. Founded in 2011, OCP has significantly influenced the design and operation of large-scale computing facilities worldwide. As of February 2025, over 400 companies across the world are members of OCP, including Arm, Meta, IBM, Wiwynn, Intel, Nokia, Google, Microsoft, Seagate Technology, Dell, Rackspace, Hewlett Packard Enterprise, NVIDIA, Cisco, Goldman Sachs, Fidelity, Lenovo, Accton Technology Corporation and Alibaba Group. Structure The Open Compute Project Foundation is a 501(c)(6) non-profit incorporated in the state of Delaware, United States. OCP has multiple committees, including the board of directors, advisory board and steering committee to govern its operations. As of July 2020, there are seven members who serve on the board of directors which is made up of one individual member and six organizational members. ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


Cray T90
The Cray T90 series (code-named ''Triton'' during development) was the last of a line of vector processing supercomputers manufactured by Cray Research, Inc, superseding the Cray C90 series. The first machines were shipped in 1995, and featured a 2.2 ns (450 MHz) clock cycle and two-wide vector pipes, for a peak speed of 1.8 gigaflops per processor; the high clock speed arises from the CPUs being built using ECL logic. As with the Cray J90, each CPU contained a scalar data cache, in addition to the instruction buffering/caching which has always been in Cray architectures. Configurations were available with between four and 32 processors, and with either IEEE 754 or traditional Cray floating-point arithmetic; the processors shared an SRAM main memory of up to eight gigabytes, with a bandwidth of three 64-bit words per cycle per CPU (giving a 32-CPU STREAM bandwidth of 360 gigabytes per second). The clock signal is distributed via a fiber-optic harness to the processors. T ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Remotely Operated Underwater Vehicle
A remotely operated underwater vehicle (ROUV) or remotely operated vehicle (ROV) is a free-swimming submersible craft used to perform underwater observation, inspection and physical tasks such as valve operations, hydraulic functions and other general tasks within the subsea oil and gas industry, military, scientific and other applications. ROVs can also carry tooling packages for undertaking specific tasks such as pull-in and connection of flexible flowlines and umbilicals, and component replacement. They are often used to do research and commercial work at great depths beyond the capacities of most submersibles and divers. Description This meaning is different from remote control vehicles operating on land or in the air because ROVs are designed specifically to function in underwater environments, where conditions such as high pressure, limited visibility, and the effects of buoyancy and water currents pose unique challenges. While land and aerial vehicles use wireless commu ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Cryptocurrency
A cryptocurrency (colloquially crypto) is a digital currency designed to work through a computer network that is not reliant on any central authority, such as a government or bank, to uphold or maintain it. Individual coin ownership records are stored in a digital ledger or blockchain, which is a computerized database that uses a consensus mechanism to secure transaction records, control the creation of additional coins, and verify the transfer of coin ownership. The two most common consensus mechanisms are proof of work and proof of stake. Despite the name, which has come to describe many of the fungible blockchain tokens that have been created, cryptocurrencies are not considered to be currencies in the traditional sense, and varying legal treatments have been applied to them in various jurisdictions, including classification as commodities, securities, and currencies. Cryptocurrencies are generally viewed as a distinct asset class in practice. The first cryptocu ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

Heat Exchanger
A heat exchanger is a system used to transfer heat between a source and a working fluid. Heat exchangers are used in both cooling and heating processes. The fluids may be separated by a solid wall to prevent mixing or they may be in direct contact. They are widely used in space heating, refrigeration, air conditioning, power stations, chemical plants, Petrochemical, petrochemical plants, Oil refinery, petroleum refineries, natural-gas processing, and sewage treatment. The classic example of a heat exchanger is found in an internal combustion engine in which a circulating fluid known as engine coolant flows through radiator coils and air flows past the coils, which cools the coolant and heats the incoming air. Another example is the heat sink, which is a passive heat exchanger that transfers the heat generated by an electronic or a mechanical device to a fluid medium, often air or a liquid coolant. Flow arrangement There are three primary classifications of heat exchangers accord ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]  


picture info

HPCC
HPCC (High-Performance Computing Cluster), also known as DAS (Data Analytics Supercomputer), is an open source, data-intensive computing system platform developed by LexisNexis Risk Solutions. The HPCC platform incorporates a software architecture implemented on Commodity_computing, commodity computing clusters to provide high-performance, data-parallel processing for applications utilizing big data. The HPCC platform includes system configurations to support both parallel batch data processing (Thor) and high-performance online query applications using indexed data files (Roxie). The HPCC platform also includes a data-centric declarative programming language for parallel data processing called ECL (data-centric programming language), ECL. The public release of HPCC waannouncedin 2011, after ten years of in-house development (according to LexisNexis). It is an alternative to Hadoop and other Big data platforms. System architecture The HPCC system architecture includes tw ...
[...More Info...]      
[...Related Items...]     OR:     [Wikipedia]   [Google]   [Baidu]