HOME

TheInfoList



OR:

The flicker fusion threshold, also known as critical flicker frequency or flicker fusion rate, is the frequency at which a flickering light appears steady to the average human observer. It is a concept studied in
vision science Vision science is the scientific study of visual perception. Researchers in vision science can be called vision scientists, especially if their research spans some of the science's many disciplines. Vision science encompasses all studies of vision ...
, more specifically in the
psychophysics Psychophysics is the field of psychology which quantitatively investigates the relationship between physical stimulus (physiology), stimuli and the sensation (psychology), sensations and perceptions they produce. Psychophysics has been described ...
of
visual perception Visual perception is the ability to detect light and use it to form an image of the surrounding Biophysical environment, environment. Photodetection without image formation is classified as ''light sensing''. In most vertebrates, visual percept ...
. A traditional term for "flicker fusion" is "
persistence of vision Persistence of vision is the optical illusion that occurs when the visual perception of an object does not cease for some time after the Light ray, rays of light proceeding from it have ceased to enter the eye. The illusion has also been descr ...
", but this has also been used to describe positive afterimages or
motion blur Motion blur is the apparent streaking of moving objects in a photograph or a sequence of frames, such as a film or animation. It results when the image being recorded changes during the recording of a single exposure, due to rapid movement or l ...
. Although flicker can be detected for many waveforms representing time-variant fluctuations of intensity, it is conventionally, and most easily, studied in terms of sinusoidal modulation of intensity. There are seven parameters that determine the ability to detect the flicker: # the frequency of the modulation; # the amplitude or depth of the modulation (i.e., what is the maximum percent decrease in the illumination intensity from its peak value); # the average (or maximum—these can be inter-converted if modulation depth is known) illumination intensity; # the wavelength (or wavelength range) of the illumination (this parameter and the illumination intensity can be combined into a single parameter for humans or other animals for which the sensitivities of rods and cones are known as a function of wavelength using the
luminous flux In photometry, luminous flux or luminous power is the measure of the perceived power of light. It differs from radiant flux, the measure of the total power of electromagnetic radiation (including infrared, ultraviolet, and visible light), in that ...
function); # the position on the retina at which the stimulation occurs (due to the different distribution of photoreceptor types at different positions); # the degree of light or dark adaptation, i.e., the duration and intensity of previous exposure to background light, which affects both the intensity sensitivity and the time resolution of vision; # physiological factors such as age, sex, and fatigue.


Explanation

As long as the modulation frequency is kept above the fusion threshold, the perceived intensity can be changed by changing the relative periods of light and darkness. One can prolong the dark periods and thus darken the image; therefore the effective and average brightness are equal. This is known as the Talbot-Plateau law."eye, human." Encyclopædia Britannica. 2008.
Encyclopædia Britannica 2006 Ultimate Reference Suite DVD An encyclopedia is a reference work or compendium providing summaries of knowledge, either general or special, in a particular field or discipline. Encyclopedias are divided into articles or entries that are arranged alphabetically by artic ...
Like all psychophysical thresholds, the flicker fusion threshold is a statistical rather than an absolute quantity. There is a range of frequencies within which flicker sometimes will be seen and sometimes will not be seen, and the threshold is the frequency at which flicker is detected on 50% of trials. Different points in the visual system have very different critical flicker fusion rate (CFF) sensitivities; the overall threshold frequency for perception cannot exceed the slowest of these for a given modulation amplitude. Each cell type integrates signals differently. For example, rod photoreceptor cells, which are exquisitely sensitive and capable of single-photon detection, are very sluggish, with time constants in mammals of about 200 ms.
Cones In geometry, a cone is a three-dimensional figure that tapers smoothly from a flat base (typically a circle) to a point not contained in the base, called the ''apex'' or '' vertex''. A cone is formed by a set of line segments, half-lines, ...
, in contrast, while having much lower intensity sensitivity, have much better time resolution than rods do. For both rod- and cone-mediated vision, the fusion frequency increases as a function of illumination intensity, until it reaches a plateau corresponding to the maximal time resolution for each type of vision. The maximal fusion frequency for rod-mediated vision reaches a plateau at about 15 
hertz The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), often described as being equivalent to one event (or Cycle per second, cycle) per second. The hertz is an SI derived unit whose formal expression in ter ...
(Hz), whereas cones reach a plateau, observable only at very high illumination intensities, of about 60 Hz. In addition to increasing with average illumination intensity, the fusion frequency also increases with the extent of modulation (the maximal relative decrease in light intensity presented); for each frequency and average illumination, there is a characteristic modulation threshold, below which the flicker cannot be detected, and for each modulation depth and average illumination, there is a characteristic frequency threshold. These values vary with the wavelength of illumination, because of the wavelength dependence of photoreceptor sensitivity, and they vary with the position of the illumination within the retina, because of the concentration of cones in central regions including the fovea and the
macula The macula (/ˈmakjʊlə/) or macula lutea is an oval-shaped pigmented area in the center of the retina of the human eye and in other animals. The macula in humans has a diameter of around and is subdivided into the umbo, foveola, foveal avas ...
, and the dominance of rods in the peripheral regions of the retina.


Technological considerations


Display frame rate

Flicker fusion is important in all technologies for presenting moving images, nearly all of which depend on presenting a rapid succession of static images (e.g. the
frame A frame is often a structural system that supports other components of a physical construction and/or steel frame that limits the construction's extent. Frame and FRAME may also refer to: Physical objects In building construction *Framing (con ...
s in a cinema film, TV show, or a
digital video Digital video is an electronic representation of moving visual images (video) in the form of encoded digital data. This is in contrast to analog video, which represents moving visual images in the form of analog signals. Digital video comprises ...
file). If the
frame rate Frame rate, most commonly expressed in frame/s, or FPS, is typically the frequency (rate) at which consecutive images (Film frame, frames) are captured or displayed. This definition applies to film and video cameras, computer animation, and moti ...
falls below the flicker fusion threshold for the given viewing conditions, flicker will be apparent to the observer, and movements of objects on the film will appear jerky. For the purposes of presenting moving images, the human flicker fusion threshold is usually taken between 60 and 90 Hz, though in certain cases it can be higher by an order of magnitude. In practice, movies since the
silent era A silent film is a film without synchronized recorded sound (or more generally, no audible dialogue). Though silent films convey narrative and emotion visually, various plot elements (such as a setting or era) or key lines of dialogue may, wh ...
are recorded at 24 frames per second and displayed by interrupting each frame two or three times for a flicker of 48 or 72 Hz. Television typically originates at 50 or 60 frames or interlaced
fields Fields may refer to: Music *Fields (band), an indie rock band formed in 2006 * Fields (progressive rock band), a progressive rock band formed in 1971 * ''Fields'' (album), an LP by Swedish-based indie rock band Junip (2010) * "Fields", a song by ...
per second. The flicker fusion threshold does not prevent indirect detection of a high frame rate, such as the phantom array effect or
wagon-wheel effect The wagon-wheel effect (alternatively called stagecoach-wheel effect) is an optical illusion in which a spoked wheel appears to rotate differently from its true rotation. The wheel can appear to rotate more slowly than the true rotation, it ca ...
, as human-visible side effects of a finite frame rate were still seen on an experimental 480 Hz display.


Display refresh rate

Cathode-ray tube A cathode-ray tube (CRT) is a vacuum tube containing one or more electron guns, which emit electron beams that are manipulated to display images on a phosphorescent screen. The images may represent electrical waveforms on an oscilloscope, a ...
(CRT) displays typically operated at a
vertical scan rate The refresh rate, also known as vertical refresh rate, vertical scan rate or vertical frequency in reference to terminology originating with the cathode-ray tubes (CRTs), is the number of times per second that a raster-based display device displa ...
of 60 Hz (NTSC) or 50 Hz (PAL/SECAM), the same as
SDTV Standard-definition television (SDTV; also standard definition or SD) is a television system that uses a resolution that is not considered to be either high or enhanced definition. ''Standard'' refers to offering a similar resolution to the ...
content they displayed, which resulted in noticeable flicker. The same was true of other impulsed technologies such as
plasma display A plasma display panel is a type of flat-panel display that uses small cells containing Plasma (physics), plasma: Ionization, ionized gas that responds to electric fields. Plasma televisions were the first large (over diagonal) flat-panel displ ...
s. Some systems could increase refresh rate to higher values such as 72, 75, 100, or 120 Hz to ease this problem, though even if the faster refresh is an integer multiple of the source material framerate to eliminate
judder Telecine ( or ), or TK, is the process of transferring film into video and is performed in a color suite. The term is also used to refer to the equipment used in this post-production process. Telecine enables a motion picture, captured origi ...
, without higher framerate source material this causes the perception of duplicate images. Any flicker on
sample and hold In electronics, a sample and hold (also known as sample and follow) circuit is an analog device that samples (captures, takes) the voltage of a continuously varying analog signal and holds (locks, freezes) its value at a constant level for a ...
technologies such as
LCD A liquid-crystal display (LCD) is a flat-panel display or other electronically modulated optical device that uses the light-modulating properties of liquid crystals combined with polarizers to display information. Liquid crystals do not em ...
or
OLED An organic light-emitting diode (OLED), also known as organic electroluminescent (organic EL) diode, is a type of light-emitting diode (LED) in which the emissive electroluminescent layer is an organic compound film that emits light in respon ...
, is unrelated to refresh rate and far less conspicuous, instead coming from incidental design compromises such as
fluorescent Fluorescence is one of two kinds of photoluminescence, the emission of light by a substance that has absorbed light or other electromagnetic radiation. When exposed to ultraviolet radiation, many substances will glow (fluoresce) with color ...
backlights, PWM dimming, or temporal dithering, all of which are eliminated on some devices that do not flicker at all. Because of the resulting
display motion blur In modern displays, motion blur is an unwanted artifact caused primarily by: # Retinal blur resulting from your eyes ''continuously'' tracking ''discrete'' movement. While your eyes move, the object you're tracking remains stationary throu ...
inherent to sample and hold screens, in applications where accurate
motion perception Motion perception is the process of inferring the speed and direction of elements in a scene based on visual, vestibular and proprioceptive inputs. Although this process appears straightforward to most observers, it has proven to be a difficul ...
is prioritized over user fatigue, the correct type of flicker can be reintroduced through techniques such as backlight strobing or black frame insertion.


Lighting

Flicker is also important in the field of domestic (
alternating current Alternating current (AC) is an electric current that periodically reverses direction and changes its magnitude continuously with time, in contrast to direct current (DC), which flows only in one direction. Alternating current is the form in w ...
) lighting, where noticeable flicker can be caused by varying electrical loads, and hence can be very disturbing to electric utility customers. Most electricity providers have maximum flicker limits that they try to meet for domestic customers.
Fluorescent lamp A fluorescent lamp, or fluorescent tube, is a low-pressure mercury-vapor gas-discharge lamp that uses fluorescence to produce visible light. An electric current in the gas excites mercury vapor, to produce ultraviolet and make a phosphor ...
s using conventional magnetic ballasts flicker at twice the supply frequency. Electronic ballasts do not produce light flicker since the phosphor persistence is longer than a half cycle of the higher operation frequency of 20 kHz. The 100–120 Hz flicker produced by magnetic ballasts is associated with headaches and eyestrain. Individuals with high critical flicker fusion threshold are particularly affected by light from fluorescent fixtures that have magnetic ballasts: their EEG alpha waves are markedly attenuated and they perform office tasks with greater speed and decreased accuracy. The problems are not observed with electronic ballasts. Ordinary people have better reading performance using high-frequency (20–60 kHz) electronic ballasts than magnetic ballasts, although the effect was small except at high contrast ratio. The flicker of fluorescent lamps, even with magnetic ballasts, is so rapid that it is unlikely to present a hazard to individuals with
epilepsy Epilepsy is a group of Non-communicable disease, non-communicable Neurological disorder, neurological disorders characterized by a tendency for recurrent, unprovoked Seizure, seizures. A seizure is a sudden burst of abnormal electrical activit ...
. Early studies suspected a relationship between the flickering of fluorescent lamps with magnetic ballasts and repetitive movement in
autistic Autism, also known as autism spectrum disorder (ASD), is a neurodevelopmental disorder characterized by differences or difficulties in social communication and interaction, a preference for predictability and routine, sensory processing di ...
children. However, these studies had interpretive problems and have not been replicated. LED lamps generally do not benefit from flicker attenuation through phosphor persistence, the notable exception being white LEDs. Flicker at frequencies as high as 2000 Hz (2 kHz) can be perceived by humans during
saccades In vision science, a saccade ( ; ; ) is a quick, simultaneous movement of both eyes between two or more phases of focal points in the same direction. In contrast, in smooth-pursuit movements, the eyes move smoothly instead of in jumps. Control ...
, and frequencies above 3000 Hz (3 kHz) have been recommended to avoid human biological effects.


Visual phenomena

In some cases, it is possible to see flicker at rates beyond 2000 Hz (2 kHz) in the case of high-speed eye movements (
saccade In vision science, a saccade ( ; ; ) is a quick, simultaneous movement of both Eye movement (sensory), eyes between two or more phases of focal points in the same direction. In contrast, in Smooth pursuit, smooth-pursuit movements, the eyes mov ...
s) or object motion, via the "phantom array" effect. Fast-moving flickering objects zooming across view (either by object motion, or by eye motion such as rolling eyes), can cause a dotted or multicolored blur instead of a continuous blur, as if they were multiple objects.
Stroboscope A stroboscope, also known as a strobe, is an instrument used to make a cyclically moving object appear to be slow-moving, or stationary. It consists of either a rotating disk with slots or holes or a lamp such as a flashtube which produces br ...
s are sometimes used to induce this effect intentionally. Some special effects, such as certain kinds of electronic glowsticks commonly seen at outdoor events, have the appearance of a solid color when motionless but produce a multicolored or dotted blur when waved about in motion. These are typically LED-based glow sticks. The variation of the duty cycle upon the LED(s), results in usage of less power while by the properties of flicker fusion having the direct effect of varying the brightness. When moved, if the frequency of duty cycle of the driven LED(s) is below the flicker fusion threshold timing differences between the on/off state of the LED(s) becomes evident, and the color(s) appear as evenly spaced points in the peripheral vision. A related phenomenon is the rainbow effect, where different colors are displayed in different places on the screen for the same object due to fast motion.


Flicker

'' Flicker'' is the perception of visual fluctuations in intensity and unsteadiness in the presence of a light stimulus, that is seen by a static observer within a static environment. Flicker that is visible to the human eye will operate at a frequency of up to 80 Hz.


Stroboscopic effect

The ''
stroboscopic effect The stroboscopic effect is a visual optical phenomenon, phenomenon caused by aliasing that occurs when continuous rotational or other cyclic motion is represented by a series of short or instantaneous samples (as opposed to a continuous view) at ...
'' is sometimes used to "stop motion" or to study small differences in repetitive motions. The stroboscopic effect refers to the phenomenon that occurs when there is a change in perception of motion, caused by a light stimulus that is seen by a static observer within a dynamic environment. The stroboscopic effect will typically occur within a frequency range between 80 and 2000 Hz, though can go well beyond to 10,000 Hz for a percentage of population.


Phantom array

Phantom array, also known as the ghosting effect, occurs when there is a change in perception of shapes and spatial positions of objects. The phenomenon is caused by a light stimulus in combination with rapid eye movements (saccades) of an observer in a static environment. Similar to the stroboscopic effect, the phantom effect will also occur at similar frequency ranges. The mouse arrow is a common example of the phantom array effect.


Non-human species

The flicker fusion threshold also varies between
species A species () is often defined as the largest group of organisms in which any two individuals of the appropriate sexes or mating types can produce fertile offspring, typically by sexual reproduction. It is the basic unit of Taxonomy (biology), ...
. A 2014 survey of the critical fusion frequency in animals found the lowest value (6.7 Hz) in the cane toad (''Bufo marinus'') and the highest value (400 Hz) in the black fire beetle (''Melanophila acuminate''). Estimates for different species of bird vary from 40 Hz to 140 Hz, with higher values tending to be associated with faster-moving species. Many mammals have a higher proportion of rods in their retina than humans do, and it is likely that they would also have higher flicker fusion thresholds. This has been confirmed in dogs. If artificial lighting is perceived as flickering by some animals, the aversive effect might be an issue for animal welfare and conservation. However, those animals most liable to perceive flicker tend to be diurnal species active in bright light, and thus least likely to be exposed to artificial lighting outside of captivity. Size and metabolic rate are two further factors associated with the variation in flicker fusion thresholds: small animals with a high metabolic rate tend to have high values.


See also

* Broca-Sulzer effect *
CDR computerized assessment system The CDR system (The CDR system) is a computerized battery of cognitive tests designed in the late 1970s by Professor Keith Wesnes at the University of Reading in Berkshire, England, for repeated testing in clinical trials. Task stimuli are prese ...
*
Frame rate Frame rate, most commonly expressed in frame/s, or FPS, is typically the frequency (rate) at which consecutive images (Film frame, frames) are captured or displayed. This definition applies to film and video cameras, computer animation, and moti ...
*
Persistence of vision Persistence of vision is the optical illusion that occurs when the visual perception of an object does not cease for some time after the Light ray, rays of light proceeding from it have ceased to enter the eye. The illusion has also been descr ...
*
Refresh rate The refresh rate, also known as vertical refresh rate, vertical scan rate or vertical frequency in reference to terminology originating with the cathode-ray tubes (CRTs), is the number of times per second that a raster-based display device displa ...
*
Tweening Inbetweening, also known as tweening, is a process in animation that involves creating intermediate frames, called inbetweens, between two keyframes. The intended result is to create the illusion of movement by smoothly transitioning one image in ...


References


External links

* * {{Cite web , url=http://scienceblogs.com/pharyngula/2006/11/i_get_it_i_know_im_inferior.php , title=I get it, I know I'm inferior{{Snd comments , date=November 9, 2006 , website=Science Blogs{{Snd Pharyngula , archive-url=https://web.archive.org/web/20081230180628/http://scienceblogs.com/pharyngula/2006/11/i_get_it_i_know_im_inferior.php , archive-date=2008-12-30 }
IEC Flicker Meter (PDF)
Why we can't drive safely at high speed

(
Wayback Machine The Wayback Machine is a digital archive of the World Wide Web founded by Internet Archive, an American nonprofit organization based in San Francisco, California. Launched for public access in 2001, the service allows users to go "back in ...
copies) Vision