A motor capacitor is an electrical
capacitor In electrical engineering, a capacitor is a device that stores electrical energy by accumulating electric charges on two closely spaced surfaces that are insulated from each other. The capacitor was originally known as the condenser, a term st ...
that alters the current to one or more windings of a
single-phase In electrical engineering, single-phase electric power (abbreviated 1φ) is the distribution of alternating current electric power using a system in which all the voltages of the supply vary in unison. Single-phase distribution is used when loads ...
alternating-current
induction motor An induction motor or asynchronous motor is an AC motor, AC electric motor in which the electric current in the rotor (electric), rotor that produces torque is obtained by electromagnetic induction from the magnetic field of the stator winding ...
to create a rotating magnetic field. There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run capacitor). Motor capacitors are used with single-phase electric motors that are in turn used to drive
air conditioner Air conditioning, often abbreviated as A/C (US) or air con (UK), is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature, and in some cases, also controlling the humidity of internal air. Air c ...
s,
hot tub A hot tub is a large tub full of water used for hydrotherapy, relaxation or pleasure. Some have powerful jets for massage purposes. Hot tubs are sometimes also known as "spas" or by the trade name Jacuzzi. Hot tubs may be located outdoors or ...
/
jacuzzi Jacuzzi is an American private company that manufactures and markets hot tubs, pools, and other bath products. It is best known for the Jacuzzi hydrotherapy products. The company is headquartered in Irvine, California. It is the largest hot tu ...
spa pumps, powered gates, large fans or
forced-air A forced-air central heating system is one which uses air as its heat transfer medium. These systems rely on ductwork, vents, and plenums as means of air distribution, separate from the actual heating and air conditioning systems. The return ...
heat furnaces for example. A "dual run capacitor" is used in some
air conditioner Air conditioning, often abbreviated as A/C (US) or air con (UK), is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature, and in some cases, also controlling the humidity of internal air. Air c ...
compressor units, to boost both the fan and compressor motors. Permanent-split capacitor (PSC) motors use a motor capacitor that is not disconnected from the motor.


Start capacitors

Start capacitors lag the voltage to the rotor windings creating a phase shift between field windings and rotor windings. Without the start capacitor, the north and south magnetic fields will line up and the motor hums and will only start spinning when physically turned, creating a phase shift. A start capacitor stays in the circuit long enough to rapidly bring the motor up to a predetermined speed, which is usually about 75% of the full speed, and is then taken out of the circuit, often by a
centrifugal switch A centrifugal switch is an electric switch that operates using the centrifugal force created from a rotating shaft, most commonly that of an electric motor or gasoline engine. The switch is designed to activate or de-activate as a function of t ...
that releases at that speed. Afterward the motor works more efficiently with a run capacitor which makes the power factor closer to one.. Start capacitors usually have ratings above 70μF, with four major voltage classifications: 125V, 165V, 250V, and 330V. Start capacitors above 20μF are always non-polarized aluminium
electrolytic capacitor An electrolyte is a substance that conducts electricity through the movement of ions, but not through the movement of electrons. This includes most soluble Salt (chemistry), salts, acids, and Base (chemistry), bases, dissolved in a polar solven ...
s with non solid electrolyte and therefore they are only applicable for the short motor starting time. The motor will not work properly if the
centrifugal switch A centrifugal switch is an electric switch that operates using the centrifugal force created from a rotating shaft, most commonly that of an electric motor or gasoline engine. The switch is designed to activate or de-activate as a function of t ...
is broken. If the switch is always open, the start capacitor is not part of the circuit, so the motor does not start. If the switch is always closed, the start capacitor is always in the circuit, so the motor windings will likely burn out. If a motor does not start, the capacitor is far more likely the problem than the switch.


Run capacitors

Some single-phase AC electric motors require a "run capacitor" to energize the second-phase winding (auxiliary coil) to create a rotating magnetic field while the motor is running. Run capacitors are designed for continuous duty while the motor is powered, which is why electrolytic capacitors are avoided, and low-loss polymer capacitors are used. Run capacitors are mostly polypropylene film capacitors (historically: metallised paper capacitors) and are energized the entire time the motor is running. Run capacitors are rated in a range of 1.5 to 100 μF, with volt classifications of 250, 370 and 440 V. If a wrong capacitance value is installed, it will cause an uneven magnetic field around the rotor. This causes the rotor to hesitate at the uneven spots, resulting in irregular rotation, especially under load. This hesitation can cause the motor to become noisy, increase energy consumption, cause performance to drop and the motor to overheat.


Dual run capacitors

A dual run capacitor supports two electric motors, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals, labeled ''C'' for common, ''FAN'', and ''HERM'' for hermetically-sealed compressor. Dual capacitors come in a variety of sizes, depending on the capacitance (measured in microfarads, μF), such as 40 plus 5μF, and also on the voltage. A 440-volt capacitor can be used in place of a 370-volt, but not a 370-volt in place of a 440-volt. The capacitance must remain within 5% of its original value. Round cylinder-shaped dual run capacitors are commonly used for
air conditioning Air conditioning, often abbreviated as A/C (US) or air con (UK), is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature, and in some cases, also controlling the humidity of internal air. Air c ...
, to help in the starting of the compressor and the condenser fan motor. An oval dual run capacitor could be used instead of a round capacitor; in either case the mounting strap needs to fit the shape used.


Labeling

The units of capacitance are labeled in microfarads (μF). Older capacitors may be labeled with the obsolete terms "mfd" or "MFD", which can be ambiguous but are, especially in this context, used for microfarad as well (a millifarad is 1000 microfarads and not usually seen on motors).


Failure modes

A faulty run capacitor often becomes swollen, with the sides or ends bowed or bulged out further than usual; it can then be clear to see that the capacitor has failed, because it is swollen or even blown apart causing the capacitor's
electrolyte An electrolyte is a substance that conducts electricity through the movement of ions, but not through the movement of electrons. This includes most soluble Salt (chemistry), salts, acids, and Base (chemistry), bases, dissolved in a polar solven ...
to leak out. Some capacitors have a "pressure-sensitive interrupter" design that causes them to fail before internal pressures can cause serious injury. One such design causes the top of the capacitor to expand and break internal wiring. Over many years of use the capacitance of the capacitor drops; this is known as a "weak capacitor". As a result, the motor may fail to start or to run at full power. When a motor is running during a lightning strike on the power grid, the run capacitor may be damaged or weakened by a voltage spike, thus requiring replacement.
IEC The International Electrotechnical Commission (IEC; ) is an international standards organization that prepares and publishes international standards for all electrical, electronic and related technologies. IEC standards cover a vast range of ...
/EN 60252-1 2011 specifies the following levels of protection for motor run capacitors: * S0 – no protection; * S1, S2 – fail open-circuit or short-circuit; * S3 – fail open-circuit only.


Safety issues


Heat

A motor capacitor which is a component of a
hot tub A hot tub is a large tub full of water used for hydrotherapy, relaxation or pleasure. Some have powerful jets for massage purposes. Hot tubs are sometimes also known as "spas" or by the trade name Jacuzzi. Hot tubs may be located outdoors or ...
circulating pump can overheat if defective. This poses a fire hazard, and the U.S. Consumer Product Safety Commission (CPSC) has received more than 100 reports of incidents of overheating of the motor capacitor, with some fires started."CPSC, Firms Announce Recall of Infinity and Lifestyle Spas" U.S. CPSC, Washington, DC, CPSC.gov, 2003-12-09, webpage
CP7
.


Toxicity

Motor capacitors manufactured before 1978 likely contain
polychlorinated biphenyls Polychlorinated biphenyls (PCBs) are organochlorine compounds with the formula C12 H10−''x'' Cl''x''; they were once widely used in the manufacture of carbonless copy paper, as heat transfer fluids, and as dielectric and coolant fluids f ...
(PCBs). These are extremely toxic and persistent chemicals with many long-lasting negative human and wildlife health effects. Capacitors were required to be labeled in the U.S. with "No PCBs" or similar language. Capacitors without these labels are suspect. PCB containing capacitors must be replaced and disposed by consulting local environmental authorities. If these capacitors leak or fail, PCBs can be released into the environment and will very likely result in extremely expensive environmental cleanups, and potentially, lawsuits. There are extensive toxicological reports on PCBs in the research community. U.S. EPA has much information on the correct way to test and manage these toxic chemicals in older capacitors.


References

{{Reflist


External links


Run Start Capacitors HVAC Motors



How to Check a Start Capacitor: 11 Steps (with Pictures)

What is the purpose of the Motor Run Capacitor?

Identification, Management, and Proper Disposal of PCB-Containing Electrical Equipment used in Mines
Electric motors Capacitors Heating, ventilation, and air conditioning