In
electrical engineering
Electrical engineering is an engineering discipline concerned with the study, design, and application of equipment, devices, and systems that use electricity, electronics, and electromagnetism. It emerged as an identifiable occupation in the l ...
and
mechanical engineering
Mechanical engineering is the study of physical machines and mechanism (engineering), mechanisms that may involve force and movement. It is an engineering branch that combines engineering physics and engineering mathematics, mathematics principl ...
, the power rating of equipment is the highest
power input allowed to flow through particular equipment. According to the particular discipline, the term ''power'' may refer to electrical or mechanical power. A power rating can also involve average and maximum power, which may vary depending on the kind of equipment and its application.
Power rating limits are usually set as a guideline by the manufacturers, protecting the equipment, and simplifying the design of larger systems, by providing a level of operation under which the equipment will not be damaged while allowing for a certain safety margin.
Equipment types
Dissipative equipment
In equipment that primarily dissipates
electric power
Electric power is the rate of transfer of electrical energy within a electric circuit, circuit. Its SI unit is the watt, the general unit of power (physics), power, defined as one joule per second. Standard prefixes apply to watts as with oth ...
or converts it into mechanical power, such as
resistor
A resistor is a passive two-terminal electronic component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active e ...
s, and
speakers, the power rating given is usually the maximum power that can be safely
dissipated by the equipment. The usual reason for this limit is
heat
In thermodynamics, heat is energy in transfer between a thermodynamic system and its surroundings by such mechanisms as thermal conduction, electromagnetic radiation, and friction, which are microscopic in nature, involving sub-atomic, ato ...
, although in certain
electromechanical
Electromechanics combine processes and procedures drawn from electrical engineering and mechanical engineering. Electromechanics focus on the interaction of electrical and mechanical systems as a whole and how the two systems interact with each ...
devices, particularly speakers, it is to prevent mechanical damage. When heat is the limiting factor, the power rating is easily calculated. First, the amount of heat that can be safely dissipated by the device,
, must be calculated. This is related to the maximum safe operating
temperature
Temperature is a physical quantity that quantitatively expresses the attribute of hotness or coldness. Temperature is measurement, measured with a thermometer. It reflects the average kinetic energy of the vibrating and colliding atoms making ...
, the ambient temperature or temperature range in which the device will be operated, and the method of
cooling
Cooling is removal of heat, usually resulting in a lower temperature and/or Phase transition, phase change. Temperature lowering achieved by any other means may also be called cooling.
The Heat transfer, transfer of Internal energy, thermal energ ...
. If
is the maximum safe
operating temperature
An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the de ...
of the device,
is the ambient temperature, and
is the total
thermal resistance between the device and ambient, then the maximum heat dissipation is given by
:
If all power in a device is dissipated as heat, then this is also the power rating.
Mechanical equipment
Equipment is generally rated by the power it will deliver, for example, at the shaft of an electric or hydraulic motor. The power input to the equipment will be greater owing to the less than 100% efficiency of the device.
Efficiency of a device is often defined as the ratio of output power to the sum of output power and losses. In some types of equipment, it is possible to measure or calculate losses directly. This allows efficiency to be calculated with greater precision than the quotient of input power over output power, where relatively small measurement uncertainty will greatly affect the resulting calculated efficiency.
Power converting equipment
In devices that primarily
convert between different forms of electric power, such as
transformer
In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple Electrical network, circuits. A varying current in any coil of the transformer produces ...
s, or transport it from one location to another, such as
transmission line
In electrical engineering, a transmission line is a specialized cable or other structure designed to conduct electromagnetic waves in a contained manner. The term applies when the conductors are long enough that the wave nature of the transmis ...
s, the power rating almost always refers to the maximum power flow through the device, not dissipation within it. The usual reason for the limit is heat, and the maximum heat dissipation is calculated as above.
Power ratings are usually given in
watt
The watt (symbol: W) is the unit of Power (physics), power or radiant flux in the International System of Units (SI), equal to 1 joule per second or 1 kg⋅m2⋅s−3. It is used to quantification (science), quantify the rate of Work ...
s for
real power and
volt-ampere
The volt-ampere ( SI symbol: VA, sometimes V⋅A or V A) is the unit of measurement for apparent power in an electrical circuit. It is the product of the root mean square voltage (in volts) and the root mean square current (in ampere ...
s for
apparent power
In an electric circuit, instantaneous power is the time rate of flow of energy past a given point of the circuit. In alternating current circuits, energy storage elements such as inductors and capacitors may result in periodic reversals of the d ...
, although for devices intended for use in large power systems, both may be given in a
per-unit system. Cables are usually rated by giving their maximum voltage and their
ampacity
Ampacity is a portmanteau for ''ampere capacity'', defined by United States National Electrical Codes. Ampacity is defined as the maximum current, in amperes, that a conductor can carry continuously under the conditions of use without exceeding ...
.
As the power rating depends on the method of cooling, different ratings may be specified for air cooling, water cooling, etc.
Average vs. maximum
For AC-operated devices (e.g.
coaxial cable
Coaxial cable, or coax (pronounced ), is a type of electrical cable consisting of an inner Electrical conductor, conductor surrounded by a concentric conducting Electromagnetic shielding, shield, with the two separated by a dielectric (Insulat ...
,
loudspeakers
A loudspeaker (commonly referred to as a speaker or, more fully, a speaker system) is a combination of one or more speaker drivers, an enclosure, and electrical connections (possibly including a crossover network). The speaker driver is an ...
), there may even be two power ratings, a maximum (peak) power rating and an average power rating.
For such devices, the peak power rating usually specifies the low frequency or pulse energy, while the average power rating limits high-frequency operation.
Average power calculation rating depends on some assumptions about how the device is going to be used. For example, the
EIA rating method for loudspeakers uses a shaped noise signal that simulates music and allows peak excursion of 6 dB, so an EIA rating of 50 Watts corresponds to 200 Watts peak rating.
Maximum continuous rating
Maximum continuous rating (MCR) is defined as the maximum output (MW) that an electric power generating station is capable of producing continuously under normal conditions over a year. Under ideal conditions, the actual output could be higher than the MCR.
Within
shipping
Freight transport, also referred to as freight forwarding, is the physical process of transporting commodities and merchandise goods and cargo. The term shipping originally referred to transport by sea but in American English, it has been ...
, ships usually operate at the nominal continuous rating (NCR) which is 85% of the 90% of MCR. The 90% MCR is usually the contractual output for which the propeller is designed. Thus, the usual output at which ships are operated is around 75% to 77% of MCR.
Other definitions
In some fields of engineering, even a more complex set of power ratings is used. For example,
helicopter engines are rated for continuous power (which does not have a time constraint), takeoff and hover power rating (defined as half to one-hour operation), maximum
contingency power (which can be sustained for two-three minutes), and emergency (half a minute) power rating.
For electrical motors, a similar kind of information is conveyed by the ''service factor'', which is a multiplier that, when applied to the rated output power, gives the power level a motor can sustain for shorter periods of time. The service factor is typically in the 1.15-1.4 range, with the figure being lower for higher-power motors. For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its
service life is reduced to less than half for continued operation at this level.
The service factor is defined in the
ANSI
The American National Standards Institute (ANSI ) is a private nonprofit organization that oversees the development of voluntary consensus standards for products, services, processes, systems, and personnel in the United States. The organiz ...
/NEMA
MG 1 standard,
and is generally used in the United States.
There is no
IEC standard for the service factor.
Exceeding the power rating of a device by more than the margin of safety set by the manufacturer usually does damage to the device by causing its operating temperature to exceed safe levels. In
semiconductor
A semiconductor is a material with electrical conductivity between that of a conductor and an insulator. Its conductivity can be modified by adding impurities (" doping") to its crystal structure. When two regions with different doping level ...
s, irreparable damage can occur very quickly. Exceeding the power rating of most devices for a very short period of time is not harmful, although doing so regularly can sometimes cause cumulative damage.
Power ratings for electrical apparatus and transmission lines are a function of the duration of the proposed load and the ambient temperature; a transmission line or transformer, for example, can carry significantly more load in cold weather than in hot weather. Momentary overloads, causing high temperatures and deterioration of insulation, may be considered an acceptable trade-off in emergency situations. The power rating of switching devices varies depending on the circuit voltage as well as the current. In certain aerospace or military applications, a device may carry a much higher rating than would be accepted in devices intended to operate for long service life.
Examples
Audio amplifiers
Audio amplifier
An audio power amplifier (or power amp) electronic amplifier, amplifies low-power electronic audio signals, such as the signal from a radio receiver or an electric guitar pickup (music technology), pickup, to a level that is high enough for dr ...
power ratings are typically established by driving the device under test to the onset of
clipping, to a predetermined distortion level, variable per manufacturer or per product line. Driving an amplifier to 1% distortion levels will yield a higher rating than driving it to 0.01% distortion levels.
[Quilter, Patrick (2004)]
"How to Compare Amplifier Power Ratings."
''Sound and Song''. Retrieveded on March 18, 2010. Similarly, testing an amplifier at a single mid-range frequency, or testing just one channel of a two-channel amplifier, will yield a higher rating than if it is tested throughout its intended frequency range with both channels working. Manufacturers can use these methods to market amplifiers whose published maximum power output includes some amount of clipping in order to show higher numbers.
For instance, the
Federal Trade Commission
The Federal Trade Commission (FTC) is an independent agency of the United States government whose principal mission is the enforcement of civil (non-criminal) United States antitrust law, antitrust law and the promotion of consumer protection. It ...
(FTC) established an amplifier rating system in which the device is tested with both channels driven throughout its advertised frequency range, at no more than its published distortion level. The
Electronic Industries Association (EIA) rating system, however, determines amplifier power by measuring a single channel at 1,000 Hz, with a 1% distortion level—1% clipping. Using the EIA method rates an amplifier 10 to 20% higher than the FTC method.
[
]
Photovoltaic modules
The nominal power of a photovoltaic module is determined by measuring current and voltage while varying resistance under defined illumination. The conditions are specified in standards such as IEC 61215, IEC 61646 and UL 1703; specifically, the light intensity is 1000 W/m2, with a spectrum similar to sunlight hitting the Earth's surface at latitude 35° N in the summer ( airmass 1.5) and temperature of the cells at 25 °C. The power is measured while varying the resistive load on the module between open and closed circuit.
The maximum power measured is the nominal power of the module in Watts. Colloquially, this is also written as "Wp"; this format is colloquial as it is outside the standard by adding suffixes to standardized units. The nominal power divided by the light power that falls on the module (area x 1000 W/m2) is the ''efficiency''.
See also
* Effective radiated power, the regulatory analog for VHF, UHF and FM broadcasting
References
{{DEFAULTSORT:Power Rating
Electrical parameters
Electric power