Chemical Shift Anisotropy
   HOME

TheInfoList



OR:

In
nuclear magnetic resonance Nuclear magnetic resonance (NMR) is a physical phenomenon in which nuclei in a strong constant magnetic field are perturbed by a weak oscillating magnetic field (in the near field) and respond by producing an electromagnetic signal with a ...
(NMR) spectroscopy, the chemical shift is the
resonant frequency Resonance describes the phenomenon of increased amplitude that occurs when the frequency of an applied periodic force (or a Fourier component of it) is equal or close to a natural frequency of the system on which it acts. When an oscillatin ...
of an
atomic nucleus The atomic nucleus is the small, dense region consisting of protons and neutrons at the center of an atom, discovered in 1911 by Ernest Rutherford based on the 1909 Geiger–Marsden gold foil experiment. After the discovery of the neutron i ...
relative to a standard in a
magnetic field A magnetic field is a vector field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular to its own velocity and to ...
. Often the position and number of chemical shifts are diagnostic of the structure of a
molecule A molecule is a group of two or more atoms held together by attractive forces known as chemical bonds; depending on context, the term may or may not include ions which satisfy this criterion. In quantum physics, organic chemistry, and bioch ...
. Chemical shifts are also used to describe signals in other forms of spectroscopy such as
photoemission spectroscopy Photoemission spectroscopy (PES), also known as photoelectron spectroscopy, refers to energy measurement of electrons emitted from solids, gases or liquids by the photoelectric effect, in order to determine the binding energies of electrons in th ...
. Some atomic nuclei possess a
magnetic moment In electromagnetism, the magnetic moment is the magnetic strength and orientation of a magnet or other object that produces a magnetic field. Examples of objects that have magnetic moments include loops of electric current (such as electromagnets ...
(
nuclear spin In atomic physics, the spin quantum number is a quantum number (designated ) which describes the intrinsic angular momentum (or spin angular momentum, or simply spin) of an electron or other particle. The phrase was originally used to describe th ...
), which gives rise to different
energy level A quantum mechanical system or particle that is bound—that is, confined spatially—can only take on certain discrete values of energy, called energy levels. This contrasts with classical particles, which can have any amount of energy. The te ...
s and resonance frequencies in a magnetic field. The total magnetic field experienced by a nucleus includes local magnetic fields induced by currents of electrons in the
molecular orbital In chemistry, a molecular orbital is a mathematical function describing the location and wave-like behavior of an electron in a molecule. This function can be used to calculate chemical and physical properties such as the probability of finding ...
s (note that electrons have a magnetic moment themselves). The electron distribution of the same type of nucleus (e.g. ) usually varies according to the local geometry (binding partners,
bond length In molecular geometry, bond length or bond distance is defined as the average distance between nuclei of two bonded atoms in a molecule. It is a transferable property of a bond between atoms of fixed types, relatively independent of the rest of ...
s, angles between bonds, and so on), and with it the local magnetic field at each nucleus. This is reflected in the spin energy levels (and resonance frequencies). The variations of nuclear magnetic resonance frequencies of the same kind of nucleus, due to variations in the electron distribution, is called the chemical shift. The size of the chemical shift is given with respect to a reference frequency or reference sample (see also chemical shift referencing), usually a molecule with a barely distorted electron distribution.


Operating frequency

The operating (or Larmor) frequency of a magnet is calculated from the
Larmor equation In physics, Larmor precession (named after Joseph Larmor) is the precession of the magnetic moment of an object about an external magnetic field. The phenomenon is conceptually similar to the precession of a tilted classical gyroscope in an extern ...
: \omega_ = \gamma B_0\,, where is the actual strength of the magnet in units like Teslas or
Gauss Johann Carl Friedrich Gauss (; german: Gauß ; la, Carolus Fridericus Gauss; 30 April 177723 February 1855) was a German mathematician and physicist who made significant contributions to many fields in mathematics and science. Sometimes refer ...
, and is the
gyromagnetic ratio In physics, the gyromagnetic ratio (also sometimes known as the magnetogyric ratio in other disciplines) of a particle or system is the ratio of its magnetic moment to its angular momentum, and it is often denoted by the symbol , gamma. Its SI u ...
of the nucleus being tested which is in turn calculated from its
magnetic moment In electromagnetism, the magnetic moment is the magnetic strength and orientation of a magnet or other object that produces a magnetic field. Examples of objects that have magnetic moments include loops of electric current (such as electromagnets ...
and
spin number In atomic physics, the spin quantum number is a quantum number (designated ) which describes the intrinsic angular momentum (or spin angular momentum, or simply spin) of an electron or other particle. The phrase was originally used to describe ...
with the
nuclear magneton The nuclear magneton (symbol ''μ'') is a physical constant of magnetic moment, defined in SI units by: :\mu_\text = and in Gaussian CGS units by: :\mu_\text = where: :''e'' is the elementary charge, :''ħ'' is the reduced Planck constant ...
and the
Planck constant The Planck constant, or Planck's constant, is a fundamental physical constant of foundational importance in quantum mechanics. The constant gives the relationship between the energy of a photon and its frequency, and by the mass-energy equivale ...
: : \gamma = \frac\,. Thus for example, the proton operating frequency for a 1  T magnet is calculated as: : \omega _0 = \gamma B_0 = \frac \times 1\, = 42.5\,\,. MRI scanners are often referred to by their field strengths (e.g. "a 7 T scanner"), whereas NMR spectrometers are commonly referred to by the corresponding proton Larmor frequency (e.g. "a 300 MHz spectrometer", which has a of 7 T ). While chemical shift is referenced in order that the units are equivalent across different field strengths, the actual frequency separation in
Hertz The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), equivalent to one event (or cycle) per second. The hertz is an SI derived unit whose expression in terms of SI base units is s−1, meaning that on ...
scales with field strength (). As a result, the difference of chemical shift between two signals (ppm) represents a larger number of
Hertz The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), equivalent to one event (or cycle) per second. The hertz is an SI derived unit whose expression in terms of SI base units is s−1, meaning that on ...
on machines that have larger and therefore the signals are less likely to be overlapping in the resulting spectrum. This increased resolution is a significant advantage for analysis. (Larger field machines are also favoured on account of having intrinsically higher signal arising from the
Boltzmann distribution In statistical mechanics and mathematics, a Boltzmann distribution (also called Gibbs distribution Translated by J.B. Sykes and M.J. Kearsley. See section 28) is a probability distribution or probability measure that gives the probability t ...
of magnetic spin states.)


Chemical shift referencing

Chemical shift is usually expressed in
parts per million In science and engineering, the parts-per notation is a set of pseudo-units to describe small values of miscellaneous dimensionless quantities, e.g. mole fraction or mass fraction. Since these fractions are quantity-per-quantity measures, they ...
(ppm) by
frequency Frequency is the number of occurrences of a repeating event per unit of time. It is also occasionally referred to as ''temporal frequency'' for clarity, and is distinct from ''angular frequency''. Frequency is measured in hertz (Hz) which is eq ...
, because it is calculated from: : \delta = \frac\,, where is the absolute resonance frequency of the sample and is the absolute resonance frequency of a standard reference compound, measured in the same applied magnetic field . Since the numerator is usually expressed in
hertz The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), equivalent to one event (or cycle) per second. The hertz is an SI derived unit whose expression in terms of SI base units is s−1, meaning that on ...
, and the denominator in
megahertz The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), equivalent to one event (or Cycle per second, cycle) per second. The hertz is an SI derived unit whose expression in terms of SI base units is s−1, me ...
, is expressed in ppm. The detected frequencies (in Hz) for 1H, 13C, and 29Si nuclei are usually referenced against TMS (
tetramethylsilane Tetramethylsilane (abbreviated as TMS) is the organosilicon compound with the formula Si(CH3)4. It is the simplest tetraorganosilane. Like all silanes, the TMS framework is tetrahedral. TMS is a building block in organometallic chemistry but also ...
), TSP (
Trimethylsilylpropanoic acid Trimethylsilylpropanoic acid (TMSP or TSP) is a chemical compound containing a trimethylsilyl group. It is used as internal reference in nuclear magnetic resonance Nuclear magnetic resonance (NMR) is a physical phenomenon in which nuclei ...
), or DSS, which by the definition above have a chemical shift of zero if chosen as the reference. Other standard materials are used for setting the chemical shift for other nuclei. Thus, an NMR signal observed at a frequency 300 Hz higher than the signal from TMS, where the TMS resonance frequency is 300 MHz, has a chemical shift of: :\frac=1\times10^= 1\,\rm ppm \,. Although the absolute resonance frequency depends on the applied magnetic field, the chemical shift is independent of external magnetic field strength. On the other hand, the resolution of NMR will increase with applied magnetic field.


Referencing methods

Practically speaking, diverse methods may be used to reference chemical shifts in an NMR experiment, which can be subdivided into ''indirect'' and ''direct'' referencing methods. Indirect referencing uses a channel other than the one of interest to adjust chemical shift scale correctly, i.e. the solvent signal in the deuterium (lock) channel can be used to reference the a 1H NMR spectrum. Both indirect and direct referencing can be done as three different procedures: # "Internal referencing, where the reference compound is added directly to the system under study." In this common practice, users adjust residual solvent signals of 1H or 13C NMR spectra with calibrated spectral tables. If substances other than the solvent itself are used for internal referencing, the sample has to be combined with the reference compound, which may affect the chemical shifts. # "External referencing, involving sample and reference contained separately in coaxial cylindrical tubes." With this procedure, the reference signal is still visible in the spectrum of interest, although the reference and the sample are physically separated by a glass wall. Magnetic susceptibility differences between the sample and the reference phase need to be corrected theoretically, which lowers the practicality of this procedure. # "Substitution method: The use of separate cylindrical tubes for the sample and the reference compound, with (in principle) spectra recorded individually for each." Similar to external referencing, this method allows referencing without sample contamination. If field/frequency locking via the 2H signal of the deutarated solvent is used and the solvents of reference and analyte are the same, the use of this methods is straightforward. Problems may arise if different solvents are used for the reference compound and the sample as (just like for external referencing) magnetic susceptibility differences need to be corrected theoretically. If this method is used without field/frequency locking, shimming procedures between the sample and the reference need to be avoided as they change the applied magnetic field (and thereby influence the chemical shift). Modern NMR spectrometers commonly make use of the absolute scale, which defines the 1H signal of TMS as 0 ppm in proton NMR and the center frequencies of all other nuclei as percentage of the TMS resonance frequency: \Xi %= 100 (\upsilon^_X / \upsilon^_) The use of the deuterium (lock) channel, so the 2H signal of the deuterated solvent, and the Ξ value of the absolute scale is a form of internal referencing and is particularly useful in heteronuclear NMR spectroscopy as local reference compounds may not be always be available or easily used (i.e. liquid NH3 for 15N NMR spectroscopy). This system, however, relies on accurately determined 2H NMR chemical shifts enlisted in the spectrometer software and correctly determined Ξ values by IUPAC. A recent study for 19F NMR spectroscopy revealed that the use of the absolute scale and lock-based internal referencing led to errors in chemical shifts. These may be negated by inclusion of calibrated reference compounds.


The induced magnetic field

The electrons around a nucleus will circulate in a magnetic field and create a secondary
induced magnetic field In classical electromagnetism, magnetization is the vector field that expresses the density of permanent or induced magnetic dipole moments in a magnetic material. Movement within this field is described by direction and is either Axial or Dia ...
. This field opposes the applied field as stipulated by
Lenz's law Lenz's law states that the direction of the electric current induced in a conductor by a changing magnetic field is such that the magnetic field created by the induced current opposes changes in the initial magnetic field. It is named after p ...
and atoms with higher induced fields (i.e., higher electron density) are therefore called ''shielded'', relative to those with lower electron density. Electron-donating alkyl groups, for example, lead to increased shielding whereas
electron-withdrawing substituent In chemistry, an electron-withdrawing group (EWG) is a substituent that has some of the following kinetic and thermodynamic implications: *with regards to electron transfer, electron-withdrawing groups enhance the oxidizing power tendency of t ...
s such as nitro groups lead to ''deshielding'' of the nucleus. Not only substituents cause local induced fields. Bonding electrons can also lead to shielding and deshielding effects. A striking example of this is the
pi bonds In chemistry, pi bonds (π bonds) are covalent chemical bonds, in each of which two lobes of an orbital on one atom overlap with two lobes of an orbital on another atom, and in which this overlap occurs laterally. Each of these atomic orbital ...
in
benzene Benzene is an organic chemical compound with the molecular formula C6H6. The benzene molecule is composed of six carbon atoms joined in a planar ring with one hydrogen atom attached to each. Because it contains only carbon and hydrogen atoms, ...
. Circular current through the hyperconjugated system causes a shielding effect at the molecule's center and a deshielding effect at its edges. Trends in chemical shift are explained based on the degree of shielding or deshielding. Nuclei are found to resonate in a wide range to the left (or more rare to the right) of the internal standard. When a signal is found with a higher chemical shift: * the applied effective magnetic field is lower, if the resonance frequency is fixed (as in old traditional CW spectrometers) * the frequency is higher, when the applied magnetic field is static (normal case in FT spectrometers) * the nucleus is more deshielded * the signal or shift is downfield or at low field or paramagnetic Conversely a lower chemical shift is called a diamagnetic shift, and is upfield and more shielded.


Diamagnetic shielding

In real molecules protons are surrounded by a cloud of charge due to adjacent bonds and atoms. In an applied magnetic field () electrons circulate and produce an induced field () which opposes the applied field. The effective field at the nucleus will be . The nucleus is said to be experiencing a diamagnetic shielding.


Factors causing chemical shifts

Important factors influencing chemical shift are electron density,
electronegativity Electronegativity, symbolized as , is the tendency for an atom of a given chemical element to attract shared electrons (or electron density) when forming a chemical bond. An atom's electronegativity is affected by both its atomic number and the d ...
of neighboring groups and anisotropic induced magnetic field effects. Electron density shields a nucleus from the external field. For example, in proton NMR the electron-poor
tropylium In organic chemistry, the tropylium ion or cycloheptatrienyl cation is an aromatic species with a formula of 7H7sup>+. Its name derives from the molecule tropine from which cycloheptatriene (tropylidene) was first synthesized in 1881. Salts of ...
ion has its protons downfield at 9.17 ppm, those of the electron-rich
cyclooctatetraenyl 1,3,5,7-Cyclooctatetraene (COT) is an unsaturated derivative of cyclooctane, with the formula C8H8. It is also known as nnulene. This polyunsaturated hydrocarbon is a colorless to light yellow flammable liquid at room temperature. Because of ...
anion move upfield to 6.75 ppm and its dianion even more upfield to 5.56 ppm. A nucleus in the vicinity of an
electronegative Electronegativity, symbolized as , is the tendency for an atom of a given chemical element to attract shared electrons (or electron density) when forming a chemical bond. An atom's electronegativity is affected by both its atomic number and the d ...
atom experiences reduced electron density and the nucleus is therefore deshielded. In
proton NMR Proton nuclear magnetic resonance (proton NMR, hydrogen-1 NMR, or 1H NMR) is the application of nuclear magnetic resonance in NMR spectroscopy with respect to hydrogen-1 nuclei within the molecules of a substance, in order to determine the struc ...
of methyl halides (CH3X) the chemical shift of the methyl protons increase in the order from 2.16 ppm to 4.26 ppm reflecting this trend. In
carbon NMR Carbon-13 (C13) nuclear magnetic resonance (most commonly known as carbon-13 NMR spectroscopy or 13C NMR spectroscopy or sometimes simply referred to as carbon NMR) is the application of nuclear magnetic resonance (NMR) spectroscopy to carbon. It is ...
the chemical shift of the carbon nuclei increase in the same order from around −10 ppm to 70 ppm. Also when the electronegative atom is removed further away the effect diminishes until it can be observed no longer.
Anisotropic Anisotropy () is the property of a material which allows it to change or assume different properties in different directions, as opposed to isotropy. It can be defined as a difference, when measured along different axes, in a material's physic ...
induced magnetic field effects are the result of a local induced magnetic field experienced by a nucleus resulting from circulating electrons that can either be paramagnetic when it is parallel to the applied field or diamagnetic when it is opposed to it. It is observed in
alkene In organic chemistry, an alkene is a hydrocarbon containing a carbon–carbon double bond. Alkene is often used as synonym of olefin, that is, any hydrocarbon containing one or more double bonds.H. Stephen Stoker (2015): General, Organic, an ...
s where the double bond is oriented perpendicular to the external field with pi electrons likewise circulating at right angles. The induced magnetic field lines are parallel to the external field at the location of the alkene protons which therefore shift downfield to a 4.5 ppm to 7.5 ppm range. The three-dimensional space where a diamagnetic shift is called the shielding zone with a cone-like shape aligned with the external field. : The protons in
aromatic In chemistry, aromaticity is a chemical property of cyclic ( ring-shaped), ''typically'' planar (flat) molecular structures with pi bonds in resonance (those containing delocalized electrons) that gives increased stability compared to satur ...
compounds are shifted downfield even further with a signal for
benzene Benzene is an organic chemical compound with the molecular formula C6H6. The benzene molecule is composed of six carbon atoms joined in a planar ring with one hydrogen atom attached to each. Because it contains only carbon and hydrogen atoms, ...
at 7.73 ppm as a consequence of a
diamagnetic ring current An aromatic ring current is an effect observed in aromatic molecules such as benzene and naphthalene. If a magnetic field is directed perpendicular to the plane of the aromatic system, a ring current is induced in the delocalized π electrons ...
.
Alkyne \ce \ce Acetylene \ce \ce \ce Propyne \ce \ce \ce \ce 1-Butyne In organic chemistry, an alkyne is an unsaturated hydrocarbon containing at least one carbon—carbon triple bond. The simplest acyclic alkynes with only one triple bond and n ...
protons by contrast resonate at high field in a 2–3 ppm range. For alkynes the most effective orientation is the external field in parallel with electrons circulation around the triple bond. In this way the acetylenic protons are located in the cone-shaped shielding zone hence the upfield shift. :


Magnetic properties of most common nuclei

1H and 13C are not the only nuclei susceptible to NMR experiments. A number of different nuclei can also be detected, although the use of such techniques is generally rare due to small relative sensitivities in NMR experiments (compared to 1H) of the nuclei in question, the other factor for rare use being their slender representation in nature and organic compounds. 1H, 13C, 15N, 19F and 31P are the five nuclei that have the greatest importance in NMR experiments: * 1H because of high sensitivity and vast occurrence in organic compounds * 13C because of being the key component of all organic compounds despite occurring at a low abundance (1.1%) compared to the major isotope of carbon 12C, which has a spin of 0 and therefore is NMR-inactive. * 15N because of being a key component of important biomolecules such as
protein Proteins are large biomolecules and macromolecules that comprise one or more long chains of amino acid residues. Proteins perform a vast array of functions within organisms, including catalysing metabolic reactions, DNA replication, respo ...
s and DNA * 19F because of high relative sensitivity * 31P because of frequent occurrence in organic compounds and moderate relative sensitivity


Chemical shift manipulation

In general, the associated increased signal-to-noise and resolution has driven a move towards increasingly high field strengths. In limited cases, however, lower fields are preferred; examples are for systems in chemical exchange, where the speed of the exchange relative to the NMR experiment can cause additional and confounding linewidth broadening. Similarly, while avoidance of second order coupling is generally preferred, this information can be useful for elucidation of chemical structures. Using refocussing pulses placed between recording of successive points of the
free induction decay In Fourier transform nuclear magnetic resonance spectroscopy, free induction decay (FID) is the observable NMR signal generated by non-equilibrium nuclear spin magnetization precessing about the magnetic field (conventionally along z). This non-e ...
, in an analogous fashion to the
spin echo In magnetic resonance, a spin echo or Hahn echo is the refocusing of spin magnetisation by a pulse of resonant electromagnetic radiation. Modern nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) make use of this effect. The NMR ...
technique in MRI, the chemical shift evolution can be scaled to provide apparent low-field spectra on a high-field spectrometer. In a similar fashion, it is possible to upscale the effect of J-coupling relative to the chemical shift using pulse sequences that include additional J-coupling evolution periods interspersed with conventional spin evolutions.


Other chemical shifts

The
Knight shift The Knight shift is a shift in the nuclear magnetic resonance (NMR) frequency of a paramagnetic substance first published in 1949 by the UC Berkeley physicist Walter D. Knight. For an ensemble of ''N'' spins in a magnetic induction field \vec, t ...
(first reported in 1949) and Shoolery's rule are observed with pure metals and methylene groups, respectively. The NMR chemical shift in its present-day meaning first appeared in journals in 1950. Chemical shifts with a different meaning appear in
X-ray photoelectron spectroscopy X-ray photoelectron spectroscopy (XPS) is a surface-sensitive quantitative spectroscopic technique based on the photoelectric effect that can identify the elements that exist within a material (elemental composition) or are covering its surface, ...
as the shift in atomic core-level energy due to a specific chemical environment. The term is also used in
Mössbauer spectroscopy Mössbauer spectroscopy is a spectroscopic technique based on the Mössbauer effect. This effect, discovered by Rudolf Mössbauer (sometimes written "Moessbauer", German: "Mößbauer") in 1958, consists of the nearly recoil-free emission and abso ...
, where similarly to NMR it refers to a shift in peak position due to the local chemical bonding environment. As is the case for NMR the chemical shift reflects the electron density at the atomic nucleus.


See also

* EuFOD, a shift agent *
MRI Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to form pictures of the anatomy and the physiological processes of the body. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves ...
*
Nuclear magnetic resonance Nuclear magnetic resonance (NMR) is a physical phenomenon in which nuclei in a strong constant magnetic field are perturbed by a weak oscillating magnetic field (in the near field) and respond by producing an electromagnetic signal with a ...
*
Nuclear magnetic resonance spectroscopy of carbohydrates Carbohydrate NMR spectroscopy is the application of nuclear magnetic resonance (NMR) spectroscopy to structural and conformational analysis of carbohydrates. This method allows the scientists to elucidate structure of monosaccharides, oligosacchari ...
* Nuclear magnetic resonance spectroscopy of nucleic acids *
Nuclear magnetic resonance spectroscopy of proteins Nuclear magnetic resonance spectroscopy of proteins (usually abbreviated protein NMR) is a field of structural biology in which NMR spectroscopy is used to obtain information about the structure and dynamics of proteins, and also nucleic acids, and ...
*
Protein NMR Nuclear magnetic resonance spectroscopy of proteins (usually abbreviated protein NMR) is a field of structural biology in which NMR spectroscopy is used to obtain information about the structure and dynamics of proteins, and also nucleic acids, and ...
*
Random coil index Random coil index (RCI) predicts protein flexibility by calculating an inverse weighted average of backbone secondary chemical shifts and predicting values of model-free order parameters as well as per-residue RMSD of NMR and molecular dynamics ...
*
Relaxation (NMR) In MRI and NMR spectroscopy, an observable nuclear spin polarization ( magnetization) is created by a homogeneous magnetic field. This field makes the magnetic dipole moments of the sample precess at the resonance ( Larmor) frequency of the nuclei ...
*
Solid-state NMR Solid-state NMR (ssNMR) spectroscopy is a technique for characterizing atomic level structure in solid materials e.g. powders, single crystals and amorphous samples and tissues using nuclear magnetic resonance (NMR) spectroscopy. The anisotropic pa ...
*
TRISPHAT TRISPHAT (full name tris(tetrachlorocatecholato)phosphate(1−)) is an inorganic anion with the formula often prepared as the tributylammonium () or tetrabutylammonium ( salt. The anion features phosphorus(V) bonded to three tetrachlorocatecholate ...
, a chiral shift reagent for cations *
Zeeman effect The Zeeman effect (; ) is the effect of splitting of a spectral line into several components in the presence of a static magnetic field. It is named after the Dutch physicist Pieter Zeeman, who discovered it in 1896 and received a Nobel prize ...


References


External links


chem.wisc.eduBioMagResBankNMR Table
* Online tutorials (these generally involve combined use of IR, 1H NMR, 13C NMR and
mass spectrometry Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a ''mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is use ...
)
Problem set 1
(see also thi

for more background information on spin-spin coupling)