Train Communication Network
   HOME

TheInfoList



OR:

The train communication network (TCN) is a hierarchical combination of two
fieldbus Fieldbus is the name of a family of industrial computer networks used for real-time distributed control. Fieldbus profiles are standardized by the International Electrotechnical Commission (IEC) as IEC 61784/61158. A complex automated industrial ...
for data transmission within trains. It consists of the Multifunction Vehicle Bus (MVB) inside each vehicle and of the Wire Train Bus (WTB) to connect the different vehicles. The TCN components have been standardized in IEC 61375.


Multifunction vehicle bus (MVB)

The multifunction vehicle bus connects individual nodes within a vehicle or in a closed train set. Unlike the WTB there is no requirement on a single international connector standard for the vehicle bus inside a coach, locomotive or train set – instead there are three predefined media and connector classes: # OGF ( optical glass fibres) uses 240 μm fibers for a line distance of 2000 m, # EMD (electrical medium distance) uses shielded twisted pair with RS 485 transmitters and transformers for galvanical isolation), for a length reaching 200 m and # ESD (electrical short distance) uses a simple backplane wiring without galvanic isolation, for which case the cable may be up to 20 m in length. The plugs and sockets are the same as used by Profibus (with two 9-pin Sub-D sockets per electrical device). For OGF, the media sources are connected by repeaters (signal generators) being joined on a central star coupler  A repeater is also used for the transition from one medium to another. There is no inauguration, the addresses are statically allocated. The number of addressable devices depends on the configuration of the vehicle bus – there may be up to 4095 simple sensors/ actuators (Class I) and up to 255 programmable stations (Class 2, with configuration slots). The physical level is using transmissions at a 1.5 Mbit/s data rate using Manchester II encoding. The maximum distance is determined on the restriction of a maximum allowed reply delay of 42.7 µs (where for longer distances a second mode is used that allows up to 83.4 μs with reduced throughput, in case MVB is used for switchgear on the track side) while most system parts communicate with a response time of a typical 10µs.


History

MVB was derived from the P215 bus developed by Brown Boveri Cie,
Switzerland ). Swiss law does not designate a ''capital'' as such, but the federal parliament and government are installed in Bern, while other federal institutions, such as the federal courts, are in other cities (Bellinzona, Lausanne, Luzern, Neuchâtel ...
(now ABB), incorporating the publisher/subscriber principle from early field busses ( DATRAS). Back in 1984,
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including ...
defined the requirement specifications for busses to be used in electrical substation in collaboration with IEC SC65C. MVB presents many similarities with the FIP field bus (originally from French "''Flux d'Information vers le Processus''", relabeled as Factory Instrumentation Protocol or some references also use the hybrid "Flux Information Protocol") that was developed in the French NFC 46602 standard series. Since both stemmed from the same
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including ...
specifications. This explains why MVB and FIP have similar operation (cyclic and event-driven), only the arbitration method in case of multiple access differs, as MVB used a binary bisection mode relying of collision detection while FIP piggy-backed a "look-at-me" bit over periodic data. Efforts to merge FIP and MVB failed at the stubbornness of the two parties. MVB, Profibus and WorldFIP were proposed as a substation bus in
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including ...
, but to avoid parallel solutions,
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including ...
decided that none will be used and favored
Ethernet Ethernet () is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 198 ...
as a common denominator. The MVB frames are not compatible with IEC 61158-2 fieldbus frames as it omits most of the preamble synchronization (which is not required if zero-crossing detection is possible). The paradox situation is that the IEC 61158 field bus and MVB physical layer were developed by the same persons in
IEC TC 57 IEC Technical Committee 57 is one of the technical committees of the International Electrotechnical Commission (IEC). TC 57 is responsible for development of standards for information exchange for power systems and other related systems including ...
. The difference came from the
fieldbus Fieldbus is the name of a family of industrial computer networks used for real-time distributed control. Fieldbus profiles are standardized by the International Electrotechnical Commission (IEC) as IEC 61784/61158. A complex automated industrial ...
physical layer In the seven-layer OSI model of computer networking, the physical layer or layer 1 is the first and lowest layer; The layer most closely associated with the physical connection between devices. This layer may be implemented by a PHY chip. The ...
which assumes a phase-locked loop to decode the Manchester data, requiring a preamble to synthonize the decoder, while MVB operated principally with optical fibres where this method is useless, MVB's decoding relies on zero-crossing detectors and Manchester pattern recognition. However most of the modern development and test equipment can equally communicate WTB/MVB frames as well as Profibus frames on the line as the telegram structure similar to Profibus. The WorldFIP connectors found usage in train equipment in
France France (), officially the French Republic ( ), is a country primarily located in Western Europe. It also comprises of Overseas France, overseas regions and territories in the Americas and the Atlantic Ocean, Atlantic, Pacific Ocean, Pac ...
and
North America North America is a continent in the Northern Hemisphere and almost entirely within the Western Hemisphere. It is bordered to the north by the Arctic Ocean, to the east by the Atlantic Ocean, to the southeast by South America and the Car ...
(by Bombardier) until a joined effort on a common UIC train bus was started (with
Siemens Siemens AG ( ) is a German multinational conglomerate corporation and the largest industrial manufacturing company in Europe headquartered in Munich with branch offices abroad. The principal divisions of the corporation are ''Industry'', '' ...
and other industry partners) that led to the WTB/MVB standard in late 1999.


Alternate vehicle buses

The MVB standard was introduced to replace the multitude of field buses in the train equipment. Despite the advantages of the MVB field bus, many vehicle buses are still built from
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
, WorldFIP (in
France France (), officially the French Republic ( ), is a country primarily located in Western Europe. It also comprises of Overseas France, overseas regions and territories in the Americas and the Atlantic Ocean, Atlantic, Pacific Ocean, Pac ...
), LonWorks (in the
USA The United States of America (U.S.A. or USA), commonly known as the United States (U.S. or US) or America, is a country Continental United States, primarily located in North America. It consists of 50 U.S. state, states, a Washington, D.C., ...
) and Profibus components. While the WorldFIP,
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
, Lonworks and Profinet are controlled by international manufacturer associations targeting a wide range of application, MVB was tailored to the rolling stock application, with the goal of plug-compatibility, and therefore allows no options. This was intentional as the fight between the field busses raged in the 1990s and the decision of the
IEC The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
that any of the eight field busses was a standard did not help plug-compatibility. MVB modules are more expensive than for instance
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
or LonWorks components. This is not due to the communication technology: most devices implement the MVB protocol machine in a small area of an
FPGA A field-programmable gate array (FPGA) is an integrated circuit designed to be configured by a customer or a designer after manufacturinghence the term '' field-programmable''. The FPGA configuration is generally specified using a hardware de ...
which is today anyhow present, and the costliest component remains the connector. But railways certification is costly and not always needed for uncritical applications such as comfort and passenger information. When total cost of ownership is considered, the cost of the hardware elements can easily be outweighed by additional engineering costs in the railways market with its small series. In the
USA The United States of America (U.S.A. or USA), commonly known as the United States (U.S. or US) or America, is a country Continental United States, primarily located in North America. It consists of 50 U.S. state, states, a Washington, D.C., ...
, the IEEE RTVISC evaluated both MVB and
LON Lon or LON may refer to: People * Lon (photographer), pseudonym of Alonzo Hanagan, also known as "Lon of New York" * Lon (name), a list of people with the given name, nickname or surname Fictional characters * Lon Cohen, a character in the Ne ...
as vehicle and train bus. The
IEEE The Institute of Electrical and Electronics Engineers (IEEE) is a 501(c)(3) professional association for electronic engineering and electrical engineering (and associated disciplines) with its corporate office in New York City and its operation ...
finally decided to standardize both in IEEE 1374, with a clear separation of tasks: * MVB for critical operation such as traction control and signalling in the driver's cab, * LON for uncritical and slow data transfer, but low-cost connections such as passenger displays and diagnostics. This separation is not always observed. Additionally more and more components are added to rail vehicles that need far more bandwidth than any field bus can provide (e.g. for video surveillance), so
switched Ethernet A network switch (also called switching hub, bridging hub, and, by the IEEE, MAC bridge) is networking hardware that connects devices on a computer network by using packet switching to receive and forward data to the destination device. A netw ...
IEEE 802.3 IEEE 802.3 is a working group and a collection standards defining the physical layer and data link layer's media access control (MAC) of wired Ethernet. The standards are produced by the working group of Institute of Electrical and Electronics Eng ...
with 100 Mbit/s is being introduced into train sets (according to the EN 50155 profile). Still all the alternate vehicle buses are connected to the Wire Train Bus. MVB is similar to FlexRay, both have the "process data", which is called "static segment" in FlexRay, and "message data", which is the "dynamic segment" and are driven by a fixed TDMA scheme. Running FlexRay with 2.5 Mbit, an RS-485 physical layer and only one "coldstarter" would lead to a very similar behavior in respect to the application. Despite the similarities, no rail-manufacturer has considered FlexRay, since they valuated a common solution higher than a multitude of better busses. Conversely, in 1999, the automotive industry evaluated MVB (in an extended 24 Mbit/s version), but dropped it because of the costs, which should be unreasonably low for the mass-market of millions of vehicles.


Wire train bus (WTB)

The wire train bus has been designed for international passenger trains with variable composition, consisting of up to 22 vehicles. The medium consists of a duplicated shielded twisted pair cable, which runs in the UIC cables between the vehicles. The connector between the vehicles is the 18-pole UIC connector. Since connectors are exposed and can oxidize, a current pulse is applied at connection establishment to evaporate the oxide layer, called fritting. The standard connector for the WTB nodes is a DIN 9 pin connector. The physical level uses RS-485 levels at 1 Mbit/s data rate. The encoding uses a Manchester II code and a
HDLC High-Level Data Link Control (HDLC) is a bit-oriented code-transparent synchronous data link layer protocol developed by the International Organization for Standardization (ISO). The standard for HDLC is ISO/IEC 13239:2002. HDLC provides both c ...
frame protocol with proper voltage balancing to avoid DC components in the galvanic isolation transformers. The Manchester decoder uses a phase/quadrature
demodulation Demodulation is extracting the original information-bearing signal from a carrier wave. A demodulator is an electronic circuit (or computer program in a software-defined radio) that is used to recover the information content from the modulated ...
(not RS-485, that operates with zero-crossings) which allows to span 750 m under worst-case conditions, especially when only the two extremity vehicles are equipped, as is the case with multiple traction for freight trains. No repeaters are foreseen since vehicles in between can have discharged batteries. A unique property of the WTB is the train inauguration (In German: ''Zugtaufe'') in which the newly connected vehicles receive an address in sequence and can identify the vehicle side (called ''port'' and ''starboard'' like in the marine) so that doors open on the correct side. Up to 32 addresses can be dynamically allocated. When two train compositions join, the addresses are reallocated to form a new composition of vehicles with a sequential address. Vehicles without WTB node ("c''onduction vehicles''") are not counted. The frames have a maximum payload of 1024 bits. The WTB operates cyclically to provide
deterministic Determinism is a philosophical view, where all events are determined completely by previously existing causes. Deterministic theories throughout the history of philosophy have developed from diverse and sometimes overlapping motives and consi ...
operation, with a period of 25 ms, used mainly for the traction control. The WTB also supports sporadic data transmission for diagnostics. The content of the periodic and sporadic frames is governed by the UIC 556 standard. Since frame size is limited, a version of
TCP TCP may refer to: Science and technology * Transformer coupled plasma * Tool Center Point, see Robot end effector Computing * Transmission Control Protocol, a fundamental Internet standard * Telephony control protocol, a Bluetooth communication s ...
with reduced overhead was used for message segmenting and reassembly, that at the same time allows to cope with changes in composition, called RTP ( Real-Time Protocol).


Alternate train buses


History

The WTB was derived from the German
DIN DIN or Din or din may refer to: People and language * Din (name), people with the name * Dīn, an Arabic word with three general senses: judgment, custom, and religion from which the name originates * Dinka language (ISO 639 code: din), spoken by ...
bus developed by
ABB Henschel Henschel & Son (german: Henschel und Sohn) was a German company, located in Kassel, best known during the 20th century as a maker of transportation equipment, including locomotives, trucks, buses and trolleybuses, and armoured fighting vehicle ...
(now Bombardier). It benefited from the phase/quadrature decoding provided by
Italy Italy ( it, Italia ), officially the Italian Republic, ) or the Republic of Italy, is a country in Southern Europe. It is located in the middle of the Mediterranean Sea, and its territory largely coincides with the homonymous geographical re ...
and from an improved train inauguration provided by
Switzerland ). Swiss law does not designate a ''capital'' as such, but the federal parliament and government are installed in Bern, while other federal institutions, such as the federal courts, are in other cities (Bellinzona, Lausanne, Luzern, Neuchâtel ...
, based on the experience with the FSK multiple traction bus of ABB Secheron, Geneva used in the SBB freight trains. The physical layer of WTB shows similarities with the WorldFIP field bus ( EN 50170 part 4) - its "voltage mode" did use 1 Mbit/s and a maximum of 32 stations on the bus with a maximum length of 750 meters, the use of FIP transceivers was studied early in the TCN evaluation, but the Phase/Quadrature decoding was used instead.


Usage

The TCN is used in most of the modern train control systems usually connecting the vehicles with an 18-pin UIC 558, including: *
Deutsche Bahn The (; abbreviated as DB or DB AG) is the national railway company of Germany. Headquartered in the Bahntower in Berlin, it is a joint-stock company ( AG). The Federal Republic of Germany is its single shareholder. describes itself as the se ...
:
ICE T DBAG Class 411 and Class 415 are German tilting electric multiple-unit high-speed trains in service with DB Fernverkehr, commonly known as ICE T. Development Following the successful inauguration of the Intercity-Express system in 199 ...
,
ICE-TD The DBAG Class 605, commonly known as the ICE TD is a high-speed diesel multiple unit (DMU) train, formerly in service with Deutsche Bahn and DSB. History Development Following the successful inauguration of the Intercity-Express system ...
, ICE 3 and TRAXX AC2 P160 *
Swiss Federal Railways Swiss Federal Railways (german: link=no, Schweizerische Bundesbahnen, ''SBB''; french: link=no, Chemins de fer fédéraux suisses, ''CFF''; it, Ferrovie federali svizzere, ''FFS'') is the national railway company of Switzerland. It is usuall ...
:
IC2000 The IC 2000 is a double-deck train in Switzerland and is run by Swiss Federal Railways (SBB-CFF-FFS) as part of its InterCity service. Top speed is 200 km/h. The train set can be composed of up to 10 coaches and provides close to 1,000 se ...
and EW IV ( de) * Austrian Federal Railways: All Railjet and Talent trains


Further reading

* Ethernet Train Backbone * Ethernet Consist Network * WorldFIP *
CANopen CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an address ...
* Lonworks * Profinet * FlexRay


Notes and references


External links

* * {{Computer-bus Rail technologies Serial buses Automated track-bound traffic