Building automation (BAS), also known as building management system (BMS) or building energy management system (BEMS), is the automatic centralized control of a building's HVAC (heating, ventilation and air conditioning), electrical,
lighting Lighting or illumination is the deliberate use of light to achieve practical or aesthetic effects. Lighting includes the use of both artificial light sources like lamps and light fixtures, as well as natural illumination by capturing daylig ...
, shading, Access Control,
Security Systems Security is protection from, or resilience against, potential harm (or other unwanted coercive change) caused by others, by restraining the freedom of others to act. Beneficiaries (technically referents) of security may be of persons and social ...
, and other interrelated systems. Some objectives of building automation are improved occupant comfort, efficient operation of building systems, reduction in energy consumption, reduced operating and maintaining costs and increased security. BAS functionality may keep a buildings climate within a specified range, provide light to rooms based on an occupancy, monitor performance and device failures, and provide malfunction alarms to building maintenance staff. A BAS works to reduce building energy and maintenance costs compared to a non-controlled building. Most commercial, institutional, and industrial buildings built after 2000 include a BAS, whilst older buildings may be retrofitted with a new BAS. A building controlled by a BAS is often referred to as an intelligent building, "smart building," or (if a residence) a "
smart home Smart or SMART may refer to: Arts and entertainment * ''Smart'' (Hey! Say! JUMP album), 2014 * Smart (Hotels.com), former mascot of Hotels.com * ''Smart'' (Sleeper album), 1995 debut album by Sleeper * '' SMart'', a children's television se ...
." Commercial and industrial buildings have historically relied on robust proven protocols (like BACnet) while proprietary protocols (like X-10) were used in homes. Almost all multi-story
green building Green building (also known as green construction or sustainable building) refers to both a structure and the application of processes that are environmentally responsible and resource-efficient throughout a building's life-cycle: from planni ...
s are designed to accommodate a BAS for the energy, air and water conservation characteristics. Electrical device demand response is a typical function of a BAS, as is the more sophisticated ventilation and humidity monitoring required of "tight" insulated buildings. Most green buildings also use as many low-power DC devices as possible. Even a passivhaus design intended to consume no net energy whatsoever will typically require a BAS to manage heat capture, shading and venting, and scheduling device use.


Characteristics

Building management systems are most commonly implemented in large projects with extensive mechanical, HVAC, and electrical systems. Systems linked to a BMS typically represent 40% of a building's energy usage; if lighting is included, this number approaches to 70%. BMS systems are a critical component to managing energy demand. Improperly configured BMS systems are believed to account for 20% of building energy usage, or approximately 8% of total energy usage in the United States. In addition to controlling the building's internal environment, BMS systems are sometimes linked to access control (turnstiles and access doors controlling who is allowed access and egress to the building) or other security systems such as closed-circuit television (CCTV) and motion detectors. Fire alarm systems and elevators are also sometimes linked to a BMS for monitoring. In case a fire is detected then only the fire alarm panel could close dampers in the ventilation system to stop smoke spreading, shut down air handlers, start smoke evacuation fans, and send all the elevators to the ground floor and park them to prevent people from using them. Building management systems have also included disaster-response mechanisms (such as
base isolation Seismic base isolation, also known as base isolation, or base isolation system, is one of the most popular means of protecting a structure against earthquake forces. It is a collection of structural elements which should substantially decoupl ...
) to save structures from earthquakes. In more recent times, companies and governments have been working to find similar solutions for flood zones and coastal areas at-risk to rising sea levels. Self-adjusting floating environment draws from existing technologies used to float concrete bridges and runways such as Washington's SR 520 and Japan's Mega-Float.


Types of inputs and outputs


Sensors

Analog inputs are used to read a variable measurement. Examples are
temperature Temperature is a physical quantity that expresses quantitatively the perceptions of hotness and coldness. Temperature is measurement, measured with a thermometer. Thermometers are calibrated in various Conversion of units of temperature, temp ...
,
humidity Humidity is the concentration of water vapor present in the air. Water vapor, the gaseous state of water, is generally invisible to the human eye. Humidity indicates the likelihood for precipitation, dew, or fog to be present. Humidity dep ...
and pressure sensors which could be
thermistor A thermistor is a type of resistor whose resistance is strongly dependent on temperature, more so than in standard resistors. The word thermistor is a portmanteau of ''thermal'' and ''resistor''. Thermistors are divided based on their conduction ...
, 4–20 mA, 0–10
volt The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). It is named after the Italian physicist Alessandro Volta (1745–1827). Defin ...
or platinum
resistance thermometer Resistance thermometers, also called resistance temperature detectors (RTDs), are sensors used to measure temperature. Many RTD elements consist of a length of fine wire wrapped around a heat-resistant ceramic or glass core but other constructio ...
(resistance temperature detector), or wireless sensors. A digital input indicates a device is on or off. Some examples of digital inputs would be a door contact switch, a current switch, an air flow
switch In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type of ...
, or a voltage-free
relay A relay Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off A relay is an electrically operated switch ...
contact (dry contact). Digital inputs could also be pulse inputs counting the pulses over a period of time. An example is a turbine flow meter transmitting flow data as a frequency of pulses to an input. Nonintrusive load monitoring is software relying on digital sensors and algorithms to discover appliance or other loads from electrical or magnetic characteristics of the circuit. It is however detecting the event by an analog means. These are extremely cost-effective in operation and useful not only for identification but to detect start-up transients, line or equipment faults, etc.


Controls

Analog outputs control the speed or position of a device, such as a
variable frequency drive A variable-frequency drive (VFD) is a type of motor drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and, depending on topology, to control associated voltage or current variat ...
, an I-P (
current Currents, Current or The Current may refer to: Science and technology * Current (fluid), the flow of a liquid or a gas ** Air current, a flow of air ** Ocean current, a current in the ocean *** Rip current, a kind of water current ** Current (stre ...
to pneumatics)
transducer A transducer is a device that converts energy from one form to another. Usually a transducer converts a signal in one form of energy to a signal in another. Transducers are often employed at the boundaries of automation, measurement, and cont ...
, or a valve or damper actuator. An example is a hot water valve opening up 25% to maintain a setpoint. Another example is a
variable frequency drive A variable-frequency drive (VFD) is a type of motor drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and, depending on topology, to control associated voltage or current variat ...
ramping up a motor slowly to avoid a hard start. Digital outputs are used to open and close relays and switches as well as drive a load upon command. An example would be to turn on the parking lot lights when a
photocell Photodetectors, also called photosensors, are sensors of light or other electromagnetic radiation. There is a wide variety of photodetectors which may be classified by mechanism of detection, such as photoelectric or photochemical effects, or b ...
indicates it is dark outside. Another example would be to open a valve by allowing 24VDC/AC to pass through the output powering the valve. Analog outputs could also be pulse type outputs emitting a frequency of pulses over a given period of time. An example is an energy meter calculating kWh and emitting a frequency of pulses accordingly.


Infrastructure


Controller

Controllers are essentially small, purpose-built computers with input and output capabilities. These controllers come in a range of sizes and capabilities to control devices commonly found in buildings, and to control sub-networks of controllers. Inputs allow a controller to read temperature, humidity, pressure, current flow, air flow, and other essential factors. The outputs allow the controller to send command and control signals to slave devices, and to other parts of the system. Inputs and outputs can be either digital or analog. Digital outputs are also sometimes called discrete depending on manufacturer. Controllers used for building automation can be grouped in three categories: programmable logic controllers (PLCs), system/network controllers, and terminal unit controllers. However an additional device can also exist in order to integrate third-party systems (e.g. a stand-alone AC system) into a central building automation system. Terminal unit controllers usually are suited for control of lighting and/or simpler devices such as a package rooftop unit, heat pump, VAV box, fan coil, etc. The installer typically selects one of the available pre-programmed personalities best suited to the device to be controlled, and does not have to create new control logic.


Occupancy

Occupancy is one of two or more operating modes for a building automation system; Unoccupied, Morning Warmup, and Night-time Setback are other common modes. Occupancy is usually based on time of day schedules. In Occupancy mode, the BAS aims to provides a comfortable climate and adequate lighting, often with zone-based control so that users on one side of a building have a different thermostat (or a different system, or sub system) than users on the opposite side. A temperature sensor in the zone provides feedback to the controller, so it can deliver heating or cooling as needed. If enabled, morning warmup (MWU) mode occurs prior to occupancy. During Morning Warmup the BAS tries to bring the building to setpoint just in time for Occupancy. The BAS often factors in outdoor conditions and historical experience to optimize MWU. This is also referred to as ''optimized start''. Some buildings rely on occupancy sensors to activate lighting or climate conditioning. Given the potential for long lead times before a space becomes sufficiently cool or warm, climate conditioning is not often initiated directly by an occupancy sensor.


Lighting

Lighting Lighting or illumination is the deliberate use of light to achieve practical or aesthetic effects. Lighting includes the use of both artificial light sources like lamps and light fixtures, as well as natural illumination by capturing daylig ...
can be turned on, off, or dimmed with a building automation or lighting control system based on time of day, or on occupancy sensor, photosensors and timers. One typical example is to turn the lights in a space on for a half-hour since the last motion was sensed. A photocell placed outside a building can sense darkness, and the time of day, and modulate lights in outer offices and the parking lot. Lighting is also a good candidate for demand response, with many control systems providing the ability to dim (or turn off) lights to take advantage of DR incentives and savings. In newer buildings, the lighting control can be based on the field bus Digital Addressable Lighting Interface (DALI). Lamps with DALI ballasts are fully dimmable. DALI can also detect lamp and ballast failures on DALI luminaires and signals failures.


Shading and glazing

Shading and glazing are essential components in the building system, they affect occupants’ visual, acoustical, and
thermal comfort Thermal comfort is the condition of mind that expresses satisfaction with the thermal environment and is assessed by subjective evaluation ( ANSI/ASHRAE Standard 55).ANSI/ASHRAE Standard 55-2017, Thermal Environmental Conditions for Human Occupan ...
and provide the occupant with a view outdoor. Automated shading and glazing systems are solutions for controlling solar heat gains and glare. It refers to the use of technology to control external or internal shading devices (such as blinds, and shades) or glazing itself. The system has an active and rapid response to various changing outdoor data (such as solar, wind) and to changing interior environment (such as temperature, illuminance, and occupant demands). Building shading and glazing systems can contribute to thermal and lighting improvement from both energy conservation and comfort point of view.


Dynamic shading

Dynamic shading devices allow the control of daylight and solar energy to enter into built environment in relation to outdoor conditions, daylighting demands and solar positions. The common products include
venetian blinds A window blind is a type of window covering. There are many different kinds of window blinds which use a variety of control systems. A typical window blind is made up of several long horizontal or vertical slats of various types of hard mate ...
, roller shades,
louver A louver (American English) or louvre (British English; see spelling differences) is a window blind or shutter with horizontal slats that are angled to admit light and air, but to keep out rain and direct sunshine. The angle of the sla ...
s, and shutters. They are mostly installed on the interior side of the glazing system because of the low maintenance cost, but also can be used on the exterior or a combination of both.


Air Handlers

Most
air handler An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning ( HVAC) system. An air handler is usually a large metal box containing a blow ...
s mix return and outside air so less temperature/humidity conditioning is needed. This can save money by using less chilled or heated water (not all AHUs use chilled or hot water circuits). Some external air is needed to keep the building's air healthy. To optimize energy efficiency while maintaining healthy indoor air quality (IAQ), demand control (or controlled) ventilation (DCV) adjusts the amount of outside air based on measured levels of occupancy. Analog or digital temperature sensors may be placed in the space or room, the return and supply air ducts, and sometimes the external air. Actuators are placed on the hot and chilled water valves, the outside air and return air dampers. The supply fan (and return if applicable) is started and stopped based on either time of day, temperatures, building pressures or a combination.


Alarms and Security

All modern building automation systems have alarm capabilities. It does little good to detect a potentially hazardous or costly situation if no one who can solve the problem is notified. Notification can be through a computer (email or text message),
pager A pager (also known as a beeper or bleeper) is a wireless telecommunications device that receives and displays alphanumeric or voice messages. One-way pagers can only receive messages, while response pagers and two-way pagers can also acknow ...
, cellular phone voice call, audible alarm, or all of these. For insurance and liability purposes all systems keep logs of who was notified, when and how. Alarms may immediately notify someone or only notify when alarms build to some threshold of seriousness or urgency. At sites with several buildings, momentary power failures can cause hundreds or thousands of alarms from equipment that has shut down – these should be suppressed and recognized as symptoms of a larger failure. Some sites are programmed so that critical alarms are automatically re-sent at varying intervals. For example, a repeating critical alarm (of an uninterruptible power supply in 'bypass') might resound at 10 minutes, 30 minutes, and every 2 to 4 hours thereafter until the alarms are resolved. Security systems can be interlocked to a building automation system. If occupancy sensors are present, they can also be used as burglar alarms. Because security systems are often deliberately sabotaged, at least some detectors or cameras should have battery backup and wireless connectivity and the ability to trigger alarms when disconnected. Modern systems typically use power-over-Ethernet (which can operate a pan-tilt-zoom camera and other devices up to 30–90 watts) which is capable of charging such batteries and keeps wireless networks free for genuinely wireless applications, such as backup communication in outage. Fire alarm panels and their related smoke alarm systems are usually hard-wired to override building automation. For example: if the smoke alarm is activated, all the outside air dampers close to prevent air coming into the building, and an exhaust system can isolate the blaze. Similarly, electrical fault detection systems can turn entire circuits off, regardless of the number of alarms this triggers or persons this distresses. Fossil fuel combustion devices also tend to have their own over-rides, such as
natural gas Natural gas (also called fossil gas or simply gas) is a naturally occurring mixture of gaseous hydrocarbons consisting primarily of methane in addition to various smaller amounts of other higher alkanes. Low levels of trace gases like carbo ...
feed lines that turn off when slow pressure drops are detected (indicating a leak), or when excess
methane Methane ( , ) is a chemical compound with the chemical formula (one carbon atom bonded to four hydrogen atoms). It is a group-14 hydride, the simplest alkane, and the main constituent of natural gas. The relative abundance of methane on Ea ...
is detected in the building's air supply.


Buses and protocols

Most building automation networks consist of a ''primary'' and ''secondary''
bus A bus (contracted from omnibus, with variants multibus, motorbus, autobus, etc.) is a road vehicle that carries significantly more passengers than an average car or van. It is most commonly used in public transport, but is also in use for cha ...
which connect high-level controllers (generally specialized for building automation, but may be generic programmable logic controllers) with lower-level controllers,
input/output In computing, input/output (I/O, or informally io or IO) is the communication between an information processing system, such as a computer, and the outside world, possibly a human or another information processing system. Inputs are the signals ...
devices and a
user interface In the industrial design field of human–computer interaction, a user interface (UI) is the space where interactions between humans and machines occur. The goal of this interaction is to allow effective operation and control of the machine f ...
(also known as a human interface device).
ASHRAE The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE ) is an American professional association seeking to advance heating, ventilation, air conditioning and refrigeration The term refrigeration refers to the ...
's open protocol BACnet or the open protocol
LonTalk LonTalk is a protocol optimized for control. Originally developed by Echelon Corporation for networking devices over media such as twisted pair, powerlines, fiber optics, and RF. It is popular for the automation of various functions in industri ...
specify how most such devices interoperate. Modern systems use
SNMP Simple Network Management Protocol (SNMP) is an Internet Standard protocol for collecting and organizing information about managed devices on IP networks and for modifying that information to change device behaviour. Devices that typically ...
to track events, building on decades of history with SNMP-based protocols in the computer networking world. Physical connectivity between devices was historically provided by dedicated
optical fiber An optical fiber, or optical fibre in Commonwealth English, is a flexible, transparent fiber made by drawing glass ( silica) or plastic to a diameter slightly thicker than that of a human hair. Optical fibers are used most often as a mea ...
,
ethernet Ethernet () is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 1 ...
,
ARCNET Attached Resource Computer NETwork (ARCNET or ARCnet) is a communications protocol for local area networks. ARCNET was the first widely available networking system for microcomputers; it became popular in the 1980s for office automation tasks. It ...
,
RS-232 In telecommunications, RS-232 or Recommended Standard 232 is a standard originally introduced in 1960 for serial communication transmission of data. It formally defines signals connecting between a ''DTE'' (''data terminal equipment'') such ...
,
RS-485 RS-485, also known as TIA-485(-A) or EIA-485, is a standard defining the electrical characteristics of drivers and receivers for use in serial communications systems. Electrical signaling is balanced, and multipoint systems are supported. The s ...
or a low-bandwidth special purpose
wireless network A wireless network is a computer network that uses wireless data connections between network nodes. Wireless networking is a method by which homes, telecommunications networks and business installations avoid the costly process of introducing ...
. Modern systems rely on standards-based multi-protocol heterogeneous networking such as that specified in the
IEEE 1905.1 IEEE 1905.1 is an IEEE standard which defines a network enabler for home networking supporting both wireless and wireline technologies: IEEE 802.11 (marketed under the Wi-Fi trademark), IEEE 1901 ( HomePlug, HD-PLC) powerline networking, IEEE 8 ...
standard and verified by the nVoy auditing mark. These accommodate typically only IP-based networking but can make use of any existing wiring, and also integrate powerline networking over AC circuits,
power over Ethernet Power over Ethernet, or PoE, describes any of several Technical standard, standards or ad hoc systems that pass electric power along with data on Ethernet over twisted pair, twisted-pair Ethernet cabling. This allows a single cable to provide ...
low-power DC circuits, high-bandwidth wireless networks such as LTE and IEEE 802.11n and
IEEE 802.11ac IEEE 802.11ac-2013 or 802.11ac is a wireless networking standard in the IEEE 802.11 set of protocols (which is part of the Wi-Fi networking family), providing high-throughput wireless local area networks (WLANs) on the 5 GHz band. The stan ...
and often integrate these using the building-specific wireless mesh open standard
ZigBee Zigbee is an IEEE 802.15.4-based specification for a suite of high-level communication protocols used to create personal area networks with small, low-power digital radios, such as for home automation, medical device data collection, and o ...
.
Proprietary hardware Proprietary hardware is computer hardware whose interface is controlled by the proprietor, often under patent or trade-secret protection. Historically, most early computer hardware was designed as proprietary until the 1980s, when IBM PC changed ...
dominates the controller market. Each company has controllers for specific applications. Some are designed with limited controls and no interoperability, such as simple packaged roof top units for HVAC. Software will typically not integrate well with packages from other vendors. Cooperation is at the Zigbee/BACnet/LonTalk level only. Current systems provide interoperability at the application level, allowing users to mix-and-match devices from different manufacturers, and to provide integration with other compatible building control systems. These typically rely on
SNMP Simple Network Management Protocol (SNMP) is an Internet Standard protocol for collecting and organizing information about managed devices on IP networks and for modifying that information to change device behaviour. Devices that typically ...
, long used for this same purpose to integrate diverse computer networking devices into one coherent network.


Protocols and industry standards

* 1-Wire * BACnet *
Bluetooth Bluetooth is a short-range wireless technology standard that is used for exchanging data between fixed and mobile devices over short distances and building personal area networks (PANs). In the most widely used mode, transmission power is limi ...
* DALI *
Dynet DyNet is the communications network and communications protocol for Dynalite lighting automation and building automation Building automation (BAS), also known as building management system (BMS) or building energy management system (BEMS), ...
* EnOcean * KNX *
LonTalk LonTalk is a protocol optimized for control. Originally developed by Echelon Corporation for networking devices over media such as twisted pair, powerlines, fiber optics, and RF. It is popular for the automation of various functions in industri ...
* MIDAC * OPC * OpenTherm * OpenWebNet * VSCP *
Zigbee Zigbee is an IEEE 802.15.4-based specification for a suite of high-level communication protocols used to create personal area networks with small, low-power digital radios, such as for home automation, medical device data collection, and o ...
*
Z-Wave Z-Wave is a wireless communications protocol used primarily for residential and commercial building automation. It is a mesh network using low-energy radio waves to communicate from device to device, allowing for wireless control of smart home de ...


Security Concerns

With the growing spectrum of capabilities and connections to the Internet of Things, building automation systems were repeatedly reported to be vulnerable, allowing hackers and cybercriminals to attack their components. Buildings can be exploited by hackers to measure or change their environment: sensors allow surveillance (e.g. monitoring movements of employees or habits of inhabitants) while actuators allow to perform actions in buildings (e.g. opening doors or windows for intruders). Several vendors and committees started to improve the security features in their products and standards, including KNX, ZigBee and BACnet (see recent standards or standard drafts). However, researchers report several open problems in building automation security. On November 11, 2019, a 132-page security research paper was released titled "I Own Your Building (Management System)" by Gjoko Krstic and Sipke Mellema that addressed more than 100 vulnerabilities affecting various BMS and access control solutions by various vendors.


Room automation

Room automation is a subset of building automation and with a similar purpose; it is the consolidation of one or more systems under centralized control, though in this case in one room. The most common example of room automation is corporate boardroom, presentation suites, and lecture halls, where the operation of the large number of devices that define the room function (such as
videoconferencing Videotelephony, also known as videoconferencing and video teleconferencing, is the two-way or multipoint reception and transmission of audio and video signals by people in different locations for real time communication.McGraw-Hill Concise Ency ...
equipment,
video projector A video projector is an image projector that receives a video signal and projects the corresponding image on a projection screen using a lens system. Video projectors use a very bright ultra-high-performance lamp (a special mercury arc lamp), X ...
s, lighting control systems, public address systems etc.) would make manual operation of the room very complex. It is common for room automation systems to employ a
touchscreen A touchscreen or touch screen is the assembly of both an input ('touch panel') and output ('display') device. The touch panel is normally layered on the top of an electronic visual display of an information processing system. The display is ofte ...
as the primary way of controlling each operation.


See also

*
Control engineering Control engineering or control systems engineering is an engineering discipline that deals with control systems, applying control theory to design equipment and systems with desired behaviors in control environments. The discipline of controls o ...
*
Digital home Home automation or domotics is building automation for a home, called a smart home or smart house. A home automation system will monitor and/or control home attributes such as lighting, climate, entertainment systems, and appliances. It ma ...
* Index of home automation articles * Smart environment * Testing, adjusting, balancing


References


External links

* * v:Building Automation Provides learning resources for professionals in this area {{DEFAULTSORT:Building Automation Sustainable urban planning