The ''Waage Drill II'' diving accident occurred in the
North Sea The North Sea lies between Great Britain, Norway, Denmark, Germany, the Netherlands and Belgium. An epeiric sea, epeiric sea on the European continental shelf, it connects to the Atlantic Ocean through the English Channel in the south and the ...
off Scotland on 9 September 1975, when two divers died of
heatstroke Heat stroke or heatstroke, also known as sun stroke, is a severe heat illness that results in a body temperature greater than , along with red skin, headache, dizziness, and confusion. Sweating is generally present in exertional heatstroke, b ...
after the chamber they were in was inadvertently pressurised with helium gas.


Background

On 9 September 1975, divers Peter Holmes, 29, and Roger Baldwin, 24, had been hoisted from the
North Sea The North Sea lies between Great Britain, Norway, Denmark, Germany, the Netherlands and Belgium. An epeiric sea, epeiric sea on the European continental shelf, it connects to the Atlantic Ocean through the English Channel in the south and the ...
in a bell and connected to the system's entrance lock. The men had just completed a short dive to to clear a tangle of rope that had wrapped itself around the guideposts of the
blowout preventer A blowout preventer (BOP) (pronounced B-O-P, not "bop") is a specialized valve or similar mechanical device, used to seal, control and monitor oil well, oil and gas wells to prevent Blowout (well drilling), blowouts, the uncontrolled release of ...
. The dive had gone well and now the plan was to decompress the men inside the bell to , then transfer them into the chamber complex and hold them in saturation. As with all deep-dive systems, each chamber on the supervisor's control panel was represented by a series of valves and gauges. Redundancy in plumbing schemes was common and necessary, and with this particular system, by turning several valves on the console, any one depth gauge could be made to monitor the depth of a chamber other than for which it was normally intended. On chamber one's panel, there was a Heise gauge considered to be the most accurate. Because of the cross-referencing capabilities of the system, it became the practice of the shift supervisor to set the valves of this gauge to read the internal depth of the bell prior to the divers leaving bottom, then track their ascent through the lock‑on and transfer procedure. The rationale behind using this particular gauge throughout the operation was to avoid any potential decompression problems that might arise from using two separate gauges with a discrepancy problem. Once the divers had safely passed from the bell to the entrance lock to chamber one, the supervisor was then supposed to turn the valves back to their original positions in order to monitor the depth of the divers.


Accident

At 21:50 that evening, the crew mated the bell to the entrance lock as planned, but during the lock‑on procedure a gas leak developed between the mating flanges. The bell was removed, the flange surfaces were cleaned, and on the second attempt the bell was successfully sealed to the system. After Holmes and Baldwin equalized the bell with the rest of the complex, they opened the inside door and were in the process of transferring into the entrance lock when the gas leak suddenly returned. With the needle on the Heise gauge dropping, an attempt was made to isolate the divers from the leak by sealing the door of the entrance lock that led to the bell, but according to the dive log this effort was "abandoned." To protect Holmes and Baldwin from further pressure loss, the supervisor ordered them to climb into chamber one. There, they leaned against the inside hatch while the supervisor injected a small amount of helium inside the chamber to seal the door. At this point, the supervisor forgot to reset the valves to reconnect the Heise gauge with chamber one. Because chamber one was not equipped with a dedicated depth gauge, Holmes and Baldwin were now in a part of the system not being monitored by any gauge. Meanwhile, the Heise gauge was still recording a pressure drop, which the supervisor erroneously believed was reading chamber one. He thought that he had failed to achieve a seal on chamber one's hatch, and so he began to feed large quantities of pure helium into the chamber where the two divers were stationed. By the time he realized his error, Holmes and Baldwin had been pressurized from to over the course of several minutes. The rapid compression, combined with the high thermal transfer property of helium, plus the high humidity factor of the atmosphere, caused the temperature of the atmosphere to rise from an estimated to . The two divers began pulling desperately on the chamber hatch to escape, but were unable to open the door. They took the mattresses off their bunks and lay on the somewhat cooler aluminum surfaces, but forced to breathe an intolerable atmosphere, the men died several hours later of
hyperthermia Hyperthermia, also known simply as overheating, is a condition in which an individual's body temperature is elevated beyond normal due to failed thermoregulation. The person's body produces or absorbs more heat than it dissipates. When extreme ...
.


Fatal accident inquiry

It was later pointed out by the presiding judge at the
fatal accident inquiry A fatal accident inquiry is a Scottish judicial process which investigates and determines the circumstances of some deaths occurring in Scotland. Until 2009, they did not apply to any deaths occurring in other jurisdictions, when the Coroners an ...
that the way in which the diving system was designed and labelled, "especially as operated by Oceaneering, carried a high risk of human error, particularly during the distractions of an emergency". Oceaneering's safety officer testified that the manner in which the control panel was plumbed “was a contributory cause” of the accident, and that it probably would not have happened had the panel for chamber one been equipped with a dedicated depth gauge permanently fixed for the purpose of reading only that chamber. Had there been such a gauge, then the supervisor would not have been misled by the Heise gauge, and therefore would not have had any reason to inject the chamber with massive amounts of helium.