PH meter
   HOME

TheInfoList



OR:

A pH meter is a
scientific instrument A scientific instrument is a device or tool used for scientific purposes, including the study of both natural phenomena and theoretical research. History Historically, the definition of a scientific instrument has varied, based on usage, laws, a ...
that measures the hydrogen-ion activity in water-based solutions, indicating its acidity or
alkalinity Alkalinity (from ar, القلوي, al-qaly, lit=ashes of the saltwort) is the capacity of water to resist acidification. It should not be confused with basicity, which is an absolute measurement on the pH scale. Alkalinity is the strength ...
expressed as pH. The pH meter measures the difference in electrical potential between a pH electrode and a reference electrode, and so the pH meter is sometimes referred to as a "potentiometric pH meter". The difference in electrical potential relates to the acidity or pH of the solution. Testing of pH via pH meters (pH-metry) is used in many applications ranging from laboratory experimentation to
quality control Quality control (QC) is a process by which entities review the quality of all factors involved in production. ISO 9000 defines quality control as "a part of quality management focused on fulfilling quality requirements". This approach place ...
.


Applications

The rate and outcome of chemical reactions taking place in water often depends on the acidity of the water, and it is therefore useful to know the acidity of the water, typically measured by means of a pH meter. Knowledge of pH is useful or critical in many situations, including chemical laboratory analyses. pH meters are used for
soil Soil, also commonly referred to as earth or dirt, is a mixture of organic matter, minerals, gases, liquids, and organisms that together support life. Some scientific definitions distinguish ''dirt'' from ''soil'' by restricting the former ...
measurements in
agriculture Agriculture or farming is the practice of cultivating plants and livestock. Agriculture was the key development in the rise of sedentary human civilization, whereby farming of domesticated species created food surpluses that enabled people ...
,
water quality Water quality refers to the chemical, physical, and biological characteristics of water based on the standards of its usage. It is most frequently used by reference to a set of standards against which compliance, generally achieved through tr ...
for
municipal water Tap water (also known as faucet water, running water, or municipal water) is water supplied through a tap, a water dispenser valve. In many countries, tap water usually has the quality of drinking water. Tap water is commonly used for drinking, ...
supplies, swimming pools,
environmental remediation Environmental remediation deals with the removal of pollution or contaminants from environmental media such as soil, groundwater, sediment, or surface water. Remedial action is generally subject to an array of regulatory requirements, and may al ...
;
brewing Brewing is the production of beer by steeping a starch source (commonly cereal grains, the most popular of which is barley) in water and fermenting the resulting sweet liquid with yeast. It may be done in a brewery by a commercial brewer ...
of wine or beer;
manufacturing Manufacturing is the creation or production of goods with the help of equipment, labor, machines, tools, and chemical or biological processing or formulation. It is the essence of secondary sector of the economy. The term may refer to ...
, healthcare and clinical applications such as blood chemistry; and many other applications. Advances in the instrumentation and in detection have expanded the number of applications in which pH measurements can be conducted. The devices have been miniaturized, enabling direct measurement of pH inside of
living cells The cell is the basic structural and functional unit of life forms. Every cell consists of a cytoplasm enclosed within a membrane, and contains many biomolecules such as proteins, DNA and RNA, as well as many small molecules of nutrients ...
. In addition to measuring the pH of liquids, specially designed electrodes are available to measure the pH of semi-solid substances, such as foods. These have tips suitable for piercing semi-solids, have electrode materials compatible with ingredients in food, and are resistant to clogging.


Design and use


Principle of operation

Potentiometric pH meters measure the voltage between two electrodes and display the result converted into the corresponding pH value. They comprise a simple electronic amplifier and a pair of electrodes, or alternatively a combination electrode, and some form of display calibrated in pH units. It usually has a glass electrode and a
reference electrode A reference electrode is an electrode which has a stable and well-known electrode potential. The high stability of the electrode potential is usually reached by employing a redox system with constant (buffered or saturated) concentrations of ea ...
, or a combination electrode. The electrodes, or probes, are inserted into the solution to be tested. pH meters may also be based on the
antimony electrode The antimony electrode has been investigated for its ability to function as a pH electrode.Bates, Roger G. ''Determination of pH: theory and practice''. Wiley, 1973, pp 252-256 The electrode is made of elemental antimony. The electrochemical pr ...
(typpically used for rough conditions) or the quinhydrone electrode. In order to accurately measure the potential difference between the two sides of the glass membrane
reference electrode A reference electrode is an electrode which has a stable and well-known electrode potential. The high stability of the electrode potential is usually reached by employing a redox system with constant (buffered or saturated) concentrations of ea ...
, typically a silver chloride electrode or calomel electrode are required on each side of the membrane. Their purpose is to measure changes in the potential on their respective side. One is built into the glass electrode. The other, which makes contact with the test solution through a porous plug, may be a separate reference electrode or may be built into a combination electrode. The resulting voltage will be the potential difference between the two sides of the glass membrane possibly offset by some difference between the two reference electrodes, that can be compensated for. The article on the glass electrode has a good description and figure. The design of the electrodes is the key part: These are rod-like structures usually made of glass, with a bulb containing the sensor at the bottom. The glass electrode for measuring the pH has a glass bulb specifically designed to be selective to hydrogen-ion concentration. On immersion in the solution to be tested, hydrogen ions in the test solution exchange for other positively charged ions on the glass bulb, creating an electrochemical potential across the bulb. The electronic amplifier detects the difference in electrical potential between the two electrodes generated in the measurement and converts the potential difference to pH units. The magnitude of the electrochemical potential across the glass bulb is linearly related to the pH according to the Nernst equation. The
reference electrode A reference electrode is an electrode which has a stable and well-known electrode potential. The high stability of the electrode potential is usually reached by employing a redox system with constant (buffered or saturated) concentrations of ea ...
is insensitive to the pH of the solution, being composed of a metallic conductor, which connects to the display. This conductor is immersed in an electrolyte solution, typically potassium chloride, which comes into contact with the test solution through a porous ceramic membrane. The display consists of a
voltmeter A voltmeter is an instrument used for measuring electric potential difference between two points in an electric circuit. It is connected in parallel. It usually has a high resistance so that it takes negligible current from the circuit. ...
, which displays voltage in units of pH. On immersion of the glass electrode and the reference electrode in the test solution, an
electrical circuit An electrical network is an interconnection of electrical components (e.g., batteries, resistors, inductors, capacitors, switches, transistors) or a model of such an interconnection, consisting of electrical elements (e.g., voltage source ...
is completed, in which there is a potential difference created and detected by the voltmeter. The circuit can be thought of as going from the conductive element of the reference electrode to the surrounding potassium-chloride solution, through the ceramic membrane to the test solution, the hydrogen-ion-selective glass of the glass electrode, to the solution inside the glass electrode, to the silver of the glass electrode, and finally the voltmeter of the display device. The voltage varies from test solution to test solution depending on the potential difference created by the difference in hydrogen-ion concentrations on each side of the glass membrane between the test solution and the solution inside the glass electrode. All other potential differences in the circuit do not vary with pH and are corrected for by means of the calibration. For simplicity, many pH meters use a combination probe, constructed with the glass electrode and the reference electrode contained within a single probe. A detailed description of combination electrodes is given in the article on glass electrodes. The pH meter is calibrated with solutions of known pH, typically before each use, to ensure
accuracy Accuracy and precision are two measures of '' observational error''. ''Accuracy'' is how close a given set of measurements ( observations or readings) are to their '' true value'', while ''precision'' is how close the measurements are to each o ...
of measurement.Bitesize Bio: How to Care for Your pH Meter
Steffi Magub, 18 May 2012.
To measure the pH of a solution, the electrodes are used as probes, which are dipped into the test solutions and held there sufficiently long for the hydrogen ions in the test solution to equilibrate with the ions on the surface of the bulb on the glass electrode. This equilibration provides a stable pH measurement.


pH electrode and reference electrode design

Details of the fabrication and resulting microstructure of the glass membrane of the pH electrode are maintained as
trade secrets Trade secrets are a type of intellectual property that includes formulas, practices, processes, designs, instruments, patterns, or compilations of information that have inherent economic value because they are not generally known or readily a ...
by the manufacturers. However, certain aspects of design are published. Glass is a solid electrolyte, for which alkali-metal ions can carry current. The pH-sensitive glass membrane is generally spherical to simplify the manufacture of a uniform membrane. These membranes are up to 0.4 millimeters in thickness, thicker than original designs, so as to render the probes durable. The glass has
silicate In chemistry, a silicate is any member of a family of polyatomic anions consisting of silicon and oxygen, usually with the general formula , where . The family includes orthosilicate (), metasilicate (), and pyrosilicate (, ). The name is a ...
chemical functionality on its surface, which provides binding sites for alkali-metal ions and hydrogen ions from the solutions. This provides an ion-exchange capacity in the range of 10−6 to 10−8 mol/cm2. Selectivity for hydrogen ions (H+) arises from a balance of ionic charge, volume requirements versus other ions, and the coordination number of other ions. Electrode manufacturers have developed compositions that suitably balance these factors, most notably lithium glass. The silver chloride electrode is most commonly used as a
reference electrode A reference electrode is an electrode which has a stable and well-known electrode potential. The high stability of the electrode potential is usually reached by employing a redox system with constant (buffered or saturated) concentrations of ea ...
in pH meters, although some designs use the
saturated calomel electrode The saturated calomel electrode (SCE) is a reference electrode based on the reaction between elemental mercury and mercury(I) chloride. It has been widely replaced by the silver chloride electrode, however the calomel electrode has a reputation o ...
. The silver chloride electrode is simple to manufacture and provides high
reproducibility Reproducibility, also known as replicability and repeatability, is a major principle underpinning the scientific method. For the findings of a study to be reproducible means that results obtained by an experiment or an observational study or in ...
. The reference electrode usually consists of a platinum wire that has contact with a silver/silver chloride mixture, which is immersed in a potassium chloride solution. There is a ceramic plug, which serves as a contact to the test solution, providing low resistance while preventing mixing of the two solutions. With these electrode designs, the voltmeter is detecting potential differences of ±1400 millivolts. The electrodes are further designed to rapidly equilibrate with test solutions to facilitate
ease of use Usability can be described as the capacity of a system to provide a condition for its users to perform the tasks safely, effectively, and efficiently while enjoying the experience. In software engineering, usability is the degree to which a soft ...
. The equilibration times are typically less than one second, although equilibration times increase as the electrodes age.


Maintenance

Because of the sensitivity of the electrodes to contaminants, cleanliness of the probes is essential for
accuracy and precision Accuracy and precision are two measures of ''observational error''. ''Accuracy'' is how close a given set of measurements ( observations or readings) are to their '' true value'', while ''precision'' is how close the measurements are to each ot ...
. Probes are generally kept moist when not in use with a medium appropriate for the particular probe, which is typically an aqueous solution available from probe manufacturers. Probe manufacturers provide instructions for cleaning and maintaining their probe designs. For illustration, one maker of laboratory-grade pH gives cleaning instructions for specific contaminants: general cleaning (15-minute soak in a solution of bleach and detergent), salt (hydrochloric acid solution followed by sodium hydroxide and water), grease (detergent or methanol), clogged reference junction (KCl solution), protein deposits (pepsin and HCl, 1% solution), and air bubbles.MRC lab: How to Store, Clean, and Recondition pH Electrodes


Calibration and operation

The German Institute for Standardization publishes a standard for pH measurement using pH meters, DIN 19263. Very precise measurements necessitate that the pH meter is calibrated before each measurement. More typically calibration is performed once per day of operation. Calibration is needed because the glass electrode does not give reproducible
electrostatic potential Electrostatics is a branch of physics that studies electric charges at rest ( static electricity). Since classical times, it has been known that some materials, such as amber, attract lightweight particles after rubbing. The Greek word for a ...
s over longer periods of time. Consistent with principles of good laboratory practice, calibration is performed with at least two standard buffer solutions that span the range of pH values to be measured. For general purposes, buffers at pH 4.00 and pH 10.00 are suitable. The pH meter has one calibration control to set the meter reading equal to the value of the first standard buffer and a second control to adjust the meter reading to the value of the second buffer. A third control allows the temperature to be set. Standard buffer sachets, available from a variety of suppliers, usually document the temperature dependence of the buffer control. More precise measurements sometimes require calibration at three different pH values. Some pH meters provide built-in temperature-coefficient correction, with temperature thermocouples in the electrode probes. The calibration process correlates the voltage produced by the probe (approximately 0.06 volts per pH unit) with the pH scale. Good laboratory practice dictates that, after each measurement, the probes are rinsed with distilled water or
deionized water Purified water is water that has been mechanically filtered or processed to remove impurities and make it suitable for use. Distilled water was, formerly, the most common form of purified water, but, in recent years, water is more frequently pu ...
to remove any traces of the solution being measured, blotted with a scientific wipe to absorb any remaining water, which could dilute the sample and thus alter the reading, and then immersed in a storage solution suitable for the particular probe type.


Types of pH meters

In general there are three major categories of pH meters. Benchtop pH meters are often used in laboratories and are used to measure samples which are brought to the pH meter for analysis. Portable, or field pH meters, are handheld pH meters that are used to take the pH of a sample in a field or production site. In-line or in situ pH meters, also called pH analyzers, are used to measure pH continuously in a process, and can stand-alone, or be connected to a higher level information system for process control. pH meters range from simple and inexpensive pen-like devices to complex and expensive laboratory instruments with computer interfaces and several inputs for indicator and temperature measurements to be entered to adjust for the variation in pH caused by temperature. The output can be digital or analog, and the devices can be battery-powered or rely on line power. Some versions use telemetry to connect the electrodes to the voltmeter display device. Specialty meters and probes are available for use in special applications, such as harsh environments and biological microenvironments. There are also holographic pH sensors, which allow pH measurement colorimetrically, making use of the variety of
pH indicators A pH indicator is a halochromic chemical compound added in small amounts to a solution so the pH (acidity or basicity) of the solution can be determined visually or spectroscopically by changes in absorption and/or emission properties. Hence ...
that are available. Additionally, there are commercially available pH meters based on solid state electrodes, rather than conventional glass electrodes.


History

The concept of pH was defined in 1909 by S. P. L. Sørensen, and electrodes were used for pH measurement in the 1920s. In October 1934, Arnold Orville Beckman registered the first patent for a complete chemical instrument for the measurement of pH, U.S. Patent No. 2,058,761, for his "acidimeter", later renamed the pH meter. Beckman developed the prototype as an assistant professor of chemistry at the
California Institute of Technology The California Institute of Technology (branded as Caltech or CIT)The university itself only spells its short form as "Caltech"; the institution considers other spellings such a"Cal Tech" and "CalTech" incorrect. The institute is also occasional ...
, when asked to devise a quick and accurate method for measuring the acidity of
lemon The lemon (''Citrus limon'') is a species of small evergreen trees in the flowering plant family Rutaceae, native to Asia, primarily Northeast India (Assam), Northern Myanmar or China. The tree's ellipsoidal yellow fruit is used for culin ...
juice for the California Fruit Growers Exchange ( Sunkist). On April 8, 1935, Beckman's renamed National Technical Laboratories focused on the manufacture of scientific instruments, with the Arthur H. Thomas Company as a distributor for its pH meter. In its first full year of sales, 1936, the company sold 444 pH meters for $60,000 in sales. In years to come, the company sold millions of the units. In 2004 the Beckman pH meter was designated an ACS National Historic Chemical Landmark in recognition of its significance as the first commercially successful electronic pH meter. The
Radiometer A radiometer or roentgenometer is a device for measuring the radiant flux (power) of electromagnetic radiation. Generally, a radiometer is an infrared radiation detector or an ultraviolet detector. Microwave radiometers operate in the microwave ...
Corporation of Denmark was founded in 1935, and began marketing a pH meter for medical use around 1936, but "the development of automatic pH-meters for industrial purposes was neglected. Instead American instrument makers successfully developed industrial pH-meters with a wide variety of applications, such as in breweries, paper works, alum works, and water treatment systems." In the 1940s the electrodes for pH meters were often difficult to make, or unreliable due to brittle glass. Dr. Werner Ingold began to industrialize the production of single-rod measuring cells, a combination of measurement and reference electrode in one construction unit, which led to broader acceptance in a wide range of industries including pharmaceutical production. Beckman marketed a portable "Pocket pH Meter" as early as 1956, but it did not have a digital read-out. In the 1970s Jenco Electronics of
Taiwan Taiwan, officially the Republic of China (ROC), is a country in East Asia, at the junction of the East and South China Seas in the northwestern Pacific Ocean, with the People's Republic of China (PRC) to the northwest, Japan to the no ...
designed and manufactured the first portable digital pH meter. This meter was sold under the label of the Cole-Parmer Corporation.


Building a pH meter

Specialized manufacturing is required for the electrodes, and details of their design and construction are typically trade secrets. However, with purchase of suitable electrodes, a standard
multimeter A multimeter is a measuring instrument that can measure multiple electrical properties. A typical multimeter can measure voltage, resistance, and current, in which case it is also known as a volt-ohm-milliammeter (VOM), as the unit is equipped w ...
can be used to complete the construction of the pH meter. However, commercial suppliers offer voltmeter displays that simplify use, including calibration and temperature compensation.


See also

*
Antimony electrode The antimony electrode has been investigated for its ability to function as a pH electrode.Bates, Roger G. ''Determination of pH: theory and practice''. Wiley, 1973, pp 252-256 The electrode is made of elemental antimony. The electrochemical pr ...
* Ion-selective electrodes * ISFET pH electrode * Potentiometry * Quinhydrone electrode *
Saturated calomel electrode The saturated calomel electrode (SCE) is a reference electrode based on the reaction between elemental mercury and mercury(I) chloride. It has been widely replaced by the silver chloride electrode, however the calomel electrode has a reputation o ...
* Silver chloride electrode * Standard hydrogen electrode


References


External links


Introduction to pH measurement
– Overview of pH and pH measurement at the Omega Engineering website

– National Historic Chemical Landmark of the American Chemical Society
pH Measurement Handbook
- A publication of the Thermo-Scientific Co. {{DEFAULTSORT:Ph Meter Acid–base chemistry Electrochemistry Measuring instruments Scientific instruments