Oscilloscope history
   HOME

TheInfoList



OR:

Illustration of Joubert's step-by-step method of hand-plotting waveform measurements The history of the oscilloscope was fundamental to science because an oscilloscope is a device for viewing waveform oscillations, as of electrical voltage or current, in order to measure frequency and other wave characteristics. This was important in developing electromagnetic theory. The first recordings of waveforms were with a
galvanometer A galvanometer is an electromechanical measuring instrument for electric current. Early galvanometers were uncalibrated, but improved versions, called ammeters, were calibrated and could measure the flow of current more precisely. A galvan ...
coupled to a mechanical drawing system dating from the second decade of the 19th century. The modern day digital
oscilloscope An oscilloscope (informally a scope) is a type of electronic test instrument that graphically displays varying electrical voltages as a two-dimensional plot of one or more signals as a function of time. The main purposes are to display repetiti ...
is a consequence of multiple generations of development of the oscillograph,
cathode-ray tube A cathode-ray tube (CRT) is a vacuum tube containing one or more electron guns, which emit electron beams that are manipulated to display images on a Phosphorescence, phosphorescent screen. The images may represent electrical waveforms (osci ...
s, analog oscilloscopes, and
digital electronics Digital electronics is a field of electronics involving the study of digital signals and the engineering of devices that use or produce them. This is in contrast to analog electronics and analog signals. Digital electronic circuits are usu ...
.


Hand-drawn oscillograms

The earliest method of creating an image of a waveform was through a laborious and painstaking process of measuring the voltage or current of a spinning rotor at specific points around the axis of the rotor, and noting the measurements taken with a
galvanometer A galvanometer is an electromechanical measuring instrument for electric current. Early galvanometers were uncalibrated, but improved versions, called ammeters, were calibrated and could measure the flow of current more precisely. A galvan ...
. By slowly advancing around the rotor, a general standing wave can be drawn on graphing paper by recording the degrees of rotation and the meter strength at each position. This process was first partially automated by with his ''step-by-step'' method of wave form measurement. This consisted of a special single-contact
commutator In mathematics, the commutator gives an indication of the extent to which a certain binary operation fails to be commutative. There are different definitions used in group theory and ring theory. Group theory The commutator of two elements, ...
attached to the shaft of a spinning rotor. The contact point could be moved around the rotor following a precise degree indicator scale and the output appearing on a galvanometer, to be hand-graphed by the technician. This process could only produce a very rough waveform approximation since it was formed over a period of several thousand wave cycles, but it was the first step in the science of waveform imaging.


Automatic paper-drawn oscillograph

The first automated oscillographs used a galvanometer to move a pen across a scroll or drum of paper, capturing wave patterns onto a continuously moving scroll. Due to the relatively high-frequency speed of the waveforms compared to the slow reaction time of the mechanical components, the waveform image was not drawn directly but instead built up over a period of time by combining small pieces of many different waveforms, to create an averaged shape. The device known as the Hospitalier Ondograph was based on this method of wave form measurement. It automatically charged a capacitor from each 100th wave, and discharged the stored energy through a recording galvanometer, with each successive charge of the capacitor being taken from a point a little farther along the wave. (Such wave-form measurements were still averaged over many hundreds of wave cycles but were more accurate than hand-drawn oscillograms.)


Photographic oscillograph

Film recording of sparking across switch contacts, as a high-voltage circuit is disconnected In order to permit direct measurement of waveforms it was necessary for the recording device to use a very low-mass measurement system that can move with sufficient speed to match the motion of the actual waves being measured. This was done with the development of the ''moving-coil oscillograph'' by
William Duddell William Du Bois Duddell (1 July 1872, in Kensington, London – 4 November 1917, in Wandsworth, London) was an English physicist and electrical engineer. His inventions include the moving coil oscillograph, as well as the thermo-ammeter and ...
which in modern times is also referred to as a mirror galvanometer. This reduced the measurement device to a small mirror that could move at high speeds to match the waveform. To perform a waveform measurement, a photographic slide would be dropped past a window where the light beam emerges, or a continuous roll of motion picture film would be scrolled across the aperture to record the waveform over time. Although the measurements were much more precise than the built-up paper recorders, there was still room for improvement due to having to develop the exposed images before they could be examined.


Tilting mirror

In the 1920s, a tiny tilting mirror attached to a diaphragm at the apex of a horn provided good response up to a few kHz, perhaps even 10 kHz. A time base, unsynchronized, was provided by a spinning mirror polygon, and a collimated beam of light from an arc lamp projected the waveform onto the lab wall or a screen. Even earlier, audio applied to a diaphragm on the gas feed to a flame made the flame height vary, and a spinning mirror polygon gave an early glimpse of waveforms. Moving-paper oscillographs using UV-sensitive paper and advanced mirror galvanometers provided multi-channel recordings in the mid-20th century. Frequency response was into at least the low audio range.


CRT invention

file:CRT oscilloscope.png, The interior of a
cathode-ray tube A cathode-ray tube (CRT) is a vacuum tube containing one or more electron guns, which emit electron beams that are manipulated to display images on a Phosphorescence, phosphorescent screen. The images may represent electrical waveforms (osci ...
for use in an oscilloscope. 1. Deflection voltage electrode; 2. Electron gun; 3. Electron beam; 4. Focusing coil; 5. Phosphor-coated inner side of the screen Cathode ray tubes (CRTs) were developed in the late 19th century. At that time, the tubes were intended primarily to demonstrate and explore the physics of electrons (then known as cathode rays).
Karl Ferdinand Braun Karl Ferdinand Braun (; 6 June 1850 – 20 April 1918) was a German electrical engineer, inventor, physicist and Nobel laureate in physics. Braun contributed significantly to the development of radio and television technology: he shared the ...
invented the CRT oscilloscope as a physics curiosity in 1897, by applying an oscillating signal to electrically charged deflector plates in a
phosphor A phosphor is a substance that exhibits the phenomenon of luminescence; it emits light when exposed to some type of radiant energy. The term is used both for fluorescent or phosphorescent substances which glow on exposure to ultraviolet or v ...
-coated CRT. Braun tubes were laboratory apparatus, using a cold-cathode emitter and very high voltages (on the order of 20,000 to 30,000 volts). With only vertical deflection applied to the internal plates, the face of the tube was observed through a rotating mirror to provide a horizontal time base. In 1899 Jonathan Zenneck equipped the cathode ray tube with beam-forming plates and used a magnetic field for sweeping the trace. Early cathode ray tubes had been applied experimentally to laboratory measurements as early as 1919 but suffered from poor stability of the vacuum and the cathode emitters. The application of a thermionic emitter allowed operating voltage to be dropped to a few hundred volts.
Western Electric The Western Electric Company was an American electrical engineering and manufacturing company officially founded in 1869. A wholly owned subsidiary of American Telephone & Telegraph for most of its lifespan, it served as the primary equipment ma ...
introduced a commercial tube of this type, which relied on a small amount of gas within the tube to assist in focusing the electron beam. V. K. Zworykin described a permanently sealed, high-vacuum cathode ray tube with a thermionic emitter in 1931. This stable and reproducible component allowed
General Radio General Radio Company (later, GenRad) was a broad-line manufacturer of electronic test equipment in Massachusetts, U.S. from 1915 to 2001. History On June 14, 1915, Melville Eastham and a small group of investors started General Radio Company ...
to manufacture an oscilloscope that was usable outside a laboratory setting. The first dual-beam oscilloscope was developed in the late 1930s by the British company A.C.Cossor (later acquired by
Raytheon Raytheon Technologies Corporation is an American multinational aerospace and defense conglomerate headquartered in Arlington, Virginia. It is one of the largest aerospace and defense manufacturers in the world by revenue and market capitali ...
). The CRT was not a true double beam type but used a split beam made by placing a third plate between the vertical deflection plates. It was widely used during WWII for the development and servicing of
radar Radar is a detection system that uses radio waves to determine the distance (''ranging''), angle, and radial velocity of objects relative to the site. It can be used to detect aircraft, Marine radar, ships, spacecraft, guided missiles, motor v ...
equipment. Although extremely useful for examining the performance of pulse circuits it was not calibrated so could not be used as a measuring device. It was, however, useful in producing response curves of IF circuits and consequently a great aid in their accurate alignment. Allen B. Du Mont Labs. made moving-film cameras, in which continuous film motion provided the time base. Horizontal deflection was probably disabled, although a very slow sweep would have spread phosphor wear. CRTs with P11 phosphor were either standard or available. Long-persistence CRTs, sometimes used in oscilloscopes for displaying slowly changing signals or single-shot events, used a phosphor such as P7, which comprised a double layer. The inner layer fluoresced bright blue from the electron beam, and its light excited a phosphorescent "outer" layer, directly visible inside the envelope (bulb). The latter stored the light, and released it with a yellowish glow with decaying brightness over tens of seconds. This type of phosphor was also used in radar analog PPI CRT displays, which are a graphic decoration (rotating radial light bar) in some TV weather-report scenes.


Sweep circuit

file:Heathkit Oscilloscope OM-2.jpg, upleft, Oscilloscope with synchronized sweep. "HOR. SELECTOR" sets horizontal frequency range (the capacitor); "FREQ. VERNIER" adjusts the free-running frequency; "SYNC. AMPLITUDE" sets the gain to the comparator The technology for the horizontal sweep, that portion of the oscilloscope that creates the horizontal time axis, has changed.


Synchronized sweep

Early oscilloscopes used a synchronized sawtooth waveform generator to provide the time axis. The sawtooth would be made by charging a capacitor with a relatively constant current; that would create a rising voltage. The rising voltage would be fed to the horizontal deflection plates to create the sweep. The rising voltage would also be fed to a comparator; when the capacitor reached a certain level, the capacitor would be discharged, the trace would return to the left, and the capacitor (and the sweep) would start another traverse. The operator would adjust the charging current so the sawtooth generator would have a slightly longer period than a multiple of the vertical axis signal. For example, when looking at a 1 kHz sinewave (1 ms period), the operator might adjust the horizontal frequency to a little bit more than 5 ms. When the input signal was absent, the sweep would free run at that frequency. If the input signal were present, the resulting display would not be stable at the horizontal sweep's free-running frequency because it was not a submultiple of the input (vertical axis) signal. To fix that, the sweep generator would be synchronized by adding a scaled version of the input the signal to the sweep generator's comparator. The added signal would cause the comparator to trip a little earlier and thus synchronize it to the input signal. The operator could adjust the synch level; for some designs, the operator could choose the polarity. The sweep generator would turn off (known as blanking) the beam during retrace. The resulting horizontal sweep speed was uncalibrated because the sweep rate was adjusted by changing slope of the sawtooth generator. The time per division on the display depended upon the sweep's free-running frequency and a horizontal gain control. A synchronized sweep oscilloscope could not display a non-periodic signal because it could not synchronize the sweep generator to that signal. Horizontal circuits were often AC-coupled


Triggered sweep

Triggered sweep controls on a Tektronix 465 oscilloscope During World War II, a few oscilloscopes used for radar development (and a few laboratory oscilloscopes) had so-called driven sweeps. These sweep circuits remained dormant, with the CRT beam cut off, until a drive pulse from an external device unblanked the CRT and started a constant-speed horizontal trace; the calibrated speed permitted measurement of time intervals. When the sweep was complete, the sweep circuit blanked the CRT (turned off the beam), reset itself, and waited for the next drive pulse. The Dumont 248, a commercially available oscilloscope produced in 1945, had this feature. Oscilloscopes became a much more useful tool in 1946 when Howard Vollum and
Melvin Jack Murdock Melvin "Jack" Murdock (August 15, 1917 – May 16, 1971) was an American businessman, philanthropist, and radio technician from Portland, Oregon. He was a co-founder of Tektronix, Inc. Background Murdock was born in Portland, Oregon, on August ...
introduced the Tektronix Model 511 ''triggered-sweep'' oscilloscope. Howard Vollum had first seen this technology in use in Germany. The triggered sweep has a circuit that develops the driven sweep's drive pulse from the input signal. Triggering allows stationary display of a repeating waveform, as multiple repetitions of the waveform are drawn over exactly the same trace on the phosphor screen. A triggered sweep maintains the calibration of sweep speed, making it possible to measure properties of the waveform such as frequency, phase, rise time, and others, that would not otherwise be possible. Furthermore, triggering can occur at varying intervals, so there is no requirement that the input signal be periodic. Triggered-sweep oscilloscopes compare the vertical deflection signal (or rate of change of the signal) with an adjustable threshold, referred to as trigger level. As well, the trigger circuits also recognize the slope direction of the vertical signal when it crosses the threshold—whether the vertical signal is positive-going or negative-going at the crossing. This is called trigger polarity. When the vertical signal crosses the set trigger level and in the desired direction, the trigger circuit unblanks the CRT and starts an accurate linear sweep. After the completion of the horizontal sweep, the next sweep will occur when the signal once again crosses the threshold trigger. Variations in triggered-sweep oscilloscopes include models offered with CRTs using long-persistence phosphors, such as type P7. These oscilloscopes were used for applications where the horizontal trace speed was very slow, or there was a long delay between sweeps, to provide a persistent screen image. Oscilloscopes without triggered sweep could also be retro-fitted with triggered sweep using a solid-state circuit developed by Harry Garland and
Roger Melen Roger Douglas Melen (born 1946) is an electrical engineer recognized for his early contributions to the microcomputer industry, and for his technical innovations. Dr. Melen was co-founder of Cromemco, one of the earliest microcomputer companies ...
in 1971. As oscilloscopes have become more powerful over time, enhanced triggering options allow capture and display of more complex waveforms. For example, '' trigger holdoff'' is a feature in most modern oscilloscopes that can be used to define a certain period following a trigger during which the oscilloscope will not trigger again. This makes it easier to establish a stable view of a waveform with multiple edges which would otherwise cause another trigger.


Tektronix

Type 465 Tektronix oscilloscope, a popular analog oscilloscope during the 1980s Vollum and Murdock went on to found
Tektronix Tektronix, Inc., historically widely known as Tek, is an American company best known for manufacturing test and measurement devices such as oscilloscopes, logic analyzers, and video and mobile test protocol equipment. Originally an independent ...
, the first manufacturer of calibrated oscilloscopes (which included a
graticule Graticule may refer to: * An oscilloscope graticule scale * The reticle pattern in an optical instrument * Graticule (cartography), a grid of lines on a map See also * Grid (disambiguation) Grid, The Grid, or GRID may refer to: Common us ...
on the screen and produced plots with calibrated scales on the
axes Axes, plural of '' axe'' and of '' axis'', may refer to * ''Axes'' (album), a 2005 rock album by the British band Electrelane * a possibly still empty plot (graphics) See also * Axess (disambiguation) *Axxess (disambiguation) Axxess may refer to ...
of the screen). Later developments by Tektronix included the development of multiple-trace oscilloscopes for comparing signals either by time-
multiplexing In telecommunications and computer networking, multiplexing (sometimes contracted to muxing) is a method by which multiple analog or digital signals are combined into one signal over a shared medium. The aim is to share a scarce resource - ...
(via chopping or trace alternation) or by the presence of multiple
electron gun An electron gun (also called electron emitter) is an electrical component in some vacuum tubes that produces a narrow, collimated electron beam that has a precise kinetic energy. The largest use is in cathode-ray tubes (CRTs), used in nearly ...
s in the tube. In 1963, Tektronix introduced the Direct View Bistable Storage Tube (DVBST), which allowed observing single pulse waveforms rather than (as previously) only repeating wave forms. Using micro-channel plates, a variety of secondary-emission electron multiplier inside the CRT and behind the faceplate, the most advanced analog oscilloscopes (for example, the Tek 7104 mainframe) could display a visible trace (or allow the photography) of a single-shot event even when running at extremely fast sweep speeds. This oscilloscope went to 1 GHz. In vacuum-tube oscilloscopes made by Tektronix, the vertical amplifier's delay line was a long frame, L-shaped for space reasons, that carried several dozen discrete inductors and a corresponding number of low-capacitance adjustable ("trimmer") cylindrical capacitors. These oscilloscopes had plug-in vertical input channels. For adjusting the delay line capacitors, a high-pressure gas-filled mercury-wetted reed switch created extremely fast-rise pulses which went directly to the later stages of the vertical amplifier. With a fast sweep, any misadjustment created a dip or bump, and touching a capacitor made its local part of the waveform change. Adjusting the capacitor made its bump disappear. Eventually, a flat top resulted. Vacuum-tube output stages in early wideband oscilloscopes used radio transmitting tubes, but they consumed a lot of power. Picofarads of capacitance to ground limited bandwidth. A better design, called a
distributed amplifier Distributed amplifiers are circuit designs that incorporate transmission line theory into traditional amplifier design to obtain a larger gain-bandwidth product than is realizable by conventional circuits. History The design of the distribu ...
, used multiple tubes, but their inputs (control grids) were connected along a tapped L-C delay line, so the tubes' input capacitances became part of the delay line. As well, their outputs (plates/anodes) were likewise connected to another tapped delay line, its output feeding the deflection plates. This amplifier was often push-pull, so there were four delay lines, two for input (grid), and two for output (plate).


Digital oscilloscopes

The first
digital storage oscilloscope A digital storage oscilloscope (DSO) is an oscilloscope which stores and analyses the input signal digitally rather than using analog techniques. It is now the most common type of oscilloscope in use because of the advanced trigger, storage, ...
(DSO) was built by Nicolet Test Instrument of Madison, Wisconsin. It used a low-speed analog-to-digital converter (1 MHz, 12 bit) used primarily for vibration and medical analysis. The first high-speed DSO (100 MHz, 8 bit) was developed by Walter LeCroy, who founded the LeCroy Corporation of New York, USA, after producing high-speed digitizers for the research center
CERN The European Organization for Nuclear Research, known as CERN (; ; ), is an intergovernmental organization that operates the largest particle physics laboratory in the world. Established in 1954, it is based in a northwestern suburb of Gen ...
in Switzerland. LeCroy (since 2012 Teledyne LeCroy) remains one of the three largest manufacturers of oscilloscopes in the world. Starting in the 1980s,
digital Digital usually refers to something using discrete digits, often binary digits. Technology and computing Hardware *Digital electronics, electronic circuits which operate using digital signals ** Digital camera, which captures and stores digital ...
oscilloscopes became prevalent. Digital storage oscilloscopes use a fast
analog-to-digital converter In electronics, an analog-to-digital converter (ADC, A/D, or A-to-D) is a system that converts an analog signal, such as a sound picked up by a microphone or light entering a digital camera, into a digital signal. An ADC may also provide ...
and memory chips to record and show a digital representation of a waveform, yielding much more flexibility for triggering, analysis, and display than is possible with a classic analog oscilloscope. Unlike its analog predecessor, the digital storage oscilloscope can show pre-trigger events, opening another dimension to the recording of rare or intermittent events and
troubleshooting Troubleshooting is a form of problem solving, often applied to repair failed products or processes on a machine or a system. It is a logical, systematic search for the source of a problem in order to solve it, and make the product or process ope ...
of electronic
glitch A glitch is a short-lived fault in a system, such as a transient fault that corrects itself, making it difficult to troubleshoot. The term is particularly common in the computing and electronics industries, in circuit bending, as well as among ...
es. As of 2006 most new oscilloscopes (aside from education and a few niche markets) are digital. Digital scopes rely on effective use of the installed memory and trigger functions: not enough memory and the user will miss the events they want to examine; if the scope has a large memory but does not trigger as desired, the user will have difficulty finding the event. DSOs also led to the creation of hand-held digital oscilloscopes, useful for many test and field service applications. A hand held oscilloscope is usually a real-time oscilloscope, using a monochrome or color
liquid crystal display A liquid-crystal display (LCD) is a flat-panel display or other electronically modulated optical device that uses the light-modulating properties of liquid crystals combined with polarizers. Liquid crystals do not emit light directly but ...
for its display. Due to the rise in the prevalence of PCs, PC-based oscilloscopes have been becoming more common. The PC platform can be part of a standalone oscilloscope or as a standalone PC in combination with an external oscilloscope. With external oscilloscopes, a signal will be captured on external hardware (which includes an
analog-to-digital converter In electronics, an analog-to-digital converter (ADC, A/D, or A-to-D) is a system that converts an analog signal, such as a sound picked up by a microphone or light entering a digital camera, into a digital signal. An ADC may also provide ...
and memory) and transmitted to the computer, where it is processed and displayed.


Notes


References

* * * * * {{oscilloscopes Electronic test equipment Laboratory equipment Electronics work tools History of technology