In-water recompression (IWR) or underwater oxygen treatment is the emergency treatment of
decompression sickness Decompression sickness (abbreviated DCS; also called divers' disease, the bends, aerobullosis, and caisson disease) is a medical condition caused by dissolved gases emerging from solution as bubbles inside the body tissues during decompressio ...
(DCS) by returning the diver underwater to help the gas bubbles in the tissues, which are causing the symptoms, to resolve. It is a procedure that exposes the diver to significant
risk In simple terms, risk is the possibility of something bad happening. Risk involves uncertainty about the effects/implications of an activity with respect to something that humans value (such as health, well-being, wealth, property or the environm ...
which should be compared with the risk associated with the available options and balanced against the probable benefits. Some authorities recommend that it is only to be used when the time to
travel Travel is the movement of people between distant geographical locations. Travel can be done by foot, bicycle, automobile, train, boat, bus, airplane, ship or other means, with or without luggage, and can be one way or round trip. Travel c ...
to the nearest
recompression chamber A diving chamber is a vessel for human occupation, which may have an entrance that can be sealed to hold an internal pressure significantly higher than ambient pressure, a pressurised gas system to control the internal pressure, and a supply of ...
is too long to save the victim's life, others take a more pragmatic approach, and accept that in some circumstances IWR is the best available option. The risks may not be justified for case of mild symptoms likely to resolve spontaneously, or for cases where the diver is likely to be unsafe in the water, but in-water recompression may be justified in cases where severe outcomes are likely if not recompressed, if conducted by a competent and suitably equipped team. Carrying out in-water recompression when there is a nearby recompression chamber or without suitable equipment and training is never a desirable option. The risk of the procedure is due to the diver suffering from DCS being seriously ill and may become paralysed, unconscious or stop breathing while underwater. Any one of these events is likely to result in the diver
drowning Drowning is a type of suffocation induced by the submersion of the mouth and nose in a liquid. Most instances of fatal drowning occur alone or in situations where others present are either unaware of the victim's situation or unable to offer as ...
or asphyxiating or suffering further injury during a subsequent rescue to the surface. This risk can be reduced by improving airway security by using surface supplied gas and a helmet or full-face mask. Risk of injury during emergency surfacing is minimised by treatment on 100% oxygen, which is also the only gas with a reliable record of positive outcomes. Early recompression on oxygen has a high rate of complete resolution of symptoms, even for shallower and shorter treatment than the highly successful US Navy treatment table 6 Several schedules have been published for in-water recompression treatment, but little data on their efficacy is available. The Australian Navy tables and US Navy Tables may have the largest amount of empirical evidence supporting their efficacy.


Background

Decompression sickness (DCS) is a medical condition caused by dissolved gases emerging from
solution Solution may refer to: * Solution (chemistry), a mixture where one substance is dissolved in another * Solution (equation), in mathematics ** Numerical solution, in numerical analysis, approximate solutions within specified error bounds * Solutio ...
as bubbles inside the body tissues during decompression. DCS most commonly occurs during or soon after a decompression ascent from
underwater diving Underwater diving, as a human activity, is the practice of descending below the water's surface to interact with the environment. It is also often referred to as diving, an ambiguous term with several possible meanings, depending on contex ...
DCS and
arterial gas embolism An air embolism, also known as a gas embolism, is a blood vessel blockage caused by one or more bubbles of air or other gas in the circulatory system. Air can be introduced into the circulation during surgical procedures, lung over-expansion ...
are collectively referred to as
decompression illness Decompression Illness (DCI) comprises two different conditions caused by rapid decompression of the body. These conditions present similar symptoms and require the same initial first aid. Scuba divers are trained to ascend slowly from depth to av ...
. Since bubbles can form in, or migrate to, any part of the body, DCS can produce many symptoms, and its effects may vary from joint pain and rashes to paralysis and death. Individual susceptibility can vary from day to day, and different individuals under the same conditions may be affected differently or not at all. The severity of symptoms varies from barely noticeable to rapidly fatal. The risk of DCS caused by diving can be managed through proper decompression procedures, and contracting the condition has become uncommon. Its potential severity has driven much research to prevent it, and divers almost universally use
dive tables The practice of decompression by divers comprises the planning and monitoring of the profile indicated by the algorithms or tables of the chosen decompression model, to allow asymptomatic and harmless release of excess inert gases dissolved in ...
or dive computers to limit their exposure, to monitor their ascent speed, and to ensure theoretically adequate decompression stops. If DCS is suspected, it is treated by
hyperbaric oxygen therapy Hyperbaric medicine is medical treatment in which an ambient pressure greater than sea level atmospheric pressure is a necessary component. The treatment comprises hyperbaric oxygen therapy (HBOT), the medical use of oxygen at an ambient pressure ...
in a
recompression chamber A diving chamber is a vessel for human occupation, which may have an entrance that can be sealed to hold an internal pressure significantly higher than ambient pressure, a pressurised gas system to control the internal pressure, and a supply of ...
. Where a chamber is not accessible within a reasonable time frame, In-water recompression mat be indicated for a narrow range of presentations, if there are suitably skilled personnel and appropriate equipment available on site. Diagnosis is confirmed by a positive response to the treatment. Early treatment results in a significantly higher chance of successful recovery. Treatment of DCS utilizing the US Navy Treatment Table 6 with oxygen at 18m or an equivalent alternative is a widely recognised
standard of care In tort law, the standard of care is the only degree of prudence and caution required of an individual who is under a duty of care. The requirements of the standard are closely dependent on circumstances. Whether the standard of care has been b ...
. Ideally, treatment should take place in a chamber where there is no risk of drowning or hypothermia, and other medical problems can be managed conveniently. Significant delay to treatment, difficult transport, and facilities with limited experience may lead to consideration of on site treatment. Surface oxygen for first aid has been proven to improve the efficacy of recompression and decreased the number of recompression treatments required when administered within four hours post dive. IWR to 9 m breathing oxygen is one option that has shown success over the years IWR is not without risk and should be undertaken with certain precautions. IWR would only be suitable for an organised and disciplined group of divers with suitable equipment and practical training in the procedure. The principle behind IWR treatment is the same as that behind the treatment of DCS in a recompression chamber: an increase in ambient pressure will reduce the volume of the bubbles allowing better blood transport downstream of the bubbles. If the casualty can breathe pure
oxygen Oxygen is the chemical element with the symbol O and atomic number 8. It is a member of the chalcogen group in the periodic table, a highly reactive nonmetal, and an oxidizing agent that readily forms oxides with most elements ...
further improvements will occur because the increase in the proportion of oxygen in the blood may keep previously oxygen-starved tissues alive and the oxygen window will accelerate the removal of inert gases from the bubbles making the bubbles smaller. The unacceptable risks of oxygen toxicity convulsions can be reduced by recompressing to lower pressures and for shorter durations than otherwise preferred. Experimental work on verification of decompression tables by the US Navy Experimental Diving Unit with outcomes of symptomatic decompression sickness treated divers displaying symptoms by immediate recompression on oxygen, with 100% resolution of symptoms, and almost all cases resolved during the first treatment on Table 6, most of them during repressurisation or within the first 10 minutes at treatment depth. During the experimental work of developing the standard US Navy treatment tables 5 and 6, some experimentation was done with shorter treatment to shallower depths before standardising on 60 fsw (18 msw). This included immediate recompression on oxygen to 33 fsw (10 msw) for 30 minutes, which provided complete resolution in the majority of cases, but was not as effective as the full Table 6. Compression to 60 fsw (18 msw) would follow if symptoms did not resolve during initial treatment at 33 fsw. This previously unpublished data indicates that immediate recompression on oxygen to shallower depths for shorter periods does positively affect the probable long term outcome of decompression sickness, and compares favourably with outcomes for delayed hyperbaric treatment, and has been used as supporting evidence for new (2022) recommendations on in-water recompression. Outcomes for in-water recompression on other gas mixtures are mostly anecdotal and unsuitable for informing medical policy.(Mitchell et al Sept 2022 in press) The use of in-water oxygen at 6 meters has been shown to reduce bubble loads in divers compared to divers breathing oxygen on the surface.


Risks

Any potential benefits of using IWR for earlier recompression should be balanced against the risks. These risks are well known, and their potential mitigations are fairly well understood. The
Royal Australian Navy School of Underwater Medicine The Royal Australian Navy School of Underwater Medicine (RANSUM) is an instructor-led training course based at Sydney, Australia. History Before 1961 medical support at the diving section of HMAS ''Watson'' was provided by the District Medical ...
was charged to supervise the then non-sanctioned practice of IWR, in response to the very long delays that often occurred between the presentation of DCS and recompression treatment. The issues identified include: * Inappropriate cases for treatment, *
Oxygen toxicity Oxygen toxicity is a condition resulting from the harmful effects of breathing molecular oxygen () at increased partial pressures. Severe cases can result in cell damage and death, with effects most often seen in the central nervous system, l ...
, * Emergency termination of treatment, *
Hypothermia Hypothermia is defined as a body core temperature below in humans. Symptoms depend on the temperature. In mild hypothermia, there is shivering and mental confusion. In moderate hypothermia, shivering stops and confusion increases. In severe ...
* Adequacy of equipment in remote areas, *
Seasickness Motion sickness occurs due to a difference between actual and expected motion. Symptoms commonly include nausea, vomiting, cold sweat, headache, dizziness, tiredness, loss of appetite, and increased salivation. Complications may rarely include ...
, * Operator expertise and training, * Safety of the
diving attendant A diving team is a group of people who work together to conduct a diving operation. A characteristic of professional diving is the specification for minimum personnel for the diving support team. This typically specifies the minimum number of su ...
and the boat tenders, * Requirement for medical supervision, * Transport availability, * Misuse of equipment, * Pulmonary
barotrauma Barotrauma is physical damage to body tissues caused by a difference in pressure between a gas space inside, or contact with, the body and the surrounding gas or liquid. The initial damage is usually due to over-stretching the tissues in tensi ...
cases.


Risk management

In 2018, a group of diving medical experts issued a consensus guideline on pre-hospital decompression sickness management and concluded that IWR is only appropriate in groups that have been trained and are competent in the skills required for IWR and have appropriate equipment. Mitigation of a CNS oxygen toxicity seizure focuses on protecting the airway to prevent drowning. A full-face mask or mouthpiece retaining strap is reasonably effective though not guaranteed. Tethering the diver to prevent sinking, and providing a safety diver to accompany the diver under treatment at all times, who can recover the diver to the surface immediately in the event of a seizure are also recommended, following the recommended procedures for
recovery of a convulsing diver Beaching a casualty while providing artificial respiration Diver rescue, following an accident, is the process of avoiding or limiting further exposure to diving hazards and bringing a diver to a place of safety. A safe place is often a place w ...


Factors influencing a decision to use IWR

Recompression and hyperbaric oxygen administered in a recompression chamber are recognised as the definitive treatment for DCI, but when there is no readily available access to a suitable hyperbaric chamber, and if symptoms are significant or progressing, in-water recompression with oxygen is an option where a group of divers, including the symptomatic diver, already have the necessary equipment and relevant training and knowledge that provides a sufficient understanding of the associated risks to allow the involved parties to collectively accept responsibility for a decision to proceed with IWR. The decision of whether or not to attempt IWR depends on identifying the diver whose condition is serious enough to justify the risk, but whose clinical condition does not indicate that the risk is unacceptable. The risk may not be justified for mild DCI, if spontaneous recovery is probable whether the diver is recompressed or not, and surface oxygen is indicated for these cases. However, in these cases the risk of the recompression is also low, and early abandonment is also unlikely to cause further harm. There are no firm guidelines regarding expected delay to access of a decompression chamber, but divers generally consider a predicted delay of more than 8 hours from symptom onset to be reason to consider in-water recompression.


Environmental conditions

Water conditions, such as low temperature and rough sea state are relative contraindications, and the team must take these factors into account. Divers undergoing IWR risk becoming cold or hypothermic. They may already have done long dives in cold water, but the use of dry suits is common for such conditions, and the use of active heating systems in dry suit undergarments may be available. IWR requires a stable platform that can remain in one place for three hours. These factors should be considered when deciding whether to undertake IWR. Deteriorating condition of the diver or environmental conditions may make it necessary to abort or shorten treatment, or terminate it before full resolution. There is no known reason to assume that this would be inherently worse than not providing what treatment is possible at reasonable risk.


Indications

Indications are based on symptoms and signs of
decompression illness Decompression Illness (DCI) comprises two different conditions caused by rapid decompression of the body. These conditions present similar symptoms and require the same initial first aid. Scuba divers are trained to ascend slowly from depth to av ...
where expected benefits are likely to outweigh risk. There is a tension between conditions serious enough to justify the risks and clinical states which indicate excessive risk. Risk may not be considered justified for cases where the symptoms suggest a spontaneous recovery is likely without recompression, although the actual risk in these cases is likely to be relatively low. As of 2018 there is no widely accepted method for objectively selecting divers suitable for in-water recompression, and although remote consultation with a diving medical practitioner is advised by the Doolette and Mitchell 2018 protocol, it is likely that remote advice will vary significantly depending on who is contacted and how willing they are to accept responsibility for giving advice on a procedure with which they may have little personal experience and for which there is no clear decision tree. An attempt has been made to provide some structure to the decision process which can be useful to divers without medical training, by the technical diving certification organisation
International Association of Nitrox and Technical Divers The International Association of Nitrox and Technical Divers (IANTD) is a scuba diving organization concerned with certification and training in recreational diving, technical diving, cave diving, wreck diving, rebreather diving and diver le ...
(IANTD), which in consultation with diving medical experts, produced a decision map for field use. The system relies entirely on gross observation, omitting a detailed neurological examination. It categorises symptoms into three "tiers", which correspond roughly with perceived severity of DCI, and appropriateness of IWR in suitable conditions. Tier 1 symptoms would not be severe enough to justify IWR, but would be monitored and discussed with a remote consultant. These are generally non-specific symptoms which may or may not be of DCI, and are not an immediate or significant threat, such as headache, lethargy, or nausea. Tier 2 symptoms are severe enough to suggest IWR if they present soon after surfacing, or are progressive, but not necessarily if there is a delay of some hours and the symptoms are not progressive. IWR would be justified for tier 2 when it may prevent the development of more severe symptoms. These symptoms are likely to be of DCI, but are not likely to result in permanent injury or death if not treated. They include musculoskeletal pain, excepting symmetrical ''girdle pains'', lymphatic obstruction with subcutaneous swelling, skin rashes and paraesthesias such as tingling. Tier 3: symptoms are severe enough to justify IWR if there are no contraindications and the logistical requirements are in place.These symptoms and signs are likely to be of DCI and indicate a risk of permanent injury or death. Some of them are also contraindications to IWR. They include changes in state of consciousness, or obvious confusion, difficulty with speech, visual changes, disturbances in balance, obvious sensory loss (numbness), obvious weakness or paralysis, bladder dysfunction, (usually inability to urinate), bowel dysfunction, loss of limb coordination, shortness of breath, and bilaterally symmetrical girdle pains.


Contraindications

Symptoms of mild DCS have been described as being one or more of musculoskeletal pain, rash, subjective sensory change in a non-dermatomal distribution, and constitutional symptoms such as fatigue. Divers with only these symptoms could be adequately managed with surface oxygen, observation, and consultation with a diving physician. Exposing divers with stable mild symptoms to the risks of IWR might not be justified. In severe cases the diver may be so compromised that they could not safely endure the procedure. It may be difficult or impossible to reliably codify the decision process. Some signs of decompression illness which suggest a risk of permanent injury are nevertheless considered contraindications for IWR. Hearing loss and vertigo displayed in isolation with no other symptoms of DCI can have been caused by inner ear barotrauma rather than DCI, and inner ear barotrauma is generally considered a contraindication for recompression. Even when caused by DCI, vertigo can make in-water treatment hazardous if accompanied by nausea and vomiting. A diver with a deteriorating level of consciousness or with a persisting reduced level of consciousness should also not be recompressed in-water nor should a diver who does not want to go back down, or with a history of oxygen toxicity in the preceding dives, altered level of consciousness, shock, respiratory distress, or any physical injury or incapacitation which may make the procedure unsafe. Suspected or confirmed cases of arterial gas embolism (AGE) are generally not considered suitable for IWR due to the high probability of loss of conciousness.


Protocol

Recompression with hyperbaric oxygen administered in a recompression chamber is recognised as the standard of care for decompression sickness, but the infrastructure is expensive and may not be used very often, so many locations do not have convenient access to a suitable facility. If symptoms are significant or deteriorating, in-water recompression using oxygen is an option where groups of divers, including the symptomatic diver, have relevant prior training that allows an understanding of the associated risks and a collective informed acceptance of responsibility for the decision to proceed with treatment. Observational evidence has shown that very early recompression on oxygen usually results in good outcomes, or at least better outcomes than treatment after longer delays. Recompression on air will initially produce a compression of existing bubbles, and may produce associated clinical improvement, but bubbles will dissolve more slowly due to the lower concentration gradient, and some tissues will absorb more nitrogen. Bubbles nor completely resolved will re-expand during decompression, and may take up more gas, which may cause symptoms to recur or get worse. There is also observational evidence that IWR on air is less effective, so only oxygen is recommended as a treatment gas. The minimum team would comprise the symptomatic diver, a dive buddy to accompany the diver during the recompression, and a surface supervisor, who must all be competent at decompression procedures using 100% oxygen as the breathing gas. The team should be suitably equipped with adequate thermal protection, an adequate oxygen supply, a means of delivering oxygen at or near 100% for the duration of both underwater and surface phases of the treatment, a means of voice or written communication, and a method of keeping the diver at the appropriate depth and maintaining position. A full-face mask or mouthpiece retaining strap is strongly recommended as there is observational evidence of these devices preventing drowning of an unconscious diver underwater. surface supplied oxygen delivered to the casualty by umbilical or airline, and voice communication are desirable options as they allow the surface team members to keep control of the breathing gas supply and allow better monitoring of the diver's condition. Positive pressure masks have been recommended for use with open circuit oxygen, as giving more secure protection of the airway, after their successful use in rescuing the trapped Tham Luang cave group while anaesthetised. Although the IWR tables are shorter and shallower than most hyperbaric treatment tables, a substantial supply of oxygen is required. The US Navy tyoe 1 IWR table requires about of oxygen for a diver with a surface consumption rate of per minute, and the Type 2 table would use about . The rate of per minute may be optimistic if the diver is stressed due to injury, discomfort, or cold, or if some models of full-face mask are used. Recognised IWR protocols include the "Clipperton protocol", "Australian method", and the US Navy method for in-water recompression on oxygen. In-water recompression may not produce complete resolution of DCI, and signs or symptoms may recur. Any diver completing an in-water recompression should consult a diving medical practitioner as soon as reasonably practicable.


In-water recompression tables

Six IWR treatment tables have been published in the
scientific literature : ''For a broader class of literature, see Academic publishing.'' Scientific literature comprises scholarly publications that report original empirical and theoretical work in the natural and social sciences. Within an academic field, scie ...
. Each of these methods have several commonalities including the use of a full face mask, a tender to supervise the diver during treatment, a weighted recompression line and a means of communication. The history of the three older methods for providing oxygen at 9  msw (30  fsw) was described in great detail by Pyle and Youngblood. The fourth method for providing oxygen at 7.5 msw (25 fsw) was described by
Richard Pyle Richard Lawrence Pyle, Ph.D. (born 24 March 1967) is a scuba diver and ichthyologist working on Hawaii. Pyle discovered the principle of " Pyle stops" when decompressing from many deep dives in search of new species of fish, and has identified ...
at the 48th Annual UHMS Workshop on In-water Recompression in 1999. The Clipperton method involves recompression to 9 msw (30 fsw) while the Clipperton(a)
rebreather A rebreather is a breathing apparatus that absorbs the carbon dioxide of a user's exhaled breath to permit the rebreathing (recycling) of the substantially unused oxygen content, and unused inert content when present, of each breath. Oxygen i ...
method involves initial recompression to 30 msw (98 fsw). The treatment tables recommended for use in chambers are not suitable for in-water recompression as the oxygen partial pressures and the associated risk of oxygen toxicity are too high.


Australian in-water recompression table

The Australian IWR Tables were developed by the
Royal Australian Navy The Royal Australian Navy (RAN) is the principal naval force of the Australian Defence Force (ADF). The professional head of the RAN is Chief of Navy (CN) Vice Admiral Mark Hammond AM, RAN. CN is also jointly responsible to the Minister o ...
in the 1960s in response to their need for treatment in remote locations far away from recompression chambers. It was the shallow portion of the table developed for recompression chamber use. Initial recompression is to 30 fsw (9 msw). Oxygen is breathed during the entire treatment without any air breaks and is followed by alternating periods (12 hours) of oxygen and air breathing on the surface. Surfacing is at 4 minutes per fsw.


Clipperton in-water recompression tables

The Clipperton and Clipperton(a) methods were developed for use on a
scientific Science is a systematic endeavor that builds and organizes knowledge in the form of testable explanations and predictions about the universe. Science may be as old as the human species, and some of the earliest archeological evidence for ...
expedition to the atoll of Clipperton, 1,300 km from the Mexican coast. The two versions are based on the equipment available for treatment with the Clipperton(a) table being designed for use with rebreathers. Both methods begin with 10 minutes of surface oxygen. Recompression is to 30 fsw (9 msw) for the Clipperton IWR table, oxygen is then breathed for 60 minutes and while surfacing at 1 metre per minute without any air breaks. For the Clipperton(a) IWR table, descent is made to the initial treatment depth of 30 msw, maintaining a
partial pressure In a mixture of gases, each constituent gas has a partial pressure which is the notional pressure of that constituent gas as if it alone occupied the entire volume of the original mixture at the same temperature. The total pressure of an ideal g ...
of 1.4 ATA. and breathed at that depth for 10 minutes followed by ascent to 9 msw at 1 metre per minute. As near as possible to 100% oxygen is breathed at 9 msw for 30 minutes, followed by ascent to the surface at 1 metre per minute. Oxygen breathing on the surface for 6 hours post treatment and
intravenous Intravenous therapy (abbreviated as IV therapy) is a medical technique that administers fluids, medications and nutrients directly into a person's vein. The intravenous route of administration is commonly used for rehydration or to provide nutrie ...
hydration fluids are also administered following both treatment tables.


Hawaiian in-water recompression table

The Hawaiian IWR table was first described by Farm et al. while studying the diving habits of Hawaii's diving
fishermen A fisher or fisherman is someone who captures fish and other animals from a body of water, or gathers shellfish. Worldwide, there are about 38 million commercial and subsistence fishers and fish farmers. Fishers may be professional or recreati ...
. The initial portion of the treatment involves descent on air to the depth of relief plus 30 fsw or a maximum of 165 fsw for ten minutes. Ascent from initial treatment depth to 30 fsw occurs over 10 minutes. The diver then completes the treatment breathing oxygen and is followed by oxygen breathing on the surface for 30 minutes post treatment. The Hawaiian IWR Table with Pyle modifications can be found in the proceedings of the DAN 2008 Technical Diving Conference.


Pyle in-water recompression table

The Pyle IWR table was developed by Dr. Richard Pyle as a method for treating DCS in the field following scientific dives. This method begins with a 10-minute surface oxygen evaluation period. Compression to 25 fsw on oxygen for another 10-minute evaluation period. The table is best described by the treatment
algorithm In mathematics and computer science, an algorithm () is a finite sequence of rigorous instructions, typically used to solve a class of specific problems or to perform a computation. Algorithms are used as specifications for performing ...
. This table does include alternating air breathing periods or "air breaks".


US Navy in-water recompression tables

The
US Navy The United States Navy (USN) is the maritime service branch of the United States Armed Forces and one of the eight uniformed services of the United States. It is the largest and most powerful navy in the world, with the estimated tonnage ...
developed two IWR treatment tables. The table used depends on the symptoms diagnosed by the medical officer. Oxygen is breathed the entire treatment without any air breaks and is followed by 3 hours of oxygen breathing on the surface.


IANTD in water recompression protocol

The certification agency
International Association of Nitrox and Technical Divers The International Association of Nitrox and Technical Divers (IANTD) is a scuba diving organization concerned with certification and training in recreational diving, technical diving, cave diving, wreck diving, rebreather diving and diver le ...
(IANTD) have developed a training program for technical divers to run in water therapeutic recompression for suitably competent technical divers in remote locations, when conditions and equipment are suitable and the condition of the diver is assessed to require emergency treatment and the diver is likely to benefit sufficiently to justify the risk. Most of the time on hyperbaric oxygen is at 25 fsw (7.5 msw) Oxygen is breathed, with air breaks.


Clinical significance

In-water recompression is a clinically significant method to manage a global shortage of chamber availability for recreational, technical and scientific divers who often dive in places many hours, or days, from the nearest chamber. Minimal delay of recompression is directly related to improved outcomes, and probably to reduced mortality. Divers with the appropriate equipment and training can treat decompression sickness on-site. Such treatment may prevent long-term disability, and can reduce costs and risk to rescue personnel. In-water recompression is a viable alternative when safe and rapid transfer to a suitable recompression chamber is not practicable.


"Informal" in-water recompression

Although in-water recompression is widely regarded as risky, and to be avoided, there is increasing evidence that technical divers who surface and demonstrate mild DCS symptoms may often get back into the water and breathe pure oxygen at a depth of 20 feet (6 meters) for a period in an effort to alleviate the symptoms.
Divers Alert Network Divers Alert Network (DAN) is a group of not-for-profit organizations dedicated to improving diving safety for all divers. It was founded in Durham, North Carolina, United States, in 1980 at Duke University providing 24/7 telephonic hot-line div ...
's 2008 accident report mentions this trend, and that although the reported incidents showed very little success, " must recognize that these calls were mostly because the attempted IWR failed. In case the IWR were successful, hediver would not have called to report the event. Thus we do not know how often IWR may have been used successfully." Historically, the pearl divers of Broome, Western Australia, used decompression tables developed from personal experience, and would return to depth if symptoms of DCI developed on surfacing. These dives and recompression were done on air, using
standard diving dress Standard diving dress, also known as hard-hat or copper hat equipment, deep sea diving suit or heavy gear, is a type of diving suit that was formerly used for all relatively deep underwater work that required more than breath-hold duration, which ...
, which provides relatively good airway security. Success was variable, but some divers were treated in this way on several occasions.