medicine Medicine is the science and practice of caring for a patient, managing the diagnosis, prognosis, prevention, treatment, palliation of their injury or disease, and promoting their health. Medicine encompasses a variety of health care pr ...
, a Holter monitor (often simply Holter) is a type of ambulatory
electrocardiography Electrocardiography is the process of producing an electrocardiogram (ECG or EKG), a recording of the heart's electrical activity. It is an electrogram of the heart which is a graph of voltage versus time of the electrical activity of the hear ...
device, a portable device for cardiac monitoring (the
monitoring Monitoring may refer to: Science and technology Biology and healthcare * Monitoring (medicine), the observation of a disease, condition or one or several medical parameters over time * Baby monitoring * Biomonitoring, of toxic chemical compounds, ...
of the electrical activity of the cardiovascular system) for at least 24 hours. The Holter's most common use is for monitoring ECG
heart The heart is a muscular Organ (biology), organ in most animals. This organ pumps blood through the blood vessels of the circulatory system. The pumped blood carries oxygen and nutrients to the body, while carrying metabolic waste such as ca ...
activity (electrocardiography or ECG). Its extended recording period is sometimes useful for observing occasional cardiac
arrhythmia Arrhythmias, also known as cardiac arrhythmias, heart arrhythmias, or dysrhythmias, are irregularities in the heartbeat, including when it is too fast or too slow. A resting heart rate that is too fast – above 100 beats per minute in adult ...
s which would be difficult to identify in a shorter period. For patients having more transient symptoms, a cardiac event monitor which can be worn for a month or more can be used. The Holter monitor was developed at the Holter Research Laboratory in
Helena, Montana Helena (; ) is the capital city of Montana, United States, and the county seat of Lewis and Clark County. Helena was founded as a gold camp during the Montana gold rush, and established on October 30, 1864. Due to the gold rush, Helena would be ...
, US by experimental physicists Norman J. Holter and Bill Glasscock, who started work on radio
telemetry Telemetry is the in situ collection of measurements or other data at remote points and their automatic transmission to receiving equipment (telecommunication) for monitoring. The word is derived from the Greek roots ''tele'', "remote", an ...
in 1949. Inspired by a suggestion from cardiologist Paul Dudley White in the early 1950s, they redirected their efforts toward development of a wearable cardiac monitoring device. The Holter monitor was released for commercial production in 1962. When used to study the heart, much like standard electrocardiography, the Holter monitor records electrical signals from the heart via a series of
electrode An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials ...
s attached to the chest. Electrodes are placed over bones to minimize artifacts from muscular activity. The number and position of electrodes varies by model, but most Holter monitors employ between three and eight. These electrodes are connected to a small piece of equipment that is attached to the patient's belt or hung around the neck, keeping a log of the heart's electrical activity throughout the recording period. A 12-lead Holter system is used when precise ECG information is required to analyse the exact origin of the abnormal signals.


Data storage

Older devices used reel-to-reel tapes or a standard C90 or C120
audio cassette The Compact Cassette or Musicassette (MC), also commonly called the tape cassette, cassette tape, audio cassette, or simply tape or cassette, is an analog magnetic tape recording format for audio recording and playback. Invented by Lou Otte ...
and ran at a 1.7 mm/s or 2 mm/s speed to record the data. Once a recording was made, it could be played back and analyzed at 60x speed, so 24 hours of recording could be analyzed in 24 minutes. More modern units record an EDF-file onto digital
flash memory Flash memory is an electronic non-volatile computer memory storage medium that can be electrically erased and reprogrammed. The two main types of flash memory, NOR flash and NAND flash, are named for the NOR and NAND logic gates. Both use ...
devices. The data is uploaded into a computer which then automatically analyzes the input, counting ECG complexes, calculating summary statistics such as average, minimum and maximum heart rate, and finding candidate areas in the recording worthy of further study by the technician.


Components

Each Holter system has hardware (called monitor or recorder) for recording the signal, and software for review and analysis of the record. There may be a "patient button" on the front that the patient can press at specific instants such as on sickness, going to bed, taking pills, etc.; this records a mark that identifies the time of the action on the recording. Advanced Holter recorders are able to display the signal, useful for checking the signal quality.


Recorder

The size of the recorder differs depending on the manufacturer of the device. The average dimensions of today's Holter monitors are about 110x70x30 mm, but some are only 61x46x20 mm and weigh 99 g. Most of the devices operate with two
AA batteries AA, Aa, Double A, or Double-A may refer to: Arts, entertainment and media * '' America's Army'', a 2002 computer game published by the U.S. Army * '' Ancient Anguish'', a computer game in existence since 1992 * Aa!, a J-Pop musical group * D ...
. Most of the Holters monitor the ECG via only two or three channels. Depending on manufacturer, different lead systems and numbers of leads are used; the number of leads may be minimised for patient comfort. Two or three channel recording has been used for a long time in the Holter monitoring history; 12-channel Holters were introduced later, using either the standard 12-lead electrocardiograph or the modified (Mason-Likar) exercise lead system. These Holters can occasionally provide information similar to that of an ECG stress test examination. They are also suitable when analyzing patients after
myocardial infarction A myocardial infarction (MI), commonly known as a heart attack, occurs when blood flow decreases or stops to the coronary artery of the heart, causing damage to the heart muscle. The most common symptom is chest pain or discomfort which ma ...
. Recordings from these 12-lead monitors are of a significantly lower resolution than those from a standard 12-lead ECG, and in some cases have been shown to provide misleading ST segment representation, even though some devices allow setting the sampling frequency up to 1000 Hz for special-purpose examinations such as detection of "late potential". Another innovation is the inclusion of a triaxial movement sensor, which records the patient's physical activity and, on examination and software processing, extracts three movement statuses: sleeping, standing, or walking. Some modern devices can record spoken patient diary entries that can be listened to.


Analyzing software

After the recording of ECG signal for typically 24 hours, the signal must be analysed. A person would have to listen for the full 24 hours; instead integrated automatic analysis determines different sorts of heart beats, rhythms, etc. The success of the analysis is closely associated with the signal quality, which mainly depends upon the attachment of the electrodes to the patient's body. Incorrect attachment allows electromagnetic disturbance to add noise to the record, particularly with rapid patient movement, impeding processing. Other factors can also affect signal quality, such as muscle tremors, sampling rate and resolution of the digitized signal (high quality devices offer higher sampling frequency). The automatic analysis commonly provides the physician with information about heart beat morphology, beat interval measurement, heart rate variability, rhythm overview and patient diary (moments when the patient pressed the patient button). Advanced systems also perform spectral analysis, ischemic burden evaluation, graph of patient's activity or PQ segment analysis. Also possible is the ability to monitor and analyse
pacemaker An artificial cardiac pacemaker (or artificial pacemaker, so as not to be confused with the natural cardiac pacemaker) or pacemaker is a medical device that generates electrical impulses delivered by electrodes to the chambers of the heart ei ...
impulse detection, useful for checking pacemaker function.


History

The cardiac event monitor has been used for many years. The first devices were not portable; over time they became smaller. Then portable monitors were developed, weighing at first thirty pounds, over the years reducing to a fraction of a pound. Modern holter monitors can have no wires at all but simply a sticky patch attached to patients chest, most widely known are developed by iRhythm (Zio XT), TZ Medical (Trident),
Philips Koninklijke Philips N.V. (), commonly shortened to Philips, is a Dutch multinational conglomerate corporation that was founded in Eindhoven in 1891. Since 1997, it has been mostly headquartered in Amsterdam, though the Benelux headquarters is ...
BioTel Heart (ePatch) and BardyDx (CAM) among many others.


Gallery

File:Alex CM4000.jpg, A 5-lead placement EASI configuration Holter monitor File:Holter-Underwear.jpg, A Holter monitor can be worn for many days without causing significant discomfort. File:Holter monitor on canine.jpg, Canine Holter monitor with DogLeggs Vest File:Holter Monitor.jpg, A Holter monitor with a US quarter dollar coin to show scale File:Holter Monitor On Female With Belt.JPG, Holter monitor can be worn with bra, with no discomfort. File:Tlakový Holter.png, Holter monitoring of
blood pressure Blood pressure (BP) is the pressure of circulating blood against the walls of blood vessels. Most of this pressure results from the heart pumping blood through the circulatory system. When used without qualification, the term "blood pressure ...
File:IRhythm ZIO® XT Patch.jpg, Zio XT patch, a more modern Holter monitor containing two leads that can continuously monitor for up to 14 days File:Event Recorder relativ weit kranial 81W - CR - 001.jpg, Implantable loop recorder


See also

* BodyKom, a heart monitoring service transmitting data via the mobile cellular telephone network


References


External links


Holter monitor - MedLine Plus

Holter monitor - Biocalculus
{{Cardiac procedures American inventions Diagnostic cardiology Medical monitoring equipment