Emergency light
   HOME

TheInfoList



OR:

An emergency light is a battery-backed lighting device that switches on automatically when a building experiences a
power outage A power outage (also called a powercut, a power out, a power failure, a power blackout, a power loss, or a blackout) is the loss of the electrical power network supply to an end user. There are many causes of power failures in an electricity ...
. In the United States, emergency lights are standard in new commercial and high occupancy residential buildings, such as college
dormitories A dormitory (originated from the Latin word ''dormitorium'', often abbreviated to dorm) is a building primarily providing sleeping and residential quarters for large numbers of people such as boarding school, high school, college or university s ...
,
apartment An apartment (American English), or flat (British English, Indian English, South African English), is a self-contained housing unit (a type of residential real estate) that occupies part of a building, generally on a single story. There are ma ...
s, and
hotel A hotel is an establishment that provides paid lodging on a short-term basis. Facilities provided inside a hotel room may range from a modest-quality mattress in a small room to large suites with bigger, higher-quality beds, a dresser, a re ...
s. Most
building code A building code (also building control or building regulations) is a set of rules that specify the standards for constructed objects such as buildings and non-building structures. Buildings must conform to the code to obtain planning permissi ...
s in the US require that they be installed in older buildings as well.
Incandescent light bulb An incandescent light bulb, incandescent lamp or incandescent light globe is an electric light with a wire filament heated until it glows. The filament is enclosed in a glass bulb with a vacuum or inert gas to protect the filament from oxi ...
s were originally used in emergency lights, before fluorescent lights and later
light-emitting diode A light-emitting diode (LED) is a semiconductor Electronics, device that Light#Light sources, emits light when Electric current, current flows through it. Electrons in the semiconductor recombine with electron holes, releasing energy i ...
s (LEDs) superseded them in the 21st century.


History

By the nature of the device, an emergency light is designed to come on when the power goes out. Every model, therefore, requires some sort of a battery or generator system that could provide electricity to the lights during a blackout. The earliest models were
incandescent light bulb An incandescent light bulb, incandescent lamp or incandescent light globe is an electric light with a wire filament heated until it glows. The filament is enclosed in a glass bulb with a vacuum or inert gas to protect the filament from oxi ...
s which could dimly light an area during a blackout and perhaps provide enough light to solve the power problem or evacuate the building. It was quickly realized, however, that a more focused, brighter, and longer-lasting light was needed. The modern emergency
floodlight A floodlight is a broad-beamed, high-intensity artificial light. They are often used to illuminate outdoor playing fields while an outdoor sports event is being held during low-light conditions. More focused kinds are often used as a stage ...
provides a high- lumen, wide-coverage light that can illuminate an area quite well. Some lights are
halogen The halogens () are a group in the periodic table consisting of five or six chemically related elements: fluorine (F), chlorine (Cl), bromine (Br), iodine (I), astatine (At), and tennessine (Ts). In the modern IUPAC nomenclature, this grou ...
, and provide a light source and intensity similar to that of an
automobile A car or automobile is a motor vehicle with wheels. Most definitions of ''cars'' say that they run primarily on roads, seat one to eight people, have four wheels, and mainly transport people instead of goods. The year 1886 is regarded ...
headlight A headlamp is a lamp attached to the front of a vehicle to illuminate the road ahead. Headlamps are also often called headlights, but in the most precise usage, ''headlamp'' is the term for the device itself and ''headlight'' is the term for ...
. Early battery backup systems were huge, dwarfing the size of the lights for which they provided power. The systems normally used lead acid batteries to store a full 120-
volt The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). It is named after the Italian physicist Alessandro Volta (1745–1827). Defin ...
charge. For comparison, an
automobile A car or automobile is a motor vehicle with wheels. Most definitions of ''cars'' say that they run primarily on roads, seat one to eight people, have four wheels, and mainly transport people instead of goods. The year 1886 is regarded ...
uses a single lead acid battery as part of the ignition system. Simple
transistor upright=1.4, gate (G), body (B), source (S) and drain (D) terminals. The gate is separated from the body by an insulating layer (pink). A transistor is a semiconductor device used to Electronic amplifier, amplify or electronic switch, switch ...
or
relay A relay Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off A relay is an electrically operated switch ...
technology was used to switch on the lights and battery supply in the event of a power failure. The size of these units, as well as the weight and cost, made them relatively rare installations. As technology developed further, the voltage requirements for lights dropped, and subsequently the size of the batteries was reduced as well. Modern lights are only as large as the bulbs themselves - the battery fits quite well in the base of the fixture.


Modern installations

In the United States and Europe, modern emergency lighting is installed in virtually every commercial and high occupancy residential building. The lights consist of one or more incandescent bulbs or one or more clusters of high-intensity
light-emitting diode A light-emitting diode (LED) is a semiconductor Electronics, device that Light#Light sources, emits light when Electric current, current flows through it. Electrons in the semiconductor recombine with electron holes, releasing energy i ...
s (LED). The emergency lighting heads are usually either PAR 36 sealed beams or wedge base lamps. All units have some sort of a device to focus and intensify the light they produce. This can either be in the form of a plastic cover over the fixture, or a reflector placed behind the light source. Most individual light sources can be rotated and aimed for where light is needed most in an emergency, such as toward
fire exit An emergency exit in a structure is a special exit for emergencies such as a fire: the combined use of regular and special exits allows for faster evacuation, while it also provides an alternative if the route to the regular exit is blocked. ...
s. Modern fixtures usually have a test button of some sort which temporarily overrides the unit and causes it to switch on the lights and operate from battery power even if the main power is still on. Modern systems are operated with relatively low voltage, usually from 6-12 volts. This both reduces the size of the batteries required and reduces the load on the circuit to which the emergency light is wired. Modern fixtures include a small
transformer A transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits. A varying current in any coil of the transformer produces a varying magnetic flux in the transformer' ...
in the base of the fixture which steps-down the voltage from main current to the low voltage required by the lights. Batteries are commonly made of lead-calcium, and can last for 10 years or more on continuous charge. U.S. fire safety codes require a minimum of 90 minutes on battery power during a power outage along the path of egress.


Compliance Codes

New York City requires emergency lights to carry a Calendar Number signifying approval for local installation, Chicago requires emergency lighting to have a metal face plate, and Los Angeles requires additional exit signs be installed within of the floor around doors to mark exits during a fire, as smoke rises and tends to block out higher installed units. As there are strict requirements to provide an average of one foot candle of light along the path of egress, emergency lighting should be selected carefully to ensure codes are met. In recent years, emergency lighting has made less use of the traditional two-head unit - with manufacturers stretching the concept of emergency lighting to accommodate and integrate emergency lighting into the architecture. An emergency lighting installation may be either a central standby source such as a bank of lead acid batteries and control gear/chargers supplying slave fittings throughout the building, or may be constructed using self-contained emergency fittings which incorporate the lamp, battery, charger and control equipment. Self-contained emergency lighting fittings may operate in "Maintained" mode (illuminated all the time or controlled by a switch) or "Non-Maintained" mode (illuminated only when the normal supply fails). Some emergency lighting manufacturers offer dimming solutions for common area emergency lighting to allow energy savings for building owners when unoccupied using embedded sensors. Another popular method for lighting designers, architects and contractors are battery backup ballasts that install within or adjacent to existing lighting fixtures. Upon sensing power loss, the ballasts switch into emergency mode turning the existing lighting into emergency lighting in order to meet both the NFPA's Life Safety Code and the national Electric Code without the need of wiring separate circuits or external wall mounts. Codes of practice for remote mounted emergency lighting generally mandate that wiring from the central power source to emergency luminaires be kept segregated from other wiring, and constructed in fire resistant cabling and wiring systems. Codes of practice lay down minimum illumination levels in escape routes and open areas. Codes of practice also lay down requirements governing siting of emergency lighting fittings, for example the UK code of practice, BS5266, specifies that a fitting must be within horizontal distance of a fire alarm call point or location for fire fighting appliances. The most recent codes of practice require the designer to allow for both failure of the supply to the building and the failure of an individual lighting circuit. BS5266 requires that when Non Maintained fittings are used, they must be supplied from the same final circuit as the main lighting circuit in the area.


Relevant standards

IEC The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
60598-2-22 Ed. 3.0: Luminaires - Part 2-22

Particular requirements - Luminaires for emergency lighting IEC 60364-5-56 Ed. 2.0: Low-voltage electrical installations - Part 5-56

Selection and erection of electrical equipment - Safety services International Organization for Standardization, ISO 30061:2007 (CIE S 020/E:2007): Emergency lighting (specifies the luminous requirements for emergency lighting systems)


Types

For UK and Australian regulations, two types are distinguished: * Maintained luminaires are permanently illuminated, and remain illuminated when power fails. They are used for tasks such as emergency exit lighting. In some cases they may be switched off deliberately, but are usually required to be active when a building is occupied, or when the public are admitted, such as for a theatre. * Sustained or non-maintained luminaires may be switched on and off normally. If the power fails, they turn on automatically.


See also

*
Lightstick A glow stick, also known as a light stick, chem light, light wand, light rod, and rave light, is a self-contained, short-term light-source. It consists of a translucent plastic tube containing isolated substances that, when combined, make light ...
* Exit sign


References


External links


ICEL
Industry Committee for Emergency Lighting (UK)
NEMA Emergency Lighting Section
National Electrical Manufacturers Association (US)
How to locate emergency lighting - a guide
(UK)
Planning and Placement - An Emergency Lighting Guide
(UK) {{DEFAULTSORT:Emergency Light Lighting Safety equipment