Emergency core cooling system
   HOME

TheInfoList



OR:

The three primary objectives of nuclear reactor safety systems as defined by the U.S.
Nuclear Regulatory Commission The United States Nuclear Regulatory Commission (NRC) is an independent agency of the United States government tasked with protecting public health and safety related to nuclear energy. Established by the Energy Reorganization Act of 1974, the ...
are to shut down the reactor, maintain it in a shutdown condition and prevent the release of radioactive material.


Reactor protection system (RPS)

A
reactor protection system A reactor protection system (RPS) is a set of nuclear safety and security components in a nuclear power plant designed to safely shut down the reactor and prevent the release of radioactive materials. The system can "trip" automatically (initiat ...
is designed to immediately terminate the nuclear reaction. By breaking the nuclear chain reaction, the source of heat is eliminated. Other systems can then be used to remove
decay heat Decay heat is the heat released as a result of radioactive decay. This heat is produced as an effect of radiation on materials: the energy of the alpha particle, alpha, Beta particle, beta or gamma radiation is converted into the thermal movement ...
from the core. All nuclear plants have some form of reactor protection system.


Control rods

Control rods are a series of rods that can be quickly inserted into the reactor core to absorb neutrons and rapidly terminate the nuclear reaction. They are typically composed of actinides,
lanthanides The lanthanide () or lanthanoid () series of chemical elements comprises at least the 14 Metal, metallic chemical elements with atomic numbers 57–70, from lanthanum through ytterbium. In the periodic table, they fill the 4f orbitals. Lutetium ...
,
transition metals In chemistry, a transition metal (or transition element) is a chemical element in the d-block of the periodic table (groups 3 to 12), though the elements of group 12 (and less often group 3) are sometimes excluded. The lanthanide and actinid ...
, and
boron Boron is a chemical element; it has symbol B and atomic number 5. In its crystalline form it is a brittle, dark, lustrous metalloid; in its amorphous form it is a brown powder. As the lightest element of the boron group it has three ...
, in various alloys with structural backing such as steel. In addition to being neutron absorbent, the alloys used also are required to have at least a low coefficient of thermal expansion so that they do not jam under high temperatures, and they have to be self-lubricating metal on metal, because at the temperatures experienced by nuclear reactor cores oil lubrication would foul too quickly.


Safety injection / standby liquid control

Boiling water reactors are able to SCRAM the reactor completely with the help of their control rods. In the case of a loss of coolant accident (LOCA), the water-loss of the primary cooling system can be compensated with normal water pumped into the cooling circuit. On the other hand, the standby liquid control (SLC) system (SLCS) consists of a solution containing
boric acid Boric acid, more specifically orthoboric acid, is a compound of boron, oxygen, and hydrogen with formula . It may also be called hydrogen orthoborate, trihydroxidoboron or boracic acid. It is usually encountered as colorless crystals or a white ...
, which acts as a neutron poison and rapidly floods the core in case of problems with the stopping of the chain reaction. Pressurized water reactors also can SCRAM the reactor completely with the help of their control rods. PWRs also use boric acid to make fine adjustments to reactor power level, or reactivity, using their Chemical and Volume Control System (CVCS). In the case of LOCA, PWRs have three sources of backup cooling water, high pressure injection (HPI), low pressure injection (LPI), and core flood tanks (CFTs). They all use water with a high concentration of boron.


Essential service water system

The essential service water system (ESWS) circulates the water that cools the plant's heat exchangers and other components before dissipating the heat into the environment. Because this includes cooling the systems that remove
decay heat Decay heat is the heat released as a result of radioactive decay. This heat is produced as an effect of radiation on materials: the energy of the alpha particle, alpha, Beta particle, beta or gamma radiation is converted into the thermal movement ...
from both the primary system and the spent
fuel rod Nuclear fuel refers to any substance, typically fissile material, which is used by nuclear power stations or other nuclear devices to generate energy. Oxide fuel For fission reactors, the fuel (typically based on uranium) is usually based o ...
cooling ponds, the ESWS is a safety-critical system.Pre-construction safety report - Sub-chapter 9.2 – Water Systems
AREVA NP / EDF, published 2009-06-29, accessed 2011-03-23
Since the water is frequently drawn from an adjacent river, the sea, or other large body of water, the system can be fouled by seaweed, marine organisms, oil pollution, ice and debris. In locations without a large body of water in which to dissipate the heat, water is recirculated via a
cooling tower A cooling tower is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream, to a lower temperature. Cooling towers may either use the evaporation of water to remove heat and cool the ...
. The failure of half of the ESWS pumps was one of the factors that endangered safety in the 1999 Blayais Nuclear Power Plant flood,Generic Results and Conclusions of Re-evaluating the Flooding in French and German Nuclear Power Plants
J. M. Mattéi, E. Vial, V. Rebour, H. Liemersdorf, M. Türschmann, ''Eurosafe Forum 2001'', published 2001, accessed 2011-03-21
The great lesson France has to learn from Fukushima
Deciphering Fukushima, published 2011-03-08, accessed 2012-05-08
while a total loss occurred during the Fukushima I and Fukushima II nuclear accidents in 2011.


Emergency core cooling systems

Emergency core cooling systems (ECCS) are designed to safely shut down a nuclear reactor during accident conditions. The ECCS allows the plant to respond to a variety of accident conditions (e.g. LOCAs) and additionally introduce redundancy so that the plant can be shut down even with one or more subsystem failures. In most plants, ECCS is composed of the following systems:


High pressure coolant injection system

The High Pressure Coolant Injection (HPCI) System consists of a pump or pumps that have sufficient pressure to inject coolant into the reactor vessel while it is pressurized. It is designed to monitor the level of coolant in the reactor vessel and automatically inject coolant when the level drops below a threshold. This system is normally the first line of defense for a reactor since it can be used while the reactor vessel is still highly pressurized.


Automatic depressurization system

The Automatic Depressurization System (ADS) consists of a series of valves which open to vent steam several feet under the surface of a large pool of liquid water (known as the wetwell or torus) in pressure suppression type containments (typically used in boiling water reactor designs), or directly into the primary containment structure in other types of containments, such as large-dry or ice-condenser containments (typically used in pressurized water reactor designs). The actuation of these valves depressurizes the reactor vessel and allows lower pressure coolant injection systems to function, which have very large capacities in comparison to the high pressure systems. Some depressurization systems are automatic in function, while others may require operators to manually activate them. In pressurized water reactors with large dry or ice condenser containments, the valves of the system are called ''Pilot-operated relief valves''.


Low pressure coolant injection system

An LPCI is an emergency system which consists of a pump that injects a coolant into the reactor vessel once it has been depressurized. In some nuclear power plants an LPCI is a mode of operation of a residual heat removal system, also known as an RHR or RHS but is generally called LPCI. It is also not a stand-alone valve or system.


Core spray system (only in BWRs)

This system uses spargers (pipes fitted with an array of many small spray nozzles) within the reactor pressure vessel to spray water directly onto the fuel rods, suppressing the generation of steam. Reactor designs can include core spray in high-pressure and low-pressure modes.


Containment spray system

This system consists of a series of pumps and spargers that spray coolant into the upper portion of the primary containment structure. It is designed to condense the steam into liquid within the primary containment structure in order to prevent overpressure and overtemperature, which could lead to leakage, followed by involuntary depressurization.


Isolation cooling system

This system is often driven by a steam turbine to provide enough water to safely cool the reactor if the reactor building is isolated from the control and turbine buildings. Steam turbine driven cooling pumps with pneumatic controls can run at mechanically controlled adjustable speeds, without battery power, emergency generator, or off-site electrical power. The Isolation cooling system is a defensive system against a condition known as station blackout. This system is not part of the ECCS and does not have a low coolant accident function. For pressurized water reactors, this system acts in the secondary cooling circuit and is called ''Turbine driven auxiliary feedwater system''.


Emergency electrical systems

Under normal conditions, nuclear power plants receive power from generator. However, during an accident a plant may lose access to this power supply and thus may be required to generate its own power to supply its emergency systems. These electrical systems usually consist of diesel generators and batteries.


Diesel generators

Diesel generators are employed to power the site during emergency situations. They are usually sized such that a single one can provide all the required power for a facility to shut down during an emergency. Facilities have multiple generators for redundancy. Additionally, systems that are required to shut down the reactor have separate electrical sources (often separate generators) so that they do not affect shutdown capability.


Motor generator flywheels

Loss of electrical power can occur suddenly and can damage or undermine equipment. To prevent damage, motor-generators can be tied to flywheels that can provide uninterrupted electrical power to equipment for a brief period. Often they are used to provide electrical power until the plant electrical supply can be switched to the batteries and/or diesel generators.


Batteries

Batteries often form the final redundant backup electrical system and are also capable of providing sufficient electrical power to shut down a plant.


Containment systems

Containment systems are designed to prevent the release of radioactive material into the environment.


Fuel cladding

The fuel cladding is the first layer of protection around the nuclear fuel and is designed to protect the fuel from corrosion that would spread fuel material throughout the reactor coolant circuit. In most reactors it takes the form of a sealed metallic or ceramic layer. It also serves to trap fission products, especially those that are gaseous at the reactor's
operating temperature An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the de ...
, such as
krypton Krypton (from 'the hidden one') is a chemical element; it has symbol (chemistry), symbol Kr and atomic number 36. It is a colorless, odorless noble gas that occurs in trace element, trace amounts in the Earth's atmosphere, atmosphere and is of ...
,
xenon Xenon is a chemical element; it has symbol Xe and atomic number 54. It is a dense, colorless, odorless noble gas found in Earth's atmosphere in trace amounts. Although generally unreactive, it can undergo a few chemical reactions such as the ...
and
iodine Iodine is a chemical element; it has symbol I and atomic number 53. The heaviest of the stable halogens, it exists at standard conditions as a semi-lustrous, non-metallic solid that melts to form a deep violet liquid at , and boils to a vi ...
. Cladding does not constitute shielding, and must be developed such that it absorbs as little radiation as possible. For this reason, materials such as magnesium and zirconium are used for their low
neutron capture Neutron capture is a nuclear reaction in which an atomic nucleus and one or more neutrons collide and merge to form a heavier nucleus. Since neutrons have no electric charge, they can enter a nucleus more easily than positively charged protons, wh ...
cross sections.


Reactor vessel

The reactor vessel is the first layer of shielding around the nuclear fuel and usually is designed to trap most of the radiation released during a nuclear reaction. The reactor vessel is also designed to withstand high pressures.


Primary containment

The primary containment system usually consists of a large metal and/or concrete structure (often cylindrical or bulb shaped) that contains the reactor vessel. In most reactors it also contains the radioactively contaminated systems. The primary containment system is designed to withstand strong internal pressures resulting from a leak or intentional depressurization of the reactor vessel.


Secondary containment

Some plants have a secondary containment system that encompasses the primary system. This is very common in BWRs because most of the steam systems, including the turbine, contain radioactive materials.


Core catching

In case of a full melt-down, the fuel would most likely end up on the concrete floor of the primary containment building. Concrete can withstand a great deal of heat, so the thick flat concrete floor in the primary containment will often be sufficient protection against the so-called China Syndrome. The Chernobyl plant didn't have a containment building, but the core was eventually stopped by the concrete foundation. Due to concerns that the core would melt its way through the concrete, a " core catching device" was invented, and a mine was quickly dug under the plant with the intention to install such a device. The device contains a quantity of metal designed to melt, diluting the corium and increasing its heat conductivity; the diluted metallic mass could then be cooled by water circulating in the floor. Today, all new Russian-designed reactors are equipped with core-catchers in the bottom of the containment building. The AREVA EPR, SNR-300, SWR1000, ESBWR, and Atmea I reactors have core catchers. The ABWR has a thick layer of
basaltic Basalt (; ) is an aphanitic (fine-grained) extrusive igneous rock formed from the rapid cooling of low-viscosity lava rich in magnesium and iron ( mafic lava) exposed at or very near the surface of a rocky planet or moon. More than 90% ...
concrete floor specifically designed to catch the core.


Standby gas treatment

A standby gas treatment system (SGTS) is part of the secondary containment system. The SGTS system filters and pumps air from secondary containment to the environment and maintains a negative pressure within the secondary containment to limit the release of radioactive material. Each SGTS train generally consists of a mist eliminator/roughing filter; an electric heater; a prefilter; two absolute ( HEPA) filters; an
activated charcoal "Activated" is a song by English singer Cher Lloyd. It was released on 22 July 2016 through Vixen Records. The song was made available to stream exclusively on ''Rolling Stone'' a day before to release (on 21 July 2016). Background In an inter ...
filter; an exhaust fan; and associated valves, ductwork, dampers, instrumentation and controls. The signals that trip the SGTS system are plant-specific; however, automatic trips are generally associated with the electric heaters and a high temperature condition in the charcoal filters.


Ventilation and radiation protection

In case of a radioactive release, most plants have a system designed to remove radioactivity from the air to reduce the effects of the radioactivity release on the employees and public. This system usually consists of containment ventilation that removes radioactivity and steam from primary containment. Control room ventilation ensures that plant operators are protected. This system often consists of
activated charcoal "Activated" is a song by English singer Cher Lloyd. It was released on 22 July 2016 through Vixen Records. The song was made available to stream exclusively on ''Rolling Stone'' a day before to release (on 21 July 2016). Background In an inter ...
filters that remove radioactive isotopes from the air.


See also

* Boiling water reactor safety systems * Nuclear accidents in the United States * Nuclear safety in the U.S. *
Passive nuclear safety Passive nuclear safety is a design approach for safety features, implemented in a nuclear reactor, that does not require any active intervention on the part of the operator or electrical/electronic feedback in order to bring the reactor to a saf ...
* World Association of Nuclear Operators


References


Standards

* American National Standard, ANSI N18.2, "Nuclear Safety Criteria for the Design of Stationary Pressurized Water Reactor Plants," August 1973. * IEEE 279, "Criteria for Protection Systems for Nuclear Power Generating Stations." {{DEFAULTSORT:Nuclear Safety Systems Nuclear reactor safety *Systems Nuclear power plant components