Classical interference microscopy, also called quantitative interference microscopy, uses two separate light beams with much greater lateral separation than that used in
phase contrast microscopy __NOTOC__ Phase-contrast microscopy (PCM) is an optical microscopy technique that converts phase shifts in light passing through a transparent specimen to brightness changes in the image. Phase shifts themselves are invisible, but become visible ...
or in differential interference microscopy (DIC). In variants of the interference microscope where object and reference beam pass through the same objective, two images are produced of every object (one being the "ghost image"). The two images are separated either laterally within the visual field or at different focal planes, as determined by the optical principles employed. These two images can be a nuisance when they overlap, since they can severely affect the accuracy of mass thickness measurements. Rotation of the preparation may thus be necessary, as in the case of DIC. One of the first usable interference microscopes was designed by Dyson and manufactured by Cooke, Troughton & Simms (later Vickers Instruments), York England. This ingenious optical system achieved interference imaging without requiring polarizing elements in the beam path. A later popular design involving polarizing elements was designed by Smith and marketed first by C. Baker, London, and subsequently by the American Optical Company in the US. The double-image problem commonly encountered with all the above-mentioned designs was completely avoided in the
Mach–Zehnder interferometer The Mach–Zehnder interferometer is a device used to determine the relative phase shift variations between two collimated beams derived by splitting light from a single source. The interferometer has been used, among other things, to measure p ...
design implemented by Horn, a most expensive instrument, not employing polarized light, but requiring precisely-matched duplicated objectives and condensers. With this design (marketed by E. Leitz) 60 mm beam separation was achieved in microscopy but here the new difficulty has arisen of balancing optical thicknesses of two separate
microscope slide A microscope slide is a thin flat piece of glass, typically 75 by 26 mm (3 by 1 inches) and about 1 mm thick, used to hold objects for examination under a microscope. Typically the object is mounted (secured) on the slide, and then b ...
preparations (sample and dummy) and maintaining this critical balance during longer observations (e.g.
time-lapse Time-lapse photography is a technique in which the frequency at which film frames are captured (the frame rate) is much lower than the frequency used to view the sequence. When played at normal speed, time appears to be moving faster and thus ...
studies of living cells maintained at 37 °C), otherwise a gradual change in background interference colour occurs over time. The main advantage offered by interference microscopy measurements is the possibility of measuring the projected dry mass of living cells, which was first effectively exploited by Andrew Huxley in studies of striated muscle cell structure and function, leading to the sliding filament model of muscle contraction. The popularity of interference microscopy peaked around 1940–1970s and fell after that because of the complexity of the instrument and difficulties in both its use and in the interpretation of image data. In recent years, the classical interference microscope (in particular the Mach–Zehnder instrument) has been "rediscovered" by biologists because its main original disadvantage (difficult interpretation of translated interference bands or complex coloured images) can now be easily surmounted by means of digital camera image recording, followed by the application of computer algorithms that rapidly deliver the processed data as false-colour images of projected dry mass. Interference microscopy for industrial inspection, semiconductor inspection and surface structure analysis is highly developed and in widespread use.{{cite journal , last1 = de Groot , first1 = P , year = 2015 , title = Principles of interference microscopy for the measurement of surface topography , journal = Advances in Optics and Photonics , volume = 7 , pages = 1–65 , doi = 10.1364/AOP.7.000001


Instrumentation history and makers' names

* Smith system (C. Baker, London, England) * Dyson (Cooke Troughton & Simms, York, England) * Jamin-Lebedeff (E. Leitz, Wetzlar, & Zeiss, Germany) * Mach–Zehnder (E. Leitz, Wetzlar, Germany)


References