Category 6 cable (Cat 6) is a standardized
twisted pair Twisted pair cabling is a type of wiring used for communications in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted b ...
cable for
Ethernet Ethernet () is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 1 ...
and other network
physical layer In the seven-layer OSI model of computer networking, the physical layer or layer 1 is the first and lowest layer; The layer most closely associated with the physical connection between devices. This layer may be implemented by a PHY chip. The ...
s that is backward compatible with the Category 5/5e and
Category 3 cable Category 3 cable, commonly known as or station wire, and less commonly known as VG or voice-grade (as, for example, in 100BaseVG), is an unshielded twisted pair (UTP) cable used in telephone wiring. It is part of a family of standards defin ...
standards. Cat 6 must meet more stringent specifications for
crosstalk In electronics, crosstalk is any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channel. Crosstalk is usually caused by undesired capacitive, i ...
and system noise than Cat 5 and Cat 5e. The cable standard specifies performance of up to 250 MHz, compared to 100 MHz for Cat 5 and Cat 5e. Whereas Category 6 cable has a reduced maximum length of when used for
10GBASE-T 10 Gigabit Ethernet (10GE, 10GbE, or 10 GigE) is a group of computer networking technologies for transmitting Ethernet frames at a rate of 10  gigabits per second. It was first defined by the IEEE 802.3ae-2002 standard. Unlike previous ...
, Category 6A cable is characterized to 500 MHz and has improved
alien crosstalk In electronics, crosstalk is any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channel. Crosstalk is usually caused by undesired capacitive, in ...
characteristics, allowing 10GBASE-T to be run for the same maximum distance as previous Ethernet variants.


History

Cat 6, an unshielded twisted-pair (UTP) design, emerged as an advancement of the UTP Cat 5e, and was formalised in 2001. The design of Cat 6 required more stringent precision in manufacturing, and this enabled reduced noise and crosstalk, allowing improved performance. The Telecommunications Industry Association (TIA) published Cat 6 in June 2002.


Description

Cat 6 cable can be identified by the printing on the side of the cable sheath. Cable types, connector types and cabling topologies are defined by
ANSI/TIA-568 ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is ''Commercial Building Telecommunications Cabling Standard'' and is published by the Telecommunications ...
. Cat 6 patch cables are normally terminated in
8P8C A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets. Modular connectors were originally developed fo ...
modular connectors, using either T568A or T568B pin assignments; performance is comparable provided both ends of a cable are terminated identically. If Cat 6-rated patch cables, jacks and connectors are not used with Cat 6 wiring, overall performance is degraded and may not meet Cat 6 performance specifications. The Cat 6 specification requires conductors to be pure copper. The industry has seen a rise in non-compliant or counterfeit cables, especially of the
copper-clad aluminium wire Copper-clad aluminium wire (CCAW or CCA) is a dual metal electrical conductor composed of an inner aluminium core and outer copper cladding. Uses The primary applications of this conductor revolve around weight reduction requirements. These a ...
(CCA) variety. This has exposed the manufacturers or installers of such fake cable to legal liabilities.


Category 6A

The standard for Category 6A (augmented Category 6) is ANSI/TIA-568.2-D (replaces 568-C.2), defined by TIA for enhanced performance standards for twisted pair cable systems. It was defined in 2018. Cat 6A performance is defined for frequencies up to 500 MHz—twice that of Cat 6. Cat 6A also has an improved alien crosstalk specification as compared to Cat 6, which picks up high levels of alien noise at high frequencies. The global cabling standard ISO/IEC 11801 has been extended by the addition of amendment 2. This amendment defines new specifications for Cat 6A components and Class EA permanent links. These new global Cat 6A/Class EA specifications require a new generation of connecting hardware offering far superior performance compared to the existing products that are based on the American TIA standard. The most important point is a performance difference between ISO/IEC and EIA/TIA component specifications for the NEXT transmission parameter. At a frequency of 500 MHz, an ISO/IEC Cat 6A connector performs 3 dB better than a Cat 6A connector that conforms with the EIA/TIA specification (3 dB equals 50% reduction of near-end crosstalk noise signal power; see
half-power point The half-power point is the point at which the output power has dropped to half of its peak value; that is, at a level of approximately -3  dB. In filters, optical filters, and electronic amplifiers, the half-power point is also known as hal ...
). Confusion therefore arises because of the naming conventions and performance benchmarks laid down by the International ISO/IEC and American TIA/EIA standards, which in turn are different from the regional European standard, EN 50173-1. In broad terms, the ISO standard for Cat 6A is the most stringent, followed by the European standard, and then the American (1 on 1 matching capability).


Category 6e and beyond

After the ratification of Cat 6, manufacturers began offering cables labeled as . The intent was to market ''Cat 6e'' as a pseudo official upgrade to the Category 6 standard naming it after the Category 5e standard. Officially Cat 6e is not a recognized ISO standard. Category 7 is an ISO standard, but not a TIA standard; it is a shielded cable with newer connectors (
GG45 GG45 (GigaGate 45) and ARJ45 (Augmented RJ45) are two related connectors for Category 7, Category 7A, and Category 8 telecommunication cabling. The GG45 interface and related implementations are developed and sold by Nexans S.A., while the ...
or
TERA TERA is a shielded twisted pair connector for use with Category 7 twisted-pair data cables, developed by The Siemon Company and standardised in 2003 by the International Electrotechnical Commission (IEC) with the reference IEC 61076-3-104. Th ...
) that are not backward-compatible with category 3 through 6A. Category 8 is the next network cabling offering to be backward compatible.


Maximum length

When used for
10/100/1000 Ethernet over twisted-pair technologies use twisted-pair cables for the physical layer of an Ethernet computer network. They are a subset of all Ethernet physical layers. Early Ethernet used various grades of coaxial cable, but in 1984, StarL ...
BASE-T, the maximum allowed length of a Cat 6 cable is . This consists of of solid ''horizontal'' cabling between the patch panel and the wall jack, plus of stranded patch cable between each jack and the attached device. For
10GBASE-T 10 Gigabit Ethernet (10GE, 10GbE, or 10 GigE) is a group of computer networking technologies for transmitting Ethernet frames at a rate of 10  gigabits per second. It was first defined by the IEEE 802.3ae-2002 standard. Unlike previous ...
, an unshielded Cat 6 cable should not exceed 55 meters and a Cat 6A cable should not exceed 100 meters.


Installation requirements

Category 6 and 6A cable must be properly installed and terminated to meet specifications. The cable must not be kinked or bent too tightly; the bend radius should be larger than four times the outer diameter of the cable. The wire pairs must not be untwisted and the outer jacket must not be stripped back more than . Cable shielding may be required in order to avoid data corruption in high
electromagnetic interference Electromagnetic interference (EMI), also called radio-frequency interference (RFI) when in the radio frequency spectrum, is a disturbance generated by an external source that affects an electrical circuit by electromagnetic induction, electrost ...
(EMI) environments. Shielding is typically maintained from one cable end to the other using a drain wire that runs through the cable alongside the twisted pairs. The shield's electrical connection to the chassis on each end is made through the jacks. The requirement for ground connections at both cable ends creates the possibility of creating a ground loop. This undesirable situation may compel currents to flow in the network cable shield and these currents may in turn induce detrimental noise in the signal being carried by the cable.


References


External links

* Information on cable construction and alien crosstalk mitigation. * Information on TIA TSB-155 37m versus
IEEE The Institute of Electrical and Electronics Engineers (IEEE) is a 501(c)(3) professional association for electronic engineering and electrical engineering (and associated disciplines) with its corporate office in New York City and its operati ...
55m limitations. * {{DEFAULTSORT:Category 6 Cable Ethernet cables