HOME

TheInfoList



OR:

This information sets out some of the basic considerations taken into account by the lifting
design engineer A design engineer is an engineer focused on the engineering design process in any of the various engineering disciplines (including civil, mechanical, electrical, chemical, textiles, aerospace, nuclear, manufacturing, systems, and structural ...
.


Compliance

Statements like those in AS3850, "Because of the mode in which failure can occur, it may be necessary to test complete systems and not calculate values obtained from a group of components that make up the system. The mode of failure of an individual component does not necessarily reflect the mode of failure of the system." But the standard does not continue to further the understanding required regarding test methods, the components that should be deemed as part of the system, the various modes of failure, and the interpretation of test results for each
failure mode Failure causes are defects in design, process, quality, or part application, which are the underlying cause of a failure or which initiate a process which leads to failure. Where failure depends on the user of the product or process, then human e ...
. And further in AS3850, "The strength limit state capacity shall be determined by a
statistical analysis Statistical inference is the process of using data analysis to infer properties of an underlying distribution of probability.Upton, G., Cook, I. (2008) ''Oxford Dictionary of Statistics'', OUP. . Inferential statistical analysis infers propertie ...
from the test results in accordance with Paragraph A4.5." and assuming the
test data Test data is data which has been specifically identified for use in tests, typically of a computer program. Background Some data may be used in a confirmatory way, typically to verify that a given set of input to a given function produces some e ...
is taken from a statistically valid
test method A test method is a method for a test in science or engineering, such as a physical test, chemical test, or statistical test. It is a definitive procedure that produces a test result. In order to ensure accurate and relevant test results, a test m ...
, the data is to be determined via statistical means to derive the Load resistance model, for the anchor. There are adequate load case
coefficient In mathematics, a coefficient is a multiplicative factor in some term of a polynomial, a series, or an expression; it is usually a number, but may be any expression (including variables such as , and ). When the coefficients are themselves ...
s available to estimate sling angle load amplification, suction from the casting bed, and various dynamic transportation load estimates.
Load resistance The input impedance of an electrical network is the measure of the opposition to current ( impedance), both static ( resistance) and dynamic ( reactance), into the load network that is ''external'' to the electrical source. The input admittance (the ...
factors of safety, FOS, set out in the Australian Code would typically denote a FOS of 5.0 for re-usable lifting equipment and an FOS of 2.5 for a lifting anchors. File:1_figure_1.jpg, Fig 1: Load resistance elements of an anchor system in a wall panel File:1_figure_2.jpg, Fig 2: Lifting system model for a thin section wall panel The
rigging Rigging comprises the system of ropes, cables and chains, which support a sailing ship or sail boat's masts—''standing rigging'', including shrouds and stays—and which adjust the position of the vessel's sails and spars to which they ar ...
arrangements can influence the applied anchor load, where statically indeterminate systems are not necessarily a design consideration, but can be used in practice. The determination of the loads through the rigging system must be a consideration whilst calculating the load resistant model, refer to the examples shown in Figure 3.


Basic principles

Even though years of experience accounts for a good gauge for the appropriate lifting anchor to be used, it should not be left to the reinforcement fabricators and precast factory personnel to select the lifting anchor. The design engineer should specifically account for the applied loads expected during the lifting, transport and placement (or re-usability requirements) of the element. Flexure, casting bed suction, load direction (axial 'tensile', angular 'sling', transverse 'shear') are also load considerations to be accounted for in the lifting design of the element. The anchor selection, together with additional reinforcement, and rigging arrangements is influenced by: - The dead weight of the element - The number of anchors in the element and the configuration of the anchor - Capacity of the anchor at the specific concrete
compressive strength In mechanics, compressive strength or compression strength is the capacity of a material or structure to withstand loads tending to reduce size (as opposed to tensile strength which withstands loads tending to elongate). In other words, compres ...
s at time of lift - The dynamic loads applied during lifting (suction to the casting bed, or crane dynamics) - The rigging configuration All of the above factors must be taken into consideration during the lifting design phase of the element. The weight of the element can be determined by the calculated volume, and using the
specific gravity Relative density, or specific gravity, is the ratio of the density (mass of a unit volume) of a substance to the density of a given reference material. Specific gravity for liquids is nearly always measured with respect to water at its dens ...
(normal weight reinforced concrete is approximately 24 kN/m3). Establishing the lifting anchor positions will influence the rigging arrangements used and therefore the static analysis of the rigging should be determined. Particular rigging configurations may be more suitable for particular job sites or lifting in place considerations, and the lifting design should denote the assumptions accordingly. For example, the statically determined systems, shown in Figure 3, where the determination of the loads is not always possible. File:1_figure_3.jpg, Fig 3: Rigging configurations determining load sharing per anchor Dynamic loads considered in lifting design are accounted for in two stages; suction to the casting bed on the initial lift and then the dynamic loads induced from crane vibration. These crane impact loads must be accounted for during transportation in the yard and on-site, and the coefficient increases from an overhead
gantry crane A gantry crane is a crane built atop a gantry, which is a structure used to straddle an object or workspace. They can range from enormous "full" gantry cranes, capable of lifting some of the heaviest loads in the world, to small shop cranes, us ...
through to a crane moving over rough terrain. Consideration for the entire transportation loads must be taken into account during the lifting design. Anchor capacity, or load resistance, should be considered for tensile loads (axial), sling angle (angular) and shear loads (transverse). Consideration of different load combinations may result in wide variations required from the lifting insert. The load directions during production, transport and placement should be considered carefully. Depending on the planned load direction, either a different anchor may be included in the lifting design, alternatively, reinforcement may be included to reduce the possibility of element flexure crack damage. The configuration (size, position and quantity) of this reinforcement should be supplemented to the element reinforcement design to ensure for adequate capacity of the lifting design. Lifting design is influenced by the
steel Steel is an alloy made up of iron with added carbon to improve its strength and fracture resistance compared to other forms of iron. Many other elements may be present or added. Stainless steels that are corrosion- and oxidation-resistan ...
/
concrete Concrete is a composite material composed of fine and coarse aggregate bonded together with a fluid cement (cement paste) that hardens (cures) over time. Concrete is the second-most-used substance in the world after water, and is the most wid ...
interaction of the specific anchor selected. Different load cases are considered by the lifting design engineer, such as anchor susceptibility to edge distance, placement sensitivity, and anchor capacity at the specific concrete strength at time of lift. For example, a footed pin head style anchor maybe more susceptible to edge distance than a hairpin style anchor. Or a splayed anchor does not have the same tensile/axial capacity with the equivalent anchor length (effective embedment is greater on a footed anchor than a splayed anchor of equivalent overall length, see figure 4). File:1_figure_4.jpg, Fig 4: These 2 anchors may have the same overall length, but very different Effective Embedment Depths, hef File:1_figure_5.jpg, Fig 5: These 2 anchors have different concrete load interactions, where the footed anchor is more susceptible to side blow-out in thin wall sections


Examples

Practical application must consider that the Load Resistance ≥ Applied Load File:1_table_1.jpg, Table 1: Casting bed suction coefficients File:1_table_2.jpg, Table 2: Lifting equipment dynamic coefficients File:1_table_3.jpg, Table 3: Rigging equipment sling angle coefficients Applied load To determine the required anchor, the
manufacturing plant A factory, manufacturing plant or a production plant is an Industry (manufacturing), industrial facility, often a complex consisting of several buildings filled with Outline of industrial machinery, machinery, where workers manufacturing, manuf ...
handling and the site handling should be considered separately. Example: A thin walled rectangular section, 6.0 m long, 3.0 m wide and 150 mm thick is being considered to be edge lifted from a horizontal steel bed using an overhead gantry crane, and then lifted on-site using a tower crane. No panel rotation is being considered. *Panel **Volume: V = w x h x d = 6.0 m x 3.0 m x 0.15 m = 2.7 m3 **Weight: W = V x concrete specific gravity = 2.7 m3 x 24 kN/m3 = 64.8 kN *Calculated casting bed suction **Suction area: A = w x h = 6.0 m x 3.0 m = 18 m2 **Assuming 1.0 kN/m2 is applied for oiled steel formwork **Suction force: S = A x 1.0 kN/m2 = 18 x 1.0 = 18 kN *Applied loads at element lifting (sling angle and lateral tension) **F = W x Ksl x Ks x 0.5 = 64.8 x 1.16 x 1.2 x 0.5 = 45.1 kN *Anchor capacity for initial lift **F/n = 23 kN per anchor during initial lift (n = 2 lifting anchors) *Transport loads in the yard and on-site **Suction due to casting bed adhesion is not considered, as the calculation takes into account the lifting device dynamic coefficient. **S = (W x Ksl x Kd) / n = (64.8 x 1.16 x 1.2) / 2 = 45.1 kN load resistance required per anchor *Anchor capacity for site lift **F/n = 23 kN per anchor during site lifting (n = 2 lifting anchors) **Reference to the load capacity tables provided by the anchor manufacturer is required to make an anchor selection for the specific concrete strengths at the time of lifting. Hence the great of the two calculated anchor capacities required at the concrete strength of the initial lift is normally selected.


Anchor interactions

When selecting an anchor, consider the element
formwork Formwork is molds into which concrete or similar materials are either precast or cast-in-place. In the context of concrete construction, the falsework supports the shuttering molds. In specialty applications formwork may be permanently i ...
and the ease of placement and securing of the anchor prior and during the pouring of the concrete. For example, some of the anchors shown in figures 4-6, can be placed into thin wall elements as the anchor chair maintains the position relative to the element thickness. As the orientation of the void determines the lift position of the
lifting clutch Lifting may refer to: *Manual handling of loads *Raising objects upwards, for example with lifting equipment *Weightlifting, lifting of weights for various ends **Olympic weightlifting, an Olympic sport that tests explosive strength **Powerlifting, ...
, the wire chair can be secured against the element reinforcement to maintain this orientation during the concrete pour and set. When an anchors load resistance must consider load reduction factors, this would imply that the particular selected anchor will form a different failure crack zone. For example, the anchors depicted in figure 5, a footed anchor has the tendency to overload the concrete cover in thin wall panels, hence is more susceptible to side blow-out failure than a hairpin style anchor, depicted in figure 8. File:1_figure_6.jpg, Fig 6: Typical Tilt-up facelift systems – thin wall panels or thin section elements required to be face lifted File:1_figure_7.jpg, Figure 7: Typical general element systems – facelift anchors normally placed in general precast elements File:1_figure_8.jpg, Figure 8: Typical edgelift systems – used for the majority of wall panel edgelifting


Conclusion

Lifting design if done correctly will consider many aspects which should be considered through the transportation load cycle of the concrete element. The considerations should cover the lifting system model and load resistance model. Using suitably qualified and experienced
engineer Engineers, as practitioners of engineering, are professionals who Invention, invent, design, analyze, build and test machines, complex systems, structures, gadgets and materials to fulfill functional objectives and requirements while considerin ...
s is certainly recommended as the consequences of getting the lifting design incorrect can be fatal. Efficiencies can be gained from getting the lifting design correct, by optimizing the number of anchors, correct reinforcement detail of the element, the correct selection of the anchor type and the minimizing the complexities of the rigging configurations.


References

* Prestressed Concrete Institute (PCI). PCI design handbook. 6th edition Chicago (IL): Precast/Prestressed Concrete Institute; 2004. * Australian Standards 3600 (AS). Concrete Structures (AS3600-2009), Sydney Australia, Standards Australia; 2009 * Australian Standards 3850 (AS). Tilt-up concrete construction (AS3850-2003), Sydney Australia, Standards Australia; 2003 {{DEFAULTSORT:Precast Concrete Lifting Anchor Systems - Lifting Considerations Concrete