telecommunication Telecommunication is the transmission of information by various types of technologies over wire, radio, optical, or other electromagnetic systems. It has its origin in the desire of humans for communication over a distance greater than that ...
, the term outside plant has the following meanings: *In civilian
telecommunications Telecommunication is the transmission of information by various types of technologies over wire, radio, optical, or other electromagnetic systems. It has its origin in the desire of humans for communication over a distance greater than that ...
, outside plant refers to all of the physical cabling and supporting infrastructure (such as conduit, cabinets, tower or poles), and any associated hardware (such as
repeater In telecommunications, a repeater is an electronic device that receives a signal and retransmits it. Repeaters are used to extend transmissions so that the signal can cover longer distances or be received on the other side of an obstruction. Some ...
s) located between a demarcation point in a switching facility and a demarcation point in another
switching center telephone exchange, telephone switch, or central office is a telecommunications system used in the public switched telephone network (PSTN) or in large enterprises. It interconnects telephone subscriber lines or virtual circuits of digital syste ...
or customer premises. *In the United States, the DOD defines outside plant as the communications equipment located between a main distribution frame (MDF) and a user
end instrument In the context of telecommunications, a terminal is a device which ends a telecommunications link and is the point at which a signal enters or leaves a network. Examples of terminal equipment include telephones, fax machines, computer termina ...
. The CATV industry divides its
fixed asset A fixed asset, also known as long-lived assets or property, plant and equipment (PP&E), is a term used in accounting for assets and property that may not easily be converted into cash. Fixed assets are different from current assets, such as cas ...
s between head end or inside plant, and outside plant. The electrical power industry also uses the term outside plant to refer to
electric power distribution Electric power distribution is the final stage in the delivery of electric power; it carries electricity from the transmission system to individual consumers. Distribution substations connect to the transmission system and lower the transmissi ...
systems.


Context

Network connections between devices such as computers, printers, and phones require a physical infrastructure to carry and process signals. Typically, this infrastructure will consist of: * Cables from wall outlets and jacks run to a communications closets, sometimes referred to as station cable. * Cables connecting one communications closet to another, sometimes referred to as riser cable. * Racks containing telecommunications hardware, such as
switches In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type ...
, routers, and
repeater In telecommunications, a repeater is an electronic device that receives a signal and retransmits it. Repeaters are used to extend transmissions so that the signal can cover longer distances or be received on the other side of an obstruction. Some ...
s. * Cables connecting one building to another. * Exterior communications cabinets containing hardware outside of buildings. * Radio transceivers used inside or outside buildings, such as
wireless access point In computer networking, a wireless access point (WAP), or more generally just access point (AP), is a networking hardware device that allows other Wi-Fi devices to connect to a wired network. As a standalone device, the AP may have a wired c ...
s, and hardware associated with them, such as antennas and towers. The portion of this infrastructure contained within a building is the inside plant, and the portion of this infrastructure connecting buildings or facilities is the outside plant. Where these two plants meet in a given structure is the demarcation point. Outside plant cabling, whether copper or fiber, is generally installed as aerial cable between poles, in an underground conduit system, or by direct burial. Hardware associated with the outside plant must be either protected from the elements (for example,
distribution frame Distribution may refer to: Mathematics *Distribution (mathematics), generalized functions used to formulate solutions of partial differential equations *Probability distribution, the probability of a particular value or value range of a varia ...
s are generally protected by a street side cabinet) or constructed with materials suitable for exposure to the elements. Installation of the outside plant elements often require construction of significant physical infrastructure, such as underground vaults. In older large installations, cabling is sometimes protected by air pressure systems designed to prevent water infiltration. While this is not a modern approach, the cost of replacement of the older cabling with sealed cabling is often prohibitively expensive. The cabling used in the outside plant must also be protected from electrical disturbances caused by lightning or voltage surges due to electrical shorts or induction.


Example: copper access network

In civilian telecommunications, the copper
access network An access network is a type of telecommunications network which connects subscribers to their immediate service provider. It is contrasted with the core network, which connects local providers to one another. The access network may be furthe ...
(also known as the
local loop In telephony, the local loop (also referred to as the local tail, subscriber line, or in the aggregate as the last mile) is the physical link or circuit that connects from the demarcation point of the customer premises to the edge of the com ...
) providing basic telephone or
DSL Digital subscriber line (DSL; originally digital subscriber loop) is a family of technologies that are used to transmit digital data over telephone lines. In telecommunications marketing, the term DSL is widely understood to mean asymmetric dig ...
services typically consists of the following elements: *In-house wiring that connects
customer premises equipment In telecommunications, a customer-premises equipment or customer-provided equipment (CPE) is any terminal and associated equipment located at a subscriber's premises and connected with a carrier's telecommunication circuit at the demarcation p ...
to the demarcation point, usually in residential installations contained in a weather protected box. *One or more
twisted pair Twisted pair cabling is a type of wiring used for communications in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted bal ...
s, called a drop wire. The drop wires typically connect to a splice case, located in line for aerial cables, or in a small weather protected case for underground wiring, where the local cabling is connected to a secondary feeder line. These cables contain fifty or more twisted pairs. *Secondary feeder lines run to a streetside cabinet containing a
distribution frame Distribution may refer to: Mathematics *Distribution (mathematics), generalized functions used to formulate solutions of partial differential equations *Probability distribution, the probability of a particular value or value range of a varia ...
called a
Serving Area Interface The serving area interface or service area interface (SAI) is an outdoor enclosure or metal box that allows access to telecommunications wiring. Alternate names *Access point (AP) *Cabinet (cab) *B-box (breakout box) *Cross box *Cross-connect b ...
(SAI). *The SAI is connected to the main distribution frame, located at a
Telephone exchange telephone exchange, telephone switch, or central office is a telecommunications system used in the public switched telephone network (PSTN) or in large enterprises. It interconnects telephone subscriber lines or virtual circuits of digital syst ...
or other switching facility, by one or more primary feeder lines which contain hundreds of copper twisted pairs. An SAI may also contain a Digital subscriber line access multiplexer (DSLAM) supporting
DSL Digital subscriber line (DSL; originally digital subscriber loop) is a family of technologies that are used to transmit digital data over telephone lines. In telecommunications marketing, the term DSL is widely understood to mean asymmetric dig ...
service. Active equipment (such as a POTS or
DSL Digital subscriber line (DSL; originally digital subscriber loop) is a family of technologies that are used to transmit digital data over telephone lines. In telecommunications marketing, the term DSL is widely understood to mean asymmetric dig ...
line circuit) can then be connected to the line in order to provide service, but this is not considered part of outside plant.


Protecting equipment in the outside plant

The environment can play a large role in the quality and lifespan of equipment used in the outside plant. It is critical that environmental testing criteria as well as design and performance requirements be defined for this type of equipment. There are generally four operating environments or classes covering all outside plant (OSP) applications, including wireless facilities. :*Class 1: Equipment in a Controlled Environment :*Class 2: Protected Equipment in Outside Environments :*Class 3: Protected Equipment in Severe Outside Environments :*Class 4: Products in an Unprotected Environment Electronic equipment located in one or more of these environmental class locations is designed to withstand various environmental operating conditions resulting from climatic conditions that may include rain, snow, sleet, high winds, ice, salt spray, and sand storms. Since outside temperatures can possibly range from −40 °C (−40 °F) to 46 °C (115 °F), with varying degrees of solar loading, along with humidity levels ranging from below 10% up to 100%, significant environmental stresses within the enclosure or facility can be produced. Telcordi
GR-3108, Generic Requirements for Network Equipment in the Outside Plant (OSP)
contains the most recent industry data regarding each Class described above. It also discusses what is currently happening in ATIS and Underwriters Laboratories (UL). The document also includes :*Environmental criteria such as operating temperatures, humidity, particulate contamination, pollution exposure, and heat dissipation :*Mechanical criteria such as structural requirements, packaging, susceptibility to vibration, earthquake, and handling :*Electrical protection and safety including protection from lightning surges, AC power induction and faults, and Electromagnetic Interference (EMI), and DC power influences


Handholes and other below-ground splice vaults

Handholes and other below-ground splice vaults house telecommunications components used in an Outside Plant (OSP) environment. Handholes are plastic or polymer concrete structures set below ground with their lids flush to the surrounding soil, turf, footpath, or road surface. They can be used to house and protect copper, coaxial, and optical fiber telephone cable splices and distribution elements. They safeguard and provide convenient access to cable termination and branch points, provide flexibility and access for installation operations (e.g., pulling or blowing cables), provide mechanical and environmental protection for splices, allow access for craftsperson work activities, and discourage access by unauthorized persons. Handholes and other below-ground splice vaults are deployed in a variety of environments. The major distinctions in these environments focus on the strength and frequency of vehicular and foot traffic loading. There are four basic application environments: :*Light Duty: Pedestrian Only :*Medium Duty: Pedestrian and Light Incidental Vehicular Traffic (Up to Class 5 Vehicles) :*Heavy Duty: Non-Deliberate (Incidental) Vehicular Traffic (Up to Class 7 Vehicles) :*Heavy Duty: Non-Deliberate (Incidental) Vehicular Traffic (Up to Class 8 Vehicles) Handhole-type products deployed in any environment are subjected to the following types of traffic loading: Vertical Cover Load, Vertical Sidewall Load, Lateral Sidewall Load, and Long-Term Lateral Sidewall Load. Telcordi
GR-902, ''Generic Requirements for Handholes and Other Below-Ground Splice Vaults,''
contains detailed industry requirements for handholes, and includes specific loading requirements for the defined application environments. It provides explicit correlations to other standards such as ANSI/SCTE-77,ANSI/SCTE-77, ''Specification for Underground Enclosure Integrity'' AASHTOAmerican Association of State Highway and Transportation Officials (AASHTO) specifications, and ASTM C857.American Society for Testing and Materials (ASTM) C857, ''Standard Practice for Minimum Structural Design Loading for Underground Precast Concrete Utility Structures''


Corrosion resistance

Corrosion in outside plant telecommunications network components is caused by exposure to the effects of temperature, humidity, electrical power, and contaminants. Corrosion resistance criteria for these network components are based on the environments to which they are exposed. Outside plant environments can be above-ground, underground, buried, or underwater. Industry requirements document
Telcordia iconectiv is a supplier of network planning and network management services to telecommunications providers. Known as Bellcore after its establishment in the United States in 1983 as part of the break-up of the Bell System, the company's name ...
br>GR-2836
defines these environments and provides corrosion resistance criteria for the telecommunications equipment in each.GR-2836-CORE, ''Generic Requirements for Assuring Corrosion Resistance of Telecommunication Equipment in the Outside Plant,''
Telcordia.
It also includes references to various associated
ASTM ASTM International, formerly known as American Society for Testing and Materials, is an international standards organization that develops and publishes voluntary consensus technical standards for a wide range of materials, products, systems, an ...
Standards.


Above-ground plant

Above-ground plant includes all the telecommunications equipment physically located on or above the ground. This includes enclosures such as huts, cabinets, and pedestals, and the equipment mounted therein. It also includes pole-mounted equipment and cases, and pole-line hardware. Above-ground plant can be exposed to extreme temperatures, and to humidity that varies with the seasons and with daily temperature changes. When humidity condenses on the surfaces of outdoor apparatus or equipment, the corrosivity of the moisture layer can be increased by industrial pollutants that render the condensate moisture corrosive. In sea coastal areas, wind-borne, salt-laden water droplets can deposit on exposed components. Near large cultivated areas, where fertilizers are applied by airplanes, the wind may carry nitrates, phosphates, and ammonium compounds to settle on metallic components of the above-ground telephone plant. Similarly, in residential areas, lawn fertilizers and herbicides can cause corrosion. In regions with snow, the salts used to melt snow and ice on roadways can accelerate corrosion. Under extreme conditions, pedestals and cabinets may be flooded with water that contains mud and corrosive salts. Corrosion of these flooded components may be accelerated by the presence of dc voltages used to power the networks. Secretions from insects can also accelerate corrosion. Finally, chewing by rodents may expose metallic components, normally protected by a polymer or paint coating, to a corrosive environment.


Underground plant

Underground plant includes all the telecommunications equipment installed in underground structures such as utility holes, Controlled Environment Vaults (CEVs), and ducts, along with associated hardware. Underground plant can be exposed to waters containing water-soluble salts of the native soil. Utility holes often show evidence of corrosion of support hardware and bonding ribbons that is caused by sulfate-reducing bacteria. The environment in utility holes and ducts can be made corrosive by man-made chemicals such as industrial effluent, fertilizers, and de-icing salts. Protective plastic coatings and cable jackets can rapidly deteriorate from leaking steam pipes present in many urban areas and from gasoline leaking from underground storage tanks. The most aggressive contributor to corrosion of underground plant is dc stray current from electrified rail transportation systems, cathodic protection rectifiers, or welding and mining operations. Although such dc currents are mostly dealt with “after the fact” using protective systems (e.g., low resistance bonds, reverse current switches, cathodic protection), some of the protection has to be included at the manufacturing stage. This protection may include insulating covers on cable shields, or nonmetallic components or coatings for apparatus.


Buried plant

Buried plant consists of telecommunications equipment such as cables, splice closures, lower parts of pedestals, and grounding systems directly buried in the soil. Buried plant can be exposed to the same corrosive environment as underground plant. In addition, attack by gophers can expose underlying components to corrosion attack.


Underwater plant

Underwater plant includes all telecommunications equipment located beneath the surface of a body of water. This includes cables and repeaters. The water can range from relatively pure, to brackish, to badly contaminated with industrial effluent.