HOME

TheInfoList



OR:

Myocardial perfusion imaging or scanning (also referred to as MPI or MPS) is a
nuclear medicine Nuclear medicine or nucleology is a medical specialty involving the application of radioactive substances in the diagnosis and treatment of disease. Nuclear imaging, in a sense, is "radiology done inside out" because it records radiation emitting ...
procedure that illustrates the function of the heart muscle (
myocardium Cardiac muscle (also called heart muscle, myocardium, cardiomyocytes and cardiac myocytes) is one of three types of vertebrate muscle tissues, with the other two being skeletal muscle and smooth muscle. It is an involuntary, striated muscle tha ...
). It evaluates many heart conditions, such as coronary artery disease (CAD),
hypertrophic cardiomyopathy Hypertrophic cardiomyopathy (HCM, or HOCM when obstructive) is a condition in which the heart becomes thickened without an obvious cause. The parts of the heart most commonly affected are the interventricular septum and the ventricles. This r ...
and heart wall motion abnormalities. It can also detect regions of myocardial infarction by showing areas of decreased resting perfusion. The function of the myocardium is also evaluated by calculating the left ventricular
ejection fraction An ejection fraction (EF) is the volumetric fraction (or portion of the total) of fluid (usually blood) ejected from a chamber (usually the heart) with each contraction (or heartbeat). It can refer to the cardiac atrium, ventricle, gall bladder, ...
(LVEF) of the heart. This scan is done in conjunction with a
cardiac stress test A cardiac stress test (also referred to as a cardiac diagnostic test, cardiopulmonary exercise test, or abbreviated CPX test) is a cardiological test that measures the heart's ability to respond to external stress in a controlled clinical enviro ...
. The diagnostic information is generated by provoking controlled regional ischemia in the heart with variable
perfusion Perfusion is the passage of fluid through the circulatory system or lymphatic system to an organ or a tissue, usually referring to the delivery of blood to a capillary bed in tissue. Perfusion is measured as the rate at which blood is deliver ...
. Planar techniques, such as conventional scintigraphy, are rarely used. Rather,
single-photon emission computed tomography Single-photon emission computed tomography (SPECT, or less commonly, SPET) is a nuclear medicine tomographic imaging technique using gamma rays. It is very similar to conventional nuclear medicine planar imaging using a gamma camera (that is, ...
(SPECT) is more common in the US. With multihead SPECT systems, imaging can often be completed in less than 10 minutes. With SPECT, inferior and posterior abnormalities and small areas of infarction can be identified, as well as the occluded blood vessels and the mass of
infarcted Infarction is tissue death (necrosis) due to inadequate blood supply to the affected area. It may be caused by artery blockages, rupture, mechanical compression, or vasoconstriction. The resulting lesion is referred to as an infarct (from the ...
and viable myocardium.Merck manuals > Radionuclide Imaging
Last full review/revision May 2009 by Michael J. Shea, MD. Content last modified May 2009
The usual isotopes for such studies are either
Thallium-201 Thallium (81Tl) has 41 isotopes with atomic masses that range from 176 to 216. 203Tl and 205Tl are the only stable isotopes and 204Tl is the most stable radioisotope with a half-life of 3.78 years. 207Tl, with a half-life of 4.77 minutes, has the ...
or
Technetium-99m Technetium-99m (99mTc) is a metastable nuclear isomer of technetium-99 (itself an isotope of technetium), symbolized as 99mTc, that is used in tens of millions of medical diagnostic procedures annually, making it the most commonly used Radiopharm ...
.


History

The history of nuclear cardiology began in 1927 when Dr. Herrmann Blumgart developed the first method for measuring cardiac strength by injecting subjects with a radioactive compound known as Radium C ( 214Bi). The substance was injected into the venous system and travelled through the right heart into the lungs, then into the left heart and out into the arterial system where it was then detected through a Wilson chamber. The Wilson chamber represented a primitive scintillation counter which could measure radioactivity. Measured over time, this sequential acquisition of radioactivity produced what was known as "circulation time". The longer the "circulation time", the weaker the heart. Blumgart's emphasis was twofold. First, radioactive substances could be used to determine cardiac physiology (function) and should be done so with the least amount of radioactivity necessary to do so. Secondly, to accomplish this task, one needs to obtain multiple counts over time. For decades no substantial work was done, until 1959. Dr.
Richard Gorlin Richard Gorlin (June 30, 1926 – October 16, 1997) was an American cardiologist known for his contributions to the fields of valvular heart disease, coronary artery disease and cardiac catheterization, digitalis and vasodilators in congestive he ...
's work on "resting" studies of the heart and nitroglycerin emphasized several points. First, like Blumgart, he emphasized that evaluation of cardiac function required multiple measurements of change over time and these measurements must be performed under same state conditions, without changing the function of the heart in between measurements. If one is to evaluate ischemia (reductions in coronary blood flow resulting from coronary artery disease) then individuals must be studied under "stress" conditions and comparisons require "stress-stress" comparisons. Similarly, if tissue damage (heart attack, myocardial infarction, cardiac stunning or hibernation) is to be determined, this is done under "resting" conditions. Rest-stress comparisons do not yield adequate determination of either ischemia or infarction. By 1963, Dr. William Bruce, aware of the tendency of people with coronary artery disease to experience angina (cardiac chest discomfort) during exercise, developed the first standardized method of "stressing" the heart, where serial measurements of changes in blood pressure, heart rate and electrocardiographic (ECG/EKG) changes could be measured under "stress-stress" conditions. By 1965 Dr. William Love demonstrated that the cumbersome cloud chamber could be replaced by a
Geiger counter A Geiger counter (also known as a Geiger–Müller counter) is an electronic instrument used for detecting and measuring ionizing radiation. It is widely used in applications such as radiation dosimetry, radiological protection, experimental p ...
, which was more practical to use. However, Love had expressed the same concern as many of his colleagues, namely that there were no suitable radioisotopes available for human use in the clinical setting.


Use of thallium-201

By the mid-1970s, scientists and clinicians alike began using
thallium-201 Thallium (81Tl) has 41 isotopes with atomic masses that range from 176 to 216. 203Tl and 205Tl are the only stable isotopes and 204Tl is the most stable radioisotope with a half-life of 3.78 years. 207Tl, with a half-life of 4.77 minutes, has the ...
as the radioisotope of choice for human studies. Individuals could be placed on a treadmill and be "stressed" by the "
Bruce protocol The Bruce protocol is a diagnostic test used in the evaluation of cardiac function, developed by Robert A. Bruce. It is a standardized multistage treadmill test for assessing cardiovascular health. Developed by Robert A. Bruce in 1963 who was an ...
" and when near peak performance, could be injected with thallium-201. The isotope required exercise for an additional minute to enhance circulation of the isotope. Using nuclear cameras of the day and given the limitations of Tl-201, the first "stress" image could not be taken until 1 hour after "stress". In keeping with the concept of comparison images, the second "stress" image was taken 4 hours after "stress" and compared with the first. The movement of Tl-201 reflected differences in tissue delivery (blood flow) and function (mitochondrial activity). The relatively long half-life of Tl-201 (73 hours) forced doctors to use relatively small () doses of Tl-201, albeit with relatively large dose exposure and tissue effects (20 mSv). The poor quality images resulted in the search for isotopes which would produce better results.


The introduction of technetium-99m isotopes

By the late 1980s, two different compounds containing technetium-99m were introduced: teboroxime and
sestamibi Technetium (99mTc) sestamibi (INN) (commonly sestamibi; USP: technetium Tc 99m sestamibi; trade name Cardiolite) is a pharmaceutical agent used in nuclear medicine imaging. The drug is a coordination complex consisting of the radioisotope techn ...
. The utilization of Tc-99m would allow higher doses (up to ) due to the shorter physical (6 hours) half life of Tc-99m. This would result in more decay, more scintillation and more information for the nuclear cameras to measure and turn into better pictures for the clinician to interpret.


Major indications

* Diagnosis of CAD and various cardiac abnormalities. * Identifying location and degree of CAD in patients with a history of CAD. * Prognosis of patients who are at risk of having a myocardial or coronary incident (i.e. myocardial infarction, myocardial ischemia,
coronary aneurysm Coronary artery aneurysm is an abnormal dilatation of part of the coronary artery. This rare disorder occurs in about 0.3–4.9% of patients who undergo coronary angiography. Signs and symptoms Causes Acquired causes include atherosclerosis in a ...
, wall motion abnormalities). * Assessment of viable myocardium in particular coronary artery territory following heart attacks to justify revascularization * Post intervention revascularization (
coronary artery bypass Coronary artery bypass surgery, also known as coronary artery bypass graft (CABG, pronounced "cabbage") is a surgical procedure to treat coronary artery disease (CAD), the buildup of plaques in the arteries of the heart. It can relieve chest pai ...
graft,
angioplasty Angioplasty, is also known as balloon angioplasty and percutaneous transluminal angioplasty (PTA), is a minimally invasive endovascular procedure used to widen narrowed or obstructed arteries or veins, typically to treat arterial atheroscleros ...
) evaluation of heart. * Evaluation of shortness of breath of a possible cardiac origin.


Radiation dose

From 1993 to 2001, myocardial perfusion scans in the US increased >6%/y with "no justification". Myocardial perfusion imaging scans are "powerful predictors of future clinical events", and in theory may identify patients for whom aggressive therapies should improve outcome. But this is "only a hypothesis, not a proof". However, several trials have indicated the high sensitivity (90%) of the test, regardless of tracer, outweighing any potential detrimental effect of the
ionising radiation Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can t ...
. In the UK, NICE guidance recommends myocardial perfusion scans following myocardial infarction or reperfusion interventions. The power of prognosis from a myocardial perfusion scan is excellent and has been well tested, and this is "perhaps the area of nuclear cardiology where the evidence is most strong". Many radionuclides used for myocardial perfusion imaging, including
rubidium-82 Rubidium-82 (82Rb) is a radioactive isotope of rubidium. 82Rb is widely used in myocardial perfusion imaging. This isotope undergoes rapid uptake by myocardiocytes, which makes it a valuable tool for identifying myocardial ischemia in Positron Em ...
,
technetium-99m Technetium-99m (99mTc) is a metastable nuclear isomer of technetium-99 (itself an isotope of technetium), symbolized as 99mTc, that is used in tens of millions of medical diagnostic procedures annually, making it the most commonly used Radiopharm ...
and
thallium-201 Thallium (81Tl) has 41 isotopes with atomic masses that range from 176 to 216. 203Tl and 205Tl are the only stable isotopes and 204Tl is the most stable radioisotope with a half-life of 3.78 years. 207Tl, with a half-life of 4.77 minutes, has the ...
have similar typical effective doses (15-35 mSv). The positron emission tomography (PET) tracer nitrogen-13 ammonia, though less widely available, may offer significantly reduced doses (2 mSv).A revised effective dose estimate for the PET perfusion tracer Rb-82, deKemp et al, J NUCL MED MEETING ABSTRACTS, 2008. 49(MeetingAbstracts_1): p. 183P-b-.Radiopharmaceuticals for nuclear cardiology: radiation dosimetry, uncertainties, and risk., Stabin et al, J Nucl Med, 2008. 49(9): p. 1555-63. Stress-only protocols may also prove to be effective at reducing costs and patient exposure.Stress-only Nuclear Myocardial Perfusion Imaging
Heston TF, Internet Med J, accessed 17-Feb-2012.


References

{{Authority control Cardiac imaging 3D nuclear medical imaging Scintigraphy Technetium-99m