HOME

TheInfoList



OR:

A goniometer is an instrument that either measures an angle or allows an object to be rotated to a precise angular position. The term goniometry derives from two Greek words, γωνία (''gōnía'') '
angle In Euclidean geometry, an angle is the figure formed by two rays, called the '' sides'' of the angle, sharing a common endpoint, called the ''vertex'' of the angle. Angles formed by two rays lie in the plane that contains the rays. Angles ...
' and μέτρον (''métron'') ' measure'. The first known description of a goniometer, based on the astrolabe, was by
Gemma Frisius Gemma Frisius (; born Jemme Reinerszoon; December 9, 1508 – May 25, 1555) was a Frisian physician, mathematician, cartographer, philosopher, and instrument maker. He created important globes, improved the mathematical instruments of his ...
in 1538.


Applications


Surveying

Prior to the invention of the
theodolite A theodolite () is a precision optical instrument for measuring angles between designated visible points in the horizontal and vertical planes. The traditional use has been for land surveying, but it is also used extensively for building and ...
, the goniometer was used in
surveying Surveying or land surveying is the technique, profession, art, and science of determining the terrestrial two-dimensional or three-dimensional positions of points and the distances and angles between them. A land surveying professional is ...
. The application of triangulation to
geodesy Geodesy ( ) is the Earth science of accurately measuring and understanding Earth's figure (geometric shape and size), orientation in space, and gravity. The field also incorporates studies of how these properties change over time and equival ...
was described in the second (1533) edition of ''Cosmograficus liber'' by Petri Appiani as a 16-page appendix by Frisius entitled ''Libellus de locorum describendorum ratione''.


Communications

The
Bellini–Tosi direction finder A Bellini–Tosi direction finder (B–T or BTDF) is a type of radio direction finder (RDF), which determines the direction to, or ''bearing'' of, a radio transmitter. Earlier RDF systems used very large rotating loop antennas, which the B–T sy ...
was a type of radio direction finder that was widely used from
World War I World War I (28 July 1914 11 November 1918), often abbreviated as WWI, was List of wars and anthropogenic disasters by death toll, one of the deadliest global conflicts in history. Belligerents included much of Europe, the Russian Empire, ...
to
World War II World War II or the Second World War, often abbreviated as WWII or WW2, was a world war that lasted from 1939 to 1945. It involved the World War II by country, vast majority of the world's countries—including all of the great power ...
. It used the signals from two crossed antennas, or four individual antennas simulating two crossed ones, to re-create the radio signal in a small area between two loops of wire. The operator could then measure the angle to the target radio source by performing direction finding within this small area. The advantage to the Bellini–Tosi system is that the antennas do not move, allowing them to be built at any required size. The basic technique remains in use, although the equipment has changed dramatically. Goniometers are widely used for military and civil purposes, e.g. interception of satellite and naval communications on the French warship Dupuy de Lôme uses multiple goniometers.


Crystallography

In crystallography, goniometers are used for measuring angles between crystal faces. They are also used in X-ray diffraction to rotate the samples. The groundbreaking investigations of physicist Max von Laue and colleagues into the atomic structure of crystals in 1912 involved a goniometer.


Light measurement

Goniophotometers measure the spatial distribution of light visible to the human eye (often luminous intensity) at specific angular positions, usually covering all spherical angles.


In medicine

A goniometer is used to document initial and subsequent range of motion, at the visits for occupational injuries, and by
disability Disability is the experience of any condition that makes it more difficult for a person to do certain activities or have equitable access within a given society. Disabilities may be cognitive, developmental, intellectual, mental, physical, ...
evaluators to determine a permanent disability. This is to evaluate progress, and also for medico-legal purposes. It is a tool to evaluate
Waddell's signs Waddell's signs are a group of physical signs, first described in a 1980 article in ''Spine'', and named for the article's principal author, Professor Gordon Waddell (1943–2017), a Scottish Orthopedic Surgeon. Waddell's signs may indicate no ...
(findings that may indicate symptom magnification.)


Rehabilitative therapy

In physical therapy, occupational therapy, and athletic training, a goniometer measures range of motion of limbs and joints of the body. These measurements help accurately track progress in a rehabilitation program. When a patient has decreased range of motion, a therapist assesses the joint before performing an intervention, and continues to use the tool to monitor progress. The therapist can take these range of motion measurements at any joint. They typically require knowledge about the anatomy of the body, particularly bony landmarks. For example, when measuring the knee joint, the therapist places the axis (point of rotation) on the lateral
epicondyle An epicondyle () is a rounded eminence on a bone that lies upon a condyle ('' epi-'', "upon" + ''condyle'', from a root meaning "knuckle" or "rounded articular area"). There are various epicondyles in the human skeleton, each named by its anatomic ...
of the femur, and lines up the stationary arm with the greater trochanter of the
femur The femur (; ), or thigh bone, is the proximal bone of the hindlimb in tetrapod vertebrates. The head of the femur articulates with the acetabulum in the pelvic bone forming the hip joint, while the distal part of the femur articulates ...
. Finally, the therapist lines up the moveable arm of the goniometer with the lateral malleolus of the
fibula The fibula or calf bone is a leg bone on the lateral side of the tibia, to which it is connected above and below. It is the smaller of the two bones and, in proportion to its length, the most slender of all the long bones. Its upper extremity ...
, and records a measurement using the degree scale on the circular portion of the tool. Reading
accuracy Accuracy and precision are two measures of '' observational error''. ''Accuracy'' is how close a given set of measurements ( observations or readings) are to their '' true value'', while ''precision'' is how close the measurements are to each o ...
is sometimes a problem with goniometers. Issues with the intra-measure (between measures) and inter-tester (between clinicians) reliability may increase as the experience of the examiner decreases. Some studies suggest that these errors can be anywhere between 5 and 10 degrees. These goniometers come in different forms that some argue increase reliability. The universal standard goniometer is a plastic or metal tool with 1 degree increments. The arms are usually not longer than 12-inches, so it can be hard to accurately pinpoint the exact landmark for measurement. The telescopic-armed goniometer is more reliable—with a plastic circular axis like a classic goniometer, but with arms that extend to as long as two feet in either direction. More recently in the twenty-first century,
smartphone A smartphone is a portable computer device that combines mobile telephone and computing functions into one unit. They are distinguished from feature phones by their stronger hardware capabilities and extensive mobile operating systems, whi ...
application developers have created mobile applications that provide the functions of a goniometer. These applications (such as Knee Goniometer and Goniometer Pro) use the accelerometers in phones to calculate joint angles. Recent research supports these applications and their devices as reliable and valid tools with as much accuracy as a universal goniometer. Modern rehabilitative therapy motion capture systems perform goniometry at the very least measuring active range of motion. While in some cases accuracy may be inferior to a goniometer, measuring angles with a motion capture system is superior at measuring during dynamic, as opposed to static situations. Furthermore, using a traditional goniometer takes valuable time. In the clinical context, performing manual measurements takes valuable time and may not be practical.


Surface science


Contact angle goniometer

In
surface science Surface science is the study of physical and chemical phenomena that occur at the interface of two phases, including solid– liquid interfaces, solid– gas interfaces, solid–vacuum interfaces, and liquid– gas interfaces. It includes th ...
, an instrument called a contact angle goniometer or
tensiometer Tensiometer may refer to one of a number of devices. The two most common are: *Tensiometer (surface tension) an instrument used to measure the surface tension of liquids *Tensiometer (soil science) A tensiometer in soil science is a measuri ...
measures the static contact angle, advancing and receding contact angles, and sometimes surface tension. The first contact angle goniometer was designed by William Zisman of the
United States Naval Research Laboratory The United States Naval Research Laboratory (NRL) is the corporate research laboratory for the United States Navy and the United States Marine Corps. It was founded in 1923 and conducts basic scientific research, applied research, technological ...
in Washington, D.C. and manufactured by ramé-hart (now ramé-hart instrument company), New Jersey, USA. The original manual contact angle goniometer used an eyepiece with a microscope. Today's contact angle goniometer uses a camera and software to capture and analyze the drop shape, and is better suited for dynamic and advanced studies.


Surface tension

Contact angle goniometers (q.v.)can also determine the
surface tension Surface tension is the tendency of liquid surfaces at rest to shrink into the minimum surface area possible. Surface tension is what allows objects with a higher density than water such as razor blades and insects (e.g. water striders) t ...
for any liquid in gas or the
interfacial tension Surface tension is the tendency of liquid surfaces at rest to shrink into the minimum surface area possible. Surface tension is what allows objects with a higher density than water such as razor blades and insects (e.g. water striders) t ...
between any two liquids. If the difference in densities between the two fluids is known, the surface tension or interfacial tension can be calculated by the pendant drop method. An advanced instrument often called a goniometer / tensiometer includes software tools that measure
surface tension Surface tension is the tendency of liquid surfaces at rest to shrink into the minimum surface area possible. Surface tension is what allows objects with a higher density than water such as razor blades and insects (e.g. water striders) t ...
and
interfacial tension Surface tension is the tendency of liquid surfaces at rest to shrink into the minimum surface area possible. Surface tension is what allows objects with a higher density than water such as razor blades and insects (e.g. water striders) t ...
using the pendant drop, inverted pendant drop, and sessile drop methods, in addition to contact angle. A
centrifugal adhesion balance Centrifugal (a key concept in rotating systems) may refer to: *Centrifugal casting (industrial), Centrifugal casting (silversmithing), and Spin casting (centrifugal rubber mold casting), forms of centrifigual casting *Centrifugal clutch *Centrifu ...
relates the contact angles to the adhesion of the drop to the surface. A gonioreflectometer measures the reflectivity of a surface at a number of angles.


Positioning

A positioning goniometer or goniometric stage is a device that rotates an object precisely about a fixed axis in space. It is similar to a linear stage— however, rather than move linearly relative to its base, the stage platform rotates partially about a fixed axis above the mounting surface of the platform. Positioning goniometers typically use a worm drive with a partial worm wheel fixed to the underside of the stage platform meshing with a worm in the base. The worm gear may be rotated manually, or by a motor in automated positioning systems.


Knife and blade cutting edge angle measurement

The included cutting angles of all kinds of sharp edge blades are measured using a laser reflecting goniometer. Developed by the
Cutlery and Allied Trades Research Association Cutlery and Allied Trades Research Association (CATRA) is an internationally known research and technology organisation in Sheffield, England which specialises in knives, cutlery, tableware, metallic holloware (such as pans), shaving razors, indus ...
(CATRA) in the UK, a range of devices can accurately determine the cutting edge profile, including a rounding of the tip to ½°. The included angle of a blade is important in controlling its cutting ability and edge strength—i.e., a low angle makes a thin sharp edge optimized for cutting softer materials, while a large angle makes a thick edge that is less sharp but stronger, which may be better for cutting harder materials.


Doctor blade inspection

Used doctor blades, from gravure and other
printing Printing is a process for mass reproducing text and images using a master form or template. The earliest non-paper products involving printing include cylinder seals and objects such as the Cyrus Cylinder and the Cylinders of Nabonidus. The ...
and
coating A coating is a covering that is applied to the surface of an object, usually referred to as the substrate. The purpose of applying the coating may be decorative, functional, or both. Coatings may be applied as liquids, gases or solids e.g. Pow ...
processes, can be inspected with a goniometer, typically with a built-in light source, to examine the blade edge for wear and correct angles. A difference in angle from that set on the machine may indicate excessive pressure, and a range of angles ("rounding") probably indicates a lack of stiffness, or wear, in the blade holder assembly.


See also

* * * *


References

{{Reflist


External links


Reference for the famous Chain Home British Radar of WWII
Angle measuring instruments Dimensional instruments Laboratory equipment Occupational therapy Physical therapy Surface science Surveying instruments