Electron spectroscopy refers to a group formed by techniques based on the analysis of the energies of emitted electrons such as photoelectrons and Auger electrons. This group includes
X-ray photoelectron spectroscopy X-ray photoelectron spectroscopy (XPS) is a surface-sensitive quantitative spectroscopic technique based on the photoelectric effect that can identify the elements that exist within a material (elemental composition) or are covering its surface, ...
(XPS), which also known as Electron Spectroscopy for Chemical Analysis (ESCA),
Electron energy loss spectroscopy In electron energy loss spectroscopy (EELS) a material is exposed to a beam of electrons with a known, narrow range of kinetic energies. Some of the electrons will undergo inelastic scattering, which means that they lose energy and have their pa ...
(EELS),
Ultraviolet photoelectron spectroscopy Ultraviolet photoelectron spectroscopy (UPS) refers to the measurement of kinetic energy spectra of photoelectrons emitted by molecules which have absorbed ultraviolet photons, in order to determine molecular orbital energies in the valence regio ...
(UPS), and
Auger electron spectroscopy A Hanford scientist uses an Auger electron spectrometer to determine the elemental composition of surfaces. Auger electron spectroscopy (AES; pronounced in French) is a common analytical technique used specifically in the study of surfaces and, ...
(AES). These analytical techniques are used to identify and determine the elements and their electronic structures from the surface of a test sample. Samples can be solids, gases or liquids.Yang Leng; ''Materials Characterization: Introduction to Microscopic and Spectroscopic Methods (Second Edition)''; Publisher John Wiley & Sons, Incorporated 2013; p: 191-192, 221-224.Daintith, J.; ''Dictionary of Chemistry (6th Edition)''; Oxford University Press, 2008; p: 191, 416, 541 Chemical information is obtained only from the uppermost atomic layers of the sample (depth 10 nm or less) because the energies of Auger electrons and photoelectrons are quite low, typically 20 - 2000 eV. For this reason, electron spectroscopy is a technique for surface chemical analyzes.


History

The development of electron spectroscopy can be considered to have begun in 1887 when the German physicist
Heinrich Rudolf Hertz Heinrich Rudolf Hertz ( ; ; 22 February 1857 – 1 January 1894) was a German physicist who first conclusively proved the existence of the electromagnetic waves predicted by James Clerk Maxwell's equations of electromagnetism. The unit o ...
discovered the
photoelectric effect The photoelectric effect is the emission of electrons when electromagnetic radiation, such as light, hits a material. Electrons emitted in this manner are called photoelectrons. The phenomenon is studied in condensed matter physics, and solid sta ...
but was unable to explain it. In 1900,
Max Planck Max Karl Ernst Ludwig Planck (, ; 23 April 1858 – 4 October 1947) was a German theoretical physicist whose discovery of energy quanta won him the Nobel Prize in Physics in 1918. Planck made many substantial contributions to theoretical ...
(1918 Nobel Prize in Physics) suggested that energy carried by electromagnetic waves could only be released in "packets" of energy. In 1905
Albert Einstein Albert Einstein ( ; ; 14 March 1879 – 18 April 1955) was a German-born theoretical physicist, widely acknowledged to be one of the greatest and most influential physicists of all time. Einstein is best known for developing the theory ...
(1921 Nobel Prize of Physics) explained Planck's discovery and the photoelectric effect. He presented the hypothesis that light energy is carried in discrete quantized packets (photons), each with energy hν to explain the experimental dobservations. Two years after this publication, in 1907, P. D. Innes recorded the first XPS spectrum.J. Theo Kloprogge, Barry J. Wood; ''Handbook of Mineral Spectroscopy: Volume 1: X-ray Photoelectron Spectra''; Elsevier 2020; p. xiii-xiv. After numerous developments and the Second World War, Kai Siegbahn (Nobel Prize in 1981) with his research group in Uppsala, Sweden registered in 1954 the first XPS device to produce a high energy-resolution XPS spectrum. In 1967, Siegbahn published a comprehensive study of XPS and its usefulness, which he called electron spectroscopy for chemical analysis (ESCA). Concurrently with Siegbahn's work, in 1962, David W. Turner at
Imperial College London Imperial College London (legally Imperial College of Science, Technology and Medicine) is a public research university in London, United Kingdom. Its history began with Prince Albert, consort of Queen Victoria, who developed his vision for a cu ...
(and later
Oxford University Oxford () is a city in England. It is the county town and only city of Oxfordshire. In 2020, its population was estimated at 151,584. It is north-west of London, south-east of Birmingham and north-east of Bristol. The city is home to the ...
) developed
ultraviolet photoelectron spectroscopy Ultraviolet photoelectron spectroscopy (UPS) refers to the measurement of kinetic energy spectra of photoelectrons emitted by molecules which have absorbed ultraviolet photons, in order to determine molecular orbital energies in the valence regio ...
(UPS) for molecular species using a helium lamp.


Basic theory

In electron spectroscopy, depending on the technique, irradiating the sample with high-energy particles such as X-ray photons, electron beam electrons, or ultraviolet radiation photons, causes Auger electrons and photoelectrons to be emitted. Figure 1 illustrates this on the basis of a single particle in which, for example, the incoming X-ray photon from a particular energy range (E=hν) transfers its energy to an electron in the inner shell of an atom. Photon absorption caused electron emission leaves a hole in the atomic shell (see figure 1 (a)). The hole can be filled in two ways, forming different characteristic rays that are specific to each element. As the electron in the shell of a higher energy level fills the hole, a fluorescent photon is emitted (figure 1 (b)). In the Auger phenomenon, the electron in the shell of the higher energy level fills the hole that causes the adjacent or nearby electron to emit, forming the Auger electron (figure 1 (c)). As can be seen from discussed above and figure 1, Auger electrons and photoelectrons are different in their physical origin, however, both types of electrons carry similar information about the chemical elements in material surfaces. Each element has its own special Auger electron or photon electron energy from which these can be identified. The binding energy of a photoelectron can be calculated by the formula below. : E_\text = h\nu - E_\text - \phi where ''Ebinding'' is the binding energy of the photoelectron, hν is the energy of the incoming radiation particle, ''Ekinetic'' is the kinetic energy of the photoelectron measured by the device and \phi is the
work function In solid-state physics, the work function (sometimes spelt workfunction) is the minimum thermodynamic work (i.e., energy) needed to remove an electron from a solid to a point in the vacuum immediately outside the solid surface. Here "immediately" m ...
. The kinetic energy of the Auger electron is approximately equal to the energy difference between the binding energies of the electron shells involved in the Auger process. This can be calculated as follows: : E_\text = h\nu - E_\text - E_\text where ''Ekinetic'' is the kinetic energy of the Auger electron, hν is the energy of the incoming radiation particle and ''EB'' is first outer shell binding energy and ''EC'' is second outer shell binding energies.


Types of electron spectroscopy

*
X-ray photoelectron spectroscopy X-ray photoelectron spectroscopy (XPS) is a surface-sensitive quantitative spectroscopic technique based on the photoelectric effect that can identify the elements that exist within a material (elemental composition) or are covering its surface, ...
*
Auger electron spectroscopy A Hanford scientist uses an Auger electron spectrometer to determine the elemental composition of surfaces. Auger electron spectroscopy (AES; pronounced in French) is a common analytical technique used specifically in the study of surfaces and, ...
*
Electron energy loss spectroscopy In electron energy loss spectroscopy (EELS) a material is exposed to a beam of electrons with a known, narrow range of kinetic energies. Some of the electrons will undergo inelastic scattering, which means that they lose energy and have their pa ...
*
Ultraviolet photoelectron spectroscopy Ultraviolet photoelectron spectroscopy (UPS) refers to the measurement of kinetic energy spectra of photoelectrons emitted by molecules which have absorbed ultraviolet photons, in order to determine molecular orbital energies in the valence regio ...


References

{{Reflist Spectroscopy