HOME

TheInfoList



OR:

In
architecture Architecture is the art and technique of designing and building, as distinguished from the skills associated with construction. It is both the process and the product of sketching, conceiving, planning, designing, and constructing buildings ...
, a daylight factor (DF) is the ratio of the light level inside a structure to the light level outside the structure. It is defined as:
:''DF = (Ei / Eo) x 100%'' where, ''Ei'' = illuminance due to
daylight Daylight is the combination of all direct and indirect sunlight during the daytime. This includes direct sunlight, diffuse sky radiation, and (often) both of these reflected by Earth and terrestrial objects, like landforms and buildings. Sunligh ...
at a point on the indoors working plane, ''Eo'' = simultaneous outdoor illuminance on a horizontal plane from an unobstructed hemisphere of overcast sky. To calculate ''Ei'', requires knowing the amount of outside light received inside of a building. Light can reach a room via through a glazed window, rooflight, or other aperture via three paths: * Direct light from a patch of sky visible at the point considered, known as the sky component (''SC''), * Light reflected from an exterior surface and then reaching the point considered, known as the externally reflected component (''ERC''), * Light entering through the window but reaching the point only after reflection from an internal surface, known as the internally reflected component (''IRC''). The sum of the three components gives the illuminance level (typically measured in
lux The lux (symbol: lx) is the unit of illuminance, or luminous flux per unit area, in the International System of Units (SI). It is equal to one lumen per square metre. In photometry, this is used as a measure of the intensity, as perceived by ...
) at the point considered:
:''Illuminance = SC + ERC + IRC'' The daylight factor can be improved by increasing SC (for example placing a window so it "sees" more of the sky rather than adjacent buildings), increasing ERC (for example by painting surrounding buildings white), increasing IRC (for example by using light colours for room surfaces). In most rooms, the ceiling and floor are a fixed colour, and much of the walls are covered by furnishings. This gives less flexibility in changing the daylight factor by using different wall colours than might be expected meaning changing SC is often the key to good daylight design. Architects and engineers use daylight factors in
architecture Architecture is the art and technique of designing and building, as distinguished from the skills associated with construction. It is both the process and the product of sketching, conceiving, planning, designing, and constructing buildings ...
and building design to assess the internal natural lighting levels as perceived on working planes or surfaces. They use this information to determine if light is sufficient for occupants to carry out normal activities. The design day for daylight factor calculations is based on the standard CIE overcast Sky for 21 September at 12:00pm, and where the ''Ground Ambient'' light level is 11921 Lux. CIE being the ''Commission Internationale de l´Eclairage'', or ''
International Commission on Illumination The International Commission on Illumination (usually abbreviated CIE for its French name, Commission internationale de l'éclairage) is the international authority on light, illumination, colour, and colour spaces. It was established in 1913 a ...
''. Calculating daylight factors requires complex repetition of calculations and thus is generally undertaken using a complex software product such as
Radiance In radiometry, radiance is the radiant flux emitted, reflected, transmitted or received by a given surface, per unit solid angle per unit projected area. Radiance is used to characterize diffuse emission and reflection of electromagnetic radiati ...
. This is a suite of tools for performing ''lighting simulation'', which includes a renderer as well as many other tools for measuring simulated light levels. It uses ray tracing to perform all lighting calculations. One failing in many of these calculations is that they are often completed without wall hangings or furniture against the walls. This can lead to higher predictions of the daylight factor than is correct. To assess the effect of a poor or good daylight factor, one might compare the results for a given calculation against published design guidance. In the UK this is likely to be
CIBSE The Chartered Institution of Building Services Engineers (CIBSE; pronounced 'sib-see') is an international professional engineering association based in London, England that represents building services engineers. It is a full member of the C ...
Lighting Guide 10 (LG10-1999), which broadly bands average daylight factors into the following categories:CIBSE Lighting Guide 10: Daylighting and window design, Year: 1999, , Publisher: CIBSE * Under 2 – Not adequately lit – artificial lighting is required all of the time * Over 5 – Well lit – artificial lighting generally not required, except at dawn and dusk – but glare and solar gain may cause problems


See also

*
Daylighting Daylighting is the practice of placing windows, skylights, other openings, and reflective surfaces so that sunlight (direct or indirect) can provide effective internal lighting. Particular attention is given to daylighting while designing a b ...
*
Right to light Right to light is a form of easement in English law that gives a long-standing owner of a building with windows a right to maintain an adequate level of illumination. The right was traditionally known as the doctrine of "ancient lights". It is ...