HOME

TheInfoList



OR:

A cryostat (from ''cryo'' meaning cold and ''stat'' meaning stable) is a device used to maintain low
cryogenic In physics, cryogenics is the production and behaviour of materials at very low temperatures. The 13th IIR International Congress of Refrigeration (held in Washington DC in 1971) endorsed a universal definition of “cryogenics” and “cr ...
temperatures of samples or devices mounted within the cryostat. Low temperatures may be maintained within a cryostat by using various refrigeration methods, most commonly using cryogenic fluid bath such as liquid helium. Hence it is usually assembled into a vessel, similar in construction to a
vacuum flask A vacuum flask (also known as a Dewar flask, Dewar bottle or thermos) is an insulating storage vessel that greatly lengthens the time over which its contents remain hotter or cooler than the flask's surroundings. Invented by Sir James Dew ...
or Dewar. Cryostats have numerous applications within science, engineering, and medicine.


Types


Closed-cycle cryostats

Closed-cycle cryostats consist of a chamber through which cold helium vapour is pumped. An external mechanical refrigerator extracts the warmer helium exhaust vapour, which is cooled and recycled. Closed-cycle cryostats consume a relatively large amount of electrical power, but need not be refilled with helium and can run continuously for an indefinite period. Objects may be cooled by attaching them to a metallic coldplate inside a vacuum chamber which is in thermal contact with the helium vapour chamber.


Continuous-flow cryostats

Continuous-flow cryostats are cooled by liquid cryogens (typically liquid helium or nitrogen) from a storage dewar. As the cryogen boils within the cryostat, it is continuously replenished by a steady flow from the storage dewar. Temperature control of the sample within the cryostat is typically performed by controlling the flow rate of cryogen into the cryostat together with a heating wire attached to a PID temperature control loop. The length of time over which cooling may be maintained is dictated by the volume of cryogens available. Owing to the scarcity of liquid helium, some laboratories have facilities to capture and recover helium as it escapes from the cryostat, although these facilities are also costly to operate.


Bath cryostats

Bath cryostats are similar in construction to
vacuum flask A vacuum flask (also known as a Dewar flask, Dewar bottle or thermos) is an insulating storage vessel that greatly lengthens the time over which its contents remain hotter or cooler than the flask's surroundings. Invented by Sir James Dew ...
s filled with liquid helium. A coldplate is placed in thermal contact with the liquid helium bath. The liquid helium may be replenished as it boils away, at intervals between a few hours and several months, depending on the volume and construction of the cryostat. The boil-off rate is minimised by shielding the bath with either cold helium vapour, or vacuum shield with walls constructed from super insulator material. The helium vapour which boils away from the bath very effectively cools thermal shields around the outside of the bath. In the older designs there may be additional liquid nitrogen bath, or several concentric layers of shielding, with gradually increasing temperatures. However, the invention of super insulator materials has made this technology obsolete.


Multistage cryostats

In order to achieve temperatures lower than liquid helium at atmospheric pressure, additional cooler stages may be added to the cryostat. Temperatures down to 1K can be reached by attaching the coldplate to a
1-K pot A 1-K pot (i.e. 1-kelvin pot) is a cryogenic device used to attain temperatures down to approximately 1 kelvin. The 1-K pot is a small vessel in a cryogenic system that is filled with liquid helium. Usually it is a few cubic centimeters in size w ...
, which is a container of the He-4 isotope that may be pumped to low vapor pressure via a vacuum pump. Temperatures just below 0.300K may be achieved using He-3, the rare isotope of helium, as the working fluid in a helium pot. Temperatures down to 1mK can be reached by employing
dilution refrigerator A 3He/4He dilution refrigerator is a cryogenic device that provides continuous cooling to temperatures as low as 2  mK, with no moving parts in the low-temperature region. The cooling power is provided by the heat of mixing of the He ...
or
dry dilution refrigerator A 3He/4He dilution refrigerator is a cryogenic device that provides continuous cooling to temperatures as low as 2  mK, with no moving parts in the low-temperature region. The cooling power is provided by the heat of mixing of the He ...
typically in addition to the main stage and 1K pot. Temperatures below that can be reached using magnetic refrigeration.


Applications


Magnetic resonance imaging and research magnet types

Cryostats used in
MRI Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to form pictures of the anatomy and the physiological processes of the body. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves ...
machines are designed to hold a
cryogen In physics, cryogenics is the production and behaviour of materials at very low temperatures. The 13th IIR International Congress of Refrigeration (held in Washington DC in 1971) endorsed a universal definition of “cryogenics” and “cr ...
, typically helium, in a liquid state with minimal evaporation (boil-off). The liquid helium bath is designed to keep the
superconducting magnet A superconducting magnet is an electromagnet made from coils of superconducting wire. They must be cooled to cryogenic temperatures during operation. In its superconducting state the wire has no electrical resistance and therefore can conduct much ...
's bobbin of
superconductive Superconductivity is a set of physical properties observed in certain materials where electrical resistance vanishes and magnetic flux fields are expelled from the material. Any material exhibiting these properties is a superconductor. Unlike ...
wire in its superconductive state. In this state, the wire has no electrical resistance and very large currents are maintained with low power input. To maintain superconductivity, the bobbin must be kept below its
transition temperature Transition temperature is the temperature at which a material changes from one crystal state ( allotrope) to another. More formally, it is the temperature at which two crystalline forms of a substance can co-exist in equilibrium. For example, whe ...
by being immersed in the liquid helium. If, for any reason, the wire becomes resistive, i.e. loses superconductivity, a condition known as a " quench", the liquid helium evaporates, instantly raising pressure within the vessel. A
burst disk A rupture disk, also known as a pressure safety disc, burst disc, bursting disc, or burst diaphragm, is a non-reclosing pressure relief safety device that, in most uses, protects a pressure vessel, equipment or system from overpressurization ...
, usually made of carbon, is placed within the chimney or vent pipe so that during a pressure excursion, the gaseous helium can be safely vented out of the MRI suite. Modern MRI cryostats use a mechanical refrigerator (
cryocooler A refrigerator designed to reach cryogenic temperatures (below ) is often called a cryocooler. The term is most often used for smaller systems, typically table-top size, with input powers less than about 20 kW. Some can have input powers as lo ...
) to re-condense the helium gas and return it to the bath, to maintain cryogenic conditions and to conserve helium. Typically cryostats are manufactured with two vessels, one inside the other. The outer vessel is evacuated with the vacuum acting as a thermal insulator. The inner vessel contains the cryogen and is supported within the outer vessel by structures made from low-conductivity materials. An intermediate shield between the outer and inner vessels intercepts the heat radiated from the outer vessel. This heat is removed by a cryocooler. Older helium cryostats used a
liquid nitrogen Liquid nitrogen—LN2—is nitrogen in a liquid state at low temperature. Liquid nitrogen has a boiling point of about . It is produced industrially by fractional distillation of liquid air. It is a colorless, low viscosity liquid that is wide ...
vessel as this radiation shield and had the liquid helium in an inner, third, vessel. Nowadays few units using multiple cryogens are made with the trend being towards 'cryogen-free' cryostats in which all heat loads are removed by cryocoolers.


Biological microtome type

Cryostats are used in medicine to cut histological slides. They are usually used in a process called frozen section histology (see
Frozen section procedure The frozen section procedure is a pathological laboratory procedure to perform rapid microscopic analysis of a specimen. It is used most often in oncological surgery. The technical name for this procedure is cryosection. The microtome device that ...
). The cryostat is essentially an ultrafine "deli-slicer", called a
microtome A microtome (from the Greek ''mikros'', meaning "small", and ''temnein'', meaning "to cut") is a cutting tool used to produce extremely thin slices of material known as ''sections''. Important in science, microtomes are used in microscopy, allow ...
, placed in a freezer. The cryostat is usually a stationary upright freezer, with an external wheel for rotating the microtome. The temperature can be varied, depending on the tissue being cut usually from minus 20 to minus 30 degree Celsius. The freezer is either powered by electricity, or by a refrigerant like liquid nitrogen. Small portable cryostats are available and can run off generators or vehicle inverters. To minimize unnecessary warming all necessary mechanical movements of the microtome can be achieved by hand via a wheel mounted outside the chamber. Newer microtomes have electric push button advancement of the tissue. The precision of the cutting is in micrometres. Tissue are sectioned as thin as 1 micrometre. Usual histology slides are mounted with a thickness of about 7 micrometres. Specimens that are soft at room temperature are mounted on a cutting medium (often made of egg white) on a metal "chuck", and frozen to cutting temperature (for example at -20 degrees C). Once frozen, the specimen on the chuck is mounted on the microtome. The crank is rotated and the specimen advances toward the cutting blade. Once the specimen is cut to a satisfactory quality, it is mounted on a warm (room temperature) clear glass slide, where it will instantaneously melt and adhere. The glass slide and specimen is dried with a dryer or air dried, and stained. The entire process from mounting to reading the slide takes from 10 to 20 minutes, allowing rapid diagnosis in the operating room, for the surgical excision of cancer. The cryostat can be used to cut histology and tissue slide (e.g., for enzyme localization) outside of medicine, but the quality of the section is poor compared to standard fixed section wax mounted histology. Newer technology such as the Compresstome, a type of vibrating microtome, utilizes agarose tissue embedding instead of an optimal cutting temperature compound to eliminate the need for traditional cryostat freezing and may be used for improved quality sectioning.{{Cite journal, last=Abdelaal, first=Hadia M., last2=Kim, first2=Hyeon O., last3=Wagstaff, first3=Reece, last4=Sawahata, first4=Ryoko, last5=Southern, first5=Peter J., last6=Skinner, first6=Pamela J., date=2015-01-01, title=Comparison of Vibratome and Compresstome sectioning of fresh primate lymphoid and genital tissues for in situ MHC-tetramer and immunofluorescence staining, journal=Biological Procedures Online, volume=17, issue=1, pages=2, doi=10.1186/s12575-014-0012-4, pmid=25657614, pmc=4318225, issn=1480-9222


See also

*
Lambda point refrigerator A lambda point refrigerator is a device used to cool liquid helium, typically around a superconducting magnet or for low temperature measurements, from approximately 4.2 K to temperatures near the lambda point of helium (approximately 2.17 K), the ...


References

Containers Cryogenics Vacuum flasks