HOME

TheInfoList



OR:

Cold filter plugging point (CFPP) is the lowest temperature, expressed in degrees Celsius (°C), at which a given volume of
diesel Diesel may refer to: * Diesel engine, an internal combustion engine where ignition is caused by compression * Diesel fuel, a liquid fuel used in diesel engines * Diesel locomotive, a railway locomotive in which the prime mover is a diesel engi ...
type of fuel still passes through a standardized filtration device in a specified time when cooled under certain conditions. This test gives an estimate for the lowest temperature that a fuel will give trouble free flow in certain fuel systems. This is important as in cold temperate countries, a high cold filter plugging point will clog up vehicle engines more easily. The test is important in relation to the use of additives that allow spreading the usage of
winter diesel Winter diesel fuel (also known as ''winter diesel'', alpine diesel, or winterised diesel) refers to diesel fuel enhanced to prevent it from gelling in cold weather conditions. In general it is achieved by treatment with additives that change the ...
at temperatures below the cloud point. The tests according to
EN 590 EN 590 is a standard published by the European Committee for Standardization that describes the physical properties that all automotive diesel fuel must meet if it is to be sold in the European Union and several other European countries. Based on ...
show that a CloudPoint of +1 °C can have a CFPP −10 °C. Current additives allow a CFPP of −20 °C to be based on diesel fuel with a CloudPoint of −7 °C. The trustworthiness of the EN 590 have been criticized as being too low for modern diesel motors – the German ADAC has run a test series on customary winter diesel in a cold chamber. All diesel brands did exceed the legal minimum by 3 to 11 degrees in the laboratory according to the legal DIN test. One of the real diesel motors however stopped working even before the legal minimum was reached, presumably due to an undersized filter heater. Notably the experiments did not show a direct correlation between the CFPP value of the mineral oil and the cold start capability of the diesel motors – hence the automobile club suggest the creation of a new test standard.


Test method

The ASTM no. for the test method to define cold filter plugging point is ASTM D-6371.


See also

*
Cloud point In liquids, the cloud point is the temperature below which a transparent solution undergoes either a liquid-liquid phase separation to form an emulsion or a liquid-solid phase transition to form either a stable sol or a suspension that settles a ...
*
Petroleum Petroleum, also known as crude oil, or simply oil, is a naturally occurring yellowish-black liquid mixture of mainly hydrocarbons, and is found in geological formations. The name ''petroleum'' covers both naturally occurring unprocessed crud ...
*
Pour point The pour point of a liquid is the temperature below which the liquid loses its flow characteristics. It is defined as the minimum temperature in which the oil has the ability to pour down from a beaker. In crude oil a high pour point is general ...


References


External links


BP information
{{physical-chemistry-stub Chemical properties Fuel technology