transmission windows (1310/1550 nm respectively) including the critical frequencies where OH scattering may occur. OH-free silica fibers are recommended if the wavelengths between second and third transmission windows are to be used. Avoiding this region, the channels 47, 49, 51, 53, 55, 57, 59, 61 remain and these are the most commonly used. With OS2 fibers the water peak problem is overcome, and all possible 18 channels can be used.
WDM, CWDM and DWDM are based on the same concept of using multiple wavelengths of light on a single fiber but differ in the spacing of the wavelengths, number of channels, and the ability to amplify the multiplexed signals in the optical space.
EDFA
An optical amplifier is a device that amplifies an optical signal directly, without the need to first convert it to an electrical signal. An optical amplifier may be thought of as a laser without an optical cavity, or one in which feedback fr ...
provide an efficient wideband amplification for the
C-band, Raman amplification adds a mechanism for amplification in the L-band. For CWDM, wideband optical amplification is not available, limiting the optical spans to several tens of kilometres.
Coarse WDM
Originally, the term ''coarse wavelength division multiplexing'' (CWDM) was fairly generic and described a number of different channel configurations. In general, the choice of channel spacings and frequency in these configurations precluded the use of
erbium doped fiber amplifiers (EDFAs). Prior to the relatively recent ITU standardization of the term, one common definition for CWDM was two or more signals multiplexed onto a single fiber, with one signal in the 1550 nm band and the other in the 1310 nm band.
In 2002, the ITU standardized a channel spacing grid for CWDM (ITU-T G.694.2) using the wavelengths from 1270 nm through 1610 nm with a channel spacing of 20 nm. ITU G.694.2 was revised in 2003 to shift the channel centers by 1 nm so, strictly speaking, the center wavelengths are 1271 to 1611 nm. Many CWDM wavelengths below 1470 nm are considered unusable on older
G.652
G.652 is an international standard that describes the geometrical, mechanical, and transmission attributes of a single-mode optical fibre and cable, developed by the Standardization Sector of the International Telecommunication Union (ITU-T) th ...
specification fibers, due to the increased attenuation in the 1270–1470 nm bands. Newer fibers which conform to the G.652.C and G.652.D standards, such as Corning SMF-28e and Samsung Widepass, nearly eliminate the "water peak" attenuation peak at 1383 nm and allow for full operation of all 18 ITU CWDM channels in metropolitan networks.
The main characteristic of the recent ITU CWDM standard is that the signals are not spaced appropriately for amplification by EDFAs. This limits the total CWDM optical span to somewhere near 60 km for a 2.5 Gbit/s signal, which is suitable for use in metropolitan applications. The relaxed optical frequency stabilization requirements allow the associated costs of CWDM to approach those of non-WDM optical components.
CWDM Applications
CWDM is being used in
cable television
Cable television is a system of delivering television programming to consumers via radio frequency (RF) signals transmitted through coaxial cables, or in more recent systems, light pulses through fibre-optic cables. This contrasts with broa ...
networks, where different wavelengths are used for the ''downstream'' and ''upstream'' signals. In these systems, the wavelengths used are often widely separated. For example, the downstream signal might be at 1310 nm while the upstream signal is at 1550 nm.
Some
GBIC
A gigabit interface converter (GBIC) is a standard for transceivers, first defined in 1995 and commonly used with Gigabit Ethernet and Fibre Channel for some time. By offering a standard, hot swappable electrical interface, a single gigabit por ...
and small form factor pluggable (
SFP
SFP may refer to:
Organizations
* Salton Inc. (former stock symbol: SFP), now part of Russell Hobbs, Inc.
* Swedish People's Party of Finland, a Swedish minority and mainly liberal party in Finland
* Syrian Free Press, a Syrian social news networ ...
) transceivers utilize standardized CWDM wavelengths. GBIC and SFP CWDM optics allow a legacy switch system to be "converted" to enable wavelength multiplexed transport over a fiber by selecting compatible transceiver wavelengths for use with an inexpensive passive optical multiplexing device.
The
10GBASE-LX4 10 Gbit/s
physical layer
In the seven-layer OSI model of computer networking, the physical layer or layer 1 is the first and lowest layer; The layer most closely associated with the physical connection between devices. This layer may be implemented by a PHY chip.
The ...
standard is an example of a CWDM system in which four wavelengths near 1310 nm, each carrying a 3.125 gigabit-per-second (Gbit/s) data stream, are used to carry 10 Gbit/s of aggregate data.
Passive CWDM is an implementation of CWDM that uses no electrical power. It separates the wavelengths using passive optical components such as bandpass filters and prisms. Many manufacturers are promoting passive CWDM to deploy fiber to the home.
Dense WDM
''Dense wavelength division multiplexing'' (DWDM) refers originally to optical signals multiplexed within the 1550 nm band so as to leverage the capabilities (and cost) of
erbium doped fiber amplifiers (EDFAs), which are effective for wavelengths between approximately 1525–1565 nm (
C band), or 1570–1610 nm (
L band
The L band is the Institute of Electrical and Electronics Engineers (IEEE) designation for the range of frequencies in the radio spectrum from 1 to 2 gigahertz (GHz). This is at the top end of the ultra high frequency (UHF) band, at the lower en ...
). EDFAs were originally developed to replace
SONET/SDH
Synchronous optical networking (SONET) and synchronous digital hierarchy (SDH) are standardized protocols that transfer multiple digital bit streams synchronously over optical fiber using lasers or highly coherent light from light-emitting diod ...
optical-electrical-optical (OEO)
regenerators, which they have made practically obsolete. EDFAs can amplify any optical signal in their operating range, regardless of the modulated bit rate. In terms of multi-wavelength signals, so long as the EDFA has enough pump energy available to it, it can amplify as many optical signals as can be multiplexed into its amplification band (though signal densities are limited by choice of modulation format). EDFAs therefore allow a single-channel optical link to be upgraded in bit rate by replacing only equipment at the ends of the link, while retaining the existing EDFA or series of EDFAs through a long haul route. Furthermore, single-wavelength links using EDFAs can similarly be upgraded to WDM links at reasonable cost. The EDFA's cost is thus leveraged across as many channels as can be multiplexed into the 1550 nm band.
DWDM systems
At this stage, a basic DWDM system contains several main components:
# A DWDM terminal multiplexer. The terminal multiplexer contains a wavelength-converting transponder for each data signal, an optical multiplexer and where necessary an optical amplifier (EDFA). Each wavelength-converting transponder receives an optical data signal from the client-layer, such as Synchronous optical networking
ONET /SDHor another type of data signal, converts this signal into the electrical domain and re-transmits the signal at a specific wavelength using a 1,550 nm band laser. These data signals are then combined into a multi-wavelength optical signal using an optical multiplexer, for transmission over a single fiber (e.g., SMF-28 fiber). The terminal multiplexer may or may not also include a local transmit EDFA for power amplification of the multi-wavelength optical signal. In the mid-1990s DWDM systems contained 4 or 8 wavelength-converting transponders; by 2000 or so, commercial systems capable of carrying 128 signals were available.
# An intermediate line repeater is placed approximately every 80–100 km to compensate for the loss of optical power as the signal travels along the fiber. The 'multi-wavelength optical signal' is amplified by an EDFA, which usually consists of several amplifier stages.
# An intermediate optical terminal, or optical add-drop multiplexer. This is a remote amplification site that amplifies the multi-wavelength signal that may have traversed up to 140 km or more before reaching the remote site. Optical diagnostics and telemetry are often extracted or inserted at such a site, to allow for localization of any fiber breaks or signal impairments. In more sophisticated systems (which are no longer point-to-point), several signals out of the multi-wavelength optical signal may be removed and dropped locally.
# A DWDM terminal demultiplexer. At the remote site, the terminal de-multiplexer consisting of an optical de-multiplexer and one or more wavelength-converting transponders separates the multi-wavelength optical signal back into individual data signals and outputs them on separate fibers for client-layer systems (such as
SONET/SDH
Synchronous optical networking (SONET) and synchronous digital hierarchy (SDH) are standardized protocols that transfer multiple digital bit streams synchronously over optical fiber using lasers or highly coherent light from light-emitting diod ...
). Originally, this de-multiplexing was performed entirely passively, except for some telemetry, as most SONET systems can receive 1,550 nm signals. However, in order to allow for transmission to remote client-layer systems (and to allow for digital domain signal integrity determination) such de-multiplexed signals are usually sent to O/E/O output transponders prior to being relayed to their client-layer systems. Often, the functionality of output transponder has been integrated into that of input transponder, so that most commercial systems have transponders that support bi-directional interfaces on both their 1,550 nm (i.e., internal) side, and external (i.e., client-facing) side. Transponders in some systems supporting 40 GHz nominal operation may also perform
forward error correction
In computing, telecommunication, information theory, and coding theory, an error correction code, sometimes error correcting code, (ECC) is used for controlling errors in data over unreliable or noisy communication channels. The central idea is ...
(FEC) via
digital wrapper technology, as described in the
ITU-T
The ITU Telecommunication Standardization Sector (ITU-T) is one of the three sectors (divisions or units) of the International Telecommunication Union (ITU). It is responsible for coordinating standards for telecommunications and Information Comm ...
G.709
ITU-T Recommendation G.709 ''Interfaces for the Optical Transport Network (OTN)'' describes a means of communicating data over an optical network. It is a standardized method for transparent transport of services over optical wavelengths in DWD ...
standard.
# Optical Supervisory Channel (OSC). This is data channel which uses an additional wavelength usually outside the EDFA amplification band (at 1,510 nm, 1,620 nm, 1,310 nm or another proprietary wavelength). The OSC carries information about the multi-wavelength optical signal as well as remote conditions at the optical terminal or EDFA site. It is also normally used for remote software upgrades and user (i.e., network operator) Network Management information. It is the multi-wavelength analogue to SONET's DCC (or supervisory channel). ITU standards suggest that the OSC should utilize an OC-3 signal structure, though some vendors have opted to use 100 megabit Ethernet or another signal format. Unlike the 1550 nm multi-wavelength signal containing client data, the OSC is always terminated at intermediate amplifier sites, where it receives local information before re-transmission.
The introduction of the ITU-T G.694.1
frequency grid For telecommunications, a frequency grid is a table of all the central frequencies (and corresponding wavelengths) of channels allowed in a communications system.
The most common frequency grid used for fiber-optic communication is that used for ...
in 2002 has made it easier to integrate WDM with older but more standard
SONET/SDH
Synchronous optical networking (SONET) and synchronous digital hierarchy (SDH) are standardized protocols that transfer multiple digital bit streams synchronously over optical fiber using lasers or highly coherent light from light-emitting diod ...
systems. WDM wavelengths are positioned in a grid having exactly 100 GHz (about 0.8 nm) spacing in optical frequency, with a reference frequency fixed at 193.10 THz (1,552.52 nm). The main grid is placed inside the optical fiber amplifier bandwidth, but can be extended to wider bandwidths. The first commercial deployment of DWDM was made by Ciena Corporation on the Sprint network in June 1996. Today's DWDM systems use 50 GHz or even 25 GHz channel spacing for up to 160 channel operation.
DWDM systems have to maintain more stable wavelength or frequency than those needed for CWDM because of the closer spacing of the wavelengths. Precision temperature control of laser transmitter is required in DWDM systems to prevent "drift" off a very narrow frequency window of the order of a few GHz. In addition, since DWDM provides greater maximum capacity it tends to be used at a higher level in the communications hierarchy than CWDM, for example on the
Internet backbone
The Internet backbone may be defined by the principal data routes between large, strategically interconnected computer networks and core routers of the Internet. These data routes are hosted by commercial, government, academic and other high-ca ...
and is therefore associated with higher modulation rates, thus creating a smaller market for DWDM devices with very high performance. These factors of smaller volume and higher performance result in DWDM systems typically being more expensive than CWDM.
Recent innovations in DWDM transport systems include pluggable and software-tunable transceiver modules capable of operating on 40 or 80 channels. This dramatically reduces the need for discrete spare pluggable modules, when a handful of pluggable devices can handle the full range of wavelengths.
Wavelength-converting transponders
At this stage, some details concerning wavelength-converting transponders should be discussed, as this will clarify the role played by current DWDM technology as an additional optical transport layer. It will also serve to outline the evolution of such systems over the last 10 or so years.
As stated above, wavelength-converting transponders served originally to translate the transmit wavelength of a client-layer signal into one of the DWDM system's internal wavelengths in the 1,550 nm band (note that even external wavelengths in the 1,550 nm will most likely need to be translated, as they will almost certainly not have the required frequency stability tolerances nor will it have the optical power necessary for the system's EDFA).
In the mid-1990s, however, wavelength converting transponders rapidly took on the additional function of
signal regeneration In telecommunications, signal regeneration is signal processing that restores a signal, recovering its original characteristics.
The signal may be electrical, as in a repeater on a T-carrier line, or optical
Optics is the branch of physics tha ...
. Signal regeneration in transponders quickly evolved through 1R to 2R to 3R and into overhead-monitoring multi-bitrate 3R regenerators. These differences are outlined below:
; 1R: Retransmission. Basically, early transponders were "garbage in garbage out" in that their output was nearly an analogue "copy" of the received optical signal, with little signal cleanup occurring. This limited the reach of early DWDM systems because the signal had to be handed off to a client-layer receiver (likely from a different vendor) before the signal deteriorated too far. Signal monitoring was basically confined to optical domain parameters such as received power.
; 2R: Re-time and re-transmit. Transponders of this type were not very common and utilized a quasi-digital
Schmitt-triggering method for signal clean-up. Some rudimentary signal-quality monitoring was done by such transmitters that basically looked at analogue parameters.
; 3R: Re-time, re-transmit, re-shape. 3R Transponders were fully digital and normally able to view
SONET/SDH
Synchronous optical networking (SONET) and synchronous digital hierarchy (SDH) are standardized protocols that transfer multiple digital bit streams synchronously over optical fiber using lasers or highly coherent light from light-emitting diod ...
section layer overhead bytes such as A1 and A2 to determine signal quality health. Many systems will offer 2.5 Gbit/s transponders, which will normally mean the transponder is able to perform 3R regeneration on OC-3/12/48 signals, and possibly gigabit Ethernet, and reporting on signal health by monitoring SONET/SDH section layer overhead bytes. Many transponders will be able to perform full multi-rate 3R in both directions. Some vendors offer 10 Gbit/s transponders, which will perform Section layer overhead monitoring to all rates up to and including OC-192.
; Muxponder: The
muxponder In optical fiber communications, a muxponder is the element that sends and receives the optical signal on a fiber in much the same way as a transponder except that the muxponder has the additional functionality of multiplexing
In telecommunic ...
(from multiplexed transponder) has different names depending on vendor. It essentially performs some relatively simple time-division multiplexing of lower-rate signals into a higher-rate carrier within the system (a common example is the ability to accept 4 OC-48s and then output a single OC-192 in the 1,550 nm band). More recent muxponder designs have absorbed more and more TDM functionality, in some cases obviating the need for traditional
SONET/SDH
Synchronous optical networking (SONET) and synchronous digital hierarchy (SDH) are standardized protocols that transfer multiple digital bit streams synchronously over optical fiber using lasers or highly coherent light from light-emitting diod ...
transport equipment.
List of DWDM Channels
For DWDM the range between C21-C60 is the most common range, for Mux/Demux in 8, 16, 40 or 96 sizes.
Reconfigurable optical add-drop multiplexer (ROADM)
As mentioned above, intermediate optical amplification sites in DWDM systems may allow for the dropping and adding of certain wavelength channels. In most systems deployed as of August 2006 this is done infrequently, because adding or dropping wavelengths requires manually inserting or replacing wavelength-selective cards. This is costly, and in some systems requires that all active traffic be removed from the DWDM system, because inserting or removing the wavelength-specific cards interrupts the multi-wavelength optical signal.
With a ROADM, network operators can remotely reconfigure the multiplexer by sending soft commands. The architecture of the ROADM is such that dropping or adding wavelengths does not interrupt the "pass-through" channels. Numerous technological approaches are utilized for various commercial ROADMs, the tradeoff being between cost, optical power, and flexibility.
Optical cross connects (OXCs)
When the network topology is a mesh, where nodes are interconnected by fibers to form an arbitrary graph, an additional fiber interconnection device is needed to route the signals from an input port to the desired output port. These devices are called optical crossconnectors (OXCs). Various categories of OXCs include electronic ("opaque"), optical ("transparent"), and wavelength selective devices.
Enhanced WDM
Cisco
Cisco Systems, Inc., commonly known as Cisco, is an American-based multinational digital communications technology conglomerate corporation headquartered in San Jose, California. Cisco develops, manufactures, and sells networking hardware, ...
's Enhanced WDM system combines 1 Gb Coarse Wave Division Multiplexing (CWDM) connections using SFPs and GBICs with 10 Gb Dense Wave Division Multiplexing (DWDM) connections using
XENPAK XENPAK is a multisource agreement (MSA), instigated by Agilent Technologies and Agere Systems, that defines a fiber-optic or wired transceiver module which conforms to the 10 Gigabit Ethernet (10GbE) standard of the Institute of Electrical and Elec ...
,
X2 or
XFP
The XFP (10 gigabit small form-factor pluggable) is a standard for transceivers for high-speed computer network and telecommunication links that use optical fiber. It was defined by an industry group in 2002, along with its interface to other e ...
DWDM modules. These DWDM connections can either be passive or boosted to allow a longer range for the connection. In addition to this, CFP modules deliver 100 Gbit/s Ethernet suitable for high speed Internet backbone connections.
Shortwave WDM
Shortwave WDM uses
vertical-cavity surface-emitting laser
The vertical-cavity surface-emitting laser, or VCSEL , is a type of semiconductor laser diode with laser beam emission perpendicular from the top surface, contrary to conventional edge-emitting semiconductor lasers (also ''in-plane'' lasers) which ...
(VCSEL) transceivers with four wavelengths in the 846 to 953 nm range over single OM5 fiber, or 2-fiber connectivity for OM3/OM4 fiber.
Transceivers versus transponders
; Transceivers: Since communication over a single wavelength is one-way (
simplex communication
Simplex communication is a communication channel that sends information in one direction only."Simplex" ''The IEEE Authoritative Dictionary of Standard Terms, 7th Ed.'', 2000, Inst. of Electrical and Electronic Engineers, p.1053
The Internationa ...
), and most practical communication systems require two-way (
duplex communication) communication, two wavelengths will be required if on the same fiber; if separate fibers are used in a so-called fiber pair, then the same wavelength is normally used and it is not WDM. As a result, at each end both a transmitter and a receiver will be required. A combination of a transmitter and a receiver is called a transceiver; it converts an electrical signal to and from an optical signal. WDM transceivers made for single-strand operation require the opposing transmitters to use different wavelengths. WDM transceivers additionally require an optical splitter/combiner to couple the transmitter and receiver paths onto the one fiber strand.
; Transponder: In practice, the signal inputs and outputs will not be electrical but optical instead (typically at 1550 nm). This means that in effect wavelength converters are needed instead, which is exactly what a transponder is. A transponder can be made up of two transceivers placed after each other: the first transceiver converting the 1550 nm optical signal to/from an electrical signal, and the second transceiver converting the electrical signal to/from an optical signal at the required wavelength. Transponders that don't use an intermediate electrical signal (all-optical transponders) are in development.
See also
transponders (optical communications) for different functional views on the meaning of optical transponders.
Implementations
There are several simulation tools that can be used to design WDM systems.
See also
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
References
*Siva Ram Murthy C.; Guruswamy M., "WDM Optical Networks, Concepts, Design, and Algorithms", Prentice Hall India, .
*Tomlinson, W. J.; Lin, C., "Optical wavelength-division multiplexer for the 1–1.4-micron spectral region", Electronics Letters, vol. 14, May 25, 1978, p. 345–347
adsabs.harvard.edu*Ishio, H. Minowa, J. Nosu, K., "Review and status of wavelength-division-multiplexing technology and its application", Journal of Lightwave Technology, Volume: 2, Issue: 4, Aug 1984, p. 448–463
*Cheung, Nim K.; Nosu Kiyoshi; Winzer, Gerhard "Guest Editorial / Dense Wavelength Division Multiplexing Techniques for High Capacity and Multiple Access Communication Systems", IEEE Journal on Selected Areas in Communications, Vol. 8 No. 6, August 1990 .
*Arora, A.; Subramaniam, S. "Wavelength Conversion Placement in WDM Mesh Optical Networks". Photonic Network Communications, Volume 4, Number 2, May 2002.
*First discussion: O. E. Delange, "Wideband optical communication systems, Part 11-Frequency division multiplexing". hoc. IEEE, vol. 58, p. 1683, October 1970.
{{DEFAULTSORT:Wavelength-Division Multiplexing
Fiber-optic communications
Multiplexing
Channel access methods