A vapor barrier (or vapour barrier) is any material used for damp proofing, typically a plastic or foil sheet, that resists diffusion of moisture through the wall, floor, ceiling, or roof assemblies of buildings and of packaging to prevent interstitial condensation. Technically, many of these materials are only vapor retarders as they have varying degrees of permeability. Materials have a moisture vapor transmission rate (MVTR) that is established by standard test methods. One common set of units is g/m2·day or g/100in2·day. Permeability can be reported in perms, a measure of the rate of transfer of water vapor through a material (1.0 US perm = 1.0 grain/square-foot·hour· inch of mercury ≈ 57 SI perm = 57 ng/s·m2·Pa). American building codes have classified vapor retarders as having a water vapor permeance of 1 perm or less when tested in accordance with the ASTM E96 desiccant, or dry cup method. Vapor-retarding materials are generally categorized as: *''Impermeable'' (≤1 US perm, or ≤57 SI perm) – such as asphalt-backed kraft paper, elastomeric coating, vapor-retarding paint, oil-based paints, vinyl wall coverings, extruded polystyrene, plywood, OSB; *''Semi-permeable'' (1-10 US perm, or 57-570 SI perm) – such as unfaced expanded polystyrene, fiber-faced
isocyanurate Cyanuric acid or 1,3,5-triazine-2,4,6-triol is a chemical compound with the formula (CNOH)3. Like many industrially useful chemicals, this triazine has many synonyms. This white, odorless solid finds use as a precursor or a component of bleaches ...
, heavy asphalt-impregnated building papers, some latex-based paints); *''Permeable'' (>10 US perm, or >570 SI perm) – such as unpainted gypsum board and plaster, unfaced fiber glass insulation, cellulose insulation, unpainted stucco, cement sheathings, spunbonded polyolefin or some polymer-based exterior air barrier films.


Materials

Vapor diffusion retarders are normally available as coatings or membranes. The membranes are technically flexible and thin materials, but sometime includes thicker sheet materials named as "structural" vapor diffusion retarders. The vapor diffusion retarders varies from all kinds of materials and keep updating every day, some of them nowadays even combined the functions of other building materials. Materials used as vapor retarders: * Elastomeric coatings can provide a vapor barrier and water proofing with permeability ratings of .016 perm rating with 10 mils/min. of coating and can be applied on interior or exterior surfaces. *
Aluminum foil Aluminium foil (or aluminum foil in North American English; often informally called tin foil) is aluminium prepared in thin metal leaves with a thickness less than ; thinner gauges down to are also commonly used. Standard household foil is ty ...
, 0.05 US perm (2.9 SI perm). * Paper-backed aluminum. *
Asphalt Asphalt, also known as bitumen (, ), is a sticky, black, highly viscous liquid or semi-solid form of petroleum. It may be found in natural deposits or may be a refined product, and is classed as a pitch. Before the 20th century, the term a ...
or
coal tar pitch Coal tar is a thick dark liquid which is a by-product of the production of coke and coal gas from coal. It is a type of creosote. It has both medical and industrial uses. Medicinally it is a topical medication applied to skin to treat psoriasis ...
, typically hot-applied to concrete roof decks along with reinforcement felts. * Polyethylene plastic sheet, , 0.03 US perm (1.7 SI perm). * Advanced Polyethylene vapor retarders that pass the ASTM E 1745 standard tests ≤0.3 US perm (17 SI perm). * Asphalt-coated kraft paper, often attached to one side of fiberglass batts, 0.40 US perm (22 SI perm). * Metallized film * Vapor retarder paints (for the air-tight drywall system, for retrofits where finished walls and ceilings will not be replaced, or for dry basements: can break down over time due to being chemically based). *
Extruded polystyrene Polystyrene (PS) is a synthetic polymer made from monomers of the aromatic hydrocarbon styrene. Polystyrene can be solid or foamed. General-purpose polystyrene is clear, hard, and brittle. It is an inexpensive resin per unit weight. It is a ...
or foil-faced foam board insulation. * Exterior grade plywood, 0.70 US perm (40 SI perm). * Most sheet type monolithic roofing membranes. * Glass and metal sheets (such as in doors and windows).


Building construction

Moisture or water vapor moves into building cavities in three ways: 1) With air currents, 2) By diffusion through materials, 3) By heat transfer. Of these three, air movement accounts for more than 98% of all water vapor movement in building cavities. A vapor retarder and an
air barrier Air barriers control air leakage into and out of the building envelope. Air barrier products may take several forms: *Mechanically-attached membranes, also known as housewraps, usually a polyethylene-fiber or spun-bonded polyolefin, such as Tyve ...
serve to reduce this problem, but are not necessarily interchangeable. Vapor retarders slow the rate of vapor diffusion into the thermal envelope of a structure. Other wetting mechanisms, such as wind-borne rain,
capillary A capillary is a small blood vessel from 5 to 10 micrometres (μm) in diameter. Capillaries are composed of only the tunica intima, consisting of a thin wall of simple squamous endothelial cells. They are the smallest blood vessels in the body: ...
wicking of ground moisture, air transport (
infiltration Infiltration may refer to: Science, medicine, and engineering *Infiltration (hydrology), downward movement of water into soil *Infiltration (HVAC), a heating, ventilation, and air conditioning term for air leakage into buildings *Infiltration (me ...
), are equally important.


Usage

The industry has recognized that in many circumstances it may be impractical to design and build building assemblies which never get wet. Good design and practice involve controlling the wetting of building assemblies from both the exterior and interior. So, the use of vapor barrier should be taken into consideration. Their use has already been legislated within the
building code A building code (also building control or building regulations) is a set of rules that specify the standards for constructed objects such as buildings and non-building structures. Buildings must conform to the code to obtain planning permissi ...
of some countries (such as the U.S., Canada, Ireland, England, Scotland & Wales). How, where, and whether a vapor barrier (vapor diffusion retarder) should be used depends on the climate. Typically, the number of
heating degree day Heating degree day (HDD) is a measurement designed to quantify the demand for energy needed to heat a building. HDD is derived from measurements of outside air temperature. The heating requirements for a given building at a specific location ar ...
s (HDD) in an area is used to help make these determinations. A heating degree day is a unit that measures how often outdoor daily dry-bulb temperatures fall below an assumed base, normally 18°C (65°F). For building in most parts of North America, where winter heating conditions predominate, vapor barrier are placed toward the interior, heated side of insulation in the assembly. In humid regions where warm-weather cooling predominates within buildings, the vapor barrier should be located toward the exterior side of insulation. In relatively mild or balanced climates, or where assemblies are designed to minimize condensation conditions, a vapor barrier may not be necessary at all. An interior vapor retarder is useful in heating-dominated climates while an exterior vapor retarder is useful in cooling-dominated climates. In most climates it is often better to have a vapor-open building assembly, meaning that walls and roofs should be designed to dry:The Perfect Wall, Roof, and Slab - Building Science Podcast
/ref> either to the inside, the outside, or both, so the ventilation of water vapor should be taken into consideration. A vapor barrier on the warm side of the envelope must be combined with a venting path on the cold side of the insulation. This is because no vapor barrier is perfect, and because water may get into the structure, typically from rain. In general, the better the vapor barrier and the drier the conditions, the less venting is required. In areas below foundation level ( subgrade areas), particularly those formed in concrete, vapor retarder placement can be problematic, as moisture infiltration from capillary action can exceed water vapor movement outward through framed and insulated walls. A slab-on-grade or basement floor should be poured over a cross-laminated polyethylene vapor barrier over of granular fill to prevent wicking of moisture from the ground and radon gas incursion. Inside a steel building, water vapor will condense whenever it comes into contact with a surface that is below the dew point temperature. Visible condensation on windowpanes and purlins that results in dripping can be somewhat mitigated with ventilation; however insulation is the preferred method of condensation prevention.


Confusion with air barrier

The function of a vapor barrier is to retard the migration of water vapor. A vapor barrier is not typically intended to retard the migration of air. This is the function of
air barriers Air barriers control air leakage into and out of the building envelope. Air barrier products may take several forms: *Mechanically-attached membranes, also known as housewraps, usually a polyethylene-fiber or spun-bonded polyolefin, such as Tyve ...
. Air is mixed with water vapor. When air moves from location to location due to an air pressure difference, the vapor moves with it. This is a type of migration of water vapor. In the strictest sense air barriers are also vapor barriers when they control the transport of moisture-laden air. It must be mentioned that the designated perm ratings do not reflect the diminished permeability of a given vapor retarder medium when affected by temperature differences on opposing sides of the medium. A discussion about the differences between vapor barriers and air barriers can be found in Quirouette.


Packaging

The ability of a package to control the
permeation In physics and engineering, permeation (also called imbuing) is the penetration of a permeate (a fluid such as a liquid, gas, or vapor) through a solid. It is directly related to the concentration gradient of the permeate, a material's intrins ...
and penetration of gasses is vital for many types of products. Tests are often conducted on the packaging materials but also on the completed packages, sometimes after being subjected to flexing, handling, vibration, or temperature.


See also

*
Air barrier Air barriers control air leakage into and out of the building envelope. Air barrier products may take several forms: *Mechanically-attached membranes, also known as housewraps, usually a polyethylene-fiber or spun-bonded polyolefin, such as Tyve ...
* Heating, ventilation, and air conditioning (HVAC) *
Infiltration Infiltration may refer to: Science, medicine, and engineering *Infiltration (hydrology), downward movement of water into soil *Infiltration (HVAC), a heating, ventilation, and air conditioning term for air leakage into buildings *Infiltration (me ...


References

* Fine Homebuilding No. 169 March 2005 p. 78 * Fine Homebuilding No. 162, May 2004 p. 52


External links


Air Barriers vs. Vapor BarriersConsumer's Guide to Vapor Barriers
at the U.S. Department of Energy {{HVAC Moisture protection Psychrometrics Heating, ventilation, and air conditioning