HOME

TheInfoList



OR:

A volume unit (VU) meter or standard volume indicator (SVI) is a device displaying a representation of the
signal level Signal-to-noise ratio (SNR or S/N) is a measure used in science and engineering that compares the level of a desired signal to the level of background noise. SNR is defined as the ratio of signal power to the noise power, often expressed in deci ...
in
audio Audio most commonly refers to sound, as it is transmitted in signal form. It may also refer to: Sound * Audio signal, an electrical representation of sound *Audio frequency, a frequency in the audio spectrum * Digital audio, representation of sou ...
equipment. The original design was proposed in the 1940
IRE Ire or IRE may refer to: Ire * Extreme anger; intense fury * Irē, the Livonian name for Mazirbe, Latvia * A town in Oye, Nigeria * ''Ire'' (album), a 2015 album by the Australian metalcore band Parkway Drive * Ire (Iliad), a town mentioned in ...
paper, ''A New Standard Volume Indicator and Reference Level'', written by experts from
CBS CBS Broadcasting Inc., commonly shortened to CBS, the abbreviation of its former legal name Columbia Broadcasting System, is an American commercial broadcast television and radio network serving as the flagship property of the CBS Entertainm ...
,
NBC The National Broadcasting Company (NBC) is an American English-language commercial broadcast television and radio network. The flagship property of the NBC Entertainment division of NBCUniversal, a division of Comcast, its headquarters are l ...
, and
Bell Telephone Laboratories Nokia Bell Labs, originally named Bell Telephone Laboratories (1925–1984), then AT&T Bell Laboratories (1984–1996) and Bell Labs Innovations (1996–2007), is an American industrial research and scientific development company owned by mult ...
. The
Acoustical Society of America The Acoustical Society of America (ASA) is an international scientific society founded in 1929 dedicated to generating, disseminating and promoting the knowledge of acoustics and its practical applications. The Society is primarily a voluntary org ...
then standardized it in 1942 (ANSI C16.5-1942) for use in telephone installation and radio broadcast stations. Consumer audio equipment often features VU meters, both for utility purposes (e.g. in recording equipment) and for aesthetics (in playback devices). The original VU meter is a passive electromechanical device, namely a 200 µA DC d'Arsonval movement
ammeter An ammeter (abbreviation of ''Ampere meter'') is an instrument used to measure the current in a circuit. Electric currents are measured in amperes (A), hence the name. For direct measurement, the ammeter is connected in series with the circuit ...
fed from a full-wave copper-oxide rectifier mounted within the meter case. The mass of the needle causes a relatively slow response, which in effect integrates or smooths the signal, with a
rise time In electronics, when describing a voltage or current step function, rise time is the time taken by a signal to change from a specified low value to a specified high value. These values may be expressed as ratiosSee for example , and . or, equivale ...
of 300 ms. This has the effect of averaging out peaks and troughs of short duration, and reflects the perceived
loudness In acoustics, loudness is the subjectivity, subjective perception of sound pressure. More formally, it is defined as, "That attribute of auditory sensation in terms of which sounds can be ordered on a scale extending from quiet to loud". The rel ...
of the material more closely than the more modern and initially more expensive PPM meters. For this reason many audio practitioners prefer the VU meter to its alternatives, though the meter indication does not reflect some of the key features of the signal, most notably its peak level, which in many cases, must not pass a defined limit. 0 VU is equal to +4 
dBu The decibel (symbol: dB) is a relative unit of measurement equal to one tenth of a bel (B). It expresses the ratio of two values of a Power, root-power, and field quantities, power or root-power quantity on a logarithmic scale. Two signals whose ...
, or 1.228 
volt The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). It is named after the Italian physicist Alessandro Volta (1745–1827). Defi ...
s RMS, a power of about 2.5 milliwatts when applied across a 600-
ohm Ohm (symbol Ω) is a unit of electrical resistance named after Georg Ohm. Ohm or OHM may also refer to: People * Georg Ohm (1789–1854), German physicist and namesake of the term ''ohm'' * Germán Ohm (born 1936), Mexican boxer * Jörg Ohm (b ...
load. 0 VU is often referred to as "0 dB". The meter was designed not to measure the signal, but to let users aim the signal level to a target level of 0 VU (sometimes labelled 100%), so it is not important that the device is non-linear and imprecise for low levels. In effect, the scale ranges from −20 VU to +3 VU, with −3 VU right in the middle (half the power of 0 VU). Purely electronic devices may emulate the response of the needle; they are VU-meters in as much as they respect the standard. In the broadcast industry,
loudness monitoring Loudness monitoring of programme levels is needed in radio and television broadcasting, as well as in audio post production. Traditional methods of measuring signal levels, such as the Peak programme meter and VU meter, do not give the subjective ...
was standardized, in 2009 in the United States by the ATSC A/85, in 2010 in Europe by the EBU R-128, in 2011 in Japan by the TR-B32, and in 2010 in Australia by the OP-59.


Lead

The original designers of the VU meter were tasked with finding a way to measure complex audio signals with a simple technology. Since a VU meter is a mechanical device, it can never reflect the instantaneous signal peaks of complex audio signals. The designers of the VU meter therefore took a different approach. They created a meter that did ''not'' measure peaks, but simply inferred them. A real VU meter has a very specific "ballistic characteristic". This means that it responds to changing audio signals at a very precise speed, rising from no signal to 99% of "0 VU" when a 1 kHz sine wave tone is applied for 300 milliseconds. When using a VU meter, the audio system is calibrated with a sine wave tone at a "reference level" for the system. At the reference level, the VU meter shows "0" for a sine-wave tone, but the engineer must know that, with music or speech, to always infer that peak levels are always between 6 dB and 10 dB higher than the reference level. The usefulness of the VU meter comes from the fact that for most types of audio sources the system engineer can count on these peaks being within this range and can design the audio system with confidence. Good engineering practice is to always build in a little extra "headroom", as it is called, to cover the strange conditions where an audio signal might exceed normal peak levels or the equipment operator fails to adjust the levels correctly. Typically the levels considered when designing systems using a VU meter are: * Reference level (typically +4 dBu, valid with tones only); * Standard output level (10 dB above reference, typical peak levels); * Clip level (6 dB above standard output level, "headroom" to allow for unusual conditions)


Standard characteristics

The behaviour of VU meters is defined in
ANSI The American National Standards Institute (ANSI ) is a private non-profit organization that oversees the development of voluntary consensus standards for products, services, processes, systems, and personnel in the United States. The organi ...
C16.5-1942,
British Standard British Standards (BS) are the standards produced by the BSI Group which is incorporated under a royal charter and which is formally designated as the national standards body (NSB) for the UK. The BSI Group produces British Standards under the a ...
BS 6840, and
IEC The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
60268-17.


Reference level


Rise time

The
rise time In electronics, when describing a voltage or current step function, rise time is the time taken by a signal to change from a specified low value to a specified high value. These values may be expressed as ratiosSee for example , and . or, equivale ...
, defined as the time it takes for the needle to reach 99% of the distance to 0 VU when the VU-meter is submitted to a signal that steps from 0 to a level that reads 0 VU, is 300 ms. The overshoot must be within 1 to 1.5%. The fall time is the same as the rise time, 300 ms.


Frequency response

The level specification is meant at 1000 Hz. The reading should not depart from the reading at 1000 Hz by more than 0.2 dB from 35 Hz to 10 kHz or more than 0.5 dB between 25 Hz and 16 kHz. Note that the specification mentions only sinusoid waveforms. Given the electromechanical principle of the meter, the deviation of the needle is actually approximately proportional to the ''average'' of the part of the signal with more than approximately 0.4 V instantaneously because of the two copper-oxide rectifiers always in series, which transfer function curve has a knee around 0.2 V. Signals generally do not have a sinusoidal waveform by far, even if they all fall within the VU-meter bandpass. The reading is the average of the voltage, and is not an indication of the power of the signal, which is proportional to the average of the square of the voltage, or the root-mean-square (RMS) value. As a conventional ''VU reading'', however, it served its purpose as an indication a) of the overall level and dynamics of the signal and b) of the proximity to the maximum admitted level, to the operators of recording and broadcasting equipment. Maintenance staff could also use it as a measurement apparatus, to check for losses in transmissions and level alignment, provided that they used exclusively sine waves as test signals.


Impedance

The VU meter and its attenuator should present a 7,500-ohm impedance to the circuit it is applied to, measured with a sinusoid signal that sets the indicator to 0 dB.


History

The VU-meter was originally developed in 1939 by the combined effort of
Bell Labs Nokia Bell Labs, originally named Bell Telephone Laboratories (1925–1984), then AT&T Bell Laboratories (1984–1996) and Bell Labs Innovations (1996–2007), is an American industrial research and scientific development company owned by mult ...
and broadcasters
CBS CBS Broadcasting Inc., commonly shortened to CBS, the abbreviation of its former legal name Columbia Broadcasting System, is an American commercial broadcast television and radio network serving as the flagship property of the CBS Entertainm ...
and
NBC The National Broadcasting Company (NBC) is an American English-language commercial broadcast television and radio network. The flagship property of the NBC Entertainment division of NBCUniversal, a division of Comcast, its headquarters are l ...
. In the 1970s–80s,
neon Neon is a chemical element with the symbol Ne and atomic number 10. It is a noble gas. Neon is a colorless, odorless, inert monatomic gas under standard conditions, with about two-thirds the density of air. It was discovered (along with krypton ...
-filled, planar dual displays with up to 201 segments per stereo channel were popular among broadcasters as fast bar graph VU meters.


Other level meters

The consumer audio industry often uses volume indicators that do not comply with any standard. BBC sound engineers would refer to the VU meter as the "Virtually Useless" meter, preferring the PPM. Academic research has shown that an SVI or VU meter behaves differently to the average value and RMS meters. The ballistics shown by this instrument in response to signals with large crest factor position its readings halfway between both. For example, an increment of 3 dB in the crest factor of an audio signal gives approximately a fall of −3 dB in a RMS meter, −6 dB in an average meter, and −4 dB in a VU meter.Method to Evaluate the Ballistics of Audio Meters
– Victor M. Acuña.


See also

* Audio equipment *
Crest factor Crest or CREST may refer to: Buildings *The Crest (Huntington, New York), a historic house in Suffolk County, New York *"The Crest", an alternate name for 63 Wall Street, in Manhattan, New York * Crest Castle (Château Du Crest), Jussy, Switzer ...
*
Decibel The decibel (symbol: dB) is a relative unit of measurement equal to one tenth of a bel (B). It expresses the ratio of two values of a power or root-power quantity on a logarithmic scale. Two signals whose levels differ by one decibel have a po ...
*
Loudness monitoring Loudness monitoring of programme levels is needed in radio and television broadcasting, as well as in audio post production. Traditional methods of measuring signal levels, such as the Peak programme meter and VU meter, do not give the subjective ...
*
Mixing console A mixing console or mixing desk is an electronic device for mixing audio signals, used in sound recording and reproduction and sound reinforcement systems. Inputs to the console include microphones, signals from electric or electronic inst ...
*
Noise pollution Noise pollution, also known as environmental noise or sound pollution, is the propagation of noise with ranging impacts on the activity of human or animal life, most of them are harmful to a degree. The source of outdoor noise worldwide is main ...
*
Nominal level Nominal level is the operating level at which an electronic signal processing device is designed to operate. The electronic circuits that make up such equipment are limited in the maximum signal they can handle and the low-level internally genera ...
*
Peak meter A peak meter is a type of measuring instrument that indicates visually the instantaneous level of an audio signal that is passing through it (a sound level meter). In sound reproduction, the meter, whether peak or not, is usually meant to corres ...
*
Peak programme meter A peak programme meter (PPM) is an instrument used in professional audio that indicates the level of an audio signal. Different kinds of PPM fall into broad categories: *True peak programme meter. This shows the peak level of the waveform no ...
*
Programme level {{Unreferenced, date=November 2009 Programme level refers to the signal level that an audio source is transmitted or recorded at, and is important in audio if listeners of Compact Discs (CDs), radio and television are to get the best experience, w ...


References


External links


AES Pro Audio Reference definition for VU meterA New Standard Volume Indicator and Reference Level
by Chinn, Gannett & Morris
The Bewildering Wilderness - "Navigating the complicated and frustrating world of audio standards"VU Meter Video
{{Electrical and electronic measuring equipment Sound production technology Measuring instruments