Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an
HVAC Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HV ...
technology invented by Daikin Industries, Ltd. in 1982. Like ductless minisplits, VRFs use
refrigerant A refrigerant is a working fluid used in the heat pump and refrigeration cycle, refrigeration cycle of air conditioning systems and heat pumps where in most cases they undergo a repeated phase transition from a liquid to a gas and back again. Ref ...
as the cooling and heating medium. This refrigerant is conditioned by one or more condensing units (which may be outdoors or indoors, water or air cooled), and is circulated within the building to multiple indoor units. VRF systems, unlike conventional chiller-based systems, allow for varying degrees of cooling in more specific areas (because there are no large air handlers, only smaller indoor units), may supply hot water in a heat recovery configuration without affecting efficiency, and switch to heating mode (heat pump) during winter without additional equipment, all of which may allow for reduced energy consumption. Also, air handlers and large ducts are not used which can reduce the height above a dropped ceiling as well as structural impact as VRF uses smaller penetrations for refrigerant pipes instead of ducts.


Description

VRFs are typically installed with an
air conditioner inverter A power inverter, inverter or invertor is a power electronic device or circuitry that changes direct current (DC) to alternating current (AC). The resulting AC frequency obtained depends on the particular device employed. Inverters do the oppo ...
which adds a DC inverter to the compressor in order to support variable motor speed and thus variable
refrigerant A refrigerant is a working fluid used in the heat pump and refrigeration cycle, refrigeration cycle of air conditioning systems and heat pumps where in most cases they undergo a repeated phase transition from a liquid to a gas and back again. Ref ...
flow rather than simply perform on/off operation. By operating at varying speeds, VRF units work only at the needed rate allowing for substantial energy savings at load conditions. Heat recovery VRF technology allows individual indoor units to heat or cool as required, while the
compressor A compressor is a mechanical device that increases the pressure of a gas by reducing its volume. An air compressor is a specific type of gas compressor. Compressors are similar to pumps: both increase the pressure on a fluid and both can transp ...
load benefits from the internal heat recovery. Energy savings of up to 55% are predicted over comparable unitary equipment. This also results in greater control of the building's interior temperature by the building's occupants. The lower start-up power of VRF's DC inverter compressors and their inherent DC power requirements also allow VRF solar-powered heat pumps to be run using DC-providing solar panels. VRFs come in two system formats, two pipe and three pipe systems. In a heat pump two pipe system all of the zones must either be all in cooling or all in heating. Heat Recovery (HR) systems have the ability to simultaneously heat certain zones while cooling others; this is usually done through a three pipe design, with the exception of Mitsubishi, Carrier and LG whose systems are able to do this with a two pipe system using a branch circuit (BC) controller to the individual indoor evaporator zones. In this case the heat extracted from zones requiring cooling is put to use in the zones requiring heating. This is made possible because the heating unit is functioning as a condenser, providing sub-cooled liquid back into the line that is being used for cooling. While the heat recovery system has a greater initial cost, it allows for better zoned thermal control of a building and overall greater efficiencies.Goetzler (April 2007). "Variable Refrigerant Flow Systems". ''ASHRAE Journal'': 24–31. In heat recovery VRF systems, some of the indoor units may be in cooling mode while others are in heating mode, reducing energy consumption. If the coefficient of performance in cooling mode of a system is 3, and the coefficient of performance in heating mode is 4, then heat recovery performance can reach more than 7. While it is unlikely that this balance of cooling and heating demand will happen often throughout the year, energy efficiency can be greatly improved when the scenario occurs.Rostamabadi, Mehrdad (2017). ''VRF HVAC Systems''. Shafaf. VRF systems may be air or water cooled. If air cooled, VRF condensing units are exposed to outside air and may be outdoors, and condensing units are the size of large refrigerators, since they need to contain a large condenser (heat exchanger) which has a large surface area to transfer heat to the surrounding air, because air doesn't have a high heat capacity and has a low density, volumetric thermal capacity and thermal conductivity thus needing to transfer heat into a large amount of air volume at once. If water cooled, the condensing units are placed indoors and are much smaller and cooled with water by a closed type or circuit cooling tower or dry cooler.


Japan

VRF systems have been used in Japan since the 1980s. By 2007, in Japan, VRFs are used in 50% of midsize office buildings (up to 70,000 ft2 or 6,500 m2) and 33% of large commercial buildings (more than 70,000 ft2 or 6,500 m2). Daikin, a Japanese company, is the inventor of variable refrigerant volume systems (or VRV by Daikin air conditioning, other manufacturers remarketed this as VRF as VRV is a trademark).


Home automation integration

There are dedicated gateways that connect VRFs with
home automation Home automation or domotics is building automation for a home, called a smart home or smart house. A home automation system will monitor and/or control home attributes such as lighting, climate, entertainment systems, and appliances. It m ...
and building management systems (BMS) controllers for centralized control and monitoring. In addition, such gateway solutions are capable of providing remote control operation of all
HVAC Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HV ...
indoor units over the internet incorporating a simple and friendly user interface.


Primary manufacturers

Japan: *
Daikin is a Japanese multinational air conditioning manufacturing company headquartered in Osaka. It has operations in Japan, China, Australia, the United States, India, Southeast Asia, Europe, the Middle East, Latin America, and Africa. Daikin is th ...
* Panasonic * Mitsubishi Heavy Industries *
Fujitsu is a Japanese multinational information and communications technology equipment and services corporation, established in 1935 and headquartered in Tokyo. Fujitsu is the world's sixth-largest IT services provider by annual revenue, and the la ...
(Fujitsu General) *
Hitachi () is a Japanese multinational corporation, multinational Conglomerate (company), conglomerate corporation headquartered in Chiyoda, Tokyo, Japan. It is the parent company of the Hitachi Group (''Hitachi Gurūpu'') and had formed part of the Ni ...
(Now Johnson Controls-Hitachi (Air Conditioning) (Jci-Hitachi) *
Mitsubishi Electric , established on 15 January 1921, is a Japanese multinational electronics and electrical equipment manufacturing company headquartered in Tokyo, Japan. It is one of the core companies of Mitsubishi. The products from MELCO include elevators an ...

Finpower Aircon LLC
* Toshiba * Yanmar (gas heat pumps) *
Sharp Sharp or SHARP may refer to: Acronyms * SHARP (helmet ratings) (Safety Helmet Assessment and Rating Programme), a British motorcycle helmet safety rating scheme * Self Help Addiction Recovery Program, a charitable organisation founded in 199 ...
(former) * Sanyo(now Panasonic) *
Toshiba Carrier , commonly known as Toshiba and stylized as TOSHIBA, is a Japanese multinational conglomerate corporation headquartered in Minato, Tokyo, Japan. Its diversified products and services include power, industrial and social infrastructure systems, ...
(Former Air-conditioning & Heating International (AHI)(AHI-Carrier/Toshiba) (Toshiba-Carrier) (As of 2018, the joint venture(s) seem to have been broken up, as Carrier now manufactures VRF systems of its own and Toshiba's websites no longer show the Carrier logo in their product images (which is not the case in some of Carrier's images) and web pages, and the AHI-Carrier(Toshiba) website has not been updated since 2016) Korea: * LG * Samsung India: * Blue Star Limited * Voltas * SB Cooling Corporation Italy: * Innova SRL United States: * Ephoca * Innovair * Carrier (Made by Toshiba) * York International(Made by Hitachi) * Trane (formerly made by Samsung, now made by Mitsubishi Electric) * Lennox * Afka Group (American Pro) * CIAC(Carrier) France: * Airwell China/Other: *
Acson Acson Malaysia Sales & Service Sdn Bhd is a Malaysian air conditioner brand and a subsidiary of Daikin. History It was founded in 1984 and was known as O.Y.L. Manufacturing Company Sdn. Bhd. The company was acquired by Daikin is a Japanese m ...
* Gree * Tosot * Haier * Hisense *
Inventor An invention is a unique or novel device, method, composition, idea or process. An invention may be an improvement upon a machine, product, or process for increasing efficiency or lowering cost. It may also be an entirely new concept. If an ...
*
Midea Midea may refer to: * Midea Group (美的集团), a Chinese electrical appliance manufacturer * Midea, Greece, a Greek town * Midea (Argolid), a citadel in the town of the same name * Midea or Mideia, name of four figures in Greek mythology * '' ...
* Bright * Dekon * ALKKT * Chigo
Ecox
* Bosch (made by Midea)


References

{{HVAC , state=collapsed Heating, ventilation, and air conditioning