Time-correlated Single Photon Counting
   HOME

TheInfoList



OR:

Ultrafast laser spectroscopy is a
spectroscopic Spectroscopy is the field of study that measures and interprets the electromagnetic spectra that result from the interaction between electromagnetic radiation and matter as a function of the wavelength or frequency of the radiation. Matter wa ...
technique that uses
ultrashort pulse In optics, an ultrashort pulse, also known as an ultrafast event, is an electromagnetic pulse whose time duration is of the order of a picosecond (10−12 second) or less. Such pulses have a broadband optical spectrum, and can be created by m ...
laser A laser is a device that emits light through a process of optical amplification based on the stimulated emission of electromagnetic radiation. The word "laser" is an acronym for "light amplification by stimulated emission of radiation". The fi ...
s for the study of dynamics on extremely short time scales ( attoseconds to
nanosecond A nanosecond (ns) is a unit of time in the International System of Units (SI) equal to one billionth of a second, that is, of a second, or 10 seconds. The term combines the SI prefix ''nano-'' indicating a 1 billionth submultiple of an SI unit ( ...
s). Different methods are used to examine the dynamics of charge carriers, atoms, and molecules. Many different procedures have been developed spanning different time scales and photon energy ranges; some common methods are listed below.


Attosecond-to-picosecond spectroscopy

Dynamics on the as to fs time scale are in general too fast to be measured electronically. Most measurements are done by employing a sequence of ultrashort light pulses to initiate a process and record its dynamics. The temporal width (duration) of the light pulses has to be on the same scale as the dynamics that are to be measured or even shorter.


Light sources


Titanium-sapphire laser

Ti-sapphire laser Ti:sapphire lasers (also known as Ti:Al2O3 lasers, titanium-sapphire lasers, or Ti:sapphs) are tunable lasers which emit red and infrared, near-infrared light in the range from 650 to 1100 nanometers. These lasers are mainly used in scientific res ...
s are tunable lasers that emit red and near-infrared light (700 nm- 1100 nm).
Ti-sapphire laser Ti:sapphire lasers (also known as Ti:Al2O3 lasers, titanium-sapphire lasers, or Ti:sapphs) are tunable lasers which emit red and infrared, near-infrared light in the range from 650 to 1100 nanometers. These lasers are mainly used in scientific res ...
oscillators use Ti doped-sapphire crystals as a gain medium and Kerr-lens mode-locking to achieve sub-picosecond light pulses. Typical Ti:sapphire oscillator pulses have nJ energy and repetition rates 70-100 MHz.
Chirped pulse amplification Chirped pulse amplification (CPA) is a technique for amplifying an ultrashort pulse, ultrashort laser pulse up to the petawatt level, with the laser pulse being stretched out temporally and spectrally, then amplified, and then compressed again. The ...
through
regenerative amplification In laser science, regenerative amplification is a process used to generate short but strong pulses of laser light. It is based on a pulse trapped in a laser resonator, which stays in there until it extracts all of the energy stored in the amplifi ...
can be used to attain higher pulse energies. For amplification, laser pulses from the Ti:sapphire oscillator must first be stretched in time to prevent damage to optics, and then are injected into the cavity of another laser where pulses are amplified at a lower repetition rate. Regeneratively amplified pulses can be further amplified in a multi-pass amplifier. Following amplification, the pulses are recompressed to pulse widths similar to the original pulse widths.


Dye laser

A
dye laser A dye laser is a laser that uses an organic dye as the lasing medium, usually as a liquid solution. Compared to gases and most solid state lasing media, a dye can usually be used for a much wider range of wavelengths, often spanning 50 to 100 ...
is a four-level laser that uses an organic dye as the gain medium. Pumped by a laser with a fixed wavelength, due to various dye types you use, different dye lasers can emit beams with different wavelengths. A ring laser design is most often used in a dye laser system. Also, tuning elements, such as a diffraction grating or prism, are usually incorporated in the cavity. This allows only light in a very narrow frequency range to resonate in the cavity and be emitted as laser emission. The wide tunability range, high output power, and pulsed or CW operation make the dye laser particularly useful in many physical & chemical studies.


Fiber laser

A fiber laser is usually generated first from a
laser diode The laser diode chip removed and placed on the eye of a needle for scale A laser diode (LD, also injection laser diode or ILD, or diode laser) is a semiconductor device similar to a light-emitting diode in which a diode pumped directly with e ...
. The
laser diode The laser diode chip removed and placed on the eye of a needle for scale A laser diode (LD, also injection laser diode or ILD, or diode laser) is a semiconductor device similar to a light-emitting diode in which a diode pumped directly with e ...
then couples the light into a fiber where it will be confined. Different wavelengths can be achieved with the use of doped fiber. The pump light from the
laser diode The laser diode chip removed and placed on the eye of a needle for scale A laser diode (LD, also injection laser diode or ILD, or diode laser) is a semiconductor device similar to a light-emitting diode in which a diode pumped directly with e ...
will excite a state in the doped fiber which can then drop in energy causing a specific wavelength to be emitted. This wavelength may be different from that of the pump light and more useful for a particular experiment.


X-ray generation

Ultrafast optical pulses can be used to generate
x-ray An X-ray, or, much less commonly, X-radiation, is a penetrating form of high-energy electromagnetic radiation. Most X-rays have a wavelength ranging from 10  picometers to 10  nanometers, corresponding to frequencies in the range 30&nb ...
pulses in multiple ways. An optical pulse can excite an
electron The electron ( or ) is a subatomic particle with a negative one elementary electric charge. Electrons belong to the first generation of the lepton particle family, and are generally thought to be elementary particles because they have no ...
pulse via the
photoelectric effect The photoelectric effect is the emission of electrons when electromagnetic radiation, such as light, hits a material. Electrons emitted in this manner are called photoelectrons. The phenomenon is studied in condensed matter physics, and solid sta ...
, and acceleration across a high potential gives the electrons kinetic energy. When the electrons hit a target they generate both
characteristic x-ray Characteristic X-rays are emitted when outer-shell electrons fill a vacancy in the inner shell of an atom, releasing X-rays in a pattern that is "characteristic" to each element. Characteristic X-rays were discovered by Charles Glover Barkla in 190 ...
s and
bremsstrahlung ''Bremsstrahlung'' (), from "to brake" and "radiation"; i.e., "braking radiation" or "deceleration radiation", is electromagnetic radiation produced by the deceleration of a charged particle when deflected by another charged particle, typicall ...
. A second method is via laser-induced plasma. When very high-intensity laser light is incident on a target, it strips electrons off the target creating a negatively charged plasma cloud. The strong Coulomb force due to the ionized material in the center of the cloud quickly accelerates the electrons back to the nuclei left behind. Upon collision with the nuclei, Bremsstrahlung and characteristic emission x-rays are given off. This method of x-ray generation scatters photons in all directions, but also generates picosecond x-ray pulses.


Conversion and characterization


Pulse characterization

For accurate spectroscopic measurements to be made, several characteristics of the laser pulse need to be known; pulse duration, pulse energy, spectral phase, and spectral shape are among some of these. Information about pulse duration can be determined through autocorrelation measurements, or from cross-correlation with another well-characterized pulse. Methods allowing for complete characterization of pulses include
frequency-resolved optical gating Frequency-resolved optical gating (FROG) is a general method for measuring the spectral phase of ultrashort laser pulses, which range from subfemtosecond to about a nanosecond in length. Invented in 1991 by Rick Trebino and Daniel J. Kane, FROG was ...
(FROG) and
spectral phase interferometry for direct electric-field reconstruction In ultrafast optics, spectral phase interferometry for direct electric-field reconstruction (SPIDER) is an ultrashort pulse measurement technique originally developed by Chris Iaconis and Ian Walmsley. The basics SPIDER is an interferometric ul ...
(SPIDER).


Pulse shaping

Pulse shaping In electronics and telecommunications, pulse shaping is the process of changing the waveform of transmitted pulses to optimize the signal for its intended purpose or the communication channel. This is often done by limiting the bandwidth of the tra ...
is to modify the pulses from the source in a well-defined manner, including manipulation on pulse’s amplitude, phase, and duration. To amplify pulse’s intensity,
chirped pulse amplification Chirped pulse amplification (CPA) is a technique for amplifying an ultrashort pulse, ultrashort laser pulse up to the petawatt level, with the laser pulse being stretched out temporally and spectrally, then amplified, and then compressed again. The ...
is generally applied, which includes a pulse stretcher, amplifier, and compressor. It will not change the duration or phase of the pulse during the amplification. Pulse compression (shorten the pulse duration) is achieved by first chirping the pulse in a nonlinear material and broadening the spectrum, with the following compressor for chirp compensation. A fiber compressor is generally used in this case. Pulse shapers usually refer to optical modulators which apply Fourier transforms to a laser beam. Depending on which property of light is controlled, modulators are called intensity modulators, phase modulators, polarization modulators, spatial light modulators. Depending on the modulation mechanism, optical modulators are divided into Acoustic-optic modulators, Electro-optic modulators, Liquid crystal modulators, etc. Each is dedicated to different applications.


High harmonic generation

High harmonic generation (HHG) is the nonlinear process where intense laser radiation is converted from one fixed frequency to high harmonics of that frequency by ionization and recollision of an electron. It was first observed in 1987 by McPherson et al. who successfully generated harmonic emission up to the 17th order at 248 nm in neon gas. HHG is seen by focusing an ultra-fast, high-intensity, near-IR pulse into a noble gas at intensities of (1013–1014 W/cm2) and it generates coherent pulses in the XUV to Soft X-ray (100–1 nm) region of the spectrum. It is realizable on a laboratory scale (table-top systems) as opposed to large free electron-laser facilities. High harmonic generation in atoms is well understood in terms of the three-step model (ionization, propagation, and recombination). Ionization: The intense laser field modifies the Coulomb potential of the atom, electron tunnels through the barrier and ionize. Propagation: The free-electron accelerates in the laser field and gains momentum. Recombination: When the field reverses, the electron is accelerated back toward the ionic parent and releases a photon with very high energy.


Frequency conversion techniques

Different spectroscopy experiments require different excitation or probe wavelengths. For this reason, frequency conversion techniques are commonly used to extend the operational spectrum of existing laser light sources. The most widespread conversion techniques rely on using crystals with second-order non-linearity to perform either parametric amplification or frequency mixing. Frequency mixing works by superimposing two beams of equal or different wavelengths to generate a signal which is a higher harmonic or the sum frequency of the first two. Parametric amplification overlaps a weak probe beam with a higher energy pump beam in a non-linear crystal such that the weak beam gets amplified and the remaining energy goes out as a new beam called the idler. This approach has the capability of generating output pulses that are shorter than the input ones. Different schemes of this approach have been implemented. Examples are
optical parametric oscillator An optical parametric oscillator (OPO) is a parametric oscillator that oscillates at optical frequencies. It converts an input laser wave (called "pump") with frequency \omega_p into two output waves of lower frequency (\omega_s, \omega_i) by mean ...
(OPO),
optical parametric amplifier An optical parametric amplifier, abbreviated OPA, is a laser light source that emits light of variable wavelengths by an optical parametric amplifier, parametric amplification process. It is essentially the same as an optical parametric oscillator, ...
(OPA), non-collinear parametric amplifier (NOPA).


Techniques


Ultrafast transient absorption

This method is typical of 'pump-probe' experiments, where a pulsed
laser A laser is a device that emits light through a process of optical amplification based on the stimulated emission of electromagnetic radiation. The word "laser" is an acronym for "light amplification by stimulated emission of radiation". The fi ...
is used to excite the electrons in a material (such as a molecule or semiconducting solid) from their ground states to higher-energy excited states. A probing light source, typically a
xenon arc lamp A xenon arc lamp is a highly specialized type of gas discharge lamp, an electric light that produces light by passing electricity through ionized xenon gas at high pressure. It produces a bright white light to simulate sunlight, with application ...
or broadband laser pulse created by
supercontinuum In optics, a supercontinuum is formed when a collection of nonlinear processes act together upon a pump beam in order to cause severe spectral broadening of the original pump beam, for example using a microstructured optical fiber. The result is ...
generation, is used to obtain an absorption spectrum of the compound at various times following its excitation. As the excited molecules absorb the probe light, they are further excited to even higher states or induced to return to the ground state radiatively through stimulated emission. After passing through the sample, the unabsorbed probe light continues to a
photodetector Photodetectors, also called photosensors, are sensors of light or other electromagnetic radiation. There is a wide variety of photodetectors which may be classified by mechanism of detection, such as photoelectric or photochemical effects, or ...
such as an
avalanche photodiode An avalanche photodiode (APD) is a highly sensitive semiconductor photodiode detector that exploits the photoelectric effect to convert light into electricity. From a functional standpoint, they can be regarded as the semiconductor analog of phot ...
array or CMOS camera, and the data is processed to generate an absorption spectrum of the excited state. Since all the molecules or excitation sites in the sample will not undergo the same dynamics simultaneously, this experiment must be carried out many times (where each "experiment" comes from a single pair of pump and probe laser pulse interactions), and the data must be averaged to generate spectra with accurate intensities and peaks. Because photobleaching and other photochemical or photothermal reactions can happen to the samples, this method requires evaluating these effects by measuring the same sample at the same location many times at different pump and probe intensities. Most time the liquid samples are stirred during measurement making relatively long-time kinetics difficult to measure due to flow and diffusion. Unlike time-correlated single photon counting (TCSPC), this technique can be carried out on non-fluorescent samples. It can also be performed on non-transmissive samples in a reflection geometry. Ultrafast transient absorption can use almost any probe light, so long as the probe is of a pertinent wavelength or set of wavelengths. A monochromator and photomultiplier tube in place of the avalanche photodiode array allows observation of a single probe wavelength, and thus allows probing of the decay kinetics of the excited species. The purpose of this setup is to take kinetic measurements of species that are otherwise nonradiative, and specifically it is useful for observing species that have short-lived and non-phosphorescent populations within the triplet manifold as part of their decay path. The pulsed laser in this setup is used both as a primary excitation source, and a clock signal for the ultrafast measurements. Although laborious and time-consuming, the monochromator position may also be shifted to allow absorbance decay profiles to be constructed, ultimately to the same effect as the above method. The data of UTA measurements usually are reconstructed absorption spectra sequenced over the delay time between the pump and probe. Each spectrum resembles a normal steady-state absorption profile of the sample after the delay time of the excitation with the time resolution convoluted from the pump and probe time resolutions. The excitation wavelength is blinded by the pump laser and cut out. The rest of the spectra usually have a few bands such as ground-state absorption, excited-state absorption, and stimulated emission. Under normal conditions, the angles of the emission are randomly orientated and not detected in the absorption geometry. But in UTA measurement, the stimulated emission resembles the lasing effect, is highly oriented, and is detected. Many times this emission overlaps with the absorption bands and needs to be deconvoluted for quantitative analysis. The relationship and correlation among these bands can be visualized using the classical spectroscopic
two-dimensional correlation analysis Two dimensional correlation analysis is a mathematical technique that is used to study changes in measured signals. As mostly spectroscopic signals are discussed, sometime also two dimensional correlation spectroscopy is used and refers to the same ...
.


Time-resolved photoelectron spectroscopy and two-photon photoelectron spectroscopy

Time-resolved photoelectron spectroscopy and
two-photon photoelectron spectroscopy Time-resolved two-photon photoelectron (2PPE) spectroscopy is a time-resolved spectroscopy technique which is used to study electronic structure and electronic excitations at surfaces. The technique utilizes femtosecond to picosecond laser pulses ...
(2PPE) combine a pump-probe scheme with angle-resolved photoemission. A first laser pulse is used to excite a material, a second
laser A laser is a device that emits light through a process of optical amplification based on the stimulated emission of electromagnetic radiation. The word "laser" is an acronym for "light amplification by stimulated emission of radiation". The fi ...
pulse
ionize Ionization, or Ionisation is the process by which an atom or a molecule acquires a negative or positive charge by gaining or losing electrons, often in conjunction with other chemical changes. The resulting electrically charged atom or molecule ...
s the system. The
kinetic energy In physics, the kinetic energy of an object is the energy that it possesses due to its motion. It is defined as the work needed to accelerate a body of a given mass from rest to its stated velocity. Having gained this energy during its acc ...
of the
electron The electron ( or ) is a subatomic particle with a negative one elementary electric charge. Electrons belong to the first generation of the lepton particle family, and are generally thought to be elementary particles because they have no ...
s from this process is then detected, through various methods including energy mapping,
time of flight Time of flight (ToF) is the measurement of the time taken by an object, particle or wave (be it acoustic, electromagnetic, etc.) to travel a distance through a medium. This information can then be used to measure velocity or path length, or as a w ...
measurements etc. As above, the process is repeated many times, with different time delays between the probe pulse and the pump pulse. This builds up a picture of how the molecule relaxes over time. A variation of this method looks at the positive
ions An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by conven ...
created in this process and is called time-resolved photo-ion spectroscopy (TRPIS)


Multidimensional spectroscopy

Using the same principles pioneered by 2D-NMR experiments, multidimensional optical or infrared spectroscopy is possible using ultrafast pulses. Different frequencies can probe various dynamic molecular processes to differentiate between inhomogeneous and homogeneous
line broadening A spectral line is a dark or bright line in an otherwise uniform and continuous spectrum, resulting from emission or absorption of light in a narrow frequency range, compared with the nearby frequencies. Spectral lines are often used to iden ...
as well as identify coupling between the measured spectroscopic transitions. If two oscillators are coupled together, be it intramolecular vibrations or intermolecular electronic coupling, the added dimensionality will resolve anharmonic responses not identifiable in linear spectra. A typical 2D pulse sequence consists of an initial pulse to pump the system into a coherent superposition of states, followed by a phase conjugate second pulse that pushes the system into a non-oscillating excited state, and finally, a third pulse that converts back to a coherent state that produces a measurable pulse. A 2D frequency spectrum can then be recorded by plotting the Fourier transform of the delay between the first and second pulses on one axis, and the Fourier transform of the delay between a detection pulse relative to the signal-producing third pulse on the other axis. 2D spectroscopy is an example of a
four-wave mixing Four-wave mixing (FWM) is an intermodulation phenomenon in nonlinear optics, whereby interactions between two or three wavelengths produce two or one new wavelengths. It is similar to the third-order intercept point in electrical systems. Four-wave ...
experiment, and the
wavevector In physics, a wave vector (or wavevector) is a vector used in describing a wave, with a typical unit being cycle per metre. It has a magnitude and direction. Its magnitude is the wavenumber of the wave (inversely proportional to the wavelength), ...
of the signal will be the sum of the three incident wavevectors used in the pulse sequence. Multidimensional spectroscopies exist in
infrared Infrared (IR), sometimes called infrared light, is electromagnetic radiation (EMR) with wavelengths longer than those of visible light. It is therefore invisible to the human eye. IR is generally understood to encompass wavelengths from around ...
and visible variants as well as combinations using different wavelength regions.


Ultrafast imaging

Most ultrafast imaging techniques are variations on standard pump-probe experiments. Some commonly used techniques are Electron Diffraction imaging, Kerr Gated Microscopy, imaging with ultrafast electron pulses and
terahertz imaging Terahertz nondestructive evaluation pertains to devices, and techniques of analysis occurring in the terahertz domain of electromagnetic radiation. These devices and techniques evaluate the properties of a material, component or system without cau ...
.PICKWELL E., WALLACE V., J. PHYS. D: APPL. PHYS.,2012, 39, R301-R310 This is particularly true in the biomedical community where safe and non-invasive techniques for diagnosis are always of interest. Terahertz imaging has recently been used to identify areas of decay in tooth enamel and image the layers of the skin. Additionally, it has shown to be able to successfully distinguish a region of breast carcinoma from healthy tissue. Another technique called Serial Time-encoded amplified microscopy has shown to have the capability of even earlier detection of trace amounts of cancer cells in the blood. Other non-biomedical applications include ultrafast imaging around corners or through opaque objects.


Femtosecond up-conversion

Femtosecond up-conversion is a pump-probe technique that uses
nonlinear optics Nonlinear optics (NLO) is the branch of optics that describes the behaviour of light in ''nonlinear media'', that is, media in which the polarization density P responds non-linearly to the electric field E of the light. The non-linearity is typic ...
to combine the
fluorescence Fluorescence is the emission of light by a substance that has absorbed light or other electromagnetic radiation. It is a form of luminescence. In most cases, the emitted light has a longer wavelength, and therefore a lower photon energy, tha ...
signal and probe signal to create a signal with a new frequency via photon upconversion, which is subsequently detected. The probe scans through delay times after the pump excites the sample, generating a plot of intensity over time.


Applications


Applications of femtosecond spectroscopy to biochemistry

Ultrafast processes are found throughout biology. Until the advent of femtosecond methods, many of the mechanism of such processes were unknown. Sundström, V. Annu.Rev.Phys.Chem 2008, 59, 53-77./ref> Examples of these include the cis-trans photoisomerization of the rhodopsin chromophore
retinal Retinal (also known as retinaldehyde) is a polyene chromophore. Retinal, bound to proteins called opsins, is the chemical basis of visual phototransduction, the light-detection stage of visual perception (vision). Some microorganisms use reti ...
, excited state and population dynamics of DNA, and the charge transfer processes in
photosynthetic reaction center A photosynthetic reaction center is a complex of several proteins, pigments and other co-factors that together execute the primary energy conversion reactions of photosynthesis. Molecular excitations, either originating directly from sunlight or t ...
s Charge transfer dynamics in photosynthetic reaction centers has a direct bearing on man’s ability to develop light harvesting technology, while the excited state dynamics of DNA has implications in diseases such as skin
cancer Cancer is a group of diseases involving abnormal cell growth with the potential to invade or spread to other parts of the body. These contrast with benign tumors, which do not spread. Possible signs and symptoms include a lump, abnormal b ...
. Advances in femtosecond methods are crucial to the understanding of ultrafast phenomena in nature.


Photodissociation and femtosecond probing

Photodissociation is a chemical reaction in which a chemical compound is broken down by photons. It is defined as the interaction of one or more photons with one target molecule. Any photon with sufficient energy can affect the chemical bonds of a chemical compound, such as visible light, ultraviolet light, x-rays and gamma rays. The technique of probing chemical reactions has been successfully applied to unimolecular dissociations. The possibility of using a femtosecond technique to study bimolecular reactions at the individual collision level is complicated by the difficulties of spatial and temporal synchronization. One way to overcome this problem is through the use of Van der Waals complexes of weakly bound molecular cluster. Femtosecond techniques are not limited to the observation of the chemical reactions, but can even exploited to influence the course of the reaction. This can open new relaxation channels or increase the yield of certain reaction products.


Picosecond-to-nanosecond spectroscopy


Streak camera

Unlike attosecond and femtosecond pulses, the duration of pulses on the nanosecond timescale are slow enough to be measured through electronic means.
Streak camera A streak camera is an instrument for measuring the variation in a pulse of light's intensity with time. They are used to measure the pulse duration of some ultrafast laser systems and for applications such as time-resolved spectroscopy and LID ...
s translate the temporal profile of pulses into that of a spatial profile; that is, photons that arrive on the detector at different times arrive at different locations on the detector.


Time-correlated single photon counting

Time-correlated single photon counting (TCSPC) is used to analyze the relaxation of molecules from an excited state to a lower energy state. Since various molecules in a sample will emit photons at different times following their simultaneous excitation, the decay must be thought of as having a certain rate rather than occurring at a specific time after excitation. By observing how long individual molecules take to emit their photons, and then combining all these data points, an intensity vs. time graph can be generated that displays the exponential decay curve typical to these processes. However, it is difficult to simultaneously monitor multiple molecules. Instead, individual excitation-relaxation events are recorded and then averaged to generate the curve. This technique analyzes the time difference between the excitation of the sample molecule and the release of energy as another photon. Repeating this process many times will give a decay profile. Pulsed
lasers A laser is a device that emits light through a process of optical amplification based on the stimulated emission of electromagnetic radiation. The word "laser" is an acronym for "light amplification by stimulated emission of radiation". The fir ...
or
LEDs A light-emitting diode (LED) is a semiconductor device that emits light when current flows through it. Electrons in the semiconductor recombine with electron holes, releasing energy in the form of photons. The color of the light (cor ...
can be used as a source of excitation. Part of the light passes through the sample, the other to the electronics as "sync" signal. The light emitted by the sample molecule is passed through a
monochromator A monochromator is an optical device that transmits a mechanically selectable narrow band of wavelengths of light or other radiation chosen from a wider range of wavelengths available at the input. The name is from the Greek roots ''mono-'', "s ...
to select a specific wavelength. The light then is detected and amplified by a
photomultiplier A photomultiplier is a device that converts incident photons into an electrical signal. Kinds of photomultiplier include: * Photomultiplier tube, a vacuum tube converting incident photons into an electric signal. Photomultiplier tubes (PMTs for sh ...
tube (PMT). The emitted light signal as well as reference light signal is processed through a
constant fraction discriminator A constant fraction discriminator (CFD) is an electronic signal processing device, designed to mimic the mathematical operation of finding a maximum of a pulse by finding the zero of its slope. Some signals do not have a sharp maximum, but short ...
(CFD) which eliminates timing jitter. After passing through the CFD, the reference pulse activates a time-to-amplitude converter (TAC) circuit. The TAC charges a
capacitor A capacitor is a device that stores electrical energy in an electric field by virtue of accumulating electric charges on two close surfaces insulated from each other. It is a passive electronic component with two terminals. The effect of ...
which will hold the signal until the next electrical pulse. In reverse TAC mode the signal of "sync" stops the TAC. This data is then further processed by an
analog-to-digital converter In electronics, an analog-to-digital converter (ADC, A/D, or A-to-D) is a system that converts an analog signal, such as a sound picked up by a microphone or light entering a digital camera, into a digital signal. An ADC may also provide ...
(ADC) and multi-channel analyzer (MCA) to get a data output. To make sure that the decay is not biased to early arriving photons, the photon count rate is kept low (usually less than 1% of excitation rate). This electrical pulse comes after the second laser pulse excites the molecule to a higher energy state, and a photon is eventually emitted from a single molecule upon returning to its original state. Thus, the longer a molecule takes to emit a photon, the higher the voltage of the resulting pulse. The central concept of this technique is that only a single photon is needed to discharge the capacitor. Thus, this experiment must be repeated many times to gather the full range of delays between excitation and emission of a photon. After each trial, a pre-calibrated computer converts the voltage sent out by the TAC into a time and records the event in a histogram of time since excitation. Since the probability that no molecule will have relaxed decreases with time, a decay curve emerges that can then be analyzed to find out the decay rate of the event. A major complicating factor is that many decay processes involve multiple energy states, and thus multiple rate constants. Though non-linear least squares analysis can usually detect the different rate constants, determining the processes involved is often very difficult and requires the combination of multiple ultra-fast techniques. Even more complicating is the presence of inter-system crossing and other non-radiative processes in a molecule. A limiting factor of this technique is that it is limited to studying energy states that result in fluorescent decay. The technique can also be used to study relaxation of electrons from the conduction band to the valence band in semiconductors.


See also

*
Time-resolved spectroscopy In physics and physical chemistry, time-resolved spectroscopy is the study of dynamic processes in materials or chemical compounds by means of spectroscopic techniques. Most often, processes are studied after the illumination of a material occurs, ...
*
Terahertz time-domain spectroscopy In physics, terahertz time-domain spectroscopy (THz-TDS) is a spectroscopic technique in which the properties of matter are probed with short pulses of terahertz radiation. The generation and detection scheme is sensitive to the sample's effect on ...
(THz-TDS) *
Electronic configuration In atomic physics and quantum chemistry, the electron configuration is the distribution of electrons of an atom or molecule (or other physical structure) in atomic or molecular orbitals. For example, the electron configuration of the neon atom ...
*
Atomic spectral line Spectroscopy is the field of study that measures and interprets the electromagnetic spectra that result from the interaction between electromagnetic radiation and matter as a function of the wavelength or frequency of the radiation. Matter w ...
*
Attosecond chronoscopy Attosecond chronoscopy are measurement techniques for attosecond-scale delays of atomic and molecular single photon processes like photoemission /en.wikipedia.org/wiki/Attosecond_chronoscopy#endnote_delayand photoionization. Ionization-delay meas ...


References


External links


Ultrafast studies of single semiconductor and metal nanostructures through transient absorption microscopy

''Chemical Science''
mini review by Gregory Hartland *W. Becker: ''The bh TCSPC Handbook.'', Fifth Edition, 2012,

' (Becker & Hickl GmbH, PDF file, 77 MB)
W. Becker: ''The bh TCSPC Handbook.'', 7th Edition, 2017
(Becker & Hickl GmbH, PDF file) *Ultrafast Lasers

{{Lasers Ultrafast spectroscopy