Ethernet over twisted-pair technologies use
twisted-pair cables for the
physical layer
In the seven-layer OSI model of computer networking, the physical layer or layer 1 is the first and lowest layer; The layer most closely associated with the physical connection between devices. This layer may be implemented by a PHY chip.
The ...
of an
Ethernet
Ethernet () is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 198 ...
computer network. They are a subset of all
Ethernet physical layer
The physical-layer specifications of the Ethernet family of computer network standards are published by the Institute of Electrical and Electronics Engineers (IEEE), which defines the electrical or optical properties and the transfer speed ...
s.
Early Ethernet used various grades of
coaxial cable
Coaxial cable, or coax (pronounced ) is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric ( insulating material); many coaxial cables also have a p ...
, but in 1984,
StarLAN StarLAN was the first IEEE 802.3 standard for Ethernet over twisted pair wiring. It was standardized by the standards association of the Institute of Electrical and Electronics Engineers (IEEE) as 802.3e in 1986, as the 1BASE5 version of Ethernet. ...
showed the potential of simple
unshielded twisted pair
Twisted pair cabling is a type of wiring used for communications in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted ba ...
. This led to the development of 10BASE-T and its successors
100BASE-TX
In computer networking, Fast Ethernet physical layers carry traffic at the nominal rate of 100 Mbit/s. The prior Ethernet speed was 10 Mbit/s. Of the Fast Ethernet physical layers, 100BASE-TX is by far the most common.
Fast Ethern ...
,
1000BASE-T and
10GBASE-T, supporting speeds of 10 and 100
megabit per second
In telecommunications, data-transfer rate is the average number of bits (bitrate), characters or symbols (baudrate), or data blocks per unit time passing through a communication link in a data-transmission system. Common data rate units are multi ...
, then 1 and 10 gigabit per second respectively.
Two new variants of 10 megabit per second Ethernet over a ''single'' twisted pair, known as 10BASE-T1S and 10BASE-T1L, were standardized in IEEE Std 802.3cg-2019.
10BASE-T1S has its origins in the automotive industry and may be useful in other short-distance applications where substantial electrical noise is present. 10BASE-T1L is a long-distance Ethernet, supporting connections up to 1 km in length. Both of these standards are finding applications implementing the
Internet of things
The Internet of things (IoT) describes physical objects (or groups of such objects) with sensors, processing ability, software and other technologies that connect and exchange data with other devices and systems over the Internet or other comm ...
.
The earlier standards use
8P8C modular connector
A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets.
Modular connectors were originally developed for ...
s, and supported cable standards range from
Category 3 to
Category 8. These cables typically have four pairs of wires for each connection, although early Ethernet used only two of the pairs. Unlike the earlier -T standards, the -T1 interfaces were designed to operate over a single pair of conductors and introduce the use of two new connectors referred to as IEC 63171-1
and IEC 63171-6.
History
The first two early designs of twisted-pair networking were
StarLAN StarLAN was the first IEEE 802.3 standard for Ethernet over twisted pair wiring. It was standardized by the standards association of the Institute of Electrical and Electronics Engineers (IEEE) as 802.3e in 1986, as the 1BASE5 version of Ethernet. ...
, standardized by the
IEEE Standards Association as
IEEE 802.3e in 1986, at one megabit per second,
and
LattisNet
LattisNet was a family of computer networking hardware and software products built and sold by SynOptics Communications (also rebranded by Western Digital) during the 1980s. Examples were the 1000, 2500 and 3000 series of LattisHub network hubs.
...
, developed in January 1987, at 10 megabit per second.
Both were developed before the 10BASE-T standard (published in 1990 as IEEE 802.3i) and used different signalling, so they were not directly compatible with it.
In 1988, AT&T released StarLAN 10, named for working at 10 Mbit/s. The StarLAN 10 signalling was used as the basis of 10BASE-T, with the addition of ''link beat'' to quickly indicate connection status.
Using twisted-pair cabling in a
star topology addressed several weaknesses of the previous Ethernet standards:
* Twisted-pair cables were already in use for telephone service and were already present in many office buildings, lowering the overall cost of deployment
* The centralized star topology was also already often in use for telephone service cabling, as opposed to the
bus
A bus (contracted from omnibus, with variants multibus, motorbus, autobus, etc.) is a road vehicle that carries significantly more passengers than an average car or van. It is most commonly used in public transport, but is also in use for cha ...
topology required by earlier Ethernet standards
* Using point-to-point links was less prone to failure and greatly simplified troubleshooting compared to a shared bus
* Exchanging cheap
repeater hub
In telecommunications, a repeater is an electronic device that receives a signal and retransmits it. Repeaters are used to extend transmissions so that the signal can cover longer distances or be received on the other side of an obstruction. Some ...
s for more advanced
switching hubs provided a viable upgrade path
* Mixing different speeds in a single network became possible with the arrival of
Fast Ethernet
In computer networking, Fast Ethernet physical layers carry traffic at the nominal rate of 100 Mbit/s. The prior Ethernet speed was 10 Mbit/s. Of the Fast Ethernet physical layers, 100BASE-TX is by far the most common.
Fast Ethern ...
* Depending on
cable grades, subsequent upgrading to
Gigabit Ethernet
In computer networking, Gigabit Ethernet (GbE or 1 GigE) is the term applied to transmitting Ethernet frames at a rate of a gigabit per second. The most popular variant, 1000BASE-T, is defined by the IEEE 802.3ab standard. It came into use i ...
or faster could be accomplished by replacing the network switches
Although 10BASE-T is rarely used as a normal-operation signaling rate today, it is still in wide use with
network interface controllers in
Wake-on-LAN power-down mode and for special, low-power, low-bandwidth applications. 10BASE-T is still supported on most twisted-pair Ethernet ports with up to
Gigabit Ethernet
In computer networking, Gigabit Ethernet (GbE or 1 GigE) is the term applied to transmitting Ethernet frames at a rate of a gigabit per second. The most popular variant, 1000BASE-T, is defined by the IEEE 802.3ab standard. It came into use i ...
speed.
Naming
The common names for the standards derive from aspects of the physical media. The leading number (''10'' in 10BASE-T) refers to the transmission speed in Mbit/s. ''BASE'' denotes that
baseband
In telecommunications and signal processing, baseband is the range of frequencies occupied by a signal that has not been modulated to higher frequencies. Baseband signals typically originate from transducers, converting some other variable into a ...
transmission is used. The ''T'' designates twisted-pair cable. Where there are several standards for the same
transmission speed, they are distinguished by a letter or digit following the T, such as ''TX'' or ''T4'', referring to the encoding method and number of lanes.
Cabling
Most Ethernet cables are wired "straight-through" (pin 1 to pin 1, pin 2 to pin 2, and so on). In some instances the "
crossover
Crossover may refer to:
Entertainment
Albums and songs
* ''Cross Over'' (Dan Peek album)
* ''Crossover'' (Dirty Rotten Imbeciles album), 1987
* ''Crossover'' (Intrigue album)
* ''Crossover'' (Hitomi Shimatani album)
* ''Crossover'' (Yoshino ...
" form (receive to transmit and transmit to receive) may still be required.
Cables for Ethernet may be wired to either the
T568A or T568B termination standards at both ends of the cable. Since these standards differ only in that they swap the positions of the two pairs used for transmitting and receiving, a cable with T568A wiring at one end and T568B wiring at the other results in a crossover cable.
A 10BASE-T or 100BASE-TX host uses a connector wiring called
medium dependent interface
A medium dependent interface (MDI) describes the interface (both physical and electrical/optical) in a computer network from a physical layer implementation to the physical medium used to carry the transmission. Ethernet over twisted pair also d ...
s (MDI), transmitting on pins 1 and 2 and receiving on pins 3 and 6 to a network device. An infrastructure node (a
hub or a
switch
In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type of ...
) accordingly uses a connector wiring called MDI-X, transmitting on pins 3 and 6 and receiving on pins 1 and 2. These ports are connected using a
straight-through cable
A crossover cable connects two devices of the same type, for example DTE-DTE or DCE-DCE, usually connected asymmetrically (DTE-DCE), by a modified cable called a crosslink. Such a distinction between devices was introduced by IBM.
The cross ...
so each transmitter talks to the receiver on the other end of the cable.
Nodes can have two types of ports: MDI (uplink port) or MDI-X (regular port, 'X' for internal crossover). Hubs and switches have regular ports. Routers, servers and end hosts (e.g.
personal computers
A personal computer (PC) is a multi-purpose microcomputer whose size, capabilities, and price make it feasible for individual use. Personal computers are intended to be operated directly by an end user, rather than by a computer expert or techn ...
) have uplink ports. When two nodes having the same type of ports need to be connected, a crossover cable may be required, especially for older equipment. Connecting nodes having different types of ports (i.e., MDI to MDI-X and vice versa) requires a straight-through cable. Thus connecting an end host to a hub or switch requires a straight-through cable. Some older switches and hubs provided a button to allow a port to act as either a normal (regular) or an uplink port, i.e. using MDI-X or MDI pinout, respectively.
Many modern Ethernet host adapters can automatically detect another computer connected with a straight-through cable and then automatically introduce the required crossover if needed; if neither of the adapters has this capability, then a crossover cable is required. Most newer switches have
auto MDI-X
A medium dependent interface (MDI) describes the interface (both physical and electrical/optical) in a computer network from a physical layer implementation to the physical medium used to carry the transmission. Ethernet over twisted pair also d ...
on all ports allowing all connections to be made with straight-through cables. If both devices being connected support 1000BASE-T according to the standards, they will connect regardless of whether a straight-through or crossover cable is used.
A 10BASE-T transmitter sends two
differential voltages, +2.5 V or −2.5 V. A 100BASE-TX transmitter sends three differential voltages, +1 V, 0 V, or −1 V. Unlike earlier Ethernet standards using
broadband
In telecommunications, broadband is wide bandwidth data transmission which transports multiple signals at a wide range of frequencies and Internet traffic types, that enables messages to be sent simultaneously, used in fast internet connections. ...
and
coaxial cable
Coaxial cable, or coax (pronounced ) is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric ( insulating material); many coaxial cables also have a p ...
, such as
10BASE5
10BASE5 (also known as thick Ethernet or thicknet) was the first commercially available variant of Ethernet. The technology was standardized in 1982 as IEEE 802.3. 10BASE5 uses a thick and stiff coaxial cable up to in length. Up to 100 stati ...
(thicknet) and
10BASE2 (thinnet), 10BASE-T does not specify the exact type of wiring to be used but instead specifies certain characteristics that a cable must meet. This was done in anticipation of using 10BASE-T in existing twisted-pair wiring systems that did not conform to any specified wiring standard. Some of the specified characteristics are
attenuation
In physics, attenuation (in some contexts, extinction) is the gradual loss of flux intensity through a medium. For instance, dark glasses attenuate sunlight, lead attenuates X-rays, and water and air attenuate both light and sound at variable att ...
,
characteristic impedance
The characteristic impedance or surge impedance (usually written Z0) of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line; that is, a wave travelling in one direction in ...
,
propagation delay
Propagation delay is the time duration taken for a signal to reach its destination. It can relate to networking, electronics or physics. ''Hold time'' is the minimum interval required for the logic level to remain on the input after triggering e ...
, and several types of
crosstalk
In electronics, crosstalk is any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channel. Crosstalk is usually caused by undesired capacitive, induc ...
. Cable testers are widely available to check these parameters to determine if a cable can be used with 10BASE-T. These characteristics are expected to be met by 100 meters of 24-
gauge
Gauge ( or ) may refer to:
Measurement
* Gauge (instrument), any of a variety of measuring instruments
* Gauge (firearms)
* Wire gauge, a measure of the size of a wire
** American wire gauge, a common measure of nonferrous wire diameter, ...
unshielded twisted-pair cable. However, with high-quality cabling, reliable cable runs of 150 meters or longer are often achievable and are considered viable by technicians familiar with the 10BASE-T specification.
100BASE-TX follows the same wiring patterns as 10BASE-T, but is more sensitive to wire quality and length, due to the higher
bit rate
In telecommunications and computing, bit rate (bitrate or as a variable ''R'') is the number of bits that are conveyed or processed per unit of time.
The bit rate is expressed in the unit bit per second (symbol: bit/s), often in conjunction w ...
s.
1000BASE-T uses all four pairs bi-directionally using
hybrid circuits and
cancellers. Data is encoded using 4D-PAM5; four dimensions using
pulse-amplitude modulation
Pulse-amplitude modulation (PAM) is a form of signal modulation where the message information is encoded in the amplitude of a series of signal pulses. It is an analog pulse modulation scheme in which the amplitudes of a train of carrier pulse ...
(PAM) with five
voltages
Voltage, also known as electric pressure, electric tension, or (electric) potential difference, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to mo ...
, −2 V, −1 V, 0 V, +1 V, and +2 V. While +2 V to −2 V may appear at the pins of the line driver, the voltage on the cable is nominally +1 V, +0.5 V, 0 V, −0.5 V and −1 V.
100BASE-TX and 1000BASE-T were both designed to require a minimum of
category 5 cable
Category 5 cable (Cat 5) is a twisted pair cable for computer networks. Since 2001, the variant commonly in use is the Category 5e specification (Cat 5e). The cable standard provides performance of up to 100 MHz and is ...
and also specify a maximum cable length of . Category 5 cable has since been deprecated and new installations use Category 5e.
Shared cable
10BASE-T and 100BASE-TX require only two pairs (pins 1–2, 3–6) to operate. Since common Category 5 cable has four pairs, it is possible to use the spare pairs (pins 4–5, 7–8) in 10- and 100-Mbit/s configurations for other purposes. The spare pairs may be used for
power over Ethernet
Power over Ethernet, or PoE, describes any of several standards or ad hoc systems that pass electric power along with data on twisted-pair Ethernet cabling. This allows a single cable to provide both data connection and electrical power to d ...
(PoE), for two
plain old telephone service
Plain old telephone service (POTS), or plain ordinary telephone system, is a retronym for voice-grade telephone service employing analog signal transmission over copper loops. POTS was the standard service offering from telephone companies from 1 ...
(POTS) lines, or for a second 10BASE-T or 100BASE-TX connection. In practice, great care must be taken to separate these pairs as 10/100-Mbit/s Ethernet equipment
electrically terminates the unused pins ("Bob Smith Termination"). Shared cable is not an option for Gigabit Ethernet as 1000BASE-T requires all four pairs to operate.
Single-pair
In addition to the more computer-oriented two and four-pair variants, the
10BASE-T1,
100BASE-T1 and
1000BASE-T1 single-pair Ethernet physical layers are intended for industrial and automotive applications or as optional data channels in other interconnect applications. The single pair operates at full duplex and has a maximum reach of (100BASE-T1, 1000BASE-T1 link segment type A) or up to (1000BASE-T1 link segment type B) with up to four in-line connectors. Both physical layers require a balanced twisted pair with an
impedance of 100 Ω. The cable must be capable of transmitting 600 MHz for 1000BASE-T1 and 66 MHz for 100BASE-T1. 2.5 Gb/s, 5 Gb/s, and 10 Gb/s over a 15 m single pair is standardized in 802.3ch-2020. As of 2021, the P802.3cy Task Force is examining having 25, 50, 100 Gb/s speeds at lengths up to 11 m.
Similar to PoE,
Power over Data Lines (PoDL) can provide up to 50 W to a device.
Connectors
*
8P8C modular connector
A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets.
Modular connectors were originally developed for ...
: For stationary uses in controlled environments, from homes to
datacenter
A data center (American English) or data centre (British English)See spelling differences. is a building, a dedicated space within a building, or a group of buildings used to house computer systems and associated components, such as telecommunic ...
s, this is the dominant connector. Its fragile locking tab otherwise limits its suitability and durability. Bandwidths supporting up to
Cat 8 cabling are defined for this connector format.
* M12X: This is the
M12 connector designated for Ethernet, standardized as IEC 61076-2-109. It is a 12 mm metal screw that houses 4 shielded pairs of pins. Nominal bandwidth is 500 MHz (Cat 6A). The connector family is used in chemically and mechanically harsh environments such as factory automation and transportation. Its size is similar to the modular connector.
* ix Industrial:
This connector is designed to be small yet strong. It has 10 pins and a different locking mechanism than the modular connector. Standardized as IEC 61076-3-124, its nominal bandwidth is 500 MHz (Cat 6A).
*
Single-pair Ethernet defines its own connectors:
** IEC 63171-1 “LC”:
This is a 2-pin connector with a similar locking tab to the modular connector, if thicker.
** IEC 63171-6 “industrial”:
This standard defines 5 2-pin connectors that differ in their locking mechanisms and one 4-pin connector with dedicated pins for power. The locking mechanisms range from a metal locking tab to
M8 and M12 connectors with screw or push-pull locking. The 4-pin connector is only defined with M8 screw locking.
Autonegotiation and duplex
Ethernet over twisted-pair standards up through Gigabit Ethernet define both
full-duplex
A duplex communication system is a point-to-point system composed of two or more connected parties or devices that can communicate with one another in both directions. Duplex systems are employed in many communications networks, either to allow ...
and
half-duplex
A duplex communication system is a point-to-point system composed of two or more connected parties or devices that can communicate with one another in both directions. Duplex systems are employed in many communications networks, either to allow ...
communication. However, half-duplex operation for gigabit speed is not supported by any existing hardware.
Higher speed standards,
2.5GBASE-T up to
40GBASE-T
40 Gigabit Ethernet (40GbE) and 100 Gigabit Ethernet (100GbE) are groups of computer networking technologies for transmitting Ethernet frames at rates of 40 and 100 gigabits per second (Gbit/s), respectively. These technologies offer significantly ...
running at 2.5 to 40 Gbit/s, consequently define only full-duplex point-to-point links which are generally connected by
network switch
A network switch (also called switching hub, bridging hub, and, by the IEEE, MAC bridge) is networking hardware that connects devices on a computer network by using packet switching to receive and forward data to the destination device.
A netw ...
es, and do not support the traditional shared-medium
CSMA/CD
Carrier-sense multiple access with collision detection (CSMA/CD) is a medium access control (MAC) method used most notably in early Ethernet technology for local area networking. It uses carrier-sensing to defer transmissions until no other statio ...
operation.
Many different modes of operations (10BASE-T half-duplex, 10BASE-T full-duplex, 100BASE-TX half-duplex, etc.) exist for Ethernet over
twisted pair
Twisted pair cabling is a type of wiring used for communications in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted ba ...
, and most
network adapter
A network interface controller (NIC, also known as a network interface card, network adapter, LAN adapter or physical network interface, and by similar terms) is a computer hardware component that connects a computer to a computer network.
Ear ...
s are capable of different modes of operation.
Autonegotiation is required in order to make a working 1000BASE-T connection.
When two linked interfaces are set to different
duplex modes, the effect of this
duplex mismatch
On an Ethernet connection, a duplex mismatch is a condition where two connected devices operate in different duplex modes, that is, one operates in half duplex while the other one operates in full duplex. The effect of a duplex mismatch is a li ...
is a network that functions much more slowly than its nominal speed. Duplex mismatch may be inadvertently caused when an administrator configures an interface to a fixed mode (e.g. 100 Mbit/s full-duplex) and fails to configure the remote interface, leaving it set to autonegotiate. Then, when the auto-negotiation process fails, half-duplex is assumed by the autonegotiating side of the link.
Variants
See also
*
Classic Ethernet
Classic Ethernet is a family of 10 Mbit/s Ethernet standards, which is the first generation of Ethernet standards. In 10BASE-X, the 10 represents its maximum throughput of 10 Mbit/s, BASE indicates its use of baseband transmission, an ...
*
25-pair color code
*
Copper cable certification
In copper twisted pair wire networks, copper cable certification is achieved through a thorough series of tests in accordance with Telecommunications Industry Association (TIA) or International Organization for Standardization (ISO) standards. Th ...
*
Ethernet extender
*
Network isolator
{{no footnotes, date=May 2014
Network isolators are installed as part of a wired Ethernet system as galvanic isolators to reduce the potential for electrical injury and limit the extent of damage due to lightning strikes.
Through the applied pri ...
Notes
References
External links
*
How to create your own Ethernet Cables
{{DEFAULTSORT:Ethernet Over twisted pair
Ethernet cables
Physical layer protocols
Local loop