Trapped Ion
   HOME

TheInfoList



OR:

An ion trap is a combination of
electric Electricity is the set of physical phenomena associated with the presence and motion of matter that has a property of electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described by ...
and/or
magnetic field A magnetic field is a vector field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular to its own velocity and to ...
s used to capture charged particles — known as
ion An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by conve ...
s — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in physics and chemistry such as precision
mass spectrometry Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a ''mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is use ...
, improved atomic frequency standards, and
quantum computing Quantum computing is a type of computation whose operations can harness the phenomena of quantum mechanics, such as superposition, interference, and entanglement. Devices that perform quantum computations are known as quantum computers. Though ...
. In comparison to neutral atom traps, ion traps have deeper trapping potentials (up to several
electronvolt In physics, an electronvolt (symbol eV, also written electron-volt and electron volt) is the measure of an amount of kinetic energy In physics, the kinetic energy of an object is the energy that it possesses due to its motion. It is defi ...
s) that do not depend on the internal electronic structure of a trapped ion. This makes ion traps more suitable for the study of light interactions with single atomic systems. The two most popular types of ion traps are the
Penning trap A Penning trap is a device for the storage of charged particles using a homogeneous axial magnetic field and an inhomogeneous quadrupole electric field. This kind of trap is particularly well suited to precision measurements of properties of io ...
, which forms a potential via a combination of static electric and magnetic fields, and the
Paul trap A quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented the device and shared the N ...
which forms a potential via a combination of static and oscillating electric fields. Penning traps can be used for precise magnetic measurements in spectroscopy. Studies of quantum state manipulation most often use the Paul trap. This may lead to a
trapped ion quantum computer A trapped ion quantum computer is one proposed approach to a large-scale quantum computer. Ions, or charged atomic particles, can be confined and suspended in free space using electromagnetic fields. Qubits are stored in stable electronic state ...
and has already been used to create the world's most accurate
atomic clocks An atomic clock is a clock that measures time by monitoring the resonant frequency of atoms. It is based on atoms having different energy levels. Electron states in an atom are associated with different energy levels, and in transitions betwee ...
.
Electron gun An electron gun (also called electron emitter) is an electrical component in some vacuum tubes that produces a narrow, collimated electron beam that has a precise kinetic energy. The largest use is in cathode-ray tubes (CRTs), used in nearly ...
s (a device emitting high-speed electrons, used in CRTs) can use an ion trap to prevent degradation of the
cathode A cathode is the electrode from which a conventional current leaves a polarized electrical device. This definition can be recalled by using the mnemonic ''CCD'' for ''Cathode Current Departs''. A conventional current describes the direction in whi ...
by positive ions.


Theory

A charged particle, such as an
ion An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by conve ...
, feels a force from an electric field. As a consequence of Earnshaw's theorem, it is not possible to confine an ion in an electrostatic field. However, physicists have various ways of working around this theorem by using combinations of static magnetic and electric fields (as in a
Penning trap A Penning trap is a device for the storage of charged particles using a homogeneous axial magnetic field and an inhomogeneous quadrupole electric field. This kind of trap is particularly well suited to precision measurements of properties of io ...
) or by oscillating electric fields (
Paul trap A quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented the device and shared the N ...
). In the case of the latter, a common analysis begins by observing how an ion of charge e and mass M behaves in an a.c. electric field \mathbf = \mathbf_0\cos(\Omega t). The force on the ion is given by \mathbf = e\mathbf, so by
Newton's second law Newton's laws of motion are three basic laws of classical mechanics that describe the relationship between the motion of an object and the forces acting on it. These laws can be paraphrased as follows: # A body remains at rest, or in motion ...
we have : M\mathbf = e\mathbf_0\cos(\Omega t) \! . Assuming that the ion has zero initial velocity, two successive integrations give the velocity and displacement as : \mathbf = \frac\sin(\Omega t) \! , : \mathbf = \mathbf_0 - \frac\cos(\Omega t) \! , where \mathbf_0 is a constant of integration. Thus, the ion oscillates with angular frequency \Omega and amplitude proportional to the electric field strength. A trapping potential can be realized by spatially varying the strength of the a.c. electric field.


Linear Paul Trap

The linear Paul trap uses an oscillating
quadrupole A quadrupole or quadrapole is one of a sequence of configurations of things like electric charge or current, or gravitational mass that can exist in ideal form, but it is usually just part of a multipole expansion of a more complex structure refl ...
field to trap ions radially and a static potential to confine ions axially. The quadrupole field is realized by four parallel electrodes laying in the z-axis positioned at the corners of a square in the xy-plane. Electrodes diagonally opposite each other are connected and an a.c. voltage V = V_0\cos(\Omega t) is applied. Along the z-axis, an analysis of the radial symmetry yields a potential : \phi = \alpha + \beta(x^2 - y^2) \! . The constants \alpha and \beta are determined by boundary conditions on the electrodes and \phi satisfies Laplace's equation \nabla^2\phi = 0. Assuming the length of the electrodes r is much greater than their separation r_0, it can be shown that : \phi = \phi_0 + \frac\cos(\Omega t)(x^2 - y^2) \! . Since the electric field is given by the gradient of the potential, we get that : \mathbf = -\frac\cos(\Omega t)(x\mathbf_x - y\mathbf_y) \! . Defining \tau = \Omega t/2, the equations of motion in the xy-plane are a simplified form of the
Mathieu equation In mathematics, Mathieu functions, sometimes called angular Mathieu functions, are solutions of Mathieu's differential equation : \frac + (a - 2q\cos(2x))y = 0, where a and q are parameters. They were first introduced by Émile Léonard Mathieu, ...
, : \frac = -\frac\cos(2\tau)x_i \! .


Penning Trap

A standard configuration for a
Penning trap A Penning trap is a device for the storage of charged particles using a homogeneous axial magnetic field and an inhomogeneous quadrupole electric field. This kind of trap is particularly well suited to precision measurements of properties of io ...
consists of a ring electrode and two end caps. A static voltage differential between the ring and end caps confines ions along the axial direction (between end caps). However, as expected from Earnshaw's theorem, the static electric potential is not sufficient to trap an ion in all three dimensions. To provide the radial confinement, a strong axial magnetic field is applied. For a uniform electric field \mathbf = E\mathbf_x, the force \mathbf = e\mathbf accelerates a positively charged ion along the x-axis. For a uniform magnetic field \mathbf= B\mathbf_z, the
Lorentz Lorentz is a name derived from the Roman surname, Laurentius, which means "from Laurentum". It is the German form of Laurence. Notable people with the name include: Given name * Lorentz Aspen (born 1978), Norwegian heavy metal pianist and keyboar ...
force causes the ion to move in circular motion with
cyclotron frequency Cyclotron resonance describes the interaction of external forces with charged particles experiencing a magnetic field, thus already moving on a circular path. It is named after the cyclotron, a cyclic particle accelerator that utilizes an oscillati ...
: \omega_c = \frac \! . Assuming an ion with zero initial velocity placed in a region with \mathbf = E\mathbf_x and \mathbf= B\mathbf_z, the equations of motion are : x = \frac(1-\cos(\omega_c t)) \! , : y = -\frac(\omega_c t-\sin(\omega_c t)) \! , : z = 0 \! . The resulting motion is a combination of oscillatory motion around the z-axis with frequency \omega_c and a drift velocity in the y-direction. The drift velocity is perpendicular to the direction of the electric field. For the radial electric field produced by the electrodes in a Penning trap, the drift velocity will precess around the axial direction with some frequency \omega_m, called the magnetron frequency. An ion will also have a third characteristic frequency \omega_z between the two end cap electrodes. The frequencies usually have widely different values with \omega_z \ll \omega_m< \ll \omega_c.


Ion trap mass spectrometers

An ion trap
mass spectrometer Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a '' mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is us ...
may incorporate a Penning trap (
Fourier-transform ion cyclotron resonance Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (''m''/''z'') of ions based on the cyclotron frequency of the ions in a fixed magnetic field. T ...
),
Paul trap A quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented the device and shared the N ...
or the
Kingdon trap An ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in phy ...
. The
Orbitrap In mass spectrometry, Orbitrap is an ion trap mass analyzer consisting of an outer barrel-like electrode and a coaxial inner spindle-like electrode that traps ions in an orbital motion around the spindle. The image current from the trapped ions is ...
, introduced in 2005, is based on the Kingdon trap. Other types of mass spectrometers may also use a linear quadrupole ion trap as a selective mass filter.


Penning ion trap

A
Penning trap A Penning trap is a device for the storage of charged particles using a homogeneous axial magnetic field and an inhomogeneous quadrupole electric field. This kind of trap is particularly well suited to precision measurements of properties of io ...
stores charged particles using a strong homogeneous axial
magnetic field A magnetic field is a vector field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular to its own velocity and to ...
to confine particles radially and a quadrupole
electric field An electric field (sometimes E-field) is the physical field that surrounds electrically charged particles and exerts force on all other charged particles in the field, either attracting or repelling them. It also refers to the physical field fo ...
to confine the particles axially. Penning traps are well suited for measurements of the properties of
ions An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by conven ...
and stable charged
subatomic particle In physical sciences, a subatomic particle is a particle that composes an atom. According to the Standard Model of particle physics, a subatomic particle can be either a composite particle, which is composed of other particles (for example, a pr ...
s. Precision studies of the electron magnetic moment by Dehmelt and others are an important topic in modern physics. Penning traps can be used in
quantum computation Quantum computing is a type of computation whose operations can harness the phenomena of quantum mechanics, such as superposition, interference, and entanglement. Devices that perform quantum computations are known as quantum computers. Though ...
and
quantum information processing Quantum information science is an interdisciplinary field that seeks to understand the analysis, processing, and transmission of information using quantum mechanics principles. It combines the study of Information science with quantum effects in p ...
and are used at
CERN The European Organization for Nuclear Research, known as CERN (; ; ), is an intergovernmental organization that operates the largest particle physics laboratory in the world. Established in 1954, it is based in a northwestern suburb of Gene ...
to store antimatter. Penning traps form the basis of Fourier-transform ion cyclotron resonance mass spectrometry for determining the mass-to-charge ratio of
ions An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by conven ...
.Marshall, A. G.; Hendrickson, C. L.; Jackson, G. S., Fourier-transform ion cyclotron resonance mass spectrometry: a primer. ''Mass Spectrom Rev'' 17, 1–35.
/ref> The Penning Trap was invented by
Frans Michel Penning Frans Michel Penning (12 September 1894 – 6 December 1953) was a Dutch experimental physicist. He received his PhD from the University of Leiden in 1923, and studied low pressure gas discharges at the Philips Laboratory in Eindhoven, developing ...
and
Hans Georg Dehmelt Hans Georg Dehmelt (; 9 September 1922 – 7 March 2017) was a German and American physicist, who was awarded a Nobel Prize in Physics in 1989, for co-developing the ion trap technique (Penning trap) with Wolfgang Paul, for which they shared one- ...
, who built the first trap in the 1950s.


Paul ion trap

A Paul trap is a type of
quadrupole ion trap A quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented the device and shared the ...
that uses static
direct current Direct current (DC) is one-directional flow of electric charge. An electrochemical cell is a prime example of DC power. Direct current may flow through a conductor such as a wire, but can also flow through semiconductors, insulators, or even ...
(DC) and
radio frequency Radio frequency (RF) is the oscillation rate of an alternating electric current or voltage or of a magnetic, electric or electromagnetic field or mechanical system in the frequency range from around to around . This is roughly between the upp ...
(RF) oscillating
electric field An electric field (sometimes E-field) is the physical field that surrounds electrically charged particles and exerts force on all other charged particles in the field, either attracting or repelling them. It also refers to the physical field fo ...
s to trap ions. Paul traps are commonly used as components of a
mass spectrometer Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a '' mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is us ...
. The invention of the 3D quadrupole ion trap itself is attributed to
Wolfgang Paul Wolfgang Paul (; 10 August 1913 – 7 December 1993) was a German physicist, who co-developed the non-magnetic quadrupole mass filter which laid the foundation for what is now called an ion trap. He shared one-half of the Nobel Prize in Ph ...
who shared the
Nobel Prize in Physics ) , image = Nobel Prize.png , alt = A golden medallion with an embossed image of a bearded man facing left in profile. To the left of the man is the text "ALFR•" then "NOBEL", and on the right, the text (smaller) "NAT•" then " ...
in 1989 for this work. The trap consists of two
hyperbolic Hyperbolic is an adjective describing something that resembles or pertains to a hyperbola (a curve), to hyperbole (an overstatement or exaggeration), or to hyperbolic geometry. The following phenomena are described as ''hyperbolic'' because they ...
metal electrodes with their foci facing each other and a hyperbolic ring electrode halfway between the other two electrodes.
Ion An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by conve ...
s are trapped in the space between these three electrodes by the oscillating and static electric fields.


Kingdon trap and orbitrap

A Kingdon trap consists of a thin central wire, an outer cylindrical electrode and isolated end cap electrodes at both ends. A static applied voltage results in a radial logarithmic potential between the electrodes. In a Kingdon trap there is no potential minimum to store the ions; however, they are stored with a finite angular momentum about the central wire and the applied electric field in the device allows for the stability of the ion trajectories. In 1981, Knight introduced a modified outer electrode that included an axial quadrupole term that confines the ions on the trap axis. The dynamic Kingdon trap has an additional AC voltage that uses strong defocusing to permanently store charged particles. The dynamic Kingdon trap does not require the trapped ions to have angular momentum with respect to the filament. An
Orbitrap In mass spectrometry, Orbitrap is an ion trap mass analyzer consisting of an outer barrel-like electrode and a coaxial inner spindle-like electrode that traps ions in an orbital motion around the spindle. The image current from the trapped ions is ...
is a modified Kingdon trap that is used for
mass spectrometry Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a ''mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is use ...
. Though the idea has been suggested and computer simulations performed neither the Kingdon nor the Knight configurations were reported to produce mass spectra, as the simulations indicated mass resolving power would be problematic.


Trapped ion quantum computer

Some experimental work towards developing quantum computers use trapped ions. Units of
quantum information Quantum information is the information of the state of a quantum system. It is the basic entity of study in quantum information theory, and can be manipulated using quantum information processing techniques. Quantum information refers to both th ...
called
qubits In quantum computing, a qubit () or quantum bit is a basic unit of quantum information—the quantum version of the classic binary bit physically realized with a two-state device. A qubit is a two-state (or two-level) quantum-mechanical system, ...
are stored in stable electronic states of each ion, and
quantum information Quantum information is the information of the state of a quantum system. It is the basic entity of study in quantum information theory, and can be manipulated using quantum information processing techniques. Quantum information refers to both th ...
can be processed and transferred through the collective quantized motion of the ions, interacting by the Coulomb force.
Lasers A laser is a device that emits light through a process of optical amplification based on the stimulated emission of electromagnetic radiation. The word "laser" is an acronym for "light amplification by stimulated emission of radiation". The fir ...
are applied to induce
coupling A coupling is a device used to connect two shafts together at their ends for the purpose of transmitting power. The primary purpose of couplings is to join two pieces of rotating equipment while permitting some degree of misalignment or end mov ...
between the qubit states (for single qubit operations) or between the internal qubit states and external motional states (for entanglement between qubits).


Cathode ray tubes

Ion traps were used in
television receiver A television set or television receiver, more commonly called the television, TV, TV set, telly, tele, or tube, is a device that combines a tuner, display, and loudspeakers, for the purpose of viewing and hearing television broadcasts, or using ...
s prior to the introduction of aluminized CRT faces around 1958, to protect the phosphor screen from ions. The ion trap must be delicately adjusted for maximum brightness.


See also

*
Laser cooling Laser cooling includes a number of techniques in which atoms, molecules, and small mechanical systems are cooled, often approaching temperatures near absolute zero. Laser cooling techniques rely on the fact that when an object (usually an atom) ...
*
Mass spectrometry Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a ''mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is use ...
* Quantum jump


References


External links


VIAS Science Cartoons
A cranky view of an ion trap...

{{DEFAULTSORT:Ion Trap Mass spectrometry Ions