The Tihange Nuclear Power Station is one of two nuclear energy production sites in
Belgium Belgium, ; french: Belgique ; german: Belgien officially the Kingdom of Belgium, is a country in Northwestern Europe. The country is bordered by the Netherlands to the north, Germany to the east, Luxembourg to the southeast, France to th ...
and contains 3
nuclear power plant A nuclear power plant (NPP) is a thermal power station in which the heat source is a nuclear reactor. As is typical of thermal power stations, heat is used to generate steam that drives a steam turbine connected to a electric generator, generato ...
s. The site is located on the bank of the
Meuse The Meuse ( , , , ; wa, Moûze ) or Maas ( , ; li, Maos or ) is a major European river, rising in France and flowing through Belgium and the Netherlands before draining into the North Sea from the Rhine–Meuse–Scheldt delta. It has a t ...
river, near the village of
Tihange Huy ( or ; nl, Hoei, ; wa, Hu) is a city and municipality of Wallonia located in the province of Liège, Belgium. Huy lies along the river Meuse, at the mouth of the small river Hoyoux. It is in the ''sillon industriel'', the former industrial ...
in the Walloon
province A province is almost always an administrative division within a country or sovereign state, state. The term derives from the ancient Roman ''Roman province, provincia'', which was the major territorial and administrative unit of the Roman Empire ...
of
Liège Liège ( , , ; wa, Lîdje ; nl, Luik ; german: Lüttich ) is a major city and municipality of Wallonia and the capital of the Belgian province of Liège. The city is situated in the valley of the Meuse, in the east of Belgium, not far from b ...
. The station is operated and majority-owned by vertically-integrated Belgian energy corporation
Electrabel Electrabel SA is a Belgian energy corporation. It is a subsidiary of French multinational utility company Engie S.A. (formerly GDF Suez). History Electrabel was established in 1905. Its actual name originates from 1990, after the regrouping of t ...
.
EDF Luminus Luminus (former names: ''Société productrice d'électricité'', SPE, SPE-Luminus, and EDF Luminus) is the second largest electricity producer and energy supplier on the Belgian energy market. Its main shareholder is Électricité de France ...
has a 50% stake in the oldest unit and a 10% stake in the two newest units. It employs 1074 workers and covers an area of . The plant represents about 15% of Belgium's total electricity production capacity. Nuclear energy typically provides half of Belgium's domestically-generated electricity and is the country's lowest-cost source of power.


History

The power station was built by a public utility Intercom which merged into Engie Electrabel in 1990 together with EBES and Unerg. The design of the plant was made by the Belgian engineering firm
Tractebel Tractebel is a Belgian subsidiary which provides consultancy and engineering services in the energy, water, nuclear and infrastructure sectors for the ENGIE group, as well as for national and international institutions and customers in the publ ...
. Tihange 1 entered commercial operation in 1975, Tihange 2 in 1982 and Tihange 3 in 1985. Tihange 1 was delivered by the ACLF (ACECOWEN-
Creusot-Loire Creusot-Loire was a French engineering conglomerate, formed from factories in Le Creusot and Châteauneuf, Loire. The Creusot-Loire subsidiary of ArcelorMittal also includes an Innovation, Research and Development centre for the group. History The ...
-
Framatome Framatome () is a French nuclear reactor business. It is owned by Électricité de France (EDF) (75.5%), Mitsubishi Heavy Industries (19.5%), and Assystem (5%). The company first formed in 1958 to license Westinghouse's pressurized water reacto ...
)
consortium A consortium (plural: consortia) is an association of two or more individuals, companies, organizations or governments (or any combination of these entities) with the objective of participating in a common activity or pooling their resources for ...
. Tihange 2 was built by FRAMACEC (
Framatome Framatome () is a French nuclear reactor business. It is owned by Électricité de France (EDF) (75.5%), Mitsubishi Heavy Industries (19.5%), and Assystem (5%). The company first formed in 1958 to license Westinghouse's pressurized water reacto ...
- ACEC- Cockerill) and Tihange 3 by the ACECOWEN ( ACEC- Cockerill- Westinghouse)
consortium A consortium (plural: consortia) is an association of two or more individuals, companies, organizations or governments (or any combination of these entities) with the objective of participating in a common activity or pooling their resources for ...
. Tihange 2 was shut down at the beginning of June 2012 for a planned inspection. The
ultrasonic Ultrasound is sound waves with frequencies higher than the upper audible limit of human hearing. Ultrasound is not different from "normal" (audible) sound in its physical properties, except that humans cannot hear it. This limit varies fr ...
inspection revealed that there were thousands of semi laminar flaws in the reactor vessel's steel rings forged by Rotterdam Drydocks. These were determined to be hydrogen flakes, which influence
steel Steel is an alloy made up of iron with added carbon to improve its strength and fracture resistance compared to other forms of iron. Many other elements may be present or added. Stainless steels that are corrosion- and oxidation-resistant ty ...
brittleness A material is brittle if, when subjected to stress, it fractures with little elastic deformation and without significant plastic deformation. Brittle materials absorb relatively little energy prior to fracture, even those of high strength. Bre ...
and vessel
pressure Pressure (symbol: ''p'' or ''P'') is the force applied perpendicular to the surface of an object per unit area over which that force is distributed. Gauge pressure (also spelled ''gage'' pressure)The preferred spelling varies by country and e ...
. The reactor remained offline for further inspections and assessment for a year. Eventually the nuclear regulator judged that the reactor could still operate safely and it was restarted 7 June 2013. The restart, was linked to an action plan concerning further investigations of the material properties of the reactor vessel. A piece of steel from a French steam generator with hydrogen flakes was irradiated at the BR-2
materials testing reactor A materials test reactor (MTR) is a high power research nuclear reactor. Examples Materials testing reactors include: * The Materials Testing Reactor (MTR), an early reactor that operated in Idaho from 1952-1970. * Dounreay Materials Testing Re ...
to simulate the lifetime of the reactor vessel. At the end of March 2014 the test results revealed a different outcome compared to what was anticipated by experts. Therefore, the operator (GDF Suez) decided to stop the affected power plant until a clarification could be found and further operation of the powerplant is declared safe. After a re-qualification of the ultrasonic equipment and additional tests on a more similar German made piece of steel the reactor was restarted in November 2015. A separate investigation by
Oak Ridge National Laboratory Oak Ridge National Laboratory (ORNL) is a U.S. multiprogram science and technology national laboratory sponsored by the U.S. Department of Energy (DOE) and administered, managed, and operated by UT–Battelle as a federally funded research and ...
also justified the restart of the unit. The unexpected results were said to be an anomaly with the original test piece. Tihange 1 was shut down from 7 September 2016 to 20 May 2017 for works on the non nuclear infrastructure. During construction works for safety upgrades a non nuclear building with auxiliary pumps was damaged. The reactor had to remain shut down while the building was fixed and the ground layers under the building were reinforced.


Units

The plant consists of three second-generation
pressurized water reactor A pressurized water reactor (PWR) is a type of light-water reactor, light-water nuclear reactor. PWRs constitute the large majority of the world's nuclear power plants (with notable exceptions being the UK, Japan and Canada). In a PWR, the primary ...
s with a total net capacity of 3,008 MWe, slightly more than Belgium's other nuclear power plant at
Doel Doel is a subdivision of the municipality of Beveren in the Flemish province of East Flanders in Belgium. It is located near the river the Scheldt, in a polder of the Waasland. Since 1965, there have been plans to extend the Port of Antwerp into ...
. Its three units are rated as follows:


Design

The design of the plants is reviewed completely every ten years. This so-called RD (révision décennale) is a legal obligation imposed by the Belgian state and the exploitation license of the plant. The purpose of the review is to update the plants to the most recent international safety standards.


Environmental conditions

Various weather conditions have been analysed including
rain Rain is water droplets that have condensed from atmospheric water vapor and then fall under gravity. Rain is a major component of the water cycle and is responsible for depositing most of the fresh water on the Earth. It provides water f ...
,
seiches A seiche ( ) is a standing wave in an enclosed or partially enclosed body of water. Seiches and seiche-related phenomena have been observed on lakes, reservoirs, swimming pools, bays, harbors, caves and seas. The key requirement for formation ...
,
tsunamis A tsunami ( ; from ja, 津波, lit=harbour wave, ) is a series of waves in a water body caused by the displacement of a large volume of water, generally in an ocean or a large lake. Earthquakes, volcanic eruptions and other underwater expl ...
,
floods A flood is an overflow of water ( or rarely other fluids) that submerges land that is usually dry. In the sense of "flowing water", the word may also be applied to the inflow of the tide. Floods are an area of study of the discipline hydrolog ...
,
earthquakes An earthquake (also known as a quake, tremor or temblor) is the shaking of the surface of the Earth resulting from a sudden release of energy in the Earth's lithosphere that creates seismic waves. Earthquakes can range in intensity, from ...
,
wind Wind is the natural movement of air or other gases relative to a planet's surface. Winds occur on a range of scales, from thunderstorm flows lasting tens of minutes, to local breezes generated by heating of land surfaces and lasting a few hou ...
,
tornado A tornado is a violently rotating column of air that is in contact with both the surface of the Earth and a cumulonimbus cloud or, in rare cases, the base of a cumulus cloud. It is often referred to as a twister, whirlwind or cyclone, altho ...
s,
lightning Lightning is a naturally occurring electrostatic discharge during which two electric charge, electrically charged regions, both in the atmosphere or with one on the land, ground, temporarily neutralize themselves, causing the instantaneous ...
,
snow Snow comprises individual ice crystals that grow while suspended in the atmosphere—usually within clouds—and then fall, accumulating on the ground where they undergo further changes. It consists of frozen crystalline water throughout ...
,
hail Hail is a form of solid precipitation. It is distinct from ice pellets (American English "sleet"), though the two are often confused. It consists of balls or irregular lumps of ice, each of which is called a hailstone. Ice pellets generally fal ...
, extreme temperatures,
cyclones In meteorology, a cyclone () is a large air mass that rotates around a strong center of low atmospheric pressure, counterclockwise in the Northern Hemisphere and clockwise in the Southern Hemisphere as viewed from above (opposite to an anti ...
,
sandstorms A dust storm, also called a sandstorm, is a meteorological phenomenon common in arid and semi-arid regions. Dust storms arise when a gust front or other strong wind blows loose sand and dirt from a dry surface. Fine particles are transporte ...
and
waterspout A waterspout is an intense columnar vortex (usually appearing as a funnel cloud, funnel-shaped cloud) that occurs over a body of water. Some are connected to a cumulus congestus cloud, some to a cumuliform cloud and some to a cumulonimbus clou ...
s. The Tihange plant was originally designed for 1000-yearly floods. After Fukushima the design base of the plants was increased 10,000 yearly floods by building a
flood wall A flood wall (or floodwall) is a primarily vertical artificial barrier designed to temporarily contain the waters of a river or other waterway which may rise to unusual levels during seasonal or extreme weather events. Flood walls are mainly u ...
around the plant. Earthquakes were also considered. The historically most significant earthquake for Tihange was the one at
Tienen Tienen (; french: Tirlemont ) is a city and municipality in the province of Flemish Brabant, in Flanders, Belgium. The municipality comprises Tienen itself and the towns of Bost, Goetsenhoven, Hakendover, Kumtich, Oorbeek, Oplinter, Sint-Marg ...
in 1828 with a magnitude of 5.4 on the
Richter scale The Richter scale —also called the Richter magnitude scale, Richter's magnitude scale, and the Gutenberg–Richter scale—is a measure of the strength of earthquakes, developed by Charles Francis Richter and presented in his landmark 1935 ...
. This earthquake resulted in horizontal ground accelerations of up to 0.1g and formed the original design base for Tihange 1. During the first periodic safety review of the unit after 10 years of operation the design base was increased to 0.17g, this corresponded to the design base of the new Tihange 2 and Tihange 3 units. After the
Fukushima Daiichi nuclear disaster The was a nuclear accident in 2011 at the Fukushima Daiichi Nuclear Power Plant in Ōkuma, Fukushima, Japan. The proximate cause of the disaster was the 2011 Tōhoku earthquake and tsunami, which occurred on the afternoon of 11 March 2011 and ...
probabilistic safety studies performed by the
Royal Observatory of Belgium The Royal Observatory of Belgium (french: link=no, Observatoire Royal de Belgique, nl, Koninklijke Sterrenwacht van België), has been situated in the Uccle municipality of Brussels (Belgium) since 1890. It was first established in Saint-Josse ...
predicted earthquakes with peak ground acceleration of up to 0.21g every 10,000 years. The design was subsequently analysed and upgraded for earthquakes up to 0.3g.


Bunker

Besides regular primary level safety systems, in common with most nuclear power plants in the world, Tihange has secondary level safety systems that can autonomously keep the power plant safe during large external accidents such as the crash of an aircraft, external explosions or loss of the primary level. The primary level systems have two or three redundant trains of safety. The secondary level systems are 3x50% or 2x100%. and have their own heatsink separate from the primary heatsink. The primary heatsink is the Meuse river while the secondary heatsink is water from underground water tables.


Double Containment

Nuclear plants are designed with multiple physical barriers to keep fission productions from escaping into the environment. In the case of a
pressurized water reactor A pressurized water reactor (PWR) is a type of light-water reactor, light-water nuclear reactor. PWRs constitute the large majority of the world's nuclear power plants (with notable exceptions being the UK, Japan and Canada). In a PWR, the primary ...
there are three barriers: the fuel cladding which surround the fuel pellets, the primary circuit which houses the fuel rods and finally the
containment building A containment building is a reinforced steel, concrete or lead structure enclosing a nuclear reactor. It is designed, in any emergency, to contain the escape of radioactive steam or gas to a maximum pressure in the range of . The containment i ...
in which the primary circuit is built. In Belgium it was decided to add an extra barrier, a so-called double containment. The primary containment of the containment building, is a pre-stressed concrete cylinder with steel liner. It is surrounded by a secondary containment made of 1.2 to 1.3m thick reinforced concrete. The space between both containments is kept at sub-atmospheric pressure and filters are used to filter potential leaks of the primary containment.


Filtered Containment Venting System

In answer to a question of
die Grünen Die Grünen (German for "the Greens") may refer to: *The Greens – The Green Alternative The Greens – The Green Alternative (german: Die Grünen – Die Grüne Alternative, ) is a green political party in Austria. The party was founded in 19 ...
in the
Bundestag The Bundestag (, "Federal Diet") is the German federal parliament. It is the only federal representative body that is directly elected by the German people. It is comparable to the United States House of Representatives or the House of Commons ...
, the German parliament, the German government replied that the Belgian nuclear power plants do not have filtered containment venting systems installed. In German nuclear power plants these were already built in after the nuclear disaster in Chernobyl in 1986. Other countries followed this example, latest after the
Fukushima nuclear disaster The was a nuclear accident in 2011 at the Fukushima Daiichi Nuclear Power Plant in Ōkuma, Fukushima, Japan. The proximate cause of the disaster was the 2011 Tōhoku earthquake and tsunami, which occurred on the afternoon of 11 March 2011 and ...
. This kind of system allows for the containment pressure to be relieved in the event of a severe accident. The non-condensable gases that cause pressure within containment to rise are released through a stack (or chimney) via a filtration system that removes large quantities of fission products from the effluent. As part of the stress tests following the Fukushima incident, this issue had already been identified to be included in the stress-test action plan (BEST). All units will have functional containment filter venting systems by 2017.


Turbo Feed Pump

Every unit has at least one steam driven
feedwater pump A boiler feedwater pump is a specific type of pump used to pump feedwater into a steam boiler. The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps ar ...
which can supply the steam generators with water to cool down the reactor. These turbine driven pumps can cool down the plant even when no electrical power is available to power the motor driven feedwater pumps during a station blackout like the
Fukushima Daiichi nuclear disaster The was a nuclear accident in 2011 at the Fukushima Daiichi Nuclear Power Plant in Ōkuma, Fukushima, Japan. The proximate cause of the disaster was the 2011 Tōhoku earthquake and tsunami, which occurred on the afternoon of 11 March 2011 and ...
. In a
boiling water reactor A boiling water reactor (BWR) is a type of light water nuclear reactor used for the generation of electrical power. It is a design different from a Soviet graphite-moderated RBMK. It is the second most common type of electricity-generating nuc ...
, like those in Fukushima, the heat removal capacity of the pumps is limited as the steam that drives the turbines is radioactive and thus has to be stored. This is not the case with a PWR due to the use of steam generators. Steam can simply be removed via a
chimney A chimney is an architectural ventilation structure made of masonry, clay or metal that isolates hot toxic exhaust gases or smoke produced by a boiler, stove, furnace, incinerator, or fireplace from human living areas. Chimneys are typic ...
. Autonomy is merely limited by the supplies of water on site. The initial supply of water in the reservoir is sufficient for almost 24 hours. After those 24 hours mobile pumps are used to fill up the reservoir.


Nuclear waste

Low and intermediate level waste, which represents 99% of the volume of waste, is treated on site. Category A waste with half lives of less than 30 years is transported to Belgoprocess in
Dessel Dessel () is a municipality located in the Belgian province of Antwerp. The municipality comprises only the town of Dessel proper. In 2021, Dessel had a total population of 9,659 inhabitants. The total area is 27.03 km². Nuclear industries ...
for surface disposal. High level waste was originally recycled to
MOX fuel Mixed oxide fuel, commonly referred to as MOX fuel, is nuclear fuel that contains more than one oxide of fissile material, usually consisting of plutonium blended with natural uranium, reprocessed uranium, or depleted uranium. MOX fuel is an alt ...
, and re-used in the Tihange 2 reactor. In 1993, the Belgian Federal government placed a moratorium on the reprocessing activities in order to research other options. Pending further decisions regarding this moratorium, spent fuel is stored on site in spent fuel pools. Final disposal of the waste is being researched at the HADES underground laboratory 225m deep in the Boom Clay.
Nuclear transmutation Nuclear transmutation is the conversion of one chemical element or an isotope into another chemical element. Nuclear transmutation occurs in any process where the number of protons or neutrons in the nucleus of an atom is changed. A transmutatio ...
of the waste is also being researched with the
MYRRHA Myrrha (Greek: , ''Mýrra''), also known as Smyrna (Greek: , ''Smýrna''), is the mother of Adonis in Greek mythology. She was transformed into a myrrh tree after having had intercourse with her father, and gave birth to Adonis in tree form. A ...
project.


Incidents

There have been two incidents of level 2 severity on the
International Nuclear Event Scale The International Nuclear and Radiological Event Scale (INES) was introduced in 1990 by the International Atomic Energy Agency (IAEA) in order to enable prompt communication of safety significant information in case of nuclear accidents. The s ...
. On 22 November 2002 a pressure relief valve on the pressurizer inadvertently opened while Tihange 2 was shut down. The reactor was being prepared to be restarted after a planned revision and refuel. While the pressure in the primary circuit was being increased to 155 bar one of the safety valves on the pressurizer inadvertently opened leading to a quick decrease in pressure in the primary circuit. The safety injection system activated as designed and injected cold water ending the transient. On 5 July 2005 a relay of one of the six diesel generators of Tihange 2 was replaced. The device was not correctly tuned which meant that it would not be available during an accident, resulting in less redundancy.


Other


Call for shutdown

Greens member of the European Parliament Rebecca Harms has called for the decommissioning of Belgium's oldest nuclear reactor, Tihange 1, as it no longer meets international safety standards. Harms’ demand coincides with the publication of a new study on the risks of the continued operation of Tihange 1. The author of the study is Prof. Manfred Mertins, an expert in nuclear engineering and former member of the German Nuclear Safety Authority. He presented the findings at a news briefing in the European Parliament. The academic came to the conclusion that the continued operation of Tihange 1 due to “outdated reactor design, inadequate safety management and the accumulation of frequent unplanned events represents a potential danger for the site and its surroundings.” It was particularly critical “that the results of international tests and current safety standards are not adequately taken into account.”


Security

On 15 March 2016, the
federal government of Belgium The Federal Government of Belgium ( nl, Federale regering, french: Gouvernement fédéral, german: Föderalregierung) exercises executive power in the Kingdom of Belgium. It consists of ministers and secretary of state ("junior", or deputy-min ...
decided 140 soldiers would guard the nuclear sites. In late 2015 it was already decided a specially trained department of the
federal police A law enforcement agency (LEA) is any government agency responsible for the enforcement of the laws. Jurisdiction LEAs which have their ability to apply their powers restricted in some way are said to operate within a jurisdiction. LEAs ...
would guard the nuclear sites. After the 2016 Brussels bombings on 22 March the nuclear powerplants of Tihange and
Doel Doel is a subdivision of the municipality of Beveren in the Flemish province of East Flanders in Belgium. It is located near the river the Scheldt, in a polder of the Waasland. Since 1965, there have been plans to extend the Port of Antwerp into ...
were preventively evacuated, as per standard procedure if the threat level in Belgium reaches level 4. The powerplants continued running with a minimum amount of staffing. In February 2017 the Frenchman Jean-Philippe Bainier was installed as the new CEO of Tihange in order to restore confidence in the safety culture at the plant. He succeeded Johan Hollevoet, who was in charge from September 2016 at the Tihange nuclear power station. Together with FANC a new action plan was made in order to raise the safety culture level. 'Safety is my first priority', insured the Engie Top-woman Isabelle Kocher: 'On the safety of our people, of the people living near the power plants and the environment is not to bargain.' In the action plan the responsibilities were more clearly defined and the company was willing to will appeal more independent expertise. The action plan includes a total of 314 actions, of which 142 were already carried out. The intention was that around August 2017 the action plan was to be completed.


Decaying concrete in Doel-3 and Tihange-3

In September 2018 during a planned inspection by the exploitant Engie Electrabel decaying concrete was found in the bunker-buildings of Doel 3 and Tihange 3, where the emergency-systems are located. Only after further investigations and when FANC gives permission, will the reactors be restarted. According to FANC the decay of the concrete had no impact on thee direct environment of the reactors. The restart of reactor Doel-1 and Doel-2 was already earlier postponed from October to December 2018 because needed maintenance. After inspection also in Doel-4 and Tihange-2 concrete decay was found in the ceilings of the buildings. On 24 September 2018, Minister Marie-Christine Marghem of Energy, mentioned during a press-conference that she would contact the Netherlands, France and Germany, to help Belgium with extra capacity for electricity. Only one nuclear power station was available until November, because the repairs of the concrete ceilings does take too much time. Engie Electrabel was criticized because the firm had waited too long to communicate the problems with the concrete in the buildings.AD.NL (24 September 201
Belgium asks for extra electricity capacity
/ref>


Double turbines

The Tihange 1 plant has two separate turbines to produce electricity, the total net electrical power of 962 MW is produced by two 481 MW turbines. These are referred to as Tihange 1N and Tihange 1S, ''turbogroupe nord'' (North) and ''sud'' (South) respectively.


See also

*
List of nuclear power stations The following page lists operating nuclear power stations. The list is based on figures from PRIS (Power Reactor Information System) maintained by International Atomic Energy Agency.Doel Nuclear Power Station The Doel Nuclear Power Station is one of two nuclear power plants in Belgium. The plant includes 4 reactors. The site is located on the bank of the Scheldt river, near the village of Doel in the Flemish province of East Flanders, on the outskir ...


References

{{reflist, 30em


External links

* Website Electrabel regarding the nuclear plant Tihang
Electrabel
Tihange Huy ( or ; nl, Hoei, ; wa, Hu) is a city and municipality of Wallonia located in the province of Liège, Belgium. Huy lies along the river Meuse, at the mouth of the small river Hoyoux. It is in the ''sillon industriel'', the former industrial ...
Nuclear power stations using pressurized water reactors Nuclear technology in Belgium Electrabel nuclear power stations Buildings and structures in Liège Province Huy