The silt density index is a measure for the fouling capacity of water in
reverse osmosis Reverse osmosis (RO) is a water purification process that uses a partially permeable membrane to separate ions, unwanted molecules and larger particles from drinking water. In reverse osmosis, an applied pressure is used to overcome osmotic pre ...
systems. The test measures the rate at which a 0.45-
micrometre The micrometre ( international spelling as used by the International Bureau of Weights and Measures; SI symbol: μm) or micrometer (American spelling), also commonly known as a micron, is a unit of length in the International System of Unit ...
filter is plugged when subjected to a constant water pressure of . The SDI gives the percent drop per minute in the flow rate of the water through the filter, averaged over a period of time such as 15 minutes. Typically, spiral-wound reverse osmosis systems will need an SDI less than 5, and hollow fiber reverse osmosis systems will need an SDI less than 3. In these kinds of systems, deep-well waters (with a typical SDI of 3) could be used straight from the source. If fed from surface waters (with a typical SDI greater than 6), the water will need to be filtered before use. Seawater desalination plants utilising reverse osmosis systems also need very efficient filtering due to the typically high but variable SDI of seawater.


References

Water treatment Membrane technology {{Hydrology-stub